Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.5 Cr+₹3.6 L (2.46%)Rejected-Finance | ₹1.5 Cr+₹3.6 L (2.46%) | L2 | Rejected-Finance SINCE NOT L1 |
| 3 | L3₹1.7 Cr+₹19.9 L (13.6%)Rejected-Finance | ₹1.7 Cr+₹19.9 L (13.6%) | L3 | Rejected-Finance SINCE NOT L1 |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
13 Nov 2023, 6:00 pmClosed
CWE AMRITSAR CANTT
HQ CWE AMRITSAR OLD CANTT
PROVN OF BLDGS FOR MIL DENTAL CENTRE TYPE C AT OLD GE AMRITSAR
2023_MES_614585_2
CWE/ASR-31/2023-24
Open Tender
Civil Works
Lump-sum
270 days
GE AMRITSAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE AMRITSAR
₹2.0 L
Yes
21 Dec 2023
17 Oct 2023
15 Nov 2023
17 Oct 2023
13 Nov 2023
1 Nov 2023
Amount
LUMPSUM/PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
Schedule 'A' Part-I BUILDING WORKS :- Lump sum price worked out by the contractor for building of MDC Type 'C' complete all as specified and shown on drgs as listed in Sch A Part I brought forward from Srl Page No 24.
SCHEDULE ‘A’ PART-II "SITE CLEARANCE, EXCAVATON AND EARTH WORK" :- Lump sum price worked out by the contractor for site clearance, excavation and earth work complete all as specified and shown on drgs as listed in Sch A Part I brought forward from Srl Page No 25.
Schedule 'A' Part-III “PARKING SHEDS” :- Lump sum price worked out by the contractor for “PARKING SHEDS” as listed in Schedule 'A' Part-III brought forward from serial page No. 27 complete all as specified and shown on drgs.
Schedule 'A' Part-IV “FIRE FIGHTING” :- Lump sum price worked out by the contractor for “FIRE FIGHTING” as listed in Schedule 'A' Part-IV brought forward from serial page No. 29 complete all as specified and shown on drgs.
Schedule 'A' Part-V “SEWAGE DISPOSAL” :- Lump sum price worked out by the contractor for “SEWAGE DISPOSAL” as listed in Schedule 'A' Part-V brought forward from serial page No. 31 complete all as specified and shown on drgs.
Schedule 'A' Part-VI “AREA DRAINAGE” :- Lump sum price worked out by the contractor for “AREA DRAINAGE” as listed in Schedule 'A' Part-VI brought forward from serial page No. 32 complete all as specified and shown on drgs.
Schedule 'A' Part-VII “CHAIN LINK FENCING” :- Lump sum price worked out by the contractor for “CHAIN LINK FENCING” as listed in Schedule 'A' Part-VII brought forward from serial page No. 35 complete all as specified and shown on drgs.
Schedule 'A' Part-VIII “EXTERNAL WATER SUPPLY” :- Lump sum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule 'A' Part-VIII brought forward from serial page No. 36 complete all as specified and shown on drgs.
Schedule 'A' Part-IX “EXTERNAL ELECTRIC SUPPLY” :- Lump sum price worked out by the contractor for “EXTERNAL ELECTRIC SUPPLY” as listed in Schedule 'A' Part-IX brought forward from serial page No. 38 complete all as specified and shown on drgs.
Schedule 'A' Part-X “PVC CONDUIT” :- Lump sum price worked out by the contractor for “PVC CONDUIT” as listed in Schedule 'A' Part-X brought forward from serial page No. 39 complete all as specified and shown on drgs.
Schedule 'A' Part-XI “EARTHING EQUIPMENT” :- Lump sum price worked out by the contractor for “EARTHING EQUIPMENT” as listed in Schedule 'A' Part-XI brought forward from serial page No. 41 complete all as specified and shown on drgs.
Schedule 'A' Part-XII “DG SETS” :- Lump sum price worked out by the contractor for “DG SETS”as listed in Schedule 'A' Part-XII brought forward from serial page No. 43 complete all as specified and shown on drgs.
Schedule 'A' Part-XIII “SOLAR WATER HEATER” :- Lump sum price worked out by the contractor for “SOLAR WATER HEATER” as listed in Schedule 'A' Part-XIII brought forward from serial page No. 45 complete all as specified and shown on drgs.
Schedule 'A' Part-XIV “COOLING APPLIANCES” :- Lump sum price worked out by the contractor for “COOLING APPLIANCES” as listed in Schedule 'A' Part-XIV brought forward from serial page No. 46 complete all as specified and shown on drgs.
Schedule 'A' Part-XV “INTERNAL ELECTRIFICATION” :- Lump sum price worked out by the contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule 'A' Part-XV brought forward from serial page No. 52 complete all as specified and shown on drgs.
Schedule 'A' Part-XVI “INTERNAL WATER SUPPLY” :- Lump sum price worked out by the contractor for “INTERNAL WATER SUPPLY” as listed in Schedule 'A' Part-XVI brought forward from serial page No. 53 complete all as specified and shown on drgs.
Schedule 'A' Part XVII (Miscellaneous items)
S&F for 15 mm Bib taps,with sensor system cast copper alloy fancy type chromium plated with flange screwed down screwed for iron pipe of 15mm bore.Make- Jaquar or equivalent approved by GE.(Cat part No. SNR-CHR-35019PM for reference) complete all as specified and directed.
Supplying laying in trenches jointing and testing DWCPE pipes(SN8) 200 OD/175 OD mm marked all as specified and directed.(Excavation and earthwork shall be measured and paid seprately under appropriate Item of Sch A)
S&F for PVC coated galvanized iron chain link fencing, made of GI wire dia not less than 3 mm, and minimum dia 4.5 mm after PVC coating, having any mesh size (mesh size as approved by GE) including line wire, any type of standards, rails, straining bolts, etc including provission of binding wire, fixed as knuckled type complete all as specified and directed by the Engineer-in-Charge.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil, separate the roots/grass and good earth by sieving with suitable sieve size , stacking of good earth & mixed with suitable manure of ratio 5:1 including supply of manure, screened through sieve of 1.5 designation 4.75 mm and spreading the mixture of good earth & manure , applying suitable pesticides , watering to a depth of 15cms, including removal of roots/grass out of site complete all as specified and directed by the Garrison Engineer
Material and Labour for developing Lawn by laying and dibbling of grass Stealers of 'DOOB GRASS' planting , roofing etc complete as approved and as directed by the Garrison engineer.
Supply & labour for developing and Planting of Bottle palm tree of height not less 4 feet including exavation in post holes of size 60 cm X 60 cm X 60 cm or according to the plant size and plant the trees straight inside the pit and fill up the pit with the earth along with inorganic fertilise manure (compost) in the proportion (3:1) and remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
Supply & labour for developing and Planting of Gulmohar tree (Delonix regia) of height not less 2 feet including exavation in post holes of size 60 cm X 60 cm X 60 cm or according to the plant size and plant the trees straight inside the pit and fill up the pit with the earth along with inorganic fertilise manure (compost) in the proportion (3:1) and remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
Supply & labour for developing and Planting of Amaltas tree (Cassia fistula) of height not less 2 feet including exavation in post holes of size 60 cm X 60 cm X 60 cm or according to the plant size and plant the trees straight inside the pit and fill up the pit with the earth along with inorganic fertilise manure (compost) in the proportion (3:1) and remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
Supply & labour for developing and Planting of Neem tree ( Azadirachta Indica) of height not less 3 feet including exavation in post holes of size 90 cm X 90 cm X 90 cm or according to the plant size and plant the trees straight inside the pit and fill up the pit with the earth along with inorganic fertilise manure (compost) in the proportion (3:1) and remove and spread the surplus excavated soil complete all as specified and as directed by the Engineer in Charge.
Material & labour for developing and Planting "HEDGES" including 60cm wide laying and dibbling of Soil rows and watering , including excavation post holes for plant as required , returning filling with earth in necessary watering and finally fine dressing, levelling etc and complete including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling , the distance between plants not exceeding 90cms complete all as specified and as directed by the Engineer in Charge. The following species for Hedges shall be used:- (a) Ixora (b) Hibiscus (c) Goudi-Choudi (d) Plumbago (e) Nerium Oleander (f) Tecoma Capsensis Eranthemum Note for Srl item No 2.04 to 2.10 (a) The cost of earth, royality, manure & item transportation is deemed to be inlcuded in the unit rate quoted. (b) After the certified date of completion of work, contractor shall engage 01 Mali for the 06 months for the purpose of watering, cutting / trimming grasses, leaves etc, maintenance & complete upkeep of gardens. The T&P / machine for grass cutting, blades, scissor for upkeeping of garden after completion shall be provided by contractor. The rates quoted shall be deemed to be inclusive of all & nothing extra shall be admissible.
M&L for drilling and tapping CI/DI water mains of 100/150 mm dia (in position) for branch connections of the internal dia 40 mm including MS clamp of suitable size for turning water off and on and draining and refilling complete all as directed and specified by Engineer-in-Charge.
Material and labour for construction of brick masonary pits (230mm thick wall) of 900x600x1000mm internal dimension (bottom PCC floor of the pit should be minimum 30cms below the bottom surface of sluice valve flange to provide sufficient working space), bottom floor of the pit be constructed in PCC (1:4:8) type D2 using 15cms thick with 20mm stone aggregate for foundation, brick wall with sub class 'B' bricks built in CM 1:6, inner and exposed surfaces and bottom floor of the pit should be plastered in cement mortar (1:4) 15mm thick, PCC 1:2:4 type B1 using 20mm graded stone aggregate for coping. The sluice valve and other fittings should be housed in center of the pit. The vertices of the pit should in right angle and chamfered. The top cover of the pit will be made out of MS sheet 3mm thick with angle iron frame made out of MS angle 50mmx50mmx6mm with galvanized steel hinges two Nos. and locking arrangements duly painted with two coats of water resistant synthetic enameled paint over one coat of red oxide including necessary excavation and earth work in any type of soil complete all as shown in Drg No. CEJZ/TD-1060 Sheet 1/3 to 3/3.
Shifting of transformer 200/250 KVA from Extg location to MDC (within 2500 Mtrs) outdoor type 11000/433 volts, 3 phase 4 wire, 50 cycle naturally oil cooled type suitable for outdoor installation on plinth of MDC sub stn complete all as specified and directed by Engr-in-Charge. NOTE: (a) Rate shall be inclusive of transformer plinth of size 1.5x1.5x1.5 mtr (b) The safe transformer lifting from extg location, shifting and placing on new plinth is contractors responsibilty and any damage to transformer in these activities will be entire contractors responsibilty and contract has to make good the losses. (c) The transformer oil will be filtered by the contractor and topping of the same will be done by the contractor before energysing the transformer, rate quoted shall be inclusive of the same. (d) The existing transformer of capacity 160 KVA will be removed from pole and will be deposited to Thimayya Power House.
Supply and fixing double compression copper gland for fixing armoured cables of size 95 sqmm 3 core nominal cross sectional area complete all as directed
All as per ser item No. 2.14 above but cross sectional area 120 sqmm 3½ core complete all as specified and directed.
All as per ser item No. 2.14 above but cross sectional area 70 sqmm 3½ core complete all as specified and directed.
Supply & laying double wall corrugated (DWC) high density poly ethylene (HDPE) of size 100mm dia including all necessary fittings, PN-4 rating, pressure 6 Kgf/cm², conforming to IS-16205 (Part-24) with high ring stiffness & cursh resistance capacity, etc., laid in trench for protection of cable complete all as directed.
Supply, install, testing and commissioning of LT feeder pillar distribution panel board (KIOSK) CPRI approved, outdoor type, double door (front & rear openable with gasket arround doors), weather/vermin proof of IP-54, made out of 3.15mm thick CRCA mild steel (certificate from manufacturer will be necessary for quality aasurance and guarantee) as per IS/IEC-61439 of suitable size and medium channel 75mm base mounting frame of 50mm x 50mm x 5mm, with stainless steel hinges, door handles (front & rear), factory assembled cubicle pattern modular and compartmentalized construction, floor mounted free standing type, 3 phase and neutral 500 amps current carrying capacity aluminium busbar with epoxy insulated coating with colour sleeves and including incoming ACB and outgoing MCCBs, cable galleries inter connecting busbar connection/linkage with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry complete with the following accessories and suitable for housing one incoming MCCB and outgoing MCCBs of capacity as below complete and mounting the panel board on suitable foundation with PCC (1:3:6), bedding upto a height 45cm above ground level, duly grouted with bolts, nuts & washers by using angle iron frame of size 50mm x 50mm x 6mm including prewired with suitable size PVC insulated copper conductor cable not less than 2.5 sqmm complete all as specified and directed with the following accessories:-
Supply and fixing FRP fencing made up with using FRP rod 12 mm dia, channel size 50 x 24 x 4mm box section 50 x 25mm "I" section 38 x 15 x 3 mm and square box section 50 x 50mm in post embedded in plain cement concrete (1:4:8) type D2 using 20 mm graded stone aggregate (45cm x 45cm x 45cm) including necessary excavation and earth work at 1.25m C/C with height of fencing 2m (the panel shall be of size 2 mtr in height and 1 mtr in width) from ground level including entrance gate of size 1m x 2m of same material, Stainless steel aldrop bolt 300mm long, 150mm size pressed steel handless and 2 Nos, tower bolts stainless steel hinges as required etc, complete all as specified and directed by Engineer-in-charge. Make as approved by GE confirming to above specification. Note : (a) Vertical posts and rail section shall be manufactured of fibre glass re-inforcement min 45% and formulation of polyster based thermostat resins. (b) Rate quoted shall be inclusive of excavation and earth work and PCC all as specified in the item.
Supply and fixing double compression copper gland for fixing armoured cables of size 120 sqmm 3½ core nominal cross sectional area complete all as directed
Supply, install, test and commissioning of Silent Diesel Engine driven with AMF panel with suitably heavy duty contactors Generating set, Water cooled type, BHP 156 @ 1500 RPM, 6 cylinder, Acoustic proof, comprising Diesel Engine as per IS:10001/10002, Alternator as per IS: 13364, AC, 415 Volts, 50 Hz, 3 phase 4 wire, 125 KVA capacity coupled to Engine, complete with foundation (as per OEM design), installed/fixed on common base plate with anti vibration pads/friction pads and comprising:- A) Battery charger of suitable capacity for charging the batteries suitable for operation on AC 1-φ, 230 volts 50 Hz B) Battery of suitable capacity and Nos with copper flexible PVC insulated cables and terminals lugs. C) Initial filing of engine oil to te required level/standard. D) Fuel tank capacity not less 8 working hours fuel with initial filling of diesel of required quantity for testing the DG set E) Control panel with digital type Metre for reading volts, amps, frequency, RPM, hours run, KWH etc., F) Engine safety unit indicator for supply ON, low LOP, battery removed, high tempareture, fuse open, 'V' Belt failed, charge, auxiliary trip/emergency stop, stop solenoid ON etc., G) Pressure gauge 0-10 bar, tempareture gauge, ammeter 50-0-50, indicator lamp for set ON, load ON, start switch, key type ON/OFF control. H) AMF panel with suitable rating heavy duty conductors & controller. NOTE: (a) Electrical load test on Gen set shall be carried out for 12 hrs at site and all arrangement to carry out the load test as per particular specification shall be made by the contractor. (b) Diesel oil for testing of DG set shall be deemed to be included in the rate quoted. (c) Training to department staff shall be given. (d) Accoustic proof enclosure shall conform to latest Central Pollution Control Board (CPCB-IV) norms and shall be carried out by authorised manufacturers and certificate to this effect shall be submitted. (e) Operation and Maintenance manual and test certificate for Engine, Alternator and Acoustic proof enclosure. (f) Rate quoted sall be deemed to have been inclusive of above
Supply, install, testing and commissioning of refrigerator, electric driven, single phase, 230 volts AC,50 Hz, Frost free, Double door, copper coil material, energy efficient BEE 5 (five) star rated of capacity 310 litres as directed by Engr-in-Charge including refrigerator mounting stand complete all as specified and directed
Supply and install voltage stabilizer copper wounded for automatic operation with digital voltmeter to monitor in/out voltage with time delay and bypass switch, single phase, thermal overload protection, low & high voltage cut-off protection, LED indication, IC controlled, naturally air cooled indoor type and design for input variation between 170 volts to 250 volts with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 2 KVA complete all as specified and directed
All as per ser item No. 2.25 above but of capacity 5 KVA
S&F Lamp holder angular type, PVC/Polycarbonate type with back plate suitable for batten fittings including 10cm x 10cm presto plastic board for resting to holder including S&F 01 x 10/12 watts LED lamp, 230 volts complete all as specified and directed
M&L for distribution board, vertical, made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, VTPN 4 way, 415 volts grade with insulated rated bus bar assembly with isolated neutral bar,door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing suitable for fixing MCCB, MCB TPN/TP/SPN/SP etc, complete all as directed
S&F Engagement light LED decorative type including 02 Nos. LED 3 watt bulbs (Red & Green) including connecting up with driver three core flexible copper conductor cases (1.0 mm² size/core) complete all as specified and directed.
S&F Wall mounted fan of 400mm sweep plastic body and blade including pull cords for speed regulation & wide oscillation control, with 1300 RPM, 60 air delivery, 50 Watt, colour as per the direction of Engr-in-Charge complete all as specified and directed
S&F SITC of 25 x 3 mm copper tape conductor with fixing accessories and should be tested for electrical resistivity test, tensile strength, environmental test (salt spray & humidity test) to meet the requirements of IS/IES 62305 and IEC 62561-1&2 complete all as specified and directed.
S&F SITC of copper tape clamp for X-connection and T-connection of 25 x 3 mm aluminium tape conductor with fixing accessories and should be tested for electrical resistivity test, tensile strength, environmental test (salt spray & humidity test) to meet the requirements of IS/IES 62305 and IEC 62561-1&2 complete all as specified and directed.
ESS KAY BUILDER
ANNPOORNA ENGINEERS & BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .