Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹34.3 LAccepted-AOC VILLAGE CHANNI POST OFFICE SATTANI DISTT UDHAMPUR UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | 1 | Accepted-AOC BEING LOWEST TENDERER | |
| 2 | 2₹39.9 L+₹5.6 L (16.2%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | 2 | Rejected-Finance BEING L2 | |
| 3 | 3₹40.6 L+₹6.2 L (18.0%)Rejected-Finance 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | 3 | Rejected-Finance BEING L3 | |
| 4 | 4₹40.7 L+₹6.3 L (18.3%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | 4 | Rejected-Finance BEING L4 |
Tender Value
Refer Docs
EMD Value
₹82,700
Closing Date
10 Feb 2023, 6:00 pmClosed
GE AF UDHAMPUR
AIR FORCE STATION UDHAMPUR
ADDN/ ALTN IN STATION GYMNASIUM TO ACCOMMODATE MODERN GYMNASIUM FACILITY AT AIR FORCE STATION UDHAMPUR
2023_MES_575008_1
GEAFU-67/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
AF STATION UDHAMPUR
Ref tender documents
8 documents required · 8 mandatory
₹500
GE AF UDHAMPUR
₹82,700
Yes
11 Mar 2023
14 Jan 2023
13 Feb 2023
14 Jan 2023
10 Feb 2023
28 Jan 2023
Amount
SCHEDULE "A" PART-I (E/M ) .
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 2.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC conduits, with new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 2.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified.
Supply and fixing of switch socket combination 16/20 Amp, flush type complete all as specified and as directed.
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified.
S&F Switch piano type 6 AMP, SP one way , complete all as speciifed and as directed
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit heavey duty drawn through PVC surface/concealed conduit and connected to main board and making good disturbed surface and disposing from site complete all as specified and as directed. Note: Two runs of 6.00 sqmm main cable and one RM of 6.00 sqmm earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit heavey duty drawn through PVC surface/concealed conduit and connected to main board and making good disturbed surface and disposing from site complete all as specified and as directed. Note: Two runs of 4.00 sqmm main cable and one RM of 4.00 sqmm earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
M&L Wiring for circuit 2 core 2.5 sqmm copper conductor PVC insulated PVC sheated as per is 694 up to date all including drawing through PVC Conduit making connection with LED BuildingFlood Light / Bulk Head light fitting up to 20 mtr height bracket,fastners ,screw nut bolt etc complete all as specified and as directed by enginer in charge Note : Light fitting shall be connnected each fitting shall be connnected with ceiling rose and junction box /PVC connector etc shall be included in the quoted rate ie Nothing shall be paid extra amount to the contractor .
Supply and fixing LED flood light 100 watt 230 V AC, 100 lm/watt, CRI 80, pf>0.90 outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all including clamp etc & directed by engr-in-charge.
Supply and fixing Building security LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Sheet metal enclosures for Duble Door SPN 8 way (when MCBs to be used) flush mounted including taking down existing unserviceable DBs /board /box including accessories therein and disposing off complete all as specified and directed. Make:Legrand/HAVELLS / Schneider
S&F MCB SPN 32 Amps 240 V, 10 KA 'C' curve complete all as specified and as directed
Supply and fixing miniature circuit breaker (MCB) SP 6- 32 Amps, 240V 10KA 'C' curve complete all as specified and directed
Supply and fixing miniature circuit breaker (MCB)TPN 40 Amps, 415V 10 KA 'C' curve complete all as specified and as directed.
Supply and fixing miniature circuit breaker (MCB)TPN 63 Amps, 415V 10 KA 'C' curve complete all as specified and directed
Earthing complete with steel earth plate electrode of size 60 cm x 60 cm x 06 mm thick as earth electrode burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using GI earth strip 25 x 4 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion.
Supply and fixing of Earth continuity conductor or main4mm dia iron strip or main earthing lead fixed to wall on batten or recess or chases including plastic type insulatoror buried inground or drawn in conduit/pipe orfixed to poles or any other indicated situation for loop earthing etc. all as required and including taking out old unsv up to building height .complete directed by Engr-in-Charge
Supply and fixing steel body exhaust fan, AC single Phase. 230V of size 450m sweep with, blades, and frame and louvers complete including making suitable size hole in wall and making good surface civ works with fastner,screw,nuts bolts etc Complete all as specified and as directed by Engineer in charge.
M&L of LT panel in door type cubical floor mounted type made out 2.0mm thick CRCA Sheet duly powder coated complete bus bar 400 Amps rating made of Aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 Wire 415 volts 50HZ Power suply system suitable for and including the following :- (a) MCCB 415 Volts 200 Amps 4 Pole with Reputing CAP for over load short circuit protation : 01 Nos incoming (b) MCCB 415 Volts 100 Amps 4 Pole with Reputing fixed type based for over load short circuit protation : 02 Nos OUTGOING (c) All acessories prewired with suitable size copper conductor cable/strip and suitable foundation as per manufactors recommendation (d) Indicator set RYB 01 Set 3 pcs LED type Note : including site clearance /earthwork with PCC sub base and brickwork of platform with external platform complete all as specified and as directed.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 95 Sqmm 3.5 core laid on walls/floors or in air with saddles and gutties complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth, for foundation, laying of pipes and LT cable and getting out, , complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each in any type of soil , complete all as specified and directed by Engineer-in-Charge
Removing excavated spoil (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed by Engineer-in-Charge
Dry sand cushioning to under ground cable all as per clause 19.75 of SSR Part - I laid before and after laying of cable, complete all as specified and directed by engr-in-charge.
Sub class 'B' old size bricks well burnt as covering to under ground cables , laid dry, flat over the cables on sand cushioning with width equal to length of the brick as mechanical protection to cable in repair , complete all as specified and directed by Engineer-in-Charge
M & L for PCC 1:4:8 type D2 (Using 40 mm graded stone aggregate) in foundations, filling and mass concret, complete all as specified and directed.
S&F 80 mm dia GI tubing,light grade,for protection of cable passing across the road,under floor etc,complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (Using 12.50 mm graded stone aggregate) as in copings etc complete all as specified and directed by Engr-in-Charge
Material and labour for MCCB 4 Pole, 415 V, adjustable type, thermal magnetic load, ICS 100 of ICU, 0.8 ln to 1 ln, 125 Amps with breaking capacity 16 KA as per IEC 60947-2 including all accessories all as specified and directed by Engr-in-Charge.
Supply and fixing of Vertical three phase distribution board, VTPN, 08 way 440 volts having IP-54 IK 09protection, double door with provision for fixing of 125 Amps MCCBs as incomer and SP/TP/MCBs as outgoing complete.With 250AmpsCopper Busbar for each phase after taking down existing unservicable main switch, busbar, GI box including accessories therein & disposing from site complete all as specified and as directed.Make:CAT PART NO:507680 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
SCHEDULE 'A' PART-II (B/R)
Dismantling boarding, any description, fixed on floor wih screws complete all as specified and as directed
Dismantling wall and ceiling board (fibre, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness, including cover fillets at a height 10 to 20 mtr from average ground level complete all as specified and as directed
Demolition of plain cement concrete in ground floors and pavings n. exc 15cm thickness (below or above ground level) complete all as specified and as directed
Material and labour for 25mm thick PCC flooring 1:2:4 type B0 (using 12.5mm graded aggregate) laid below wooden flooring including finish and surface fair and even complete all as specified and as directed
S&F wooden flooring with 21mm thick eak wood planks (i.e. African imported) grade AB of size 450mm to 1500mm length and 50mm to 90mm wide fixed over treated pine runner of size 70mm x 45mm laid over existing subbase of floor @ 350mm c/c in bothways. The wooden runner to be treated with anti termite chemical. The wooden runners to be fixed with existing subbase of floor by suitable fastener at the interval of 500mm C/C. The planks to be joined to each other with tongue and groove method and fixed to wooden runner by screws and glue. The wooden runner to be fixed on 10mm thick rubber air cushioned pads stappled through the two wings @ 350mm c/c in bothways. The top surface of wooden flooring finally finished with PU polishing water based polyurethane lacquer complete all specified and as directed
Supply and fixing 21mm thick teak wood planks (i.e African imported) grade AB of size 450 to 1500mm length and 50 to 90mm wide fixed to wall with necessary screws as in skirting including finish the top surface with PU polishing water based polyurethane lacquer complete all as specified and as directed
S&F plain tile false ceiling on 24mm 'T' framework of module 600mm x 600mm at a height 10 to 20 mtr from average ground level. Panel shall be manufactured of size 575mm x 575mm made out of 0.50mm TCT thick GI (Galvanised steel) powder coated of not less than 55-60 micron in white colour. Grid system for fixing ceiling tiles shall be comprises of Tees. The 24mm main tee runners of size 3000mm shall be suspended at an interval of 1200mm c/c. The 24 mm cross runners of size 600mm shall be suspended at 600mm c/c and further supported with 24mm cross tee at 600mm c/c with interlocking arrangement form grid of 600mm x 600mm. The main tee shall be supported by means of 4mm GI rod from slab/ roof with the help of anchor. The suspension shall be provided at 1200mm C/C complete all as specified and as directed Make - OCULUS Building products Pvt Ltd or any equivalent.
Supply and fixing anodized aluminium powder coated of any colour (thickness of powder coating not less than 50 micron), in frame for doors, window, ventilators, partition wall etc, with one or more rebates, including joining cleat for fixing etc. complete all as specified and as directed
Supply and fixing anodized, powder coated aluminium doors shutters, (thickness of powder coating not less than 50 micron) aluminium section weighing exc 0.55 Kg/m including necessary joining cleats, glazing clips rubber neoprene packing, handle 2 nos in each door, fixed with floor hinges/ spring (measured separately), 4 lever brass nortice lock vertical type (1 No), anodised aluminium snap beading screws etc complete all as specified and as directed
Supply and fixing 5.5mm tinted sheet glass in square exc 0.5 sqm in each pane fixed to aluminium door complete all as specified and as directed
Supply only double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed
S&F rubber beading for fixing of glass in aluminium framework complete all as specified and as directed
S&F 18mm thick PVC particle board both side laminated fixed to aluminium framework complete all as specified and as directed
M&L for mild steel framed work such as grills, gratings , etc with ends of bards shouldered and/ or riveted, or forged into spikes framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe. 290 Gde-E-165 complete all as specified and as directed
S&F rolled mild steel plates (plain or chequered) as per IS-3502 (Base IS-10748 Gr-II) square or rectangular cut or notched (ordinary and counter shunk) forming holes, without any attachment complete all as specified and as directed
S&F 2nd class hardwood boarding 30mm thick, planed one side with butt joint in any position (except flooring and skirting) complete all as specified and as directed
M&L for applying two coats of synthetic enamel paint over a coat of pink primer on new wooden surface exceeding 10cm width of girth) complete all as specified and as directed
M&L for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel surface exceeding 10cm width of girth) complete all as specified and as directed
M&L for cutting holes of superficial area n. exceeding 150 sqcm into or through brick walls built, in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and as directed
Taking down chowkats or frames with shutters (without taking off shutter from the frames) not exceeding 1.5 sqm each including steel window, ventilators etc complete all as specified and as directed
M&L for rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fasterning and fixing conforming to Fe 410-W (Gde-E-250) quality-A complete all as specified and as directed
S&F 1mm thick mild steel, plain, black sheet for covering to door shutters; covering to door chowkats (frames), chullah hoods, water tanks, water troughs, ducts, urinal troughs and funnels, etc cut to size edges beaded if directed, holes punched, incluidng round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and as directed
M&L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in block for fixing of hold fast, window cill and similar items including necessary formwork complete all as specified and as directed
M&L for 15mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces including finish the surface even and smooth without using extra cement and applying three coats of white wash on new wall surface after preparation complete all as specified and as directed
M&L for applying one coat of oil bound distemper on old wall surface including preparation complete all as specified and as directed
M&L for applying two coats of synthetic enamel paint over a coat of pink primer on wooden surface n. exceeding 10cm width or girth including preparation complete all as specified and as directed
DAVINDER SINGH
SHIVAE CONSTRUCTION
ANIKET TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .