Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | Admitted-Finance |
| 3 | Admitted-Finance RZ BH 4 STREET NO 5 MAIN SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | Admitted-Finance |
| 4 | Admitted-Finance WZ 1000 B NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
1 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MR ARJUN PATRO
GE U ELECTRIC SUPPLY DELHI CANTT-10
Provision of external electric supply at Stn Polyclinic Shankar Vihar in the area of AGE U Elect Supply No III under GE U Elect Supply Delhi Cantt 10
2020_MES_365701_2
GE ELECT/D-75/2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE U ELECTRIC SUPPLY DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹30,000
Yes
5 Oct 2020
23 Sept 2020
3 Oct 2020
24 Sept 2020
1 Oct 2020
26 Sept 2020
60 days
Amount
Supply & laying or fixing or passing through pipe under ground XLPE cable, insulated screened PVC bedded, galvanised strip or wire armoured, electric power cables (heavy duty) 120 Sqmm 3 core 11 KV grade (earthed) with starnded aluminium conductor.
Supply and fix cable end jointing kit for 11 KV grade cable for outdoor terminal heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, AI conductor cable of size 120 TO 185 sqmm outdoor type all as specified.
M&L for cutting, removing the existing damaged joint and S&F straight through joint heat shrinkable type suitable for HT UG cable XLPE insulalted 3 core x 120 sqmm 11000V grade including preparation complete all as directed (Make: REPL/ Denson). Note:- (a) Excavation, earth work, sand cushioning, brick protection, protection pipe shall be measured and paid saperately.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, laying of pipe etc and not exceeding 10 sqm on plan for manhole etc and getting out in soft/loose soil, complete all as specified and directed.
Returning , filling in , with approved excavated soil including spreading levelling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated material (soils) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class class HV, Type 1, flat, size 300mmx l80mm x 40mm
Dry sand cushioning to under ground electric cable on layer of 08 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of M.E.S Schedule Part-I
Supply and laying galvanised iron pipe 80 mm bore light grade fixed to poles with steel clamps laid under road crossing, fixed to wall etc complete all as specified (Note clamps shall be measure and paid separately) Make - Jindal/TATA/Prakash
M&L for plate Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level,connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion.
M & L for GI earth strip of size 32 x 6 mm laying in trench, fix to pole with necessary clamp and nut, bolt etc including taking out of unsv earth wire.
Boring of holes unhder road, pavement, hardstanding by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure
Cutting of road /Hard standing to a size of 30 cm in width and not exceeding 90cm in depth for laying of protection pipe /cable including spreading, leveling, watering and well ramming in layers and providing PCC in 1:2:4 type B1 using 20mm graded stone aggregate, for the top 100mm layer, complete all as specified and directed.
Supply & install ,testing and commissioning of transformer step down, outdoor type copper wound 11KV/433 Volts (at no load) AC 3 phase 50 Hz 250 KVA capacity, core type, oil immersed naturally air cooled, oil natural air natural (ON/AN) , with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYn-11 with neutral brought out on secondry side (LV) and having taping at +5% to 10% in steps of 2.5% on HV side to be changed by means of hand operated off load tap changergear. The maximum temperature rise should not exceed 40 degree celsius in oil and 45 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celsius transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeability prime grade crgo with M4 grade or better, perfectly insulated and clamped to minimize noise and vibrations. The transformer shall be IS/IEC 60076and as per IS-1180 part - I of 2014 marked and shall comprise of the following :-
(a) One cable box on HT side (Primary side) consisting of three nos porcelain bushing with copper rods, complete with nuts and washer , with cable glands suitable for reception/taking out 3 core 120 Sqmm, HT 11000 volts grade, XLPE insulated and PVC sheathed, heavy duty , armoured cables including jointing materials complete.
(b) One cable box on LT side(secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception/taking out 3.5 core 120 sqmm, LT 1100 volts grade, PVC/XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete. (c ) conservator with filter type drain valve and oil level guage. (d) De-hydrating breather with first fill of dehydrating agent (Silica Gel). (e) Explosive vent, Thermometer pocket on tank cover, oil level guage, Oil drain filter valve, Lifting ligs,oil filling hole with cap/plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers. (f) One 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device. (g) Two earthing terminals on tank cover to facilitate fixing of 50x6mm galvanised iron earth strip for earthing of body. (h) Rating plate and terminal marking plate.
(j) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral. (k) First fill of new and unused transformer oil, IS-335 of 1986 marked, filtered and tested upto 50 KV dielectric strength at 2.5 mm air gap between testing electrodes, specific resistance at 27 Degree celsius Ohm-om 500 x 10 the power12, water content 50 PPM, Dielectric dissipation factor (tan Deta at 90 degree celsius) 0.005, Neutralisation value mg of KOH/gm of oil 0.03, Inter facial tension N/M at 27 Degree celsius - 0.04, flash point 140 Degree celsius and sluge 0.1 % by weight. (l) Providing adequate size and nos of channels, embeded in floor, for movement of transformer. (m) Tranformer losses shall not exceed the loses mentioned in Table 6 of IS: 1180 of 2014 Part - I with energy Effeciency level - II.
Supply and installation , testing and commissioning of 11 KV, 630 Amps, 21 KA/3 sec outdoor type Ring main unit IP 54 protection plug in type extensible on one side SF 6 gas insulated one incoming and two outgoing (3 way ) with metering plate form mounted compact switch gear consisting of 02 Nos load break switch as incommer and 01 Nos outgoing VCBs , all live parts, bus bars VCB will be enclosed in robotically/manual welded minimum 2 mm thick stainless steel tank filled with SF 6 gas IP 67 Degree of protection and tested for internal arc 20 KA/1 sec as per latest IEC 62271-200 complete installed at basement of building, including the cost of PCC foundation for placing of RMU on plinth complete all as specified and directed. The unit shall include the following with all necessary standard fitting required at site: - (Make : ABB / SIEMENS / SCHNEIDER C&S).
(A) Incoming Load Break Module - 02 Nos each switching unit shall be designed as a three position switch. This three function switch combines the functions of switch disconnector and earthing switch cables switch 12 KV, 630 Amp, 21 KA - 01 Set. Snap action mechanism for motorised and manual(Both) operation with integrated earthing switch switch - 01 Nos. Cable bushing 630 Amp standard C bushing - 01. Fault passage indicator, On(N-1) load break switch where n= no of load break switch >>s/c & E/F FPI with digital display to be added for detection of cable fault. ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01. Capacitive voltage indication fixed type LED display - 01. ON, OFF, TRIP mechanical indication on the front mimic of the panel - 01. Cable box for termination of cable up to 1 No. x 185 sq.mm - 01. Cable cover standard - 01. Set of 12kV Cable Termination Boots - 01. Cable entry bottom, front - 01
(B) (i) Out going VCBs - 01 No consisting of following - function unit consist of vaccum circuit breaker in combination with a three position switch. The three position switch fulfills the operation of the disconnector function and earthing function circuits breaker unit is equipped with an over current transformer for the protection of distribution Transformer/circuit vaccum circuit breaker 12 KV, 630 A, 21 KA - 01. Spring assisted closing with stored Energy triping mechanism for motorised operation with integrated earthing switch - 01. live cable LED indicators thru capacitor voltage dividers mounted on the bushings push button for breaker trip - 01 sec O/C + E/F self powered numerical protection relay with low and High set for Over current and earth fault Relay should have facility to display the maximum loaded phase current also current also relay shall record minimum 5 fault records with time stamping - 01 Alaram trip indication 6 window anuciator for transformer faults Mechanical ON/OFF/EARTH indication -01. Auxliary contacts on load switch are 1 No+2NC & Auxiliary conract on earth switch is 1 No+ 1NC-01. Self powered electronic numerical protection relay providing 3 over-currents & 1 E/F protection - 01, shunt trip coil 24 V DC-01 capactive voltage indication fixed type LED display -01 ON/OFF/Trip mechanical indication on the front mimic of panel-01 cable box for termination boots-01. Metering Equipment incl. 01 x Digital Voltmeter (Acc.Cl.0.5), 01 x Digital Ammeter (Acc.Cl.0.5), 01 x Tri-VectorMeter (Acc.Cl.0.5) Auxliary relay for transformer protection -06 Nos.
(B) (ii) Out going VCBs - 01 No, One consisting of CT 10/1 -5p10.2.5VA- 03 and other one consisting of CT 50/1 -5p10.2.5VA- 03.
(C ) Additional equipment deliverd separately or mounted seperatly, Bus connected with battery charger and battries for motor power supply-01 (i) PT ratio 11KV/3/110/v3, 100 va, 0.5 class for measurement with volts meter(ii) Auxliary transformer of 11KV/230V, 1 KVA for powering the motors and battery charger (iii ) 24 V DC battery charger and battries for motor power supply. Standard mano meter -01, Operating handle - 02 , cable clamping provision(standard)-01 Operation and maintance manual - o1, installation and commissioning manual - 01, cost of PCC works for placing RMU on plinth is deemed to be included in the cost, Height of plinth shouldnot be less than 0.45 mtrs from ground level.
NOTE :- (a)The above module consisting of one Load break Switch and 02 VCBs shall be alligned appropriately and must have electrical and mechanical interlocking as per latest electrical safety norms including foundation complete.
Material and labour for brick masonry platform (suitable for 250 KVA transformer) as shown on sketch P-1 (attached) having size 1.6m X 1.6m and total height 1.6 M(0.45 M below ground level including excavation and earth work ,1.15M above ground level including RCC slab 150 mm on top) and cement plaster on all side with 1:4 cement morter complete all as specified and directed by Engr-in- charge.
M&L for PCC in foundation filling and mass concrete type D2 (1:4:8) using 40 mm grded aggregate for foundation of pole complete all as specified
M& L for PCC type B1 (1:2:4) using 20 mm graded stone aggregate for pedestal of poles including use and waste of formwork complete all as specified
M&L for brick work with Sub Class 'B bricks straight OR curved on plan exc 6 M mean radius built in cement morter 1:6 complete all as specified and directed.
M &L for plaster hacking for keyscrubbing down with water etc and rendering 10 mm thick in cement plaster 1 : 4 frinishing in the surfaces fair and even, complete all as specified and directed.
S&F of angle/Flat iron of any size for fencing to sub station/RMU fixed as vertical/horizental member for frame to wire mesh including cutting to shape, drilled and countersunk for screw including welding and grouted in ground with PCC type B1 (1:2:4) using 20 mm graded aggregate for pedesta of angle at site and hinged for gate complete , confirming to Fe290.Gde-E-165 complete all as specified and directed
NOTE :- The cost of Excavation and earth work , Brick work and PCC for item No 23 above shall be paid seperatly.
S&F 4 to 5 mm thick mild steel wire 80x40 mm mesh up into mattressess or cages, lapped wired and fixed in position including welded for fencing to grid all as specified and directed.
supply and fix Pipe galvanized light graded supplied and laid complete including fittings 50 mm dia.
M&L for danger notice board of 1.6 mm thick mild steel,vitreous enamelled white with letters,figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts and nuts of approved size for HT 25 x 20 CM size complete.
Supply, Install, test and commissioning of factory made tested LT Panel board Out door LT Panel/LT Pillar Box comprising of the following :-
Fabrication Details : Main frame 2 mm thick CRCA sheet, partition sheets / covers / doors of 2 mm thick CRCA sheet, gland plates 2 mm thick MS sheet (undrilled), base frame of 75 mm MS channel with provision of incoming and outgoing cable entry at the bottom for outdoor installation, free standing floor mounted with degree of protection IP 54 and locking arrangements Bus bar details : Material shall be alluminum bus bar, sleeving heat shrinkable type, with bus bar sizes for phase 25x10mmx2 AL. Flat, neutral 25x10mm Al flat and bus bar support of epoxy type, earthing of 40x6 mm GI Flat.
Painting Details : Pillar box shall be painted with 7 tank process powder coated.
Wiring : Pannel wiring shall be of 2.5 sq mm copper standard with 5A MCB wiring for controll wiring and indication lamps
Accessories for Pillar Box : 0-500V Digital Multi functional meter cat no. WM30KFC3C00 of L&T - 01 No for incoming CKT and 0-630 A Digital KWH meter - 01 No cat No. WM30JFC3C00 of L&T ,(Flush type) and Indication Lamps (LED) - 03 No. make: L&T /Binay /Elmeasure (a)Incommer:- 400 Amp, 50 KA, 4 Pole MCCB and on load change over switch Frame 3 open execution 400A 4 pole complete with operating hande and acessories complete all as specified and dierected. Make: L&T/or equivalent in Schnider
Supply and laying or fixing or passing through pipe XLPE insulated 1100 volts grade underground cable with aluminum conductor armoured with steel strip or wire cross sectional area 185 sqmm 3.5 core.
Supply & laying Sub Class 'B' Bricks having minimum compressive strength 75 Kg laid in trenches for cable protection.
Supply and lay 300 Sqmm 3 1/2 core cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked as per IS 7098-I laid in trenches ducts or fixing or passing through GI pipe across the road/path/drains/along wall/floor/equipment etc including taking out old unserviceable cable complete all as specified and as directed. Note:- (a) Excavation, earth work, sand cushioning, brick protection, protection pipe shall be measured and paid saperately.
All as per item No 30 above but of size 3.5 core 150 sqmm
All as per item No 30 above but of size 3.5 core 70 sqmm
All as per item No 30 above but of size 3.5 core 50 sqmm
Supply and laying in replacement galvanised iron pipe 80 mm bore light grade fixed to poles with steel clamps laid under road crossing, fixed to wall etc complete all as specified (Note clamps shall be measure and paid separately) Make - Jindal/TATA/Prakash
Supply , fixing and commissioning of LT Panel Out door LT Panel / LT Pillar Box of comprising of the following all as directed by removing the old existing panel
Fabrication Details : Main frame 3 mm thick CRCA sheet, partition sheets / covers / doors of 2 mm thick CRCA sheet, gland plates 2 mm thick MS sheet (undrilled), base frame of 75 mm MS channel with provision of incoming and outgoing cable entry at the bottom for installation, seperate chambers for Main Bus Bars, MCCBs /ACB and Cable end connections free standing floor mounted with degree of protection IP 54 and with heavy duty Hinges for doors and locking arrangements with Aldrops at front and Back Bus bar details : Material shall be alluminum bus bar, sleeving heat shrinkable type, with bus bar sizes for phase 1.5 times the Rating of incommer MCCB /ACB and out going shall be of rated capacity and bus bar shall be support of epoxy type insulators , earthing of 40x6 mm GI Flat.
Painting Detais : Painting shall be 7 tank processed powder coated shall be a dry finishing process that uses finely ground particles of pigment and resin based polymer that are electrostatically charged and sprayed onto electrically grounded parts
Wiring : Pannel wiring shall be of 2.5 sq mm copper standard with 5A MCB wiring for controll wiring and indication lamps
Accessories for Pillar Box : Digital Multifunctional Meters CT/PT programmable with RS 485 communicatio port CL 0.5 with direct acess to basic power and Energy parameters and Indication Lamps (LED) - 03 No. make: L&T cat no WL440531OOOO or equivalent in Secure /Elmeasure
Switch Gears: (a) Incommer:- 200-250A Thermal realese DN 250 4 pole,36 KA MCCB-1No along with sprader terminals Make: L&T/or equivalent in Schnider/Simens
(b) Outgoing:-(i)160-200A,DN 250 3 pole,25 KA,MCCB along with sprader terminals along with sprader terminals-2 no,s Make: L&T/or equivalent in Schnider/Simens (ii) 63-80A,3 pole DN 100D, 25 KA,MCCB along with sprader terminals along with sprader terminals-4 no,s Make:L&T / or equivalent in Schnider
Note : Rate quoted includes for necessary PCC foundation of LT pannel and includes the cost of all Accessories and switch gears
Supply , fixing and commissioning of LT Panel Out door LT Panel / LT Pillar Box of comprising of the following all as directed by removing the old existing panel
Fabrication Details : Main frame 3 mm thick CRCA sheet, partition sheets / covers / doors of 2 mm thick CRCA sheet, gland plates 2 mm thick MS sheet (undrilled), base frame of 75 mm MS channel with provision of incoming and outgoing cable entry at the bottom for installation, seperate chambers for Main Bus Bars, MCCBs /ACB and Cable end connections free standing floor mounted with degree of protection IP 54 and with heavy duty Hinges for doors and locking arrangements with Aldrops at front and Back Bus bar details : Material shall be alluminum bus bar, sleeving heat shrinkable type, with bus bar sizes for phase 1.5 times the Rating of incommer MCCB /ACB and out going shall be of rated capacity and bus bar shall be support of epoxy type insulators , earthing of 40x6 mm GI Flat.
Painting Detais : Painting shall be 7 tank processed powder coated shall be a dry finishing process that uses finely ground particles of pigment and resin based polymer that are electrostatically charged and sprayed onto electrically grounded parts
Wiring : Pannel wiring shall be of 2.5 sq mm copper standard with 5A MCB wiring for controll wiring and indication lamps
Accessories for Pillar Box : Digital Multifunctional Meters CT/PT programmable with RS 485 communicatio port CL 0.5 with direct acess to basic power and Energy parameters and Indication Lamps (LED) - 03 No. make: L&T cat no WL440531OOOO or equivalent in Secure /Elmeasure
Switch Gears: (a)Incommer:- 320-400A DN 3400N 50KA,MCCB 4 pole along with sprader terminals along with sprader terminals-1no,s Make: L&T/or equivalent in Schnider
(b)Outgoing:-(i)160-200A,DN2 250 3 pole,36KA,MCCB along with sprader terminals along with sprader terminals-1 no,s Make: L&T/or equivalent in Schnider (ii)63-80A,3 pole DN0 ,25 KA,MCCB along with sprader terminals along with sprader terminals-3 no,s Make: L&T/or equivalent in Schnider
Note : Rate quoted includes for necessary PCC foundation of LT pannel and includes the cost of all Accessories and switch gears
Supply , fixing and commissioning of LT Panel Out door LT Panel / LT Pillar Box of comprising of the following all as directed by removing the old existing panel
Fabrication Details : Main frame 3 mm thick CRCA sheet, partition sheets / covers / doors of 2 mm thick CRCA sheet, gland plates 2 mm thick MS sheet (undrilled), base frame of 75 mm MS channel with provision of incoming and outgoing cable entry at the bottom for installation, seperate chambers for Main Bus Bars, MCCBs /ACB and Cable end connections free standing floor mounted with degree of protection IP 54 and with heavy duty Hinges for doors and locking arrangements with Aldrops at front and Back
Bus bar details : Material shall be alluminum bus bar, sleeving heat shrinkable type, with bus bar sizes for phase 1.5 times the Rating of incommer MCCB /ACB and out going shall be of rated capacity and bus bar shall be support of epoxy type insulators , earthing of 40x6 mm GI Flat.
Painting Detais : Painting shall be 7 tank processed powder coated shall be a dry finishing process that uses finely ground particles of pigment and resin based polymer that are electrostatically charged and sprayed onto electrically grounded parts
Wiring : Pannel wiring shall be of 2.5 sq mm copper standard with 5A MCB wiring for controll wiring and indication lamps
Accessories for Pillar Box : Digital Multifunctional Meters CT/PT programmable with RS 485 communicatio port CL 0.5 with direct acess to basic power and Energy parameters and Indication Lamps (LED) - 03 No. make: L&T cat no WL440531OOOO or equivalent in Secure /Elmeasure
Switch Gears: (a) Incommer:-Manual Drawn Out Type ACB 4 pole 800A with SR18G relaease for tripping system Make : L&T Cat No SL96062
(b) Outgoing:-(i) 320-400A DN 3400N 50KA,MCCB 4 pole along with sprader terminals along with sprader terminals-2no,s Make: Cat No.CM98404OORO of L&T/or equivalent in Schnider (ii) 200-250A Thermal realese DN 250 4 pole,36 KA MCCB-3 No along with sprader terminals-3 nos Make: Cat No.CM90642OOPO of L&T/or equivalent in Schnider/Simens
Note : Rate quoted includes for necessary PCC foundation of LT pannel and includes the cost of all Accessories and switch gears
Supply , fixing and commissioning of LT Panel Out door LT Panel / LT Pillar Box of comprising of the following all as directed
Fabrication Details : Main frame 3 mm thick CRCA sheet, partition sheets / covers / doors of 2 mm thick CRCA sheet, gland plates 2 mm thick MS sheet (undrilled), base frame of 75 mm MS channel with provision of incoming and outgoing cable entry at the bottom for installation, seperate chambers for Main Bus Bars, switch Gears and Cable end connections free standing floor mounted with degree of protection IP 54 and with heavy duty Hinges for doors and locking arrangements with Aldrops at front and Back
Bus bar details : Material shall be alluminum bus bar, sleeving heat shrinkable type, with bus bar sizes for phase of rated capacity and bus bar shall extended type be support of epoxy type insulators for connection 300SQM Lt cable Per circuit along with , earthing of 40x6 mm GI Flat.
Painting Detais : Painting shall be 7 tank processed powder coated shall be a dry finishing process that uses finely ground particles of pigment and resin based polymer that are electrostatically charged and sprayed onto electrically grounded parts
Wiring : Pannel wiring shall be of 2.5 sq mm copper standard with 5A MCB wiring for controll wiring and indication lamps
Accessories for Pillar Box : Digital Multifunctional Meters CT/PT programmable with RS 485 communicatio port CL 0.5 with direct acess to basic power and Energy parameters and Indication Lamps (LED) - 03 No. make: L&T cat no WL440531OOOO or equivalent in Secure /Elmeasure
Switch Gears: (a) Incommer / Ougoing :-on load change over switch Frame 3 open execution 315 A 4 pole complete with operating hande and acessories complete Make : L&T / Schnider /Simens (b)320A 3400N 50KA,MCCB 4 pole along with sprader terminals along with sprader terminals-2no,s Make: Cat No.CM98404OORO of L&T/or equivalent in Schnider
Note : Rate quoted includes for necessary PCC foundation of LT pannel and includes the cost of all Accessories and switch gears
Earthing complete with GI strip of size 25 x 4 mm thick earth plate electrode 600 x 600 x 6mm thick, buried directly into ground vertically not less than 2.25 Mtr below the ground level with top edge of the earth plate to a depth not less than 1.5 Mtr below the ground level, connected to a copper wire 4mm dia including GI protection pipe 15mm bore light grade connected from electrode up to test point including necessary earth work, PCC/RCC chamber cover 50mm thick in RCC 1:2:4 type B1 with 8mm TMT bars 15 cm c/c both ways, funnel arrangement etc as per electrical plate No 5 of SSR part I Note : Rate shall be deemed to be inclusive of necessary excavation and earth work in any type of soil, removal of surplus soil to a distance not exceeding 50m, RCC cover slab and PCC chamber etc.
Cutting of road /Hard standing to a size of 30 cm in width and not exceeding 90cm in depth for laying of protection pipe /cable including spreading, leveling, watering and well ramming in layers and providing PCC in 1:2:4 type B1 using 20mm graded stone aggregate, for the top 100mm layer, complete all as specified and directed.
M/s ELECTROSHINE ENGINEERS
MV Engineers And Contractors
Rajindera Enterprises
Vijay Electricals
mayur enterprises
M/s Adhikari construction co.
ALLIED CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .