Loading…
Loading…
Tender Value
₹3.6 Cr
EMD Value
₹1.8 L
Closing Date
29 May 2026, 5:00 pmClosed
MR Ahammad Danish
CE(Raipur)
CONSTRUCTION OF APPROACH ROAD I/C. CULVERTS TO 40 NOS GAD QUARTER AT GARIYABAND, DIST. GARIYABAND( GARIYABAND DN.
190517
NIT NO: 205/TC/2026-27
RESTRICTED TENDER
WORKS
3 days
CE(Raipur)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
7 documents required · 7 mandatory
Public Works Department (PWD)
WORKS
MR Ahammad Danish
RESTRICTED TENDER
PERCENTAGE
A B
CE(Raipur)
PWD Circle-2,Raipur
Gariyaband Division
120
03
No
0
190517
29 May, 2026 5:00:00 PM IST
3 Jun, 2026 10:00:00 AM IST
8 May, 2026 5:00:00 PM IST
NIT NO: 205/TC/2026-27
CONSTRUCTION OF APPROACH ROAD I/C. CULVERTS TO 40 NOS GAD QUARTER AT GARIYABAND, DIST. GARIYABAND( GARIYABAND DN.
179600.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
35918000.00
2
2 Jun, 2026 5:00:00 PM IST
35918000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
20d 23h 27m
7 documents required · 6 mandatory · 1 optional
₹0
₹1.8 L
8 May 2026
8 May 2026
3 Jun 2026
8 May 2026
29 May 2026
8 May 2026
2 Jun 2026
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 meters including removal and disposal of top organic soil not exceeding 150 mm in thickness if required and as per relevant clauses of section-200. In area of light jungle
Excavation in Soil (by Mechanical Means.) Excavation for roadway in soil using mechanical means including loading in tipper for carrying of cut earth to embankment site and unloading with all lifts and lead upto 1000 meters as per relevant clauses of section 300.
Construction of Embankment with Material Deposited from Roadway Cutting (Construction of embankment with approved materials having C.B.R.>5 (unless specified otherwise in the contract) deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2)
Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material, , carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 Plant mix method (with Mechanically crushed stone only) For Lower Sub-base with Grading-III Material
Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material, , carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 Plant mix method (with Mechanically crushed stone only) For Sub-base cum drainage layer or upper sub-base with Grading-VI Material
Dry Lean Cement Concrete Sub-base as per IRC:SP-49 (Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 26.5 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per clause 601.)
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub-base, coarse and fine aggregate conforming to IS:383, and graded as per table 600-3, mixed as per approved mix design at site, laid, spread, vibrated, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing as per clause 602.) With Cement concrete grade M-30 and minimum cement content @ 375 kg/cum.
Providing and fixing guard stones 200 x 200 x 900 mm made of precast RCC M-20 grade fixed at 300 mm into the ground in P.C.C. 1:3:6 blocks of size 400 x 400 x 400 mm and given two coats of paint with white and black bands including excavation.
Painting on Concrete Surfaces Two coats on new surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces)
Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia., across the road ( new construction ) , extending from drain to drain in cuts and toe of slopes to toe of slopes in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipes as per IRC: 98-2011, bedded on a 0.3 m thick layer of granular material free of rock pieces , outer to outer distance of pipes at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts , joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC:98-2011 and approved drawings. Single row for one utility service 300 mm dia
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) Ordinary soil Up to 3 m depth
Plain cement concrete complete as per drawing and Technical Specifications PCC Grade M 15
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts including fixing collar with cement mortar 1:2 but excluding bedding below pipes, excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . ) 450 mm dia
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts including fixing collar with cement mortar 1:2 but excluding bedding below pipes, excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . ) 600 mm dia
Retro- reflectrorized Traffic signs (Providing and fixing of retro- reflectrorized cautionary, mandatory and informatory sign as per IRC:67-2012 made of retro-reflective type sheeting vide clause 801.3, fixed over aluminum sheeting of required thicknes supported on a mild steel back frame of ISA 40 x 40 x 5 mm and mild steel angle iron post 75 mm x 75 mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45cm x 60cm, 60 cm below ground level as per approved drawing and apinting all components of the signs and supports as per clause 7.2 of IRC:2012) Made of Class -A High Intensity Super Engineering Grade Sheeting of Type II (For ODR & Village Roads) With Aluminum Sheeting of 2mm thickness 900 mm equilateral triangle
Retro- reflectrorized Traffic signs (Providing and fixing of retro- reflectrorized cautionary, mandatory and informatory sign as per IRC:67-2012 made of retro-reflective type sheeting vide clause 801.3, fixed over aluminum sheeting of required thicknes supported on a mild steel back frame of ISA 40 x 40 x 5 mm and mild steel angle iron post 75 mm x 75 mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45cm x 60cm, 60 cm below ground level as per approved drawing and apinting all components of the signs and supports as per clause 7.2 of IRC:2012) Made of Class -A High Intensity Super Engineering Grade Sheeting of Type II (For ODR & Village Roads) With Aluminum Sheeting of 2mm thickness 800 mm x 600 mm rectangular
Retro- reflectrorized Traffic signs (Providing and fixing of retro- reflectrorized cautionary, mandatory and informatory sign as per IRC:67-2012 made of retro-reflective type sheeting vide clause 801.3, fixed over aluminum sheeting of required thicknes supported on a mild steel back frame of ISA 40 x 40 x 5 mm and mild steel angle iron post 75 mm x 75 mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45cm x 60cm, 60 cm below ground level as per approved drawing and apinting all components of the signs and supports as per clause 7.2 of IRC:2012) Made of Class -A High Intensity Super Engineering Grade Sheeting of Type II (For ODR & Village Roads) With Aluminum Sheeting of 2mm thickness 750 cm high octagon
Retro- reflectrorized Traffic signs (Providing and fixing of retro- reflectrorized cautionary, mandatory and informatory sign as per IRC:67-2012 made of retro-reflective type sheeting vide clause 801.3, fixed over aluminum sheeting of required thicknes supported on a mild steel back frame of ISA 40 x 40 x 5 mm and mild steel angle iron post 75 mm x 75 mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45cm x 60cm, 60 cm below ground level as per approved drawing and apinting all components of the signs and supports as per clause 7.2 of IRC:2012) Made of Class -A High Intensity Super Engineering Grade Sheeting of Type II (For ODR & Village Roads) With Aluminum Sheeting of 1.5 mm thickness 600 mm equilateral triangle
Retro- reflectrorized Traffic signs (Providing and fixing of retro- reflectrorized cautionary, mandatory and informatory sign as per IRC:67-2012 made of retro-reflective type sheeting vide clause 801.3, fixed over aluminum sheeting of required thicknes supported on a mild steel back frame of ISA 40 x 40 x 5 mm and mild steel angle iron post 75 mm x 75 mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45cm x 60cm, 60 cm below ground level as per approved drawing and apinting all components of the signs and supports as per clause 7.2 of IRC:2012) Made of Class -A High Intensity Super Engineering Grade Sheeting of Type II (For ODR & Village Roads) With Aluminum Sheeting of 1.5 mm thickness 600 mm Circular
Retro- reflectrorized Traffic signs (Providing and fixing of retro- reflectrorized cautionary, mandatory and informatory sign as per IRC:67-2012 made of retro-reflective type sheeting vide clause 801.3, fixed over aluminum sheeting of required thicknes supported on a mild steel back frame of ISA 40 x 40 x 5 mm and mild steel angle iron post 75 mm x 75 mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45cm x 60cm, 60 cm below ground level as per approved drawing and apinting all components of the signs and supports as per clause 7.2 of IRC:2012) Made of Class -A High Intensity Super Engineering Grade Sheeting of Type II (For ODR & Village Roads) With Aluminum Sheeting of 1.5 mm thickness 600 mm x 500mm Rectangular
Retro- reflectrorized Traffic signs (Providing and fixing of retro- reflectrorized cautionary, mandatory and informatory sign as per IRC:67-2012 made of retro-reflective type sheeting vide clause 801.3, fixed over aluminum sheeting of required thicknes supported on a mild steel back frame of ISA 40 x 40 x 5 mm and mild steel angle iron post 75 mm x 75 mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45cm x 60cm, 60 cm below ground level as per approved drawing and apinting all components of the signs and supports as per clause 7.2 of IRC:2012) Made of Class -A High Intensity Super Engineering Grade Sheeting of Type II (For ODR & Village Roads) With Aluminum Sheeting of 1.5 mm thickness 600mm x 600mm Square
Direction and Place Identification signs upto 0.9 sqm size board. (Providing and erecting direction and place identification retro-reflectorized sign as per IRC:67-2012 made of retro-reflective type sheeting and vide clause 801.3, fixed over aluminum sheeting, 2 mm thick with area not exceeding 0.9 sqm and fiexed on a mild steel back frame of ISA 400x 40 x 5 mm, supported on a mild steel single angle iron post of size 75 x 75 x 6 mm firmly fixed to the ground with M15 grade cement concrete 45 x 45 x 60cm, 60cm below ground level as per approved drawing) Made of Class-A High Intensity Mirco Prismatic Grade Sheeting of Type I (for ODR & Village Roads)
Direction and Place Identification signs with size more than 0.9 sqm size board. (Providing and erecting direction and place identification retro- reflectorized sign as per IRC:67-2012 made of retro-reflective type sheeting vide clause 801.3, fixed over aluminum sheeting, 2 mm thick with area exceeding 0.9 sqm and fixed on a mild steel frame of size 40 x 40 x 5 mm, supported on 2 Nos. mild steel angle iron post of size 75 x 75 x 6 mm, firmly fixed to the ground with M15 grade cement concrete 45 x 45 x60 cm, 60cm below ground level as per approved drawing ) Made of Class-A High Intensity Mirco Prismatic Grade Sheeting of Type I (for ODR & Village Roads)
Kilo Meter Stone (Reinforced cement concrete M15grade kilometer stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) Ordinary Kilometer stone (Precast)
Kilo Meter Stone (Reinforced cement concrete M15grade kilometer stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) Hectometer stone (Precast)
Providing & Fixing Hazard Marker Type-2 Partial Retro Reflective Size 0.30 x 0.90M made of 16 gauge (1.6 mm) thick mild steel sheet Confirming to IS:2062 Painted with one cast of Zinc Chromate Stoving Primer and two coats of Black Stove Enamel (Oven Baked) paint with 10 cm bands of yellow Retro- Reflective Sheeting of Engineering Grade pasted a per IRC:79 including one MS angle Iron post of size 50x50x5 mm of 1.65 meter long duly painted with synthetic enameled paint block including bolts and fixing the same in M-15 concrete black of size 30x30x30cm, including transportation etc. Complete.
Construction of RCC Drain/Cover/Chamber Excavation for drain (Earth work in excavation for drain/chamber as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)
Construction of RCC Drain/Cover/Chamber Construction of RCC drain/chamber cover, placing in position, providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications excluding reinforcement. with RCC M-20
Construction of RCC Drain/Cover/Chamber Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in drain/cover/chamber complete as per Drawing and Technical Specifications.
Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material including dewatering etc. complete. Ordinary soil Upto 3M depth
Sand Filling in Foundation Trenches as per Drawing & Technical Specifications.
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. Using concrete mixer PCC Grade M l5
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. Using concrete mixer PCC Grade M20
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. Using concrete mixer RCC Grade M 25
Supplying, fitting and placing HSD (High Strength Deformed Steel) bar reinforcement in foundation complete as per drawing and technical specifications as per section 1600.
Providing and laying Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications section 1500, 1700 and 2200 (Newly laid concrete shall be covered by gunny bags). Height upto 5m Using concrete mixer P.C.C. Grade M-20
Providing and laying Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications section 1500, 1700 and 2200 (Newly laid concrete shall be covered by gunny bags). Height upto 5m Using concrete mixer R.C.C. Grade M-20
Providing and laying Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications section 1500, 1700 and 2200 (Newly laid concrete shall be covered by gunny bags). Height upto 5m Using concrete mixer R.C.C. Grade M-25
Supplying, fitting and placing HSD (High Strength Deformed Steel) bars reinforcement in sub-structure complete as per drawing and technical specifications section 1600 and 2200.
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification 710.1.4 of I.R.C. 78 and 2200. Granular material
Providing weep holes in Brick masonry/ Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia. AC pipe, extending through the full width of the structure with slope of 1 V: 20 H towards drawing face. Complete as per drawing and Technical specifications section 2706 and 2200.
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MORT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specifications 710.1.4 of I.R.C. 78 and 2200.
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 meters and as per relevant clauses of section-200 in Lime / Cement Concrete Lime Concrete, cement concrete grade M-10 and below
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 meters and as per relevant clauses of section-200 in Lime / Cement Concrete Cement Concrete Grade M-15 & M-20
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 meters and as per relevant clauses of section-200 in Stone Masonry Rubble stone masonry in cement mortar.
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 meters and as per relevant clauses of section-200 in Removing all type of hume pipes and stacking within a lead upto 1000 m including earthwork and dismantling of masonry work around pipes. Up to 1000 mm dia
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification sections 1500, 1600 and 1700 (Newly laid concrete shall be covered by gunny bags). RCC Grade M30 For Solid Slab Super Structure Using Concrete Mixer Height upto 5m
Supplying, fitting and placing HSD (High Strength Deformed Steel) bar reinforcement in super-structure complete as per drawing and technical specifications
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications as per relevant clause of section 2700.
Filler joint Providing & fixing 20 mm thick compressible fiber board (12 m long x 25 cm deep ) in expansion joint complete as per drawing & Technical Specification.
Providing and fixing in position tar paper bearing for slab as per approved drawings and specification.
Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications. (vide drawing No. SD/201, SD/304)
Drainage Spouts complete as per drawing and Technical specifications of section 2705
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification and as per relevant section 2700
Providing and laying M-30 grade Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification and as per relevant sections 1500, 1600, 1700 and 2704
UOM Name
Percentage
Per mile
Siemens Per meter
Activity unit
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.08 MB
310909727681151724_152662_9133295183868357873_125601_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
7442331505580090568_190517_FORM A.doc
NIT • 0.15 MB
1276784454402509094_190517_NIT.doc
NIT • 0.35 MB
8220811772831041024_190517_190517 Notice.docx
NIT • 0.04 MB
2170057877257843107_190517_BOQ.xls
BOQ • 0.17 MB
Download all tender documents and submit your bid