Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹25.9 L
EMD Value
₹52,000
Closing Date
12 Oct 2020, 3:00 pmClosed
Project Manager
PROJECT MANAGER, UNIT-10, Udayog Kunj Road, Dada Nagar, Kanpur
CONSTRUCTION OF VETERINARY HOSPITAL BUILDING AT - SHIWALI, DISTT KANPUR DEHAT
2020_UPPRC_514683_4
13/PCL/PM-10/2020-21
Open Tender
Civil Works
Item Rate
120 days
Kanpur
CONSTRUCTION OF VETERINARY HOSPITAL BUILDING AT - SHIWALI, DISTT KANPUR DEHAT
2 documents required · 2 mandatory
₹2,360
Project Manager, Unit-10
₹52,000
19 Oct 2020
3 Oct 2020
12 Oct 2020
3 Oct 2020
12 Oct 2020
3 Oct 2020
Amount
Hospital Building
Exacavation in foundations in ordinary soil(loam clay or sand) including lift upto 1.5 m and lead upto 30m.and including filling watering and ramming of exacaveted earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal disposal of surplus excavated earth as directed by the Engineer i/c with in a charge upto a distance of 30 m from the foundation trenches.
Local Sand (compacted) filling in sides of foundation & floor
Cement concrete with 4 cm gauge approved stone ballast ,approved coarse sand and cement in the proportion of 1:4:8 (1 cement :4 coarse sand :8 stone) and curing complete,including suply of all materials labour and tools and plants etc. required for proper completion of the work
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters /sqm (5)Treatment of soil along external perimeter of building 7.5 liters/sqm. (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)
M-150 Sub class brick work in 1:6 cement and coarse sand of 2.26 fineness modulus mortar in foundation and plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work.
M-150 Sub class brick work in 1:6 cement and coarse sand of 2.26 fineness modulus mortar in Super Structure including supply of all materials, labour, tools and plants etc. required for proper completion of the work.
M-150 Sub class brick work in 1:3 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit in the proportion of 1:1.5:3 in Slab excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Counter Slab
M.S. ( tor steel or plain work such as R.C.C.or R.B. Work including bending for proper shape and including supply of steeel & its wastage ,bend ,hooks authorised over lapping shall be measured and including cost of building wire.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35mm thick including ISI marked stainless steel but hinges with necessary screws.
15 mm cement plaster on rough side of single or half brick wall of mix: 1:3 (1 cement: 3 coarse sand)
12 mm cement plaster and fine sand of 1.25 fineness modules in 1:3 over brick work miniumum thickness not to be less than 1cm .including supply of all materilas ,labour ,tools & plants etc.required for proper completion of the work . Fair side of surface
12 mm cement plaster and fine sand of 1.25 fineness modules in 1:3 over brick work miniumum thickness not to be less than 1cm .including supply of all materilas ,labour ,tools & plants etc.required for proper completion of the work . in Interior side plaster
Providing and laying "brick coba" 12mm thick laid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finised smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono tythic plaster wall up to 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonany Coba with top finised plaster mixed with acetic water proofing compound @ 2% by weight & including s/o all material, labour, T& P etc complete for proper completion of work.
Providing and laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size with all colours and shades, laid on 20mm thick cement mortar 1:3 (1 cement : 3 coarse sand) finishing with cement slurry & with pigment grouting & polishing complete including supply of all materials, labour, T & P etc. required for proper completion the work. Flooring
Providing and laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size with all colours and shades, laid on 20mm thick cement mortar 1:3 (1 cement : 3 coarse sand) finishing with cement slurry & with pigment grouting & polishing complete including supply of all materials, labour, T & P etc. required for proper completion the work. Skirting
Providing & laying of 20mm thick white Kota Stone flooring over 20 mm thick base of cement mortar 1:4 cement and coarse sand laid over jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing & polishing complete.
Kota stone slab 20 mm thick in riser of steps, skirting, dado & pillars laid on 10 mm thick mortar 1:3 (1 cement : 3 coarse sand), jointed with grey cement slurry mixed with pigment to match the shade of slabs including rubbing and polishing complete.
Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor).
Painting or Varnishing on iron works in small araes or new Steel surface with one coat over of ready mixed priming paint &one coat of approved superior mixed paint of clear synthetic enamele varnish including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work.Paint to be used shold confirm to the I.S.I. No.103 1950
Painting or Varnishing on iron works in small araes or new Wooden surface with one coat over of ready mixed priming paint &one coat of approved superior mixed paint of clear synthetic enamele varnish including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work.Paint to be used shold confirm to the I.S.I. No.103 1950
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shadeNew work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Distempering (first coat) with oil bound distemper of approved brand and manufacture & of required shade on under corated wall to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials.labour , tools ,& plants etc required for
Distempering (first coat) with oil bound distemper of approved brand and manufacture & of required shade on under corated wall to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials.labour , tools ,& plants etc required for Ceiling surface
Providing and applying white cement based putty of average thickness 1 mm, of approved brand & anufacturer, over the plastered wall surface to prepare the surface even & smooth complete.
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes
Providing and fixing ISI marked S.S. sliding door bolts with nuts and screws etc. complete 300x16 mm
Providing and fixing ISI marked S.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete 250x10 mm
Providing and fixing ISI marked S.S. handles conforming to IS:4992 with necessary screws etc. complete 150 mm
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved lead paint.
Construction of drain along apron (150 x 150mm)
Exacavation in foundations in ordinary soil(loam clay or sand) including lift upto 1.5 m and lead upto 30m.and including filling watering and ramming of exacaveted earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal disposal of surplus excavated earth as directed by the Engineer i/c with in a charge upto a distance of 30 m from the foundation trenches .
Carted earth filling in floor & trench including watering,ramming,consolidating and dressing complete including lead up to 50 m and lift upto 1.5 m and including cost of sand
Sand (compacted) filling in sides of foundation & floor for saltpeter treatment.
Cement concrete with 4 cm gauge approved stone ballast ,approved coarse sand and cement in the proportion of 1:4:8 (1 cement :4 coarse sand :8 stone) and curing complete,including suply of all materials labour and tools and plants etc.required for proper completion of the work
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters /sqm (5)Treatment of soil along external perimeter of building 7.5 liters/sqm. (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)
M-150 Sub class brick work in 1:6 cement and coarse sand of 2.26 fineness modulus mortar in foundation and plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work.
Painting on D.P.C.with two coats of air blown bitumen 85/50 or 85/25 @ 1.7 kg/sqm.Approx including cost of fuel if any.
M-150 Sub class brick work in 1:6 cement and coarse sand of 2.26 fineness modulus mortar in Super Structure including supply of all materials, labour, tools and plants etc. required for proper completion of the work.
M-150 Sub class brick work in 1:3 cement and coarse sand of 2.26 fineness modulus mortar in Super Structure including supply of all materials, labour, tools and plants etc. required for proper completion of the work. wall thickness 12 cms & below brick work.
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works.
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in Slab excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works.
M.S. ( tor steel or plain work such as R.C.C.or R.B. Work including bending for proper shape and including supply of steeel & its wastage ,bend ,hooks authorised over lapping shall be measured and including cost of building wire.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 MM thick
M.s. or iron works of small sizes and section such as holding down bolts. Hold fast the grating etc. wrough to required from including supply of steel bolts .nuts wastage etc. and their fixing requred for proper completion of the work.(a) Providing & fixing of door / windows grill.stair case railing
Providing & fixing of Z-section window. Openable
Angle iron (40*40*5MM)
Fixing of chaukhat (Labour rate only) (a) Door chaukhat
Ventilator chaukhat
15 mm cement plaster on rough side of single or half brick wall of mix: 1:3 (1 cement: 3 coarse sand)
12 mm cement plaster and fine sand of 1.25 fineness modules in 1:3 over brick work miniumum thickness not to be less than 1cm .including supply of all materilas ,labour ,tools & plants etc.required for proper completion of the work . Fair side of surface
12 mm cement plaster and fine sand of 1.25 fineness modules in 1:3 over brick work miniumum thickness not to be less than 1cm .including supply of all materilas ,labour ,tools & plants etc.required for proper completion of the work . in Interior side plaster
Providing and laying "brick coba" 12mm thick laid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finised smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono tythic plaster wall up to 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonany Coba with top finised plaster mixed with acetic water proofing compound @ 2% by weight & including s/o all material, labour, T& P etc complete for proper completion of work.
Supply and fixing 6mm china white cement glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete ,including supply of all materials ,labour and tools and plants. Flooring
Supply and fixing 6mm china white cement glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete ,including supply of all materials ,labour and tools and plants. Skirting
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement. 40mm thick.
2 cm thick cement plaster in dedo or skirting in 1:3 consisiting of one part of cement and 3 parts of approved coarse sand laid panels ,finished with 3 mm .floating coat of neat cement or cement and marble dust in ratio of 5;1 including supply of all materials ,labour and T&p etc.required for proper completion of work.
Providing and fixing glass strips of 4mm (1/8") Thickness in joints of floor and skirting at the time of laying , labour ,tools plants etc.complete.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement. But floor shall be 2.5 cm thick and without base concrete
Painting or Varnishing on iron works in small araes or new Steel work with one coat over of ready mixed priming paint &one coat of approved superior mixed paint of clear synthetic enamele varnish including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work.Paint to be used shold confirm to the I.S.I. No.103 1950
Painting or Varnishing on iron works in small araes or new Wood work with one coat over of ready mixed priming paint &one coat of approved superior mixed paint of clear synthetic enamele varnish including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work.Paint to be used shold confirm to the I.S.I. No.103 1950Aa in item (641) above but for every coat after first coat.
Finishing wall with water proof cement paint of approved quality such as Snowcem, Durocem of required shade on undecorated wall surface to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials including curing & cost of all materials labour T&P etc complete.
Distempering (first coat) with oil bound distemper of approved brand and manufacture & of required shade on under corated wall to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials.labour , tools ,& plants etc required for Inner wall side
Distempering (first coat) with oil bound distemper of approved brand and manufacture & of required shade on under corated wall to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials.labour , tools ,& plants etc required for Ceiling surface
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :DSR (900.55) 4.0 mm thick glass panes
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, with necessary screws etc. complete :200x10 mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :125 mm
Providing & fixing white vitereous china water closet squattingpan ISI marked (Indian type W.C. pan) with 100 mm sand cast iron P or S trap , 10/12.5 lits PVC low level flushing cistern with fittings & brackets 40 mm dia C.P. flush pipe with fitting & clams 20 m over flow pipe with specials and mosquito proof coupling of approved municipal design painting wherever required including cutting & making good the walls & floors where required. Orissa Pattern W.C. pan of size 580 X 440 m with integral type foot rests flush pipe and over flow arrangement.
Providing & Fixing white vitreous china wash basin with C.I. brackets painted white 15 mm C.P. brass pillar taps , C.P. brass chain with rubber plug 32 mm C.P. brass waste of standard pattern including cutting & making good the walls wherever required. (a) Flat back wash Basin size 550 X 400 mm with Single 15 mm C.P. brass pillar tap.
Providing & Fixing Flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. (a) 32 mm dia
(b) 40 mm dia
Providing & fixing Stainless Steel A ISI 304(18/8) sink as per IS 13983 with C.I. brackets , stainless steel plug 40mm including , including painting the fitting and brackets,cutting and making good the walls wherever required.size 600 X 450 X 250 mm.
Providing & Fixing soil , waste and vent pipes (a) 100 mm dia PVC pipe
(b) 75 mm dia PVC pipe
Providing & Fixing M.S. holder bat clamps of approved design to PVC pipe embeded and including cement concrete blocks 10 X 10 X 10 cm of 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size ). Including cost of cutting holes & making good the walls etc.(a) for 100 mm dia pipe
(b) for 75 mm dia pipe
Providing & fixing PVC trap of self cleansing design with or without ventarm complete including cost of cutting & making goods the wall & floors (a) 100 mm inlet & 75 mm outlet.
Providing & Fixing bend of required degree with access door , insertion rubber washer 3 mm thick bolts and nuts complete. (a) 100 mm dia
(b) 75 mm dia
Providing & Fixing 125mm dia PTMT grating of approved quality & clolour.
Providing & fixing GI pipes complete with GI fittings & clamps including cutting & making good the wall etc.(internal work)(i) Exposed on wall (a) 15 m dia nominal bore (medium duty)
(b) 25 m dia nominal bore (medium duty)
Painting GI pipes and fittings with synthetic enamel white paint over a ready mixed priming coat , both of approved quality for new work. (a)15 mm dia nominal bore
(b)25 mm dia nominal bore
Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions (a) 15 mm nominal bore
Providing & fixing brass bib cock of approved quality conforming to IS 8931 (a) 15 mm nominal bore
Providing & fixing ball valve (brass) of approved quality complete (High or low pressure with plastic floats) (a) 25 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ofapproved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but capacity 200 liter.
Providing and Fixing brass stop cock of approved quality (b) 15 mm nominal bore
Providing and fixing GUN metal gate valve with wheel of approved quality a)25mm dia Nominal bore
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. a) 110 mm diameter
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall. a) 110mm
Excavating trenches in all kind of soil of required width for pipes,cables etc including excavation for sockets and dressing of sides,ramming of bottoms , depth upto 1.5 m including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming , watering etc & disposing of surplus excavated soil as directed within a lead of 50 m (a) Pipes 80 mm to 300 mm diameter.
Providing laying and joining glazed stone ware pipes grade 'A' with stiff mixture of cement mortar in the propotion of 1: 1(1 cement : 1 fine sand ) including testing of joints etc. complete. (a) 100 mm diameter
Providing & laying cement concrete 1:5:10 (1 cement : 5 coarse sand :10 graded stone aggregate 40 mm nominal size) alround S.W. Pipes including bed concrete as per standard design (a) 100 mm diameter S.W. Pipe
Providing and Fixing square mouth S.W. Gully trap 'A' Complete with C.I. grating brick masonry chamber with F.P.S. bricks of class designation 75 and water tight C.I. cover with frame of 300 X 300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 kg as per standard design. (a) 150 X 100 mm size P type
Constructing Brick masonry manhole with 75 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plasstering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design. (a) Inside size 90 X 80 cm & 45 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg. (wt. of cover 23 Kg. & wt of frame 15 Kg.)
(b)Extra for depth of man hole size 90 X 80 cm
Wiring points for light with 1 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FR PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects.but in PVC conduit with 1.5sq.mm. PVC insulated copper conductor cable as earth wire drawn inside the conduit.
Wiring points for two way light. with 1 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FR PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects. but in PVC conduit with 1.5sq.mm. PVC insulated copper conductor cable as earth wire drawn inside the conduit.
Wiring points for fan and light duty exhaust fan. with 1 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FR PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects. but in PVC conduit with 1.5sq.mm. PVC insulated copper conductor cable as earth wire drawn inside the conduit.
Wiring points for 5 amp plug point with 1 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FR PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects. but in PVC conduit with 1.5sq.mm. PVC insulated copper conductor cable as earth wire drawn inside the conduit.
Supply and fixing of power plug with 15A/250 V flush type switch and 3 Pin 15 A/250V flush type socket in suitable M.S. box of 175mmx100x50mm size Switch bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer.
Supply and wiring of two number 4 aq mm.PVC isulated 1100 V grade single core aluminium conductor cable in 20 mm dia heavy guage rigid steel conduit on surface, with one number 8 SWG GI earth continuity wire,etc complete in all respect
Supply fixing and concealing of 20mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work . ( for Telephone)
Supply fixing and concealing of 20mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work . ( for Telephone) but 25mm dia 2mm thick PVC conduit.
Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects.
S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide & screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T&P etc., for proper completion of work.
Supply and erection of AC 1200mm Sweep, 230/250 Volts, 50 Hz ceilling fan with regulater standar down rod, blades including connection etc. complete as required
Supply and fixing of flush/surface mounting distribution boards complete in all respects. a) {8 Way SPN} 12 WAYS
S/F of 6/10/16/20/25/32 amp. SP MCB (10 KA)
S / F of 63 AMP SP MCB (10KA)
Construction of recess distribution board of all sizes including cutting of brick work providing lintel of suitable size & thickness plastering etc. with supply of all materials, labours, T & P etc. required for proper completion of work. a) 600x480x200 mm. size
Supply and fixing of factory fabricated M.S. box in existing sunk with Godrej type almirah cover with handle etc. fabricated from 18 SWG M.S. sheet duly painted with red oxide primer followed by two coats of synthetic enamel paint complete with necessary conduit entry and DP/TPN; fixing arrangement and provision for compartment for loose wires, openable housing on the top and hold fast etc. including supply of all material, labour and T & P etc. required for proper completion of the work. a) 600x480x200 mm. size
Supply & burying of 600mm x 600 mmx6mm Copper plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering & one earthing leads of one No. 8 SWG copper.wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and Copper wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke & salt at least 150mm thick alround etc. complete in all respects.
Supply & fixing of one number 8 SWG G.I. wire in 15mm dia G.I. Pipe of earthing, laid in ground or in wall duly conceale including the cost of cement, sand, labour, T&P other material required for proper comletion of the work. a) Same as PS 721 but with one number 8 SWG copper wire.
Supply & laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround & protected with burnt bricks on sides, top on surface, cable run shall be fixed on M.S. clamps etc. a) 2.0 core 10 sqmm
Supply & fixing of single light wall bracket on matching M.D.F.E.G. board base etc.Category A.
Supply & fixing of LED Tube Light with batten suitable for up to 1 x 22 watt LED tube light complete including tube etc on surface complete in all respects.(CAT: AAA)
S / F factory wired, HPF box type, fluorescent tube light fitting suitable for 10 to 15watt fluorescent tube complete including tube etc. on surface complete in all respect. (Mirror Light)
S/F of 2 pin Telephone outlet with metal box 100 X 100 X 60 mm deep (nominal size) on surface or in recess with suitable size of 3mm thick phenolic laminated sheet cover in the front including painting etc. as required 1 Nos. 2 Pin Tel. Outlet
Providing, drawing, connecting and testing of telephone wire 0.51sq.mm. tinned copper conductor PVC insulated, PVC sheathed in existing conduit from telephone outlet box to the junction box / tag block. (2 pair 0.51 sq. mm. )
Earth work in excavation (PWD-251)
P.C.C. in Foundation (1 :4 :8) (PWD-281)
1st Class B/W in Septic tank (1cement : 6 coarse sand)
R.C.C. work in septic tank
M.S. work in R.C.C. (PWD-504)
12 mm thk Plastering inside septic tank (PWD - 17.58,i)
Providing M.S. foot rest including fixing with 20 x 20 x 10 cm cement concete block 1:3:6 (1 cement : 3 coarse :6 graded aggregate of nominal size 20 mm ) as per standard with 20x20 mm sqm. bar. D.S.R.- 19.15.1
Providing & fixing soil, wast and vent pipe. (a) 75 mm dia sand cost iron S&S pipe. D.S.R.- 17.35.2.1
Providing & fixing sand cost iron terminal guard 75 mm dia. D.S.R.- 17.56.2.1
Providing & fixing plane sand cost iron S&S bend of required degree. D.S.R.- 17.38.2.1 75 mm
Providing lead caulked joints to sand cost iron/ cetrifugally cast (squn) irons pipes & fitting of dia. D.S.R.- 17.58.2 75 mm
S.W. Tee 100 mm dia with one leg of 40 cm with fixing in inlet and outlet. (DSR-7087)
75 mm dia cowl at top of Ventilating pipe. (DSR-3734)
Supply & fixing of medium quality R.C.C. Manhole cover with frame complete.MD.-10-Circular shape, 500 int. dia. D.S.R.- 19.19.2.2
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR-19.32.1)
Exacavation in foundations in ordinary soil(loam clay or sand) including lift upto 1.5 m and lead upto 30m.and including filling watering and ramming of exacaveted earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal disposal of surplus excavated earth as directed by the Engineer i/c with in a charge upto a distance of 30 m from the foundation trenches.
Sand (compacted) filling in sides of foundation & floor
Cement concrete with 4 cm gauge approved stone ballast ,approved coarse sand and cement in the proportion of 1:4:8 (1 cement :4 coarse sand :8 stone) and curing complete,including suply of all materials labour and tools and plants etc.required for proper completion of the work
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters /sqm (5)Treatment of soil along external perimeter of building 7.5 liters/sqm. (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)
M-150 Sub class brick work in 1:6 cement and coarse sand of 2.26 fineness modulus mortar in foundation and plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work.
Painting on D.P.C.with two coats of air blown bitumen 85/50 or 85/25 @ 1.7 kg/sqm.Approx including cost of fuel if any.
M-150 Sub class brick work in 1:6 cement and coarse sand of 2.26 fineness modulus mortar in super structure including supply of all materials, labour, tools and plants etc. required for proper completion of the work.
M-150 Sub class brick work in 1:6 cement and coarse sand of 2.26 fineness modulus mortar in super structure including supply of all materials, labour, tools and plants etc. required for proper completion of the work.but in 1:3 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works.
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in Slab excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works.
M.S. ( tor steel or plain work such as R.C.C.or R.B. Work including bending for proper shape and including supply of steeel & its wastage ,bend ,hooks authorised over lapping shall be measured and including cost of building wire.
15 mm cement plaster on rough side of single or half brick wall of mix: 1:3 (1 cement: 3 coarse sand)
12 mm cement plaster and fine sand of 1.25 fineness modules in 1:6 over brick work miniumum thickness not to be less than 1cm .including supply of all materilas ,labour ,tools & plants etc.required for proper completion of the work .Fair side surface
12 mm cement plaster and fine sand of 1.25 fineness modules in 1:6 over brick work miniumum thickness not to be less than 1cm .including supply of all materilas ,labour ,tools & plants etc.required for proper completion of the work but in Interior side plaster
Providing and laying "brick coba" 12mm thick laid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finised smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono tythic plaster wall up to 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonany Coba with top finised plaster mixed with acetic water proofing compound @ 2% by weight & including s/o all material, labour, T& P etc complete for proper completion of work.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement. 40mm thick.
2 cm thick cement plaster in dedo or skirting in 1:3 consisiting of one part of cement and 3 parts of approved coarse sand laid panels ,finished with 3 mm .floating coat of neat cement or cement and marble dust in ratio of 5;1 including supply of all materials ,labour and T&p etc.required for proper completion of work.
Providing and fixing glass strips of 4mm (1/8") Thickness in joints of floor and skirting at the time of laying , labour ,tools plants etc.complete.35mm depth
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement. But floor shall be 2.5 cm thick and without base concrete
Finishing walls with water proof cement paint of approved make and quality on new work with two coat to give an even shade including supply of all materials labour ,and tools plants etc.required for proper complrtion of the work .but for each coat of water proofing cement paint after the first coats to given and even shade.
Distempering (first coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials.labour , tools ,& plants etc required for Inner wall side
Distempering (first coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials.labour , tools ,& plants etc required for Ceiling surface
Exacavation in foundations in ordinary soil(loam clay or sand) including lift upto 1.5 m and lead upto 30m.and including filling watering and ramming of exacaveted earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal disposal of surplus excavated earth as directed by the Engineer i/c with in a charge upto a distance of 30 m from the foundation trenches.
Sand (compacted) filling in sides of foundation & floor for saltpeter treatment.
Cement concrete with 4 cm gauge approved stone ballast ,approved coarse sand and cement in the proportion of 1:4:8 (1 cement :4 coarse sand :8 stone) and curing complete,including suply of all materials labour and tools and plants etc.required for proper completion of the work
Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters /sqm (5)Treatment of soil along external perimeter of building 7.5 liters/sqm. (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)
M-150 Sub class brick work in 1:6 cement and coarse sand of 2.26 fineness modulus mortar in foundation and plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work.
Painting on D.P.C.with two coats of air blown bitumen 85/50 or 85/25 @ 1.7 kg/sqm.Approx including cost of fuel if any.
M-150 Sub class brick work in 1:6 cement and coarse sand of 2.26 fineness modulus mortar in super structure including supply of all materials, labour, tools and plants etc. required for proper completion of the work.
M-150 Sub class brick work in 1:6 cement and coarse sand of 2.26 fineness modulus mortar in super structure including supply of all materials, labour, tools and plants etc. required for proper completion of the work.but in 1:3 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works.
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in Slab excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works.
M.S. ( tor steel or plain work such as R.C.C.or R.B. Work including bending for proper shape and including supply of steeel & its wastage ,bend ,hooks authorised over lapping shall be measured and including cost of building wire.
15 mm cement plaster on rough side of single or half brick wall of mix: 1:3 (1 cement: 3 coarse sand)
12 mm cement plaster and fine sand of 1.25 fineness modules in 1:6 over brick work miniumum thickness not to be less than 1cm .including supply of all materilas ,labour ,tools & plants etc.required for proper completion of the work .Fair side surface
12 mm cement plaster and fine sand of 1.25 fineness modules in 1:6 over brick work miniumum thickness not to be less than 1cm .including supply of all materilas ,labour ,tools & plants etc.required for proper completion of the work but in Interior side plaster
Providing and laying "brick coba" 12mm thick laid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finised smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono tythic plaster wall up to 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonany Coba with top finised plaster mixed with acetic water proofing compound @ 2% by weight & including s/o all material, labour, T& P etc complete for proper completion of work.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement. 40mm thick.
2 cm thick cement plaster in dedo or skirting in 1:3 consisiting of one part of cement and 3 parts of approved coarse sand laid panels ,finished with 3 mm .floating coat of neat cement or cement and marble dust in ratio of 5;1 including supply of all materials ,labour and T&p etc.required for proper completion of work.
Providing and fixing glass strips of 4mm (1/8") Thickness in joints of floor and skirting at the time of laying , labour ,tools plants etc.complete.35mm depth
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement. But floor shall be 2.5 cm thick and without base concrete
Finishing walls with water proof cement paint of approved make and quality on new work with two coat to give an even shade including supply of all materials labour ,and tools plants etc.required for proper complrtion of the work .but for each coat of water proofing cement paint after the first coats to given and even shade.
Distempering (first coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials.labour , tools ,& plants etc required for Inner wall side
Distempering (first coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials.labour , tools ,& plants etc required for Ceiling surface
Exacavation in foundations in ordinary soil(loam clay or sand) including lift upto 1.5 m and lead upto 30m.and including filling watering and ramming of exacaveted earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal disposal of surplus excavated earth as directed by the Engineer i/c with in a charge upto a distance of 30 m from the foundation trenches.
Carted earth filling in floor & trench including watering,ramming,consolidating and dressing complete including lead up to 50 m and lift upto 1.5 m and including cost of earth
Sand (compacted) filling in sides of foundation & floor for saltpeter treatment.
Cement concrete with 4 cm gauge approved stone ballast ,approved coarse sand and cement in the proportion of 1:4:8 (1 cement :4 coarse sand :8 stone) and curing complete,including suply of all materials labour and tools and plants etc.required for proper completion of the work
M-150 Sub class brick work in 1:6 cement and coarse sand of 2.26 fineness modulus mortar in foundation and plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work.
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works.
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in Slab excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works.
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in Beam excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works.
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in Beam excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works.
R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in Raft foundation excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works.
M.S. ( tor steel or plain work such as R.C.C.or R.B. Work including bending for proper shape and including supply of steeel & its wastage ,bend ,hooks authorised over lapping shall be measured and including cost of building wire.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
15 mm cement plaster on rough side of single or half brick wall of mix:1:3 (1 cement: 3 coarse sand)
12 mm cement plaster and fine sand of 1.25 fineness modules in 1:3 over brick work miniumum thickness not to be less than 1cm .including supply of all materilas ,labour ,tools & plants etc.required for proper completion of the work .
Providing and laying "brick coba" 12mm thick laid with M-150 class brick bat coba 7.50cm thick with gap of 15mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finised smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono tythic plaster wall up to 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonany Coba with top finised plaster mixed with acetic water proofing compound @ 2% by weight & including s/o all material, labour, T& P etc complete for proper completion of work.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement. 40mm thick.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement. But floor shall be 2.5 cm thick and without base concrete
Finishing walls with water proof cement paint of approved make and quality on new work with two coat to give an even shade including supply of all materials labour ,and tools plants etc.required for proper complrtion of the work .but for each coat of water proofing cement paint after the first coats to given and even shade.
Distempering (first coat) with oil bound distemper of approved brand and manufacture & of required shade on under corated wall to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials.labour , tools ,& plants etc required for
Providing and fixing G.I. pipes fabricated cattle crush complete.
Earth work in exacavation in trenches for foundations and for (loan clay or sand)including lift upto 1.5 m and dressing of sides and ramming of bottoms and dispoposal of surplus excavated earth as directed by the Engineer i / c
Providing and laying in cementconcrete 1:4:8 (1 cement:4 coarse sand : 8 graded stone aggregate 40 mm nominal size ) and curing comp. including cost of form work in foundation and floors(PWD 281)
R.c.c. work with cement approvedcoarse sand and 2 cm. (3/4) guage approved stone ballast in the proportion of 1:2:4(1cement:6aggr)in plinth bend,lintel of doors and windows excluding necessary including supply of all materials , labour and tools and plants etc,required for proper completion of the strength of the concrete shall not be less than m-200. (PWD 283)but in R.C.C. raft foundation and footing with approved stone ballast.
R.c.c. work with cement approvedcoarse sand and 2 cm. (3/4) guage approved stone ballast in the proportion of 1:2:4(1cement:6aggr)in Raft foundation excluding necessary including supply of all materials , labour and tools and plants etc,required for proper completion of the strength of the concrete shall not be less than m-200. (PWD 283)but in R.C.C. raft foundation and footing with approved stone ballast.
R.c.c. work with cement approvedcoarse sand and 2 cm. (3/4) guage approved stone ballast in the proportion of 1:2:4(1cement:6aggr)in Coloumn excluding necessary including supply of all materials , labour and tools and plants etc,required for proper completion of the strength of the concrete shall not be less than m-200. (PWD 283)but in R.C.C. raft foundation and footing with approved stone ballast.
M-150 Sub class brick work in 1:6 cement and coarse sand of 2.26 fineness modulus mortar in foundation and plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work.
M-150 Sub class brick work in 1:3 cement and coarse sand of 2.26 fineness modulus mortar in Super structure including supply of all materials, labour, tools and plants etc. required for proper completion of the work.
M.S. ( tor steel or plain work such as R.C.C.or R.B. Work including bending for proper shape and including supply of steeel & its wastage ,bend ,hooks authorised over lapping shall be measured and including cost of building wire.
12 mm thick plaster.
Snowcem Painting. (PWD-660+661)
Painting on D.P.C.with two coats of air blown bitumen 85/50 or 85/25 @ 1.7 kg/sqm.Approx including cost of fuel if any.
Earth work in exacavation in trenches for foundations and for (loan clay or sand)including lift upto 1.5 m and dressing of sides and ramming of bottoms and dispoposal of surplus excavated earth as directed by the Engineer i / c
Providing and laying in cementconcrete 1:4:8 (1 cement:4 coarse sand : 8 graded stone aggregate 40 mm nominal size ) and curing comp. including cost of form work in foundation and floors(PWD 281)
R.c.c. work with cement approvedcoarse sand and 2 cm. (3/4) guage approved stone ballast in the proportion of 1:2:4(1cement:6aggr)in lintel of doors and windows excluding necessary including supply of all materials , labour and tools and plants etc,required for proper completion of the strength of the concrete shall not be less than m-200. (PWD 283)but in R.C.C. raft foundation and footing with approved stone ballast.
R.c.c. work with cement approvedcoarse sand and 2 cm. (3/4) guage approved stone ballast in the proportion of 1:2:4(1cement:6aggr)in Column excluding necessary including supply of all materials , labour and tools and plants etc,required for proper completion of the strength of the concrete shall not be less than m-200. (PWD 283)but in R.C.C. Coloumn with approved stone ballast. As in item 3 above but in R.C.C.
M.S. ( tor steel or plain work such as R.C.C.or R.B. Work including bending for proper shape and including supply of steeel & its wastage ,bend ,hooks authorised over lapping shall be measured and including cost of building wire.
Finishing walls with water proof cement paint of approved make and quality on new work with two coat to give an even shade including supply of all materials labour ,and tools plants etc.required for proper complrtion of the work .but for each coat of water proofing cement paint after the first coats to given and even shade.
Painting or Varnishing on iron works in small araes or new wood work with one coat over of ready mixed priming paint &one coat of approved superior mixed paint of clear synthetic enamele varnish including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work.Paint to be used shold confirm to the I.S.I. No.103 1950
S/F M.S. work in gate including all necessary for proper completion of the work.
Supply of following sizes of P. V. C. pipes fittings ( 6 kg/cm2) (a) 110 mm dia P. V. C. pipe
(b) 110 mm dia Slotted P. V. C. pipe
12 mm dia M.S. connecting Rod with Hook & Thread
Supply of 32 mm dia G.I. pipe ( Medium class).
Supply of India Mark-II Hand Pump complete with 24 m connecting rod and one number Cylinder.
Hiring of boring T & P including its carriage upto site and return back after completion of work.
150 mm dia boring by palm & pressure method in all type of strata and leveling the site after completion of work including supply of all labour etc. complete. (a) 0 to 30 M below G.L.
Preparation of PVC assembly and lowering of 110mm/60mm PVC pipe and strainer including supply of all labour, carriage upto site etc. required for proper completion of work. (a) 0 to 30 M below G.L.
Filling with coarse sand surrounding of hand pipe and below strainer and remaining base including supply of all labour, T & P, materials etc. required for proper completion of work.
Carriage of India Mark-II Hand pump, 32 mm dia G.I. Pile C/rod etc. for divisional store to site of work and its installation with G.I. Riser pipe including supply of all labour etc. complete with development of bole and its testing.
Construction of precast platform for India Mark-II Hand Pump as per departmental type design including supply of all materials, etc. required for proper completion of work.
Excavation for collection of water for boring
Water collection for pressure boring.
Provision for unsuccessful bores
Cost of B.O.E Road
Carted earth filling including watering,ramming,consolidating and dressing complete including lead up to 50 m and lift upto 1.5 m and including cost of earth
GST extra as applicable
JAY CONSTRUCTION
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .