Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAccepted-AOC GANGA APARTMENT NEW BANSBARI MALDA 732102 | MALDA | MALDA | WEST BENGAL | 732102 | L1 | Accepted-AOC L1 | |
| 2 | L2₹1.4 L+₹485.06 (0.34%)Rejected-AOC GROUND FLOOR GANGA APARTMENT KOTHABARI NEW BANSHBARI MALDA | 73 | L2 | Rejected-AOC L2 | |
| 3 | L3₹1.4 L+₹1,346.74 (0.94%)Rejected-AOC BANDARAILAH MALDA | MALDA | MALDA | WEST BENGAL | L3 | Rejected-AOC L3 | |
| 4 | L4₹1.5 L+₹2,568.33 (1.80%)Rejected-AOC 22 LASKARDIGHI WEST DIST PURBA BARDHAMAN | PURBA BARDHAMAN | WEST BENGAL | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹3,000
Closing Date
6 Sept 2024, 12:00 pmClosed
Executive Engineer (AM), Malda-II (AM) Division
Executive Engineer (AM), Malda-II (AM) Division, Madhabnagar, Mokdampur, Malda, Administrative Building (1st Floor), Mokdampur-732103, Malda.
Electrification of Godown at Malda-III Stack Yard Within Malda-II (A-M) Division, Malda Under Core Sector 20-21 Programme.
2024_WRDD_741064_1
WRDD/EEAM /MLD-II /NIT-16e/24-25
Open Tender
Electrical Work/ Equipment
Item Wise
90 days
Malda-III (A-M) Stack Yard, Mokdumpur, Malda.
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,000
24 Sept 2024
29 Aug 2024
9 Sept 2024
29 Aug 2024
6 Sept 2024
29 Aug 2024
Amount
Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of uilding construction) (a)25mm dia 3 m thick polythene pipe.
Cutting channel of 43 mm x 43 mm size on masonry wall incl S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works a)25mm dia 3 m thick polythene pipe without earth continuity wire.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required (a) 2x22/0.3 (1.5 sqmm)
(b)2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting.
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish. i) 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC, i)Average run 6 mtr.
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth ontinuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. (a) 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC On Board
Supplying and fixing Sheet steel Main Switches on angle iron frame on wall 63a havells.
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.Havells make - 2+6 way Enclosure (DHDPSNODRW06)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. [D-5, 6] Havells - 80 amp - FP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & B characteristics on din rail of existing DBs and necessary connection [D-6, 7] Havells - 63 amp SP
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Havells make - 2+8 way Enclosure (8GB32102RC10)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Havells make - 2+16 way Enclosure (8GB32102RC10)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. [D-5, 6] Havells - 40 amp - DP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & B characteristics on din rail of existing DBs and necessary connection [D-6, 7] Seimens - 6-32 A amp SP
Supply & Fixing 240 V Moduler socket (2 module) type fan regulator (step type) (Brand approved by EIC) on existing moduler GI switch board with top cover plate incl making necessary connections etc.
Fixing only starters (for motor control) on flat iron frame / angle iron frame on wall- (a) Direct on Line starter for motor (upto 5 HP) (On angle iron frame (for higher rating)) (Havells/Philips/ Poller/Usha etc.)
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter. (b) 30 cm (12")
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mmdia x 62 mm long) (b) For GI 30 cm Exhaust fan (12")
Fixing only Wall fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener.(Havells/Philips or equivalent) MIROLTA Slim 36W HF
Supplying & fixing 240 V , 25 A Moduler type starter (Brand approved by EIC) with 25 A Moduler switch type DP (MCB) (C-Curve) and 4 module GI moduler type switch board with 4 module top cover plate flushed in wall incl. S&F Switch board & cover plate & making necessary connection with PVC Cu wire & earth continuty wire etc.
Exhoust fan - 300 mm Sweep Single phase [ Pre lubricated Double ball bearing for maintaince free running with protective bird guard & robust construction, Speed - 900-1400 RPM,input power 50 w - 82 w. (Havells/Philips/ Poller/Usha )
Ceiling fan - 1200 mm Sweep, 345 - 400 RPM, High performance even low voltage(180 V - 230 V)& power input (55w-74 w), capable air delivery 200CMM-238 CMM, with wider tip blades for effective air circulation. (Decorative trims on blae & canopy) .IP 55 protected. (Havells/Philips/ Poller/Usha )
Supplying & Laying of one no. Cable 25 sq. Mm Aluminium armoured cable (Brand approved by EIC) in underground trench 460mm wide X760mm average depth , with brick protection on the top of the cable with 8(eight) nos. Bricks per Mtr. Including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : For 3.5 core upto 25 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 3.5 core 25 sqmm cable
Earthing Installation – with Pipe Electrode :2. Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(a) By TATA-Medium GI pipe
GI protection: Suppling & fixing medium gauge GI Pipe (TATA-Medium or ISI-Medium) Protection with necessary fittings and jointing metarials as required. - For 25 mm dia. - ISI-M
Earth Basbar: Suppling & fixing earth busber of galvanized (Hot dip) MS flat 25x6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts , nuts, washers, spacing insulators etc. as required.
Earth continuity conductor: Connecting the equipments to earth busbar including S & F GI (Hot dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. - No. 4 SWG
Earting instalation: Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work (1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 25.56 cm with locking arrangement , GI reducer including drilling of 46 nos. 12 mm dia holes on GI pipe.
Extra for treatment of soil by using salt & charcoal or coke for plate electrode (for soft soil/ morrum soil)
Add 18% GST
Add 1% Cess
MERCURY ENGINEERINGCOMPANY (BID ID -5510219)
NABAUDYAG ELECTRICAL ENGINEERING CO OP. SOC. LTD. (BID ID -5518036)
MAA ENTERPRISE (BID ID -5524217)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .