CWA III
Okhla Sewage Treatment Plant Mathura Road Delhi 110024
NIT No. 11 Item No.1
2021_DJB_213786_1
NIT No. 11
Open Tender
Miscellaneous Works
Works
45 days
Okhla Sewage Treatment Plant Mathura Road Delhi
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Allahahabad Bank
₹19,000
Yes
7 Feb 2022
30 Dec 2021
15 Jan 2022
30 Dec 2021
15 Jan 2022
30 Dec 2021
Specification for Digital burette (electronic) The burette will be electronic type and will have two components: 1. Bottle top burette 2. Touch screen control panel The Burette will be constructed with chemical resistant material The burette will be provided with amber colored window on demand to perform light-sensitive media titration. The burette should have adjustable dispensing tube in both horizontal and vertical directions. The burette should have telescopic filling tube to adjust the length depending on the depth of the bottle. Technical Specifications for Bottle top burette: 1. The bottle top burette should have motor-controlled piston movement. 2. There will be different speed modes a. Fast b. Medium c. Slow to control dispensing speeds and to facilitate accurate titrations. 3. Bottle top burette should be able to dispense a droplet as small as 0.01 ml to ensure highly accurate end point. 4. It will have re-circulation mode that allows quick purging without loss of reagent. to provide ease of use and save time, the burette should provide one-touch filling operation and refilling should be done without change in on-screen reading. 5. Capacity: 50 ml 6. Increment: 0.01 ml 7. Systematic Error: Precise titration with the error limits of Class A; ≤ 0.1% at nominal volume 8. Random Error: ≤0.02% at nominal volume 9. Technical Specifications of Touch screen control panel base unit The touch panel will have monochromatic or colored touch screen TFT display to show the readings. The panel will have interactive Graphical User Interface. It should have buttons like: Titrate, Fill, Stop, Purge and Tare (Zero Reset) to perform different operations. The panel will have separate button for ON/OFF. It will have rechargeable batteries. The batteries should preferably be present in a separate entity than the bottle top burette having the piston system arrangement. This would enable the user to change the batteries without affecting the accuracy or calibration of the instrument. Memory: 20 readings and Quick recall feature to show the last titration reading on the display screen. Connectivity: The control panel can be connected with computer with micro USB cable Deliverables: (a) Instrument should be supplied with an operation manual with clear pictorial description of all the operations like setting up the instrument, getting started, operational limits and exclusions, maintenance & calibration of the instrument etc. (b) A set of 5 adapters of the sizes: 28 mm, 32 mm, 38 mm, 40 mm & 45 mm (c) A hand held stylus (d) Micro USB cable Warranty: Two years The instrument should be supplied with calibration certificate for each individual instrument with identification number. Make:- Sartorius, Brand, Thermo Fischer Scientific, Borosil, Microlit
R.P.D. Enterprises
MAZELINOV SOLUTIONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .