| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.9 L+₹1.4 L (5.35%)Rejected-Finance KILA ROAD 00 00 00 NARNAUL HARYANA 123001 | MAHENDRAGARH | HARYANA | 123001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹28.0 L+₹1.6 L (5.97%)Rejected-Finance H NO 29 DEVILAL COLONY TCP 2 HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹29.7 L+₹3.2 L (12.1%)Rejected-Finance | L4 | Rejected-Finance Being L4 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
23 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Hisar
HQ CWE Hisar, Military Station Hisar-125006
CWE/HSR-15 OF 2021-22 PROVN OF 11 KV INTERCONNECTION SYSTEM AND ALLIED SERVICES AT EBS HISAR AT HISAR MIL STN
2021_MES_482946_1
CWE/HSR-15 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
Hisar Military Station
As per tender documents
9 documents required · 9 mandatory
₹500
Yes
GE (West) Hisar
₹60,000
Yes
22 Dec 2021
21 Oct 2021
30 Nov 2021
21 Oct 2021
23 Nov 2021
9 Nov 2021
60 days
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cable etc. and for foundation of poles, stays etc. n exc 10 sqm on plan and n exc 1.5 in depth and getting out complete all as specified.
Description all as per Serial item No 1 above but depth exceeding 1.5 mtr and not exceeding 3.00 mtr.complete all as specified and directed.
Returning filling with earth obtained from excavation including spreading, watering & consolidation in layers not exceeding 15 cms thick, complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 m & depositing at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material & labour for Sand filling in trenches with clean dry fine sand unwashed including gently punning around cables complete all as specified and directed. (Note :- Punned thickness of sand will be considered for payment purpose)
Material & labour for bricks covering to under ground electric cable using sub class 'B' bricks laid dry, flat, perpendicular to the direction of the cable complete all as specified and directed.
Supply errecting & fixing in true vertical position pre stressed concrete pole conforming to IS-1678 of 11 mtr long , 152 mm x 152 mm at top and 152 mm x 260 mm at bottom,class 9 complete as specified & directed (Note : Earth work & PCC shall be measured and paid separately)
Material & labour for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate . in mass concrete and filling complete for foundation of pad of pole all as specified & directed.
Material & labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate . in mass concrete and filling complete for foundation of Panel & Transformer yeard, pole/stay/ of pole all as specified & directed by Enge-in- Charge
Material & labour for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate in coping for replacement of new pole and like including weather slightly rounded or chamfered angles and throaty and necessary form work complete for pole ,all as specified and directed .
Material & labour for GI HT Stay assembly set comprising of 20 mm dia 400 mm iron stay bow, 2150 mm long stay rod 16mm dia stay plate 300 x 300 x 8 mm thick, GI stay wire 7/8 SWG of required length and loop insulator complete with all aceessories as shown in electric plate no 1 of MES scheledule Part I complete. Note :- Earth work, PCC,stay clamps, will be measured separately.
Supply and fixing Aluminium conductor steel reinforced (ACSR) of any size for HT/LT OH lines on poles including stringing ,binding with aluminium wire or aluminium tape incl jumpers complete all as specified and directed.
Supply and fixing insulators pin type porcelain, vitreous ,white or brown or green insulator of size 150 mm height, 150 mm dia suitable for 11 kV grade including one galvanized mild steel spindle, two GI washers and one nut complete all as specified and directed.
M&L for Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts,bolts, washers and welding in two halves made to shape to suit thecross section of the pole complete.
Material & labour for making cradles, hexagonal/Rectangular, fabricated with galvanized steel wire 4 mm dia including stretching, sagging and jointing in position and also as a continuous earth wire on pole and for guarding complete all as specified and directed.
Material & labour Cross Arms bracings supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps stay clamps, D clamps nuts, bolts , washers,welding, bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Supply installation, connecting and testing gang operated air break switch, mounted on insulators HT 11KV 200 Amps rating , triple pole,twelve insulator suitable for horizontal mounting fixed and spring loaded revolving tinned brass/copper copper contacts, galvanized steel base frame, 25/32 mm bore medium grade pipe Galvanized operating rod, operating handle, locking arrangement complete all as specified and directed. (i) Cross arms of 2 pole/4 pole structure reqd for installation of GO switch,if reqd additional, shall be measured and paid seperately. (ii) Scope of wk shall include ACSR conductors PVC sleeves, PG clamps and thimbles reqd for jumpers/connections to OH lines of 2 poles/ 4 poles structures and outgoings feeders.
Material & labour lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amps 11000 volts complete including taking down the existing lightening arrestor complete all as specified and directed.
Supply and installation drop out fuse assembly 11KV,25 Amps rating complete expulsion fuse element mounted on four/two pole structures all as specified and directed.
Supply and fixing in replacement of single Disc insulator assembly for tension with tension clamps for conductors, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green with tension clamps for conductors, working pressure 11 kV for disc assembly complete,all as specified and as directed.
Material & labour for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled Red, with letters, figures, and coventional skull and bones, in signal white colour and fixed with MS CLAMPS, bolts, and nuts of approved size, for HT 25 X 20 Cm size complete all as specified and directed.
Prunning/trimming the branches of trees if any along HT/LT overhead line, 3 mtr on all side below/above/sides of HT/LT overhead line and removing the same upto 150 mtr away each span not exceeding 60 mtr complete all as specified and directed by Engineer-in-Charge (The above is to be ensured for the entire contract period by cutting/trimming of trees any number of times as required).
Supplying laying, jointing, testing and commissioning of XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 11000 volts grade, cross sectional area 95 Sqmm 3 core suitable for 11 KV earthed systems complete all as specified and directed by Engr -in-Charge. (Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc . Excavation, earhtwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid separtely) .
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination,cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE,armoured,Al conductor cable of size 95 sq.mm. indoor/outdoor type
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination,cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE,armoured,Al conductor cable of size 95 sq.mm. indoor/outdoor type
Supply and fix cable jointing kit for 11 KV grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE,armoured,Al conductor cable of size 95 sq.mm. indoor/outdoor type
Material & labour 80 mm bore GI pipe light grade laid in trenches or fixed to wall/pole for protection of cable/earthing strip etc complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode size 600x600x6.3 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron strip 32 x 6 mm as earthing lead upto 7.50 mtrs by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 40 mm dia connected to main earth lead on pole or control board and GI pipe light grade 20 mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion.
SAINI ELECTRIC STORE
M/s Devendera construction
S K CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .