Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹40.7 L+₹5.8 L (16.6%)Rejected-Finance | L2 | Rejected-Finance Highest rate quoted | |
| 3 | L3₹41.2 L+₹6.3 L (18.1%)Rejected-Finance OPPOSITE J K BANK BAROO NH1 HAIDERY COMPLEX BAROO KARGIL BAROO KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | L3 | Rejected-Finance Highest rate quoted |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2022_MES_545182_1
8400-843/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
PANAGARH
Class D and category b (i) (Low Tension Electric Works (upto 1100 Volts)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹90,000
Yes
29 Nov 2022
13 Aug 2022
14 Sept 2022
13 Aug 2022
13 Sept 2022
27 Aug 2022
Amount
Excavation in trenches n.exc 1.5m wide and n.exc. 1.5m depth and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and exc. 1.5m depth n.exc 3.0m depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling, including spreading, levelling, watering and well ramming in layers n.exc. 25cm in soft/loose soil complete all as specified and directed.
Removal of excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and directed. (Note : Punned thickness shall be measured).
Dismantling/taking out carefully of old LT cable including bricks of any size type or core and kept aside for reuse/rerouting/jointing/replacement etc complete all as specified and directed
Laying only serviceable bricks for protection of cable obtained during excavation from item No. 5 here-in-before complete all as specified and directed.
M&L for fly ash compact modular bricks locally available of size 23 x 11 x 7 cm laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed.
M&L for 100 mm bore steel for tubing light grade ISI marked for protection of cable including necessary joint including taking down old unserviceable one complete all as specified and directed. (Make : TATA/JINDAL/BANSAL).
All as per item No 8.00 mentioned here-in-above but 40 mm dia complete all as specified and directed.
M&L for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32 mm x 6mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting (Inside cavity to be made in Pit for placing cover slab) made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR part 1 including testing on completion all as specified and directed incl demolition to existing one complete all as specified and directed. (Note :- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Testing to be carried out by the contractor in presence of Engr- in- Charge, entered in the earth testing register, prepared and to be maintained by the contractor & submitted to Concerned JE E/M. (iii) T&P and testing instrument(Meger) to be provided by the contractor at own cost).
M&L for Two coats of Aluminium paint after preparation of old surface of steel/Iron electric poles exc 10cm in width or girth including pole fittings with two coat of aluminium paint such as cross arms of any description anti climbing devices nut bolts etc and cement based paint of PCC coping and painting 05 Nos of strips of each 30cm height of Fluorescence Yellow & Black synthetic enamel paint alternatively above coping including numbering with Black colour paint on poles in two segments on yellow colour circular/rectangular block on aluminium paint complete all as specified and directed by Engr-in-Charge.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade cross sectional area 400 sq. mm 3½ Core complete all as specified and directed by Engr-in-Charge.
All as per item No 12.00 mentioned here-in-above but 300 Sqmm 3½ Core complete all as specified and directed
All as per item No 12.00 mentioned here-in-above but 240 Sqmm 3½ Core complete all as specified and directed
All as per item No 12.00 mentioned here-in-above but 185 Sqmm 3½ Core complete all as specified and directed
All as per item No 12.00 mentioned here-in-above but 150 Sqmm 3½ Core complete all as specified and directed
All as per item No 12.00 mentioned here-in-above but 120 Sqmm 3½ Core complete all as specified and directed
All as per item No 12.00 mentioned here-in-above but 95 Sqmm 3½ Core complete all as specified and directed
All as per item No 12.00 mentioned here-in-above but 70 Sqmm 3½ Core complete all as specified and directed
All as per item No 12.00 mentioned here-in-above but 50 Sqmm 3½ Core complete all as specified and directed
All as per item No 12.00 mentioned here-in-above but 25 Sqmm 4 Core complete all as specified and directed
All as per item No 12.00 mentioned here-in-above but 16 Sqmm 4 Core complete all as specified and directed
All as per item No 12.00 mentioned here-in-above but 16 Sqmm 2 Core complete all as specified and directed
All as per item No 12.00 mentioned here-in-above but 10 Sqmm 2 Core complete all as specified and directed
M&L for heat shrink type straight through jointing kit for 1.1 KV XLPE/PVC cables of size 6 to 16 Sqmm 4 core including testing after jointing complete all as specified and directed. (Make : Birla-3M/Denson/Raychem).
All as per item No 25.00 mentioned here-in-above but 25 to 50 Sqmm 4 Core complete all as specified and directed
All as per item No 25.00 mentioned here-in-above but 70 to 120 Sqmm 4 Core complete all as specified and directed
All as per item No 25.00 mentioned here-in-above but 150 to 185 Sqmm 4 Core complete all as specified and directed
Painting of outdoor/indoor Feeder Pillar Boxes of MS Sheet with spray gun after scrapping old surfaces any size complete all as specified and directed
S&F in repair polycarbonate distribution board of Size 300 x 300 x 170 mm with lids/ hinged doors with opening for MCCB operation, if required including taking down unserviceable old one complete all as specified and directed.
S&F in repair polycarbonate distribution board of Size 300 x 450 x 170 mm with lids/ hinged doors with opening for MCCB operation, if required including taking down unserviceable old one complete all as specified and directed.
S&F in repair polycarbonate distribution board of Size 300 x 600 x 170 mm with lids/ hinged doors with opening for MCCB operation, if required including taking down unserviceable old one complete all as specified and directed.
S&F in repair polycarbonate distribution board of Size 600 x 600 x 170 mm with lids/ hinged doors with opening for MCCB operation, if required including taking down unserviceable old one complete all as specified and directed.
M&L for mild steel work for doors of LT feeder pillar boxes with Fe 410 or Fe 310 including joint/hinges with panel including painting and taking down old unserviceable one complete all as specified and directed.
S&F in repair PVC Connector/terminal Post type/strip type upto 400A capacity suitable for Metal/ Polycarbonate feeder pillar including connection after taking down old unserviceable one complete all as specified and directed
S&F in repair Digital Voltmeter 0-500 V range including connection with metering system and taking down old unserviceable one complete all as specified and directed
S&F in repair Digital Ammeter 0-400 A range including connection with metering system and taking down old unserviceable one complete all as specified and directed
S&F copper Busbar rating as required Amps including making Holes for connections and colour coding as per existing busbar including taking down old unserviceable one complete all as specified and directed
S&F in wiring Single core stranded Copper conductor FRLS of size 50 sqmm including copper lugs at both ends complete all as specified and directed
S&F in wiring Single core stranded Copper conductor FRLS of size 25 sqmm including copper lugs at both ends complete all as specified and directed
S&F in wiring Single core stranded Copper conductor FRLS of size 16 sqmm including copper lugs at both ends complete all as specified and directed
S&F in wiring Single core stranded Copper conductor FRLS of size 10 sqmm including copper lugs at both ends complete all as specified and directed
Isolate, disconnect, dismantle the burnt out lugs from main switches/ MCCB/ ACB/ Breakers and S&F new lugs with crimping tool as per existing one including fixing, insulation, termination to main switches/ MCCB/ ACB/ Breakers for following sizes of cables complete al as directed by Engr-in-Charge:- (a) 06 sqmm to 16 sqmm.
(b) 25 sqmm to 50 sqmm.
(c) 70 sqmm to 95 sqmm.
(d) 120 sqmm to 240 sqmm.
(e) 300 sqmm to 400 sqmm.
S&F in repair ACB Manual Draw out type 4 polem Microprocessor Based , 415 V adjustable type 800 Amps, with breaking capacity 50 KA including spreader link and separator and any modification required for fixing of ACB including taking down old unserviceable one complete all as specified and directed. (Make - ABB/ Siemens/ Schneider)
S&F in repair MCCB 4 pole, 415 V adjustable type 320 Amps, with breaking capacity 50 KA including spreader link and separator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as specified and directed.
S&F in repair MCCB 4 pole, 415 V adjustable type 250 Amps, with breaking capacity 36 KA including spreader link and separator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as specified and directed.
S&F in repair MCCB 4 pole, 415 V adjustable type 200 Amps, with breaking capacity 36 KA including spreader link and separator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as specified and directed.
S&F in repair MCCB 4 pole, 415 V adjustable type 160 Amps, with breaking capacity 36 KA including spreader link and separator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as specified and directed.
S&F in repair MCCB 4 pole, 415 V Fixed type 100 Amps, with breaking capacity 16 KA including spreader link and separator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as specified and directed.
S&F in repair MCCB 4 pole, 415 V Fixed type 63 Amps, with breaking capacity 16 KA including spreader link and separator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as specified and directed.
M&L for drilling hole horizontally road under (min 1 mtr) pavement hardstanding by trenchless technology using ultra sound technique and necessary machine suitable and including 150 mm dia HDPE pipe complete all as specified and directed .
S&F metal cable route indicator of height 600 mm MS Flat of 40 mm x 4 mm with Circular 100 mm diameter MS Sheet of minimum thickness 3 mm duly engraved "LT CABLE" including Aluminium paint over it and to be fixed 150 mm below ground level with PCC (1:3:6) (using 40 mm graded stone aggregate) of size 250x250x300 mm complete all as specified and directed by Engr-in-Charge.
Dismantling existing steel poles/ struts, any size carefully for reuse including necessary excavation demolition of concrete transportation cost etc. and removing the old unserviceable rubbish etc complete all as specified and directed
M&L for Steel tubular swaged poles complete with cast iron/MS base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22, 8.5 meter long complete all as specified and directed. (Note: PCC anti climbing device, cross arms insulator, ACSR conductor and earth work measure and paid separately)
M&L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in foundation for stay set /Pole/ Panels etc including fair finish even and smooth to exposed surfaces without using extra cement complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (with using 20 mm graded stone aggregate) as coping of pole/panel including necessary form work as required complete all as specified and directed
M&L for brick in CM (1:4) rendering using sub class B bricks straight or curved on plan exceeding 6 Mtr mean radius including dismantling old structure complete all as specified and directed.
M&L for 15mm thick in cm (1:4) rendering on fair face of brick work finished even & fair complete all as specified and directed.
S&F PVC spring type locks for Polycarbonate Body Panels complete all as specified and directed
S&F Metal Rotary type locks for CRCA Sheet Panels complete all as specified and directed
S&F Current Transformer for Amps n.exc 400 Amp for suitable ratio as existing including wiring with Ammeter complete all as specified and directed
M&L for Hardcore of gauge n.exc. 63 mm, deposited, spread and levelled in layers n.exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed
S&F Earth continuity conductor of size 32 mm x 6 mm GI strip fixed to wall on batten or recess with porcelein insulators or chases or buried in ground or drawn in conduit/pipe or fixed to poles with porcelein insulators or any other indicated situation for earthing etc complete all as specified and directed
SARASWATI ENTERPRISE (INDEX NO CEEC D-81)
M/S Ali Trading Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .