| 1 | L1₹8.1 LAccepted-AOC | L1 | Accepted-AOC SINCE L1 | |
| 2 | L2₹8.1 L+₹1,066 (0.13%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L2 | Rejected-Finance SINCE NOT L1 | |
| 3 | L3₹8.4 L+₹33,617 (4.15%)Rejected-Finance NO 26 GURU AMARDAS COLONY BHAINSA NAKA SAGAR MADHYA PRADESH 470001 | SAGAR | MADHYA PRADESH | 470001 | L3 | Rejected-Finance SINCE NOT L1 | |
| 4 | L4₹9.4 L+₹1.3 L (16.3%)Rejected-Finance PLOT NO 106 MIDC SATPUR SATPUR MIDC AREA SATPUR NASHIK MAHARASHTRA 422007 UDYAM MH 23 0018515 | NASHIK | MAHARASHTRA | 422007 | L4 | Rejected-Finance SINCE NOT L1 | |
| 5 | L5₹9.8 L+₹1.6 L (20.3%)Rejected-Finance | L5 | Rejected-Finance SINCE NOT L1 |
Tender Value
Refer Docs
EMD Value
₹20,800
Closing Date
4 Nov 2020, 6:00 pmClosed
GE DEOLALI
GE DEOLALI, 422401
PROVN OF 12X SECURITY LED LIGHTS AT 2142 RKT BTY LOC, CERTAIN E/M REVENUE AND MINOR WORKS UNDER THE AOR OF GE DEOLALI
2020_MES_384055_1
8877/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE DEOLALI
class E Cat b i
8 documents required · 8 mandatory
₹500
GE DEOLALI
₹20,800
Yes
30 Dec 2020
7 Oct 2020
7 Nov 2020
7 Oct 2020
4 Nov 2020
21 Oct 2020
Amount
Excavation in trenches in any type of soil n.exc 1.5 mtr in depth and n. exc. 1.5 mtr in width in foundation / for taking out / laying cable / errect poles including getting out.
All as per serial item No.1 above but depth exceeding 1.5 meter and not exceeding 3.00 meter
Removing excavated material not exceeding 50M and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
M&L for Cable Flexible 3 Core 1.0 Sqmm PVC Insulated with stranded copper conductor for connecting up the street light fitting.
M & L for unwashed river sand cushioning for protection of LT/HT cable. Note:-For the purpose of payment punned thickness will be measured.
M & L sub class 'B' bricks well burnt for protection of LT cables.
M & L for bracket made out of GI tubing 40 mm dia,light grade 1.5 mtr long including fixing with MS clamps -2 Nos made out of 50mm wide 5mm thick flat iron with M.S nuts bolts 75 mm long 12 mm dia -4 Nos & flat washer (3mm thick) -01 No for each including painting with aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete.
Supply and laying in trench LT U/G cable PVC insulated, sheathed armoured 10 Sqmm 4 core having aluminium stranded conductor including making connections etc complete.
Supply and laying in trench LT U/G cable PVC insulated, sheathed armoured 10 Sqmm 4 core having aluminium stranded conductor including making connections etc complete.
S&F PVC junction box of size2 80x170x100 mm thick (Sintex or National make) with MS clamp of size 25 mm wide 4 mm thick with necessary nuts, bolts& washers 1 set and one No MCB SPN-10 Amps
Excavating in post hole size 0.6 Mtr X 0.6 Mtr X 1.65 Mtr depth for installation of LT pole 9 mtr long ,in any type of soil and getting out, removing, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm.
Supply Install and errect in true vertical position steel tubular swaged poles 9 m long complete with MS base plate of 6mm of size 300mm X300mm finial taper plug,pole cap,bolts,nuts and washers screws,pole made out of ERW MS tubing as per IS-1161 and pole shall be as per IS-2713 Part II type 410SP-31 (9.00 Mtrs Long) complete including one coat of red oxide primer and two coats of Aluminium paint for exposed surfaces and two coats of Back bitumenous paint for portion embedded in concrete complete all as specified and directed(Note: excavation earth work in any strata,PCC in foundation plinth block/coping shall be measured and paid separately
M&L for cement concrete 1 : 4 : 8 type D-2 using 40 mm graded aggregate as in foundtion for pole including necessary form workall as specified and directed
M&L for plain cement concrete (1:2:4.) type B1 for plinth blocks for LT poles etc using 20 mm graded coarse aggregate including fair finishing the exposed surfaces even and smooth without using extra cement and necessary form work all as specified
M&L for tubes Galvanised Light Grade 40 mm bore for encasing of cable as mechanical protection laid under plinth/floors/roads/paths/culverts/for protection of earth strip or fixed to walls or along the poles including suitable size of MS Clamps 40X 5mm with necessary bolts nuts washers etc complete
M&L for 60 Watt die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device. Make- Havells, Model -ENDURA PEARL PLUS SL60WLED757SASYTOPC. or equivalent in Philips/Wipro/Bajaj
a) Aluminium bus bar capacity 200 Amps for Phase-R-Y-B-3 Nos & 150 Amps for neutral -1 No . Neutral link-01 No b) MCCB TPN 25 KA ,100 Amp - 1 No (I/C) c) MCB TPN 63 Amps 10KA - 1 No d) MCB SP 32 Amps-03 Nos e) Timer with synchronous timer 0-24 Hrs( daily Dial type)( L&T- J648B1) suitable for street light control and with 70 Amps MO70 contactor( L&T) 3Ph phase 70 Amps capacity - 0 1 Set
M&L for earthing GI Strip complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified. Note: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
Supply, erection and fixing in true vertical position steel tubler swaged pole 11 mtr long type (410-SP-55) conforming to IS -2713 (part 1 and 2) - 1980 complete with cast iron base plate, pole cap, MS bolts, nuts and screws, welded and reduced section and lonitudinal weld seam throughout entire length of pole including material and labour for 2 coats of black bituminous paint throughout internally and externally upto planting depth and remaining exterior position of pole with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Plain cement concrete (1:3:6) typeC-2 using 40 mm graded crushed stone aggregate as in foundation / stay assembles etc. complete all as specified
Mild steel Cross arms bracing supports , clamps and back plate fabricated frame structural steel section including nuts , bolts , washers , welding , binding , cold or hot , drilling hole for bolts in any shape or size indicated or directed and inclusive of one primer coat and one finishing coat of alum. Paint complete all as specified and directed.
Material and labour for point wiring with stranded copper conductor PVC insulated unsheathed 1.5 Sqmm FRLS cable in and including PVC casing caping of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow,Tee,collers bend, PVC conduit for crossing etc. complete with PVC terminals box for mounting switches, sockets, fan regulators etc with one single core continuous 1.5 Sqmm,FRLS copper cable for earth wire complete all as specified and as directed for :-(a) One fan/ Exhaust fan point controlled by one switch
Supply and fix switch piano flush type single pole one way 5 Amps complete all as specified and directed.
Supply and fix exhaust fan, Plastic body 200mm sweep, with all accessories including frame work in exiating window and electric connection all as specified and as directed. Havells Venti air DX White/ Eqvt from CG/ Bajaj.
Supply, installation and commissioning of Storage type electric water heater, Star rated energy saving, single phase, 230 volts, 50Hz, verticaly mounted, having storage capacity of 25 Litres and kilo watt rated of 2 KW including necessary nut and bolt for fixing in the wall all as specified and as directed Make: Havells model :- Puro Turbo Cat Part No. :- GHWAPTTIV025 or equivalent in / Bajaj / CG
S & F in Plug & socket enclosure in sheet metal enclosure with 20A SP MCB complete all as specified and as directed.
M & L for sub main wiring with 2 single core, 4 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FR cable 1100 Volts grade including 2.5 Sqmm PVC insulated unsheathed multi stranded copper conductor FR as continuous earth wire drawn through Casing caping and connecting to common earth terminals complete all as specified and directed. Note :- (i) Two runs of copper cable and one run of earth wire including conduit /PVC casing/caping shall be measured as one length.
Material and labour for point wiring with stranded copper conductor PVC insulated unsheathed 2.5 Sqmm FRLS cable in and including PVC casing caping of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow,Tee,collers bend, PVC conduit for crossing etc. complete with PVC terminals box for mounting switches, sockets, fan regulators etc with one single core continuous 2.5 Sqmm,FRLS copper cable for earth wire complete all as specified and as directed for :-(a) One 5 pin 15 amp socket outlet on independent board
Supply and fix PVC flexible outlet pipe 60cm long heavy duty suitable type for hot water application of 12mm bore with brass coupling, nuts, washers at both ends complete all as specified and directed.
S & F stop cock cast copper alloy both ends screwed suitable for 15mm bore complete all as specified and directed.
M & L for steel water tubing of 15mm bore medium grade galvanised with all fittings to wall and ceiling or laid in trenches complete all as specified and directed.
M & L for stud / anchor fastener minimum of suitable size with washer for fixing geyser of any capacity in and including making good to disturbed surfaces complete all as specified and directed.
S & F bib cock cast copper alloy of size 15mm dia complete all as specified and directed.
Note: Amount of sch of credit of Rs.NIL/- will be deducted from total amount of BOQ.
Rama Electricals
Veer Brothers
KOYNA ENGINEERS PVT LTD
YASHASVI ENGINEERS
M/S S.N ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .