Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC 5 31 EWS PREETAM NAGAR ALLAHABAD 211011 | ALLAHABAD | ALLAHABAD | UTTAR PRADESH | 211011 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.7 L+₹2.7 L (12.0%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹25.4 L+₹3.3 L (15.2%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹30.7 L+₹8.6 L (39.0%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
4 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST PRAYAGRAJ
GE WEST PRAYAGRAJ PIN-211001
REPAIR MAINTENANCE OF DIFFERENT TYPE OF FANS, AC, GEYSER AND OTHER ELECTRIC APPLIANCES FOR OTM ACCN AT NEW CANTT PRAYAGRAJ.
2024_MES_663581_1
8748/E8
Open Tender
Civil Works
Item Rate
270 days
NEW CANTT PRAYAGRAJ
As per tender Documents
8 documents required · 8 mandatory
₹500
GE WEST PRAYAGRAJ
₹60,000
Yes
29 Oct 2024
3 Jul 2024
11 Sept 2024
3 Jul 2024
4 Sept 2024
17 Jul 2024
Amount
CEILING FAN / EXHAUST FAN
Taking down carefully Ceiling fan 1200/1400 mm sweep any size any capacity any sweep including dismantling of blade down rod fan for recognised defects at site or deposit to store complete all as specified & directed Note : (i) Refixing and reconnection etc of ceiling fan due painting /over hauling etc shall be measured and paid separately (ii) Any damage or loss of fan during taking down shall be made good by the contractor at his own cost.
Opening up of ceiling fan for examination joint inspection preparation of inventory of each fan assessing & listing the nature and details for repair /overhauling /providing new lubricating, grease in bearing/bushes, re-assembling, commissioning and testing complete providing nuts, bolts, locking bolts, blades screws, split pin, rubber real, PVC connector, washers whereas required and refixing in position complete all as specified & directed. Note:- All major repair such as replacement of Bush, bearing , condenser, shaft, connection wire , winding & painting will be measured & paid separately under respective item of Schedule 'A' here-in-after
Upto 4 Meters height.
Above 4 Meters height.
M&L for removing of burnt winding from ceiling fan stator of size 1200mm/1400mm sweep and rewinding the same with equal gauge of super enameled copper winding wire, insulating paper, varnishing and testing complete incl transportation to contractor's work shop and bringing back to store and testing complete all as specified & directed. Note :- (i) Cost of transportation shall be burned by the contractor. (ii) All ceiling fans will be handed over to contractor through issue voucher duly showing details / number of ceiling fan and received back after necessary rewinding through receipt voucher duly signed by all Engr-in-charge, JE & contractor & countersigned by GE.
M&L for scraping all foreign materials with emery paper, cleaning the body, blades, legs, frame and down rod (preparatory work) for painting ceiling fan and painting with one coat of supper enameled white paint (spray paint)/grey paint and writing of MES No. with capital letter of size 20 mm height and 03 mm width with synthetic enameled black paint for Ceiling fan 1200mm/1400mm sweep complete all as specified & directed.
S&F in replacement of gun metal bush suitable for ceiling fan any as per site requirements complete all as specified & directed
S & F condenser with PVC clamp of the following capacities:-
Taking down the ceiling fan down rod and replace with new down rod made out of GI tubing medium grade cutting, threaded and holes drilled both ends (dual arrangement), making holes – 02 Nos & painting with two coats of synthetic enamel white colour paint, fixing the down road to the fan and re-hanging the fan complete including their electric connections complete all as specified & directed Note- GI tubing will be measured and paid separately under respective item here-in-after.
S& F for providing GI tubing 15 mm bore heavy grade ISI marked as down rod for hanging of ceiling fan complete all as specified & directed
S& F GI tubing 50 mm bore heavy grade ISI marked for fixing on walls including PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in PCC block of size 230x230x150 mm for grouting ends of pipe & all fittings for hanging of Ceiling fans complete all as directed.
M&L for fan hook made out of MS flat 50x6 mm suitably shaped to mount on 40 mm dia GI pipe including welded MS bar 10 mm dia half round shaped & necessary nuts & bolts complete all as specified & directed.
M&L for replacement of celling fan shaft complete of size & quality of 1200 mm sweep as per existing all as specified & directed.
Material and labour for replacement of U/S stator block made of laminated sheets of size and quality of 1200 mm sweep as per existing all as specified and directed by E-in-C
S&F electronic socket size, rotary, 5 speed step type regulator, 120-230 V white finish complete all as specified & directed.
S&F fan blade set (set of three) made out of aluminium suitable for 1200 mm sweep ceiling fan, as per existing size and gauge complete all as specified & directed. Make : as per sample of existing fan.
All as per srl item No 14 here-in-before but 1400 mm sweep complete all as specified & directed
M&L for replacement of ceiling fan shaft complete of size & quality of 1400 mm sweep as per existing complete all as specified & directed
M&L for replacement of unserviceable stator block made of laminated sheets of size and quality of 1400 mm sweep as per existing complete all as specified & directed
S & F Outer cover as per existing shape and size complete all as specified & directed.
S & F PVC canopy of 1200/1400 mm sweep ceiling fan complete all as specified & directed.
S&F in replacement PVC insulated three core wire copper conductor 1100 Volt grade of size 0.5 Sqmm complete all as specified & directed.
S&F in replacement of ball bearing (No 6201, 6202 & 6203) suitable for Ceiling fan 1200mm/1400mm suitable as per site requirements complete all as specified & directed.
S & F of PCB for BLDC Ceiling Fan of capacity 1200mm sweep complete all as specified & directed.
EXHAUST FAN
Taking down carefully exhaust fan /wall fan /pedestal fan /air circulators any size any capacity any sweep including dismantling of blade down rod fan for recognised defects at site or deposit to store complete all as directed by Engi-in-Charge Note : (i) Refixing and reconnection etc of exhaust fan /wall fan /pedestal fan /air circulators & due painting /over hauling etc shall be measured and paid separately (ii) Any damage or loss of fan during taking down shall be made good by the contractor at the own cost
Disconnecting & Taking down Exhaust fan/wall fan/Pedestal fan/ air circulator any make any size from any position at site transporting to MES store Yard & dismantling blades opening the stator and rotor of fan and providing new lubricating, grease in bearing/bushes, reassembling incl providing nuts, bolts, locking bolts, blades screws, split pin, rubber reel, PVC connector, rubber pad, washers whereas required all as directed by Engineer-in-charge. Note:- All major repair such as replacement of Bush, bearing , condenser, shaft, connection wire, winding & painting will be measured & paid separately under supply only items here-in-after
Refixing and testing Exhaust fan/wall fan/Pedestal fan/ air circulator any make any size from any position at site in position etc including provision of cable from Ceiling fan to Ceiling Rose PVC flexible three core cable of size 23/0.0076 copper conductor ISI Mar white in colour complete all as specified and directed Note : PVC copper wire/cable will be measured and paid separately under respective item.
S&F in replacement PVC insulated three core wire copper conductor 1100 Volt grade of size 0.5 Sqmm complete all as specified and directed.
S&F in replacement PVC insulated three core wire copper conductor 1100 Volt grade of size 1.0 Sqmm complete all as specified and directed.
S&F in replacement of ball bearing suitable for following sizes complete all as specified and directed.
Exhaust fan/wall fan/pedestal fan upto 380mm sweep
Exhaust fan / pedestal fan / air circulator 450mm to 600mm sweep
Material and Labour for removing of burnt winding from exhaust fan/ Air Circulators/ Wall mounted fans/ pedestal fans rewinding the same with equal gauge of super enameled copper winding wire, insulating paper, varnishing and testing complete incl transportation to work shop and bringing back to store and testing for following fans.
Exhaust Fan 9” sweep.
Exhaust Fan 12” sweep.
Exhaust Fan 18” sweep
Wall Mounted Fan 16” sweep.
S & F of revolving mechanism of wall mounted fan suitable for 400 mm sweep or as per existing type complete all as specified and directed.
S & F stator block of wall mounted fan as per existing design and material suitable for 400 mm sweep complete all as specified and directed.
S & F rotor block as per existing suitable for 400 mm sweep wall mounted fan complete all as specified and directed.
S&F in replacement of gun metal bush suitable for pedestal fan/ exhaust fan complete all as specified and directed.
Supply and fixing capacitors with PVC clamp of the following capacities:-
M&L for scraping all foreign materials with emery paper, cleaning the body, blades, legs, frame and down rod (preparatory work) for painting of exhaust fan/air circulator fan/pedestal fan and painting with one coat of supper enameled white paint (spray paint)/grey paint and writing of MES No. with capital letter of size 20 mm height and 03 mm width with synthetic enameled black paint complete all as specified and directed.
Exhaust Fan 9”/12" sweep.
Exhaust Fan 18” sweep single phase/ three phase.
M&L for making circular holes suitable for fixing of 18” sweep exhaust fans by cutting the wall any thickness/ required circumstances for exhaust of air and including grouting of rag bolts and nuts complete including finishing of disturbed surfaces by using cement mortar 1:3 complete all as required at site complete all as specified and directed.
All as per item No 38 above but suitable for 12” sweep exhaust fan complete all as specified and directed.
S&F in replacement of wall mounted fan blade suitable for 400 mm sweep fan as per existing complete all as directed by Engr-in-Charge.
S&F exhaust fan MS blade 12” to 15” as per existing complete all as specified and directed.
S&F exhaust fan MS blade 18” to 24” as per existing complete all as specified and directed.
M&L for MS front frame suitable for mounting of stays of 9" exhaust fan made out of MS Sheet not less than 1.6mm thick painted with two coat of synthetic enamelled over a coat of red oxide primer complete with necessary fixing accessories such as nut, bolts washers etc & fixing to wall all as per existing & site requirement including taking down old unserviceable front frame complete all as specified and directed.
All as per Srl item No. 43 but suitable for 12" exhaust fan complete all as specified and directed.
All as per Srl item No. 43 but suitable for 18" exhaust fan complete all as specified and directed.
M&L for MS stay work (set of 4) suitable for 9" exhaust fan made out of not less than 20 x 3mm MS strip bent to shape complete painted with two coat of synthetic enamelled over a coat of red oxide primer complete with necessary fixing accessories such as nut, bolts washers etc & fixing to wall all as per existing & site requirement including taking down old unserviceable existing MS work complete all as specified and directed.
All as per Srl item No. 46 but suitable for 12" exhaust fan made out of not less than 25 x 4mm MS strip complete all as specified and directed.
All as per Srl item No. 46 but suitable for 18" exhaust fan made out of not less than 25 x 4mm MS strip complete all as specified and directed.
M&L for circular / rectangular framed shutters suitable for 9" exhaust fan made out of MS sheet not less than 1 mm thick for frame & not less than 0.6mm thick for shutter painted with two coat of synthetic enamelled over a coat of red oxide primer complete with necessary fixing accessories all as per existing & as per site requirement complete all as specified and directed.
All as per Srl item No. 49 but suitable for 12" exhaust fan complete all as specified and directed.
All as per Srl item No. 49 but suitable for 18" exhaust fan complete all as specified and directed.
M&L for replacement of exhaust fan shaft for 9/12 " complete of size & quality as per existing complete all as specified and directed.
S&F in replacement of MS louvers shutters on wall suitable for 380/450 mm sweep exhaust fan including suitable size of nut, bolts & washer complete all as specified and directed.
S&F in replacement of exhaust fans PVC body of size 250mm sweep including taking down the old unserviceable one and depositing the same in MES yard for further disposal complete all as specified and directed.
S&F in replacement of Wall mounting fans PVC body of size 400 mm sweep including taking down the old unserviceable one and depositing the same in MES yard for further disposal complete all as specified and directed.
GEYSERS
Taking down the geyser from existing position for general cleaning/overhauling, cleaning and descaling the tank and assembly with suitable detergent and making fully serviceable (the item required for making the geyser serviceable, shall be measured and paid separately under respective item of Schedule mentioned here in after) and refixing in new/old position and testing complete all as specified and directed.
S&F in replacement of fusible plug type air release valve complete all as specified and directed.
S&F rubber gasket of thickness 5mm for geyser assembly of 06/08/09 holes complete all as specified and directed.
S&F in replacement of aperture plate assembly of 06/08/09 holes suitable for 25/35/50 Ltrs geysers with suitable size of nut bolts/stud/washer complete all as specified and directed. Make - Bajaj/ Theeta/ CG
S&F indicating lamp for geyser rectangular /round type red/ green suitable for any type of geyser complete all as specified and directed.
S&F in replacement of sheet metal bottom/upper cover of Geyser with existing size and gauge 18/20 SWG suitable for 25/35/50 Ltr complete all as specified and directed
S&F in replacement of bottom show cover of Geyser of gauge 18 SWG of capacity 25 Ltr/35 Ltr/50 Ltr complete all as specified and directed.
S&F in replacement glass wool of superior quality complete all as specified and directed.
S&F in replacement of inner tank vertical type suitable for 25 Ltr geyser duly enamel coated glass wood steel tank of Geyser of gauge 18 SWG of capacity complete all as specified and directed.
S&F in replacement of inner tank vertical type suitable for 50 Ltr geyser duly enamel coated steel tank of Geyser of gauge 18 SWG of capacity complete all as specified and directed.
S&F in replacement of outer body of Geyser suitable for 25 Ltr capacity of geyser of 20 SWG mild steel sheet duly painted complete all as specified and directed.
S&F in replacement of outer body of Geyser suitable for 35/50 Ltr capacity of geyser of 20 SWG mild steel sheet duly painted complete all as specified and directed.
S&F in replacement of sheet metal enclosure single pole and neutral, earth plug & socket of capacity 20 Amp including one MCB SP, 25 Amp 10 KA, curve ‘C’ series complete all as specified and directed.
S&F in replacement of MCB SP 32 Amps, breaking capacity 10 kA, curve ‘C’ series complete all as specified and directed.
M&L for preparation of body of geyser by knotting and stopping of outer surface, repainting the complete outer surface of geyser with two coat of synthetic enameled paint complete all as specified and directed.
S&F PVC connection 15mm dia,600mm long (Heavy duty)complete all as specified and directed.
S&F Chromium plated connection pipe, 15mm dia,600mm long (Heavy duty) complete all as specified and directed.
S&F in repair stop valves cast copper alloy screwed down high pressure with crutch or butter fly handle concealed type screwed both ends of size 15 mm bore complete all as specified and directed
S&F in repair Thermostat suitable for geyser range 20 degree to 80 degree (ISI marked) complete all as specified and directed. Make-Thermo king/Theeta/Bajaj/Recold or equivalent
S&F in replacement of heating element 1.5 KW/2 KW, round cup type with rubber gasket complete all as specified and directed. Make: Theeta/Bajaj/CG
S&F in repair heating element 1.5 KW/2 KW, triangle type with rubber gasket complete all as specified and directed. Make: Theeta/Bajaj/CG
S&F in repair heating element 1.5 KW/2 KW, Spare type with rubber gasket complete all as specified and directed. Make: Theeta/Bajaj/Recold
S&F in repair heating element 3 KW, Spare/triangle type with rubber gasket complete all as specified and directed. Make: Theeta/Bajaj/Recold
S&F in repair plug top 15 Amp 3 pin complete all as specified and directed.
M&L for repair to leaking copper/steel tank of 25 Ltr/50 Ltr capacity by brazing as necessary to make leak proof complete all as specified and directed.
M&L for repair of apparatus plate assembly of 06/08/09 holes suitable for 25/35/50 Ltrs geysers by brazing as necessary to make leak proof complete all as specified and directed.
S&F fastener mild steel 100mm longx10mm dia with pin and bolts complete for hanging of geyser and making good the disturbed surfaces including plastering and white washing complete all as specified and directed
S&F fastener mild steel 150mm longx10mm dia with pin and bolts complete for hanging of geyser and making good the disturbed surfaces including plastering and white washing complete all as specified and directed.
S&F in replacement PVC insulated flexible wire three core 2.5 sqmm copper conductor heavy duty complete all as specified and directed.
S&F in replacement electronic sensor for thermal setting as per sample kept in GE’s office complete all as specified and directed. .
S&F in replacement of MCB DP 32 amp, 230 volt, AC , 10 KA with indication & enclosure complete all as specified and directed.
S&F in replacement of Non return valve vertical type screwed for both ends with 15mm bore GI pipe complete all as specified and as directed.
AIR CONDITIONER
Overhauling & servicing of window /Split/tower type Air Conditioners up to 2.0 Ton capacity of any make and carry out of following tasks at different location of different establishment including taking down the AC (if required) from existing location , refixing / commissioning and testing the same after overhauling complete including the following :- (a) Inspection taking down, opening (dismantling) ,washing the condenser and cooling coil complete with water by fixing indoor pvc jacket as required and cleaning with air blower and testing complete (b) Checking / examine operation of condenser, blower motor, cooling coil and checking the air circulation to ensure complete movement of working part trouble free (c) Inspection of leakage in system and removal obstruction if any (d) Inspecting all electrical connection and remove if any defects (e) Top up Refrigerant gas if required. Note: Replacement of new parts/worn out parts in lieu of unserviceable/burn out part shall be measured and paid separately as supply only items of sch A.
Supply only the following spare parts for up to 2.0 ton capacity of Tower/window/ Split type AC any make & any model.
Air Filter Make and model-as per existing
Starting relay Make-Totaline/Epcos/CLASSIC/Whirlpool
Starting capacitor 120-150 mfd Make- Totaline / Epcos /Whirlpool
Starting capacitor 100-120 mfd. Make- Totaline / Epcos /Whirlpool
Running capacitor 40-60 mfd. Make- Totaline/ Epcos/Whirlpool
Running capacitor 30-36 mfd. Make- Totaline / Epcos /Whirlpool
Running capacitor 4-6 mfd. Make- Totaline/ Epcos/Whirlpool
Thermostat switch Make as per existing
Propeller fan suitable for window/split type AC Make- As per existing
Cooling Coil Make- as per existing
Condenser coil Make- as per existing
Outer cover duly painted for Window/split AC
MCB SP 20-32 Amps ‘C’ Series ,10KA, 240 volts SP Make : Havells/HPL/Legrand
Three pin metallic socket outlet suitable for sheet metal enclosure Make : Havells/HPL/Legrand
Three pin metallic plug top suitable for sheet metal enclosure Make : Havells/HPL/Legrand
Front grill for split/window AC Make as per existing
Wiring kit with thimbles
Power Contactors 240 volts AC 50HZ 16-25 Amps range.
Power contactor 415V AC, 50 Hz 20-32 Amps range
Overload protector suitable for compressor as per existing.
Blower motor for indoor unit/window AC as per existing.
Removing the burnt/defective sealed compressor unit any type of any make from Air Conditioner window type up to 2.0 ton capacity by cutting of suction and discharge lines unscrewing the foundation nuts & bolts etc, supply and fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with filling of refrigerant gas (in quoted rate), welding/brazing work and tightening foundation nuts & bolts including etc all as directed. Note:- (a) Capillary, drier, copper tubing etc are inclusive in unit rate. (b) New compressors will be purchased from authorised dealer only.
All as per Sr item No. 90 above but for air conditioner split type 1.5 ton capacity.
All as per Sr item No. 90 above but for air conditioner split type 2.0 ton capacity.
M&L for replacement of damaged copper tubing of dia 1/2 inch including insulation with heavy duty foam and brazing work in Split Air conditioners for discharge and suction of gas between indoor and outdoor unit complete of sizes as per requirement and specified.
M&L for replacement of damaged copper tubing of dia 1/4 inch including insulation with heavy duty foam and brazing work in Split Air conditioners for discharge and suction of gas between indoor and outdoor unit complete of sizes as per requirement and specified.
M&L for replacement of damaged insulation with heavy duty foam for copper tubing of split air conditioners complete all as directed
S&F in replacement of PVC drain pipes of size 15 mm from indoor unit to exist point as per design including accessories clamps fasteners complete all as specified and as directed by Engineer-in-charge.
Repair to Air conditioner Window/Split type upto 2.0 ton to capacity by testing the leakage in system by filling of Nitrogen gas upto suitable pressure and repairing of leakage with brazing work, cleaning and flushing out the complete system, replacing of drier/filter if required, making the complete system leak proof, vacuuming the system and charging Refrigerant gas (M410a/R134a/R-22) as existing and testing etc complete all as specified & directed. Note :(a) Drier/filter, capillary and copper tubing are inclusive in unit rate. (b) Contractor should be responsible if leakage of refrigerant gas after repair on completing job and done same job without extra payment.
Supply and replacement blower Motor 1/5 or 1/6 HP 230V AC, 50 Hz suitable for Air conditioner window type upto 2.0 ton capacity as per existing model complete all as directed and specified.;
Supply and fix in replacement blower Motor 0.2/0.25 HP for Air conditioner split type of capacity 1.5 ton/2.0 ton as per existing model complete as directed and specified.
Repair and fixing blower Motor of split type /window type Air Conditioners of any make and any capacity for making air conditioner serviceable complete all as directed and specified.
Repair and fixing Condenser Motor (outdoor motor) for split type Air conditioner as per existing model of any make and any capacity for making air conditioner serviceable complete all as directed and specified.
Repair and fixing Printed Circuit Board of split type /window type Air Conditioners of any make and any capacity for making air conditioner serviceable complete all as directed and specified.
Supply and fix in replacement Printed Circuit Board as per existing model to repair to split type/window type Air Conditioners of any make and type of any capacity any complete all as directed Make- Voltas/Carrier/toshiba.
Supply and fix in replacement Inverter Type Printed Circuit Board (for indoor and outdoor unit complete) of any make and type of air conditioner split inverter type of any make and type (variable speed compressor) as per existing model and capacity up to 2.0 ton complete all as specified and directed. Make: Carrier /Electrolux/LG/HITACHI
Repair and fixing Inverter Type Printed Circuit Board of split type Air Conditioners (with variable speed compressor) of any make and any capacity for making air conditioner serviceable complete all as directed and specified.
Supply and replacement for wireless remote control unit for split/window type air conditioner as per existing model complete all as directed. Make Carrier /LG/VOLTAS
M&L for outdoor unit stand for wall mounting type or floor mounted complete factory made as recommended for make Air conditioner and approved by Engr-in-charge.
M&L for Shifting and refixing of split type AC (Indoor and Outdoor units) of any make and any type after servicing and charging of gas (M410a/R134a/R-22/r32) by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system as existing and testing etc complete all as specified & directed. Note :(a) Dismantling and refixing of split AC are including in quoted rate. (b)Drier capillary, copper tubing, refrigerant gas, Insulation and LDPE pipe are inclusive in quoted rate.(c) making hole and filling the hole on wall with PCC (1:2:4) type BO (Using 12.5mm graded stone aggregate, 15mm thick rendering in cement mortar (1:3) good the disturbed surface with existing colour matching are inclusive in quoted rate.
M&L for attending day to day complaints and rectifying faults like decarbonizing connections in the AC Box, , any burning due to over loading in AC and restoring connection of AC with wire or thimbles, attending and rectifying faults related to AC like drain water leakage ,filter cleaning, remote setting etc and related to stabilizers (5 to 8 KVA) including Sunday & Holidays complete all as directed by Engineer-in-Charge. Note : (i) All T&P required shall be provided by contractor including ladders of any size as per requirement at site. (iii) Minor items like machine screw, plastic clamps, insulation tape, nails, flexible pipe, thimbles, lugs for contactor, etc shall deemed to be included in the unit rate. (iv) The major items replaced during repairs shall be measured and paid under respective items of Sch 'A'.
WATER COOLER
Dismantling of electric connection and water connection of water cooler opening the condenser fan motor blade, electrical accessories and spare parts of system carefully servicing of serviceable parts replacement of U/S parts oiling of fan motor etc reassembling all spare parts incl rewiring of internal connection of water cooler, testing and commissioning complete all as specified. Note : New spares replaced against Worn out or unserviceable spare parts shall be measured and paid separately as supply only under respective item of this sch.
Removing burnt/defective sealed compressor unit of any make from water cooler cap 40 Ltrs/hr by cutting of suction and discharge lines and unscrewing the foundation nuts & bolts etc, supply and fixing new sealed compressor unit by tightening the foundation nuts and bolts and connecting suction and discharge line with gas welding work including supply and filling of refrigerant gas R-22 or as per existing at site in suitable quantity as per manufacturers instruction complete all as specified and directed. Note:- (i) Cost of transportation from store to factory and back shall be deemed to be included in the quoted rates. (ii) GI fitting damaged while taking out/fixing back water coolers shall be replaced by the contractor at his own cost. (iii) All new compressor shall be purchased from authorised dealer only. (iv) Capillary, drier, filter strainer are inclusive in unit rate.
All as per item No 112 above but water cooler of capacity 60 Ltrs/hr
All as per item No 112 above but water cooler of capacity 150 Ltrs/hr
M&L for replacement of Rubber hose pipe of 20 mm bore with clips for outlet tray of water cooler approximately 1.5 Mtr long complete
M&L for replacement of PVC sheet rubber bedding and lock of top cover of water cooler by screwing/welding MS sheet of top cover complete all as directed
M&L for making the system leak proof and charging of gas R-22 / R-134a or existing at site as required in water cooler of any capacity including replacement of drier and capillary tube and testing on load complete all as directed
M&L for scraping old painted surface of water cooler any capacity and painting with two coats of synthetic enameled paint including writing SM/MES No with black paint with minimum 25 mm size of letters as directed.
M&L for replacement of condenser fan motor of SP, 230V, cap 1/35 HP with fan blade all as directed
M&L for replacement of condenser fan motor of SP, 230V, cap 1/8 HP with fan blade all as directed
Supply and replacement of 15mm bore Push cock/lift cock brass chromium plated.
Supply and replacement of flexible PVC pipe 40mm/50mm/60mm as per requirement for the drainage of waste water of water coolers all as directed by Engnr-in charge.
Detection and rectification of leakage of storage tank of water cooler by brazing soldering/welding as required at site or at work shop testing for leak proof complete all as directed. Note : (a) Nipple adaptor if required deemed to be included in unit rate. (b) Push cock, float valve etc if required will be measured and paid separately. (c) Changing of rubber/plastic packing is incl in unit rate.
Taking out the drain tray with PVC pipe of water cooler, electroplating (chromium plating) of drain tray after repair by denting/painting and including replacement of new PVC pipe of suitable size and length and refixing back all as directed.
Supply only the following items for water cooler :-
Starting capacitor 60/80 mfd
Running capacitor 10 mfd
Thermostat
Relay
Over load protector
Wiring kit
Strainer/filter drum type/pen type
Door gasket
REFRIGERATORS
Repair maint of refrigerator of any capacity, cleaning of indoor panel, servicing of serviceable parts, replacement of worn out parts, testing for smooth functioning of refrigerator all as directed. Note : Replaced worn out part shall be measured and paid separately as supply only.
M&L for detection of leakage in refrigeration of capacity 260L/310L and repairing thoroughly to ensure the complete system leak proof and charging of refrigerant gas as per existing on site with appropriate quality including necessary brazing, welding, testing and commissioning complete all as directed by Engr-in-Charge. Note : Replacement of Capillary, drier and copper tubing/filter strainer are inclusive in unit rate.
Dismantling of unserviceable sealed compressor unit from refrigerator and replacing with new compressor as existing capacity and charging of refrigerant gas of appropriate qty and testing for smooth functioning complete all as specified. Note : (a) New compressor will be purchased from authorised dealer only. (b) Capillary, drier and additional copper tubing are included in unit rate. (c) Old compressor either cut open or sealed to be replaced with new one.
Supply only the following item for refrigerators as per sample :-
Thermostat switch as per sample
Relay box type as per sample
Door gasket as per sample
Cooling coil as per sample
Condensing coil as per sample
Freezer door any make
Door switch
Bulb Holder
Door Handle
Door Lock
Bottle holder shelves any size
Vegetable tray with cover
Main shelves
Printed circuit board for invertor type Refrigerator of capacity upto 320 Ltrs for existing model
DEEP FREEZER
M&L for Repair maint of deep freezer of any capacity, cleaning of indoor panel, servicing of serviceable parts, replacement of worn out parts, testing for smooth functioning of deep freezer all as directed. Note : Replaced worn out part shall be measured and paid separately as supply only.
M&L for making the system leak proof and charging of gas as required in Deep Freezer of any make of capacity up to 400Ltr including replacement of drier and capillary tubing and testing on load complete all as directed.
Supply and replacing Cable 3 core flexible heavy duty copper cable of size 2.5 sqmm for AC, Water Cooler ,Stabilizer etc. complete all as specified and directed.
Removing burnt/defective sealed compressor unit of any make from DEEP FREEZER of any capacity by cutting of suction and discharge lines and unscrewing the foundation nuts & bolts etc, supply and fixing new sealed compressor unit by tightening the foundation nuts and bolts and connecting suction and discharge line with gas welding work including supply and filling of refrigerant gas R-22 in suitable quantity as per manufacturers instruction complete all as specified and directed.
M&L for replacement of PVC sheet rubber bedding and lock of top cover of deep freezer of any type and by screwing/welding MS sheet of top cover complete all as directed
M&L for replacement of condenser fan motor of SP, 230V, cap 1/50 HP with fan blade for refrigerator or deep freezer all as specified and directed
Supply only the following item for Deep Freezer as per sample :-
Thermostatic switch for any capacity
Relay /capacitor any type for any capacity as per sample
Door gasket as per sample
Cooling coil as per sample
Condensing coil as per sample
VOLTAGE STABILIZER
M&L for opening unserviceable automatic voltage stabilizer for repair, detection of fault and its repair cleaning of serviceable parts, replacement/repair of unserviceable or worn out parts soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externally all as specified including sign writing "AGE E/M New Cantt" all as directed any make:-[Note: (a) Replacement of new parts/worn out parts in lieu of unserviceable/worn out parts shall be measured and paid separately.(b) The flexible 3 core cable, 40/.0076, 23/.0076, 70/.0076 to be provided at least 1.5 RM is included in unit rate.]
Capacity 5 KVA/4 KVA
Capacity 3 KVA.
Supply only the following spare parts suitable for automatic voltage stabilizer of any make and capacity :-
Volt meter (0-300 volts)
Control relay
IC controlled circuit for 5KVA/4 KVA
IC controlled circuit for 3 KVA
Control transformer
Low/high voltage cut off and TDR system
Main transformer for 5 KVA/4 KVA
Main transformer 3 KVA
M&L for rewinding of boost/buck transformer of stabilizer with copper wire of existing gauge and same number of turn with best quality insulating material including testing complete and refixing back electrically and mechanically all as directed and specified by Engr-in-Charge of following capacity :-
Capacity 5 KVA/4 KVA
Capacity 3 KVA
Schedule of Credit (MINUS) Rs. 129411.00 B/F from Serial Page No. [Note : Details of items for schedule of credit is given on Srl Page No. ] This amount shall be automatically deducted to arrive at tendered sum
PITAMBARI TRADERS (BID ID -3073229)
ARADHYA ENTERPRISES (BID ID -3078655)
M.R. ENTERPRISES (BID ID -3079376)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .