| 3 | Admitted-Fee/PreQual/Technical PLOT NO DSS 170 HUDA SHOPPING COMPLEX SECTOR 31 FARIDABAD FARIDABAD HARYANA FARIDABAD HARYANA 121003 | FARIDABAD | HARYANA | 121003 | Admitted-Fee/PreQual/Technical |
Tender Value
₹22.1 L
EMD Value
₹44,232
Closing Date
5 May 2026, 3:30 pmClosed
Executive Engineer
Electrical Division -02, Vikas Minar
Replacement of outdated/damaged expansion Bellow, butterfly valve, balancing valve i/c miscellaneous HVAC items for TT building at YSC, DDA.
2026_DDA_906320_1
04/EE(E)/ELD-2/DDA/2026-27
Open Tender
Electrical Works
Percentage
60 days
As per tender documents
Please refer Tender documents.
16 documents required · 16 mandatory
₹0
₹44,232
In the office of EE/ELD-2,Vkas Minar
22 May 2026
23 Apr 2026
6 May 2026
23 Apr 2026
5 May 2026
27 Apr 2026
27 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Supplying and replacement of Balacing Valve ( including dismentaling of valve) in condenser water line as per specifications. BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch & PN 16 pressure rating for condenser water circulation as specified Including dismantaling with Cutting of pipes and flange for existing balancing valve. for chiller Unit | - | - | - | - |
| - | 250 MM Dia | 3 | Nos | 1,59,242 | ₹4,77,726 |
| - | 200 MM Dia With Insulation As per Specification at Site | 3 | Nos | 73,307 | ₹2,19,921 |
| - | Supplying and replacement of Butterfly Valve in chilled water line as per specifications at site with C I body flanged construction with EPDM coated disc with long pitch & PN 16 pressure rating for condenser water circulation as specified Including dismantaling with Cutting of pipes and flange for existing valve for chiller and pumps | - | - | - | - |
| - | 80 MM Dia ( For Makeup Tank) | 2 | Nos | 5,419 | ₹10,838 |
| - | 200 MM Dia with Gear Box ( For Chilled Water Line) with insulation | 10 | Nos | 16,887 | ₹1,68,870 |
| - | 250 MM Dia with Gear Box ( For Condenser Water Line) | 10 | Nos | 28,141 | ₹2,81,410 |
| - | Supplying and replacement of Rubber Expansion Bellow with control unit PN 16 pressure rating for condenser water line for chiller , etc. complete as required Including dismantaling of existing rubber expansion bellow, as required. | - | - | - | - |
| - | 200 MM Dia | 5 | Nos | 20,960 | ₹1,04,800 |
| - | 250 MM Dia | 5 | Nos | 30,511 | ₹1,52,555 |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.61 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.72 MB
NIT04.pdf
Tender Documents • 7.75 MB
BOQ_952638.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .