Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.6 LAccepted-AOC N A | NA | NA | 121004 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹37.4 L+₹1.9 L (5.30%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹38.2 L+₹2.7 L (7.51%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹38.3 L+₹2.7 L (7.62%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹38.5 L+₹2.9 L (8.16%)Rejected-Finance FLAT NO A 15 ARCHANA GREEN SOCIETY NIBM ROAD KONDHWA PUNE 411048 | PUNE | MAHARASHTRA | 411048 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹48.8 L
EMD Value
₹97,680
Closing Date
14 Mar 2022, 6:00 pmClosed
GE NORTH PUNE
Garrison Engineer North General Cariappa Marg Camp Pune 411001
GE (N) P/TOKEN- 73 OF 2021-2022PROVISION OF CERTAIN LBW, MW AND SPECIAL REPAIR WORKS IN THE AREA OF AGE B/R (CENTRAL) UNDER GE (NORTH) PUNE
2022_MES_503467_3
GE (N) P/TOKEN- 73 OF 2021-2022
Open Tender
Civil Works
Item Rate
240 days
GE NORTH PUNE
Refer tender documents.
8 documents required · 8 mandatory
₹500
GE NORTH PUNE
₹97,680
Yes
24 Mar 2022
26 Feb 2022
16 Mar 2022
26 Feb 2022
14 Mar 2022
2 Mar 2022
Amount
Excavation in post holes of each n exc 0.5cum and getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface in hard/dense soil etc complete all as specified
M&L for plain cement concrete Type D-2 1:4:8 (using 40mm graded aggregate) in foundation fillings and mass concrete etc complete all as specified.
S&F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc . built up from two or more beam or channel sections or angles with plates, including all lattice bars ,stiiffners , gusset plates conforming to Gde Fe-410W (Gde-E-250) quality etc complete all as specified.
S&F for M.S. Bolts purpose made with hexagonal or square head at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or Square nut n. exc 5cm long and dia of shank exc 11mm but not exc 15mm complete all as specified.
M&L for preparation of new steel surfaces of any description over 10cm girth or width not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primeretc complete all as specified.
Supply and fix 500 litres capacity, HDPE rotational moulded polythelene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in postion including 20mm size brass float valve, high pressure, with polythene float and flynut and connected fittings complete all as specified and as directed.
M&L for machine cut Cuddappa stone slab 20 to 25mm thick fixed with cement and alrdite jointed with neat cement slurry mixed with pigment to match the shade of the slab etc complete all as specified.
M&L for cement concrete 1:3:6 type C2 (using 40mm graded stone agg.) as in plinth protection 75 mm thick finished top surface even and smooth with out using extra cementetc complete all as specified.
S & F Stop valves 20 mm size , cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed etc etc complete all as specified.
S & F Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregates) as in sub base ,mass concrete including demolition of existing PCC etc complete all as specified and directed.
M&L for 25mm thick coloured glossy rubber moulded chequered cement concrete tiles of area exc. 0.08 Sqm and n.exc 0.16sqm each, set, jointed and pointed in net cement slurry mixed with grey cement and pigment in floors over and including 15 mm thick screed bed or bedding layer of cement mortar (1:6) for laying floor finishes etc complete all as specified and as directed.
M&L for autoclave aerated concrete gray rectanguler siporex block of size 150 mm x 230 mm x 650 mm straight or curved on plan exc 6m mean redious built in CM 1:4 etc etc complete all as specified.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surface incl mixing of water proofing compound finished even & smooth with using extra cement etc complete all as specified. (Note: WPC shall be measured & paid seperately)
M&L for rendering 15mm thick in CM 1:6 other than fair faces of brick work finished even & smooth using extra cement complete all as directed.
Supply only integral water proofing compound.
M&L for Marble work green marble 18 to 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with green marble shade complete all as specified.
Chamfering or rounding edges of boards.
Supply and fix aluminium powder coated three track sliding window with two glazed shutters, with 4mm thick float glass ordinary quantity and one shutter of stainless steel wire mesh 0.36 mm dia wire and 1.40mm aperture including good quality of bearing handle, locks, PVC rubber lining etc complete all as specified and as directed. Catlouge numbers of Jindal company or equivalent make as specified. Sections of Jindal company : Three track bottom – 20957, Three track top/vertical – 20958,Handle – 20606, Interlocking – 20605, Top and bottom – 20604).
Supply and fix aluminium powder coated partition using ‘Jindal’ aluminium SP/ DP section or equivalent make as specified with 5mm thick tinted glass, PVC rubber beading,12mm thick prelaminated particle board fixed with glazing clips etc complete all as specified and as directed. Sections : SP (Single partition) - 20033, DP (Double partition) - 20034,Glazing clips - 4407
Supply and fix fully glazed single/ double leaf openable door, using ‘Jindal ' aluminium powder coated sections on door floor spring, pivots, with 5 mm thick glass in panels fixed with aluminium glazing clips section No. 19381 and 19352 and PVC rubber beading all around including with 1” interlock and handle, two lever door lock, sliding wheel complete all as specified and as directed. (Jindal section Nos : Top-19528, Middle – 19575, Bottom – 19530, Vertical – 19526, 1” Interlock (20939), 1” Handle (20602)
Supply and fix in repairs for double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed.
M&L for preparation of surfaces and applying one coat of 100% acrylic exterior emulsion paint to mangalore tiles, roof, parapet wall ,floor etc, on buildings complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new plastered or unplastered wall surfaces of any description over 10cm girth or width not otherwise described and applying two coats of acrylic distemper over a coat of primer all as specified & directed.
Supply and fix in repairs for Garware Sun Control polyster film, 50 micron, reflective type fixed on existing glass panels complete all as specified and as directed.
S & F Anodised Alu. Snap grid 605x605 mm frame wk for false ceiling all as specified.
M&L 9mm thick Acoustical board/tiles for insula-tion and accoustic purposes, 60cm x 60 cm in size, fixed in celing with screws to frame work or with staples on snap grid comlplete as specified.
S & F hangers 6 mm dia G.I. ( up to 1200 mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 X 3 mm size 60 mm long complete all as specied and as directed.
Supply and fix for 0.50mm thick pre-painted galvalume aluminium zinc coating (AZ-150) GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws with side lap complete all as specified and as directed.
All as per item No 29 above above but plain sheet fix in valley gutter / ridge
M&L for Steel work in round or rectangular tube section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates conforming to Fe-410-W (Gde-E-250 quality A) all as specified.
M &L for MS work as in wind tie or any other work incl cutting, drilling holes etc compelete all as specified
M&L for double charged vitrified ceremic tiles 10 mm thick (square/rectangular) polished, area of each tile exc. 0.18 sqm but not exceeding 0.36 sqm, in flooring etc , laid over and including screed bed of 15 mm thick cement mortar (1:4) and jointed in neat cement slurry and pointed in white or coloured cement to match dark shade including dismantling existing tiling, cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and directed.
M&L for double charged Vitrified ceremic tiles 10mm thick of approved shade as in vertical surfaces, skirting etc , set and jointed in neat cement slurry and pointed in white or coloured cement to match dark shade over and including screed bed of 10mm thick in +cement mortar 1:3 including dismantling existing tiling, cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and directed.
M&L for12mm thk toughened glass door of opening size n exceeding 4 sqm with all necessary fittings including brass handle both sides with heavy duty floor spring of make titan ect all necessry fitting to fix the Glass door in position etc as directed.
M&L for mild steel framed work such as grill, gate etc with ends of bars shouldered or rebated or forged into spike framed guard bars barred iron doors, ladders, framed baluster, walk way, railing; frame work, including pintle hinges, stops, hand-made sliding bolts etc,sliding channels for sliding of gate and similar work conforming to Fe 290 Gde-E-165 complete all as specified & as directed.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints fixed to walls, or laid in trenches bore of pipe 110 mm etc etc complete all as specified.
S&F.110 mm dia PVC (SWR) bends, any radius with access door etc etc complete all as specified.
S&F 110 mm dia PVC (SWR) branch piece (Single Y) equal or unequal etc etc complete all as specified.
S&F 110 mm dia PVC (SWR) branch piece double, (Single Y) equal or unequal etc etc complete all as specified.
M & L for reinforced cement concrete (1:2:4) Type- B-0 (12.5 mm graded stone aggregate) as in chajjas, lintel including necessray formwork etc all as directed by Engr-in-Charge.
M & L for Mild steel bars 10mm dia for Fe-410-W (Gde.E-250) quality-A or Fe 290 (Gde E-165) and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc all as directed by Engr-in-Charge
Taking down & removing old water proofing treatment of any description including plaster and cleaning the surfaces of slab with wire brushes, removing dust, foreign materials including flushing at junctions of wall and removing the rubbish off the premises to a distance exc. 500 m & n exc 1.5km all as specified and as directed.
Material and labour for water proofing treatment to RCC roof slab complete all as specified below and as directed by steps of treatment as under:- (a) On the dried plastered surface, one coat of approved bituminous primer @ 0.30 ltr/Sqm of density at 25 degree centigrade 0.87-0.89 kg/litre and viscosity 70-160 cps or cold sticker shall be applied. (b) Over this primered surface one coat of hot blown bitumen of 85/25 shall be applied @1.20 kg/Sqm (c) APP modified bituminous memberance 3mm thick with non woven polyster mat as reinforcement weighing not less than 3.50 Kg/Sqm with plain finish shall be laid over the hot bitumen to make it sandwitched with bitumen on roof surfaces (d) Apply two coats of bituminous aluminium [email protected]/Sqm (e) the overlap of APP shall be done with torch application, a minimum overlap of 150mm shall be made at the end and 100mm shall be made at the longitudinal sides of the polymeric membrance respectively and sealed all ovelaps and joints as per Manufacturers instructions. (Notes: (i) The contractor/Company shall furnish 10 years performance warranty as per manufacturer of material (ii) The work should be done by a company recommended applicator and he should be able to furnish stage wise on site technical reports from the concerned company technologist). iii) The work to be done upto 15m height. the rate quoted should be include of machinery required for handling of materials . Make : STP, FOSROC, Thermax).
Taking down cement plaster on brick/ stone walling including raking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Demolition of cement Concrete any description and in any position from Roof, walls and floors all as directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregates) as in roof padding, finished fair and even complete all as specified and as directed.
Material and labour for 10mm thick rendering in cement mortar (1:3) mixed with integral water proofing compound as per manufacturer's instructions on roof slab finished even and fair complete all as specified and as directed. (Note: waterproofing compound shall be measured and paid separately under relevant item).
M/L for 15mm thick cement plaster in CM 1:6 on brick or concrete surfaces finished even and smooth as specified and directed.
Supply and fix for 30mm thick flush shutters solid core construction, with block board core and plywood face panels, commercial type on both sides including second class hard wood plain cover fillets 35X6mm all around the shutters complete all as specified and as directed
Material and labour for 0.90mm thick decorative laminate type 1 of surface finish, colour, pattern and size as approved, fixed with approved adhesive as per manufacturer’s instructions on horizontal and vertical surfaces etc. complete all as specified and as directed.
M&L for aluminium powder coated louvered ventilator with provision of exhaust fan using ‘Jindal” aluminium section including glass and stainless steel wire mesh etc complete all as specified and directed by Engineer-in-Charge.
S&F Stainless steel butt hinges medium weight 100mm with all as specified and directed. NOTE :- All screws shall be self tapping chrome plated and length of screw not less 38 mm complete all as specified and as directed
Taking down shutters of any description, area exc.2sqm each complete all as specified and as directed.
Taking down chowkhats or frame but with shutters (w/o taking off shutters from frames) n.exc 1.5 Sqm each as in of any size and description and removing from site etc complete all as specified& directed.
Supply and fix for brass mortice lock, vertical type, size 100mm of 4 levers with duplicate key complete all as specified and as directed.
Supply and fix for factory made solid Panel PVC door shutter, 30mm thick (style) consisiting of frame made out of MS tubes for top and bottom rails. M.S. frame shall covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheets for top rail, lock rail, bottom rail; panelling of wood grain printed PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (90°) and joined together with solvent cement, suppling and fixing in the frame at site as per specification and drawing including fittings complete all as specified and as directed. Make: Rajshri/ Sintex/Duraplast/Accucell
S&F in repairs, chromium plated bib cock with wall flange quarter turn complete all as specified and as directed. Cat No. Make Prayag or equivalent make as per Appx 'A' as approved by GE.
S&F in reapir 15mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed.
S&F in repairs brass chromium plated quarter turn two way bib cock with wall flange 15mm dia Cat No. Make Prayag or equivalent as per Appx 'A' as approved by GE complete all as specified and as directed.
Supply and fix in repairs, chromium plated pillar cock 15mm dia quarter turn as per Make Prayag or equivalent of make as per Appx 'A' as approved by GE complete all as specified and as directed.
S&F in repairs chromium plated single towel rail 600mm long including built in side brackets ,Make- Prayag or equivalent of makes as per Appx 'A' as approved by GE complete all as specified and as directed.
S&F in repairs chromium plated toilet paper holder ,Make Prayag or equivalent of makes as per Appx 'A' as approved by GE complete all as specified and as directed.
Supply and fix for vitreous chinaware wash hand basin full Pastel, white, flat back, size 46x46x15Cm, table top type with fixing accessories set, CP brass waste coupling, chain and plug and porcelain stopper, waste fittings, union and waste pipe 32 mm dia of required length, 15mm dia PVC connection 450mm long including PTMT nuts and all necessary inlet outlet connections (excluding tap) complete all as specified and as directed. Make: Hindware CAT Part No. 91064, or equivalent of makes as per Appx 'A' as approved by GE
S&F in repair vitreous chinaware EWC including connection to drain or outgoing pipe and to PVC flushing pipe, antisyphonage pipe, of approval Make and all necessary fittings etc complete all as directed and specified incl PVC seat cover.
Supply and fix in repairs 10 litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets, 32mm dia PVC flush pipe and connections to pipes, making good the disturbed surfaces complete all as specified and as directed.
S&F stainless steel health faucet witrh 1 Mtr tube and hook complete all as specified and directed ny Engr-in-charge. Confirming to Cat part No ALD573 of jaguar completed all as specified
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall fixed complete all as specified and directed
S&F PVC (SWR) bends, 75 mm bore, any radius with access door complete all as specified and directed.
S&F PVC (SWR) Junction, single, (single T) equal or unequal, 110 mm bore,with access door complete all as specified and directed.
M&L for PVC (SWR) vent cowl, 110 mm bore complete all as specified and directed.
S/F in repair 75 mm bore PVC (SWR) floor trap plain with grating incl jointing with solvent cement
Material and labour for 18 to 20mm thick granite (of any type) work ( table rubbed and polished) in steps , jambs. pillars, window cills, cooking platforms and any other platform like in cement mortar (1:4) over and including 10mm thick backing coat in cement mortar (1:3), pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting, edge moulding, full curving the edges complete all as specified and as directed.
Labour only for full round moulding to 18 to 20mm thick granite slab all as directed by Engineer-in-Charge.
Material and labour for preparation of New plastered or unplastered surfaces of walls , applying birla putty whereever required, smoothen the surface with sand paper and finally applying one coat of acrylic distemper complete all as specified and as directed.
M&L for complete removal of existing treatment on walls using steel wire brush, sanding machine, rubbing ivory papers etc and washing , rubbing down and stopping of distempered and painted surfaces, preparing surfaces plastered or unplastered surfaces ready to receive new finish complete all as specified and directed.
M&L for applying wall care putty 1 to 1.5mm thick on walls/celing surfaces etc complete all as specified
M&L for applying one coat of alkali resistant priming paint on wall/celing etc complete all as specified
M&L for two coats of acrylic distemper of approved tint on wall surfaces etc complete all as specified
M&L for preparation of surfaces and applying one coat of 100% acrylic exterior emulsion paint to mangalore tiles, roof, wall ,floor etc, on buildings complete all as specified and as directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as directed.
Material and labour for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular), area of each tile exceeding 0.06sq.m but not exceeding 0.11sq.m as in floor etc., colour and pattern as approved by GE, set and jointed in neat cement slurry using grey cement and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and as directed.
M&L for coloured glazed ceramic tiles of size 600mm x 300mm x 7 to 8mm thick highlighter tiles of colour and pattern as approved by GE, as in vertical surface, set and jointed in neat cement slurry using grey cement and pointed in coloured cement to match the colour of tiles over and including 10mm thick rendering in cement mortar 1:3 including dismantling existing tiling, cement mortar bedding (but not backing), removing rubbish off the premisescomplete all as specified & directed.
M&L for coloured glazed ceramic tiles of size 600mm x 300mm x 7 to 8mm thick of colour and pattern as approved by GE, as in vertical surface, set and jointed in neat cement slurry using grey cement and pointed in coloured cement to match the colour of tiles over and including 10mm thick rendering in cement mortar 1:3 including dismantling existing tiling, cement mortar bedding (but not backing), removing rubbish off the premisescomplete all as specified & directed.
Demolition of Concrete (un reinforced) in ground floor and paving n. exceeding 15 cm thk (below or above ground level).
Supply only Integral liquid waterproofing compound as per manufacturers instructions.Make : Dr Fixit or euivalent
M&L for disconnecting existing water tanks setting aside (for lowering if required ) for repairs , cleaning etc and hoisting if required reconnecting and re-fixing in position capacity of watertank exc 500 but n exc 1000 litres complete all as specified and as directed.
M&L for disconnecting existing water tanks setting aside (for lowering if required ) for repairs , cleaning etc and hoisting if required reconnecting and re-fixing in position capacity of watertank exc 250 but n exc 500 litres complete all as specified and as directed.
Refixing 20 mm dia old steel tubing and connections in new or old position (Walls, ceiling, floors, etc Taking up or down steel tubing and connections, including cleaning for re-fixing or removal 20mm dia.
Refixing 15 mm dia old steel tubing and connections in new or old position (Walls, ceiling, floors, etc including taking up or down steel tubing and connections, including cleaning for re-fixing or removal 15mm dia.
M&L for GI tubing 15mm dia medium grade with all fittings & fixed complete to walls & ceiling or laid in floors in repairs including Taking up or down steel tubing and connections, including cleaning for re-fixing or removal 15mm dia.
M&L for GI tubing 20mm dia medium grade with all fittings & fixtures complete laid in trenches fixed in repairs including Taking up or down steel tubing and connections, including cleaning for re-fixing or removal 25/32 mm dia.
M&L for GI tubing 25mm dia medium grade with all fittings & fixtures complete laid in trenches fixed in repairs including Taking up or down steel tubing and connections, including cleaning for re-fixing or removal 25/32 mm dia.
Material and labour for removing of plants, bushes, weeds with roots from walls, roofs, chajja, canopy, parapets, roof kerbs, around water tanks, stagings, outlets junctions of water pipe lines, waste water pipe, bends or as directed and filling the disturbed area with cement concrete (1:1.5:3) or cment motar (1:3) using water proofing compound as per manufacturer's instruction and making the patch finished as per existing surroundings complete all as specified and as directed. (Note: Rate quoted is deemed to be included for scaffolding, safety measured required for working on or up to the height of 15 metres vertical or steep slopes)
S& F 1000 ltrs capacity of PVC Rotational moulded polyethylene water storage tanks ISI Marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 25mm size brass float valve, high pressure PTMT, with polythene float and flynut and connected fittings including Dismantling water tanks and removing to store exceeding 500 ltrs of capacity and not exceeding 1000 ltrs capacity.
S& F 500 ltrs capacity of PVC Rotational moulded polyethylene water storage tanks ISI Marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including Dismantling 500 ltrs capacity water tanks including 25mm size brass float valve, high pressure PTMT, with polythene float and flynut and connected fittings and removing to store as directed.
S & F with wall UPVC SCH-40 Gde 150 mm bore rain water pipe as in down take with necessary fitting to fix with wall and to connect with strome water drain etc all as specified as directed by Engr-in-Charge.
M & L Air termination, single pointed, copper rod 12mm dia and 300mm long etc complete as all specified.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw etc complete as all specified.
Supply and fix Earth continuity conductor or Main Earthing lead fixed to wall or batten or reccess or chasses or buried in ground or drawn in conduit / pipe or fixed to Poles or any other indicated situation for loop copper strip of size 20 x 3.15 mm connected to test point complete all as specified and as directed.
Material & labour for Earthing using Copper earth plate electrode of size 600mm X 600mm X3mm thick burried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers including refilling with good earth as specified and electrode connections by using Copper strip of size 20x3mm by means of bolts, nuts, check nuts and washers made of copper/brass and provision of GI pipe medium grade 25 mm dia for protection of earthing lead and 20mm dia for watering arrangement including funnel, wire mesh, readymade PVC Chamber & cover with PCC 1:2:4 type B-2 (including necessary excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown on plate No 5 of SSR Part-I 2009
M&L Cement Concrete 1:3:6 type c -2 (40mm graded aggregate) as in Foundation of Poles,/ coping etc. including Formwork (as/if required) complete all as specified and as directed.
Material and Labour for Tubes, 'Medium grade' galvanised, bore of pipe 40mm with all fitting and fixed to walls and ceilings or laid in floor complete all as specified and as directed.
Supply and fixing DMC isolation Insulator, Rated Voltage 415 Volt, red in colour 30mm dia for fixing copper earthing strip with necessary copper nut botls washers including grounting on wall, ceiling, roof complete all as specified and as directed.
Supply & laying LT UG XLPE sheathed PVC insulated screened, PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 Volt grade, cross-sectional area 16 Sqmm 4 core, laid in trenches / on surface of wall / along with Pole in and passing through cable protection corrugated pipe & connecting to OH Lines or switch fuse unit and testing, complete all as specified and as directed.
Supply and laying Double Wall Corrugated ( DWC ) HDPE pipes of size 50 mm, chemical resistance, flexible, tough along with accessories such as coupler and bend, with rubber O ring for electrical applications as in cable protection pipe complete all as specified and as directed.
S&F MCCB 4 Pole, 415 Volts, with Thermal release range 100 (A) breaking capacity 25 KA , Ics = 100% Icu, Thermal Magnetic : O/L & S/C protection, connecting cables of any size, testing , complete all as specified and as directed.
“Supply & Installation PVC Cable tray Confirming to BS EN 61537 (Length 3 m) Width x Depth (mm)- 150x 50mm, corrosion resistance for indoor/ outdoor application, including necessary covers , couplers , support and accessories, for fixing to walls/ ceilings as per site requirement complete of Make Legrand Cat No - 6377 21 or equivalent all as specified and as directed”
Excavation in Trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable/ foundation of Pole / Stays / Pipe etc getting out in soft loose soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Leveling, Watering and Well ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed.
Removing Surplus soils to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed.
Material and labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty PVC concealed conduit including all accessories after chasing in walls etc with Metal flush box of suitable module, with earth dolly, covered with modular white cover plate & frame for modular switches , including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed for the following
(a) One light point controlled by one, one way switch 6 Amps
(b) One fan point / exhaust point/wall fan point ceiling from controlled by one, one way switch 6 Amps complete all as specified and as directed
(c) One 5 point 6 Amps switch socket outlet point controlled by one switch on same board
(d) One 5 pin 6 Amps switch socket outlet point controlled by one, switch on independent board
(e) One bell point controlled by one, one way switch 6 Amps complete all as specified and as directed
- Ditto- all as per item No 119 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 5 pin socket outlet plug point, 6 Amps independent including necessary running of 2.5 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed
- Ditto- all as per item No 119 here-in before but using 4.0 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for 6/16 Amps power point including necessary running of 4.0 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly all as specified and as directed
S & F Modular switch piano flush type, single pole , one way, and 5/ 6 Amps, single module complete all as specified and as directed.
S & F Modular switch piano flush type, single pole , one way, and 15/16 Amps, single module complete all as specified and as directed.
S & F Modular socket outlet multipurpose, having provision for 3 pin 5/6 Amp, 2 module piano flush type, complete all as specified and as directed.
S & F Modular socket outlet multipurpose, having provision for 3 pin 15/16 Amp, and 3 pin, 5/6 Amp, 2 module piano flush type, complete all as specified and as directed.
Supplied & fixed sheet Metal enclosure with a two pin and earth socket plug top and with one single pole MCB 20 Amps , 240 Volt complete all as specified and as directed.
Supply and fixing Modular Bell push 6A ,one module complete all as specified and as directed.
Supply and fixing electric bell suitable for operation on AC. 230 volts, single pole complete all as specified and as directed.
S & F modular ceiling fan regulator, electronic step type, 120 watt 2 module suitable for 230V 50Hz AC supply complete all as specified and as directed.
Supply and fixing ceiling fans working on single phase input voltage 140-285 , Sweep- 1200 mm, Power 32 W, 345 RPM , with 232 Air delivery CMM (m3 /min), complete with compact BLDC Motor, blades, down rods, and accessories, including making connections with provision of flexible wire 23 /0.0076 twin core copper conductor from ceiling rose/connector to fan complete all as specified & as directed. Make- Atomberg (NAVEO)
Supply and fixing Energy Efficient BLDC Motor, wall mounted fan , Power-32 W consumption on high speed, Input voltage 90-245 V-AC single phase, Speed: 1350 RPM ,50 Hz , 400 mm sweep, 3 blade, and making connections complete all as specified & as directed. Make- Atomberg (EFFICIO +)
S & F Ceiling rose, 3 terminal, surface bakelite suitable ISI marked for batten fittings complete all as specified and as directed
S & F Lamp holder, (Angle/ bracket) insulated body, with back plate for batten fittings complete all as specified and as directed
Supply only Highly efficient LED Bulbs, 10 W, used as a ready replacement for existing GLS/ CFL direct fit lamp, in B-22 cap complete all as specified and as directed
S & F LED light fitting 1x9W / 1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed
Supply and fixing LED lights fitting 1x 22 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
S & F sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 440 Volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and as directed
Supply and fixing amp rating 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN 40 To 100 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP 5 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed
M&L for Earthing complete with galvanized steel earth plate electrode 600mmx600x6mm thick buried vertically directly in ground (Earth pit not less than 2.25mtr deep below normal ground level and top edge of the plate not less than 1.5 mtr below ground level), connected to and including galvanized steel eathing lead wire 4 mm dia by means of bolts nuts check nuts and washers etc GI pipe 15mm dia medium grade for protection of GI strip both to be provided to the extent of 7.5 meters, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/ plinths or fixed on walls oe concealed in walls etc with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate , including readymade PVC Chamber & cover with GI 20 dia medium grade pipe and MS funnel with wire mesh for watering arrangement including necessary excavation and earth work in any type of strata and testing on completion. Note:- GI wire 4.0 mm dia and GI pipe 20 mm bore medium grade for encasing GI wire 4.0 mm dia beyond 7.50 M length per earthing if so required at site shall be measured and paid for seperately under relevant items.
Taking down carefully exising unserviceable aluminium point wiring (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately and making dood disturbed surfaces of wall, floor etc. complete all as specified and as directed.
Taking down of old unserviceable sub main wiring of any type complete all as specified and as directed.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes all as specified.
S & F for wall mounted LED 20 watts with out put of 1800 lumens , box type (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4' x 20 watts complete all as specified and as directed.
S & F for LED 10 watts batten aluminium extruded with decorative end caps complete all as specified and as directed. Make- Bajaj Cat Part No BCLSB 10 NW or its equivallent model in Wipro, Havells, Philips.
S & F Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and as directed. Make :- Bajaj Cat No BIBWP 10W LED or its equvalent in Philips, Wipro, Havells.
S & F for MCB DB, SPN, sheet metal enclosure, 8 way with 200 amps rated bus bar double door, fixed on wall good to disturbed surfaces, and connecting with existing cable complete all as specified and directed.
S & F for MCB Single pole and neutral rated capacity 40 amps, 240 volts breaking capacity 10 KA complete all as specified and as directed.
S & F for MCB Single pole rated capacity 5 to 32 amps, 240 V breaking capacity 10 KA complete all as specified and as directed.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with multistranded copper conductor of size 4.0 Sq mm nominal area and drawn through PVC non metallic rigid PVC casing caping and its accessories including one run of PVC insulated 4 Sq mm (nominal area) multistranded copper conductor FRLS cable as earth wire and connected from DB to DB/ main board complete all as specified and as directed. Note:- Two runs of 4 sqmm cable,one run of 4 sqmm cable and one run of PVC casing caping and accessories will be measured as one unit
Supply and fix exhaust fan, AC single Phase, working on input voltage 140-285 , of size 250 mm sweep, 1200 RPM, Power 20 W with BLDC Motor, blades, frame and louvers provision of 3 core 1.5 sq. mm copper conductor PVC insulated & PVC sheeted flexible wire from ceiling rose/connector to fan including making connections complete all as specified & as directed . Make- Atomberg (EFFICIO)
Supply and fix Rigid non-metallic PVC conduit of size 25mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, locknuts, saddles, pipe hooks etc.
Supply & laying LT UG XLPE sheathed PVC insulated screened, PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 Volt grade, cross-sectional area 10 Sqmm 4 core, laid in trenches / on surface of wall / along with Pole in and passing through cable protection corrugated pipe & connecting to OH Lines or switch fuse unit and testing, complete all as specified and as directed.
Supply and laying Double Wall Corrugated ( DWC ) LDPE pipes of size 40 mm, chemical resistance, flexible, tough along with accessories such as coupler and bend, with rubber O ring for electrical applications as in cable protection pipe complete all as specified and as directed.
S&F for wall mounted 20 watts indoor inverter batten with opal diffuser, IP 20, with 4 hrs back up with output of 1800 lumens, box type (decorative) light fitting, 230 volts with extruded aluminimum heat sink provided for efficient heat dissipation and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessray mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fiitng including LED tube 4' x 18 watts complete all as specified and as directed Make : Halonix Cat part No LED INVERTER Batten HLB - 08-20-CW-INV or equivalent in Wipro, jaquar, philips, havells
Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site.
VISALAKSHI WATER PROOFINGCOMPANY PRIVATE LTD
ganesh electricals and airconditioners
Ganesh Sonajirao Garje
M/S Eknath agencies
Vijay Construction and Company
M/S OMSAI ENTERPRISES
Galaxy Construction
Parhar Enterprise
m/s Aura Enterprises
R k construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .