Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC C 357 MIDC INDL AREA PAWANE THANE MAHARASHTRA 400705 | THANE | MAHARASHTRA | 400705 | ₹6.2 L | L1 | Accepted-AOC OVERALL L1 |
| 2 | L2₹7.9 L+₹1.7 L (27.8%)Rejected-Finance | ₹7.9 L+₹1.7 L (27.8%) | L2 | Rejected-Finance NOT L1 |
| 3 | L3₹8.5 L+₹2.4 L (38.4%)Rejected-Finance | ₹8.5 L+₹2.4 L (38.4%) | L3 | Rejected-Finance NOT L1 |
| 4 | L4₹11.8 L+₹5.7 L (91.7%)Rejected-Finance | ₹11.8 L+₹5.7 L (91.7%) | L4 | Rejected-Finance NOT L1 |
| 5 | L5₹13.2 L+₹7.1 L (114.5%)Rejected-Finance 301 AKASHGANGA NR GUJARAT COLLAGE ELLISBRIDGE AHMEDABAD GUJARAT 380006 | AHMADABAD | GUJARAT | 380006 | ₹13.2 L+₹7.1 L (114.5%) | L5 | Rejected-Finance NOT L1 |
Tender Value
Refer Docs
Closing Date
30 Oct 2020, 11:00 amClosed
RAJENDRA KELKAR
RCF LTD ADMIN BLDG PURCHASE DEPT CHEMBUR
NOTICE INVITING TENDER FOR SUPPLY OF PTFE LINED PIPES AND FITTING FOR SAP PLANT
2020_RCFL_591094_1
E229201008
Open Tender
Miscellaneous Goods
Supply
90 days
RCF LTD CHEMBUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
Exempted
2 Apr 2021
16 Oct 2020
30 Oct 2020
16 Oct 2020
30 Oct 2020
16 Oct 2020
SUPPLY MATERIAL AT RCF TROMBAY UNIT(AS PER TECHNICAL SPECIFICATIONS ANNEXURE-III)
SAP- PIPE (PTFE LINED) SIZE: 8" (200 NB) END CONNECTIONS: FLANGED, FLAT FACED. FIXED FLANGE ON ONE SIDE & SWIVEL (LOOSE) FLANGE ON OTHER SIDE PIPE:ASTM A-106 GR B SCH 40 PIPE LENGTH FACE TO FACE = 1250 MM FLANGE MATERIAL: ASTM- A 105 FLANGE DIMENSIONS: AS PER ANSI B 16.5/ASA 150. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95 LINING THICKNESS: 3 MM MINIMUM. PTFE/ PFA: ASTM D -1457 TYPE III/ II. TESTS : SPARK TEST @ 15 KV AND HYDROTEST@ 10 KG/CM2 PAINTING : EXTERNAL SUFACES SHALL BE EPOXY PAINTED WITH PRIMER OF 40 MICRON DFT FOLLOWED BY FINISH PAINT(COLOUR-DARK VIOLET) OF 40 MICRON DFT NOTE: 1) VENDOR SHALL SUBMIT TEST REPORTS/ CERTIFICATES (HYDROSTATIC, ELECTROSTATIC TEST, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES) ALONG WITH THE SUPPLY. 2) PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING.
PIPE 8IN DIA PTFE LINED. FLANGE TO FLANGE DISTANCE AFTER LINING 1000 MM PIPE MATERIAL: ASTM A 106 GR.B SCH 40. FLANGE MATERIAL: AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. ONE SIDE FIX & OTHER SIDE LOOSE FLANGE. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95. LINING THICKNESS: 3 MM MINIMUM. FITTING : ASTM A234 WPB. PTFE/ PFA : ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST & 10 KG/CM2 HYDROTEST
SAP- PIPE (PTFE LINED) SIZE: 8" (200 NB) END CONNECTIONS: FLANGED, FLAT FACED. FIXED FLANGE ON ONE SIDE & SWIVEL (LOOSE) FLANGE ON OTHER SIDE PIPE:ASTM A-106 GR B SCH 40 PIPE LENGTH FACE TO FACE = 700 MM FLANGE MATERIAL: ASTM- A 105 FLANGE DIMENSIONS: AS PER ANSI B 16.5/ASA 150. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95 LINING THICKNESS: 3 MM MINIMUM. PTFE/ PFA: ASTM D -1457 TYPE III. TESTS : SPARK TEST @ 15 KV AND HYDROTEST@ 10 KG/CM2 PAINTING : EXTERNAL SUFACES SHALL BE EPOXY PAINTED WITH PRIMER OF 40 MICRON DFT FOLLOWED BY FINISH PAINT(COLOUR-DARK VIOLET) OF 40 MICRON DFT NOTE: 1) VENDOR SHALL SUBMIT TEST REPORTS/ CERTIFICATES (HYDROSTATIC, ELECTROSTATIC TEST, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES) ALONG WITH THE SUPPLY. 2) PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING.
SAP- PIPE (PTFE LINED) SIZE: 8" (200 NB) END CONNECTIONS: FLANGED, FLAT FACED. FIXED FLANGE ON ONE SIDE & SWIVEL (LOOSE) FLANGE ON OTHER SIDE PIPE:ASTM A-106 GR B SCH 40 PIPE LENGTH FACE TO FACE = 350 MM FLANGE MATERIAL: ASTM- A 105 FLANGE DIMENSIONS: AS PER ANSI B 16.5/ASA 150. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95 LINING THICKNESS: 3 MM MINIMUM. PTFE/ PFA: ASTM D -1457 TYPE III. TESTS : SPARK TEST @ 15 KV AND HYDROTEST@ 10 KG/CM2 PAINTING : EXTERNAL SUFACES SHALL BE EPOXY PAINTED WITH PRIMER OF 40 MICRON DFT FOLLOWED BY FINISH PAINT(COLOUR-DARK VIOLET) OF 40 MICRON DFT NOTE: 1) VENDOR SHALL SUBMIT TEST REPORTS/ CERTIFICATES (HYDROSTATIC, ELECTROSTATIC TEST, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES) ALONG WITH THE SUPPLY. 2) PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING.
SAP- PIPE (PTFE LINED) SIZE: 8" (200 NB) END CONNECTIONS: FLANGED, FLAT FACED. FIXED FLANGE ON ONE SIDE & SWIVEL (LOOSE) FLANGE ON OTHER SIDE PIPE:ASTM A-106 GR B SCH 40 PIPE LENGTH FACE TO FACE = 450 MM FLANGE MATERIAL: ASTM- A 105 FLANGE DIMENSIONS: AS PER ANSI B 16.5/ASA 150. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95 LINING THICKNESS: 3 MM MINIMUM. PTFE/ PFA: ASTM D -1457 TYPE III. TESTS : SPARK TEST @ 15 KV AND HYDROTEST@ 10 KG/CM2 PAINTING : EXTERNAL SUFACES SHALL BE EPOXY PAINTED WITH PRIMER OF 40 MICRON DFT FOLLOWED BY FINISH PAINT(COLOUR-DARK VIOLET) OF 40 MICRON DFT NOTE: 1) VENDOR SHALL SUBMIT TEST REPORTS/ CERTIFICATES (HYDROSTATIC, ELECTROSTATIC TEST, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES) ALONG WITH THE SUPPLY. 2) PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING.
PFA LINED M.S. CONCENTRIC REDUCER. SIZE : 8X6 IN FLANGE TO FLANGE DISTANCE AFTER LINING 280 MM FLANGE MATERIAL: AS PER ASTM A 105 DIMENSIONS TO ANSI B 165/ASA 150. LINING: PFA LINING AS PER ASTM F- 1545-95. LINING THICKNESS: 3 MM MINIMUM. FITTING: ASTM A234 WPB. PFA: ASTM D -1457 TYPE III. TESTS : 15 KV SPARK TEST & 10 KG/CM2 HYDROTEST
M.S. TEFLON LINED CONCENTRIC REDUCER. SIZE: 6X4 IN FLANGE TO FLANGE DISANCE AFTER LINING 230 MM FLANGE MATERIAL: AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95.LINING THICKNESS: 3 MM MINIMUM. FITTING : ASTM A234 WPB. PTFE/ PFA : ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST& 10 KG/CM2 HYDROTEST
M.S. TEFLON LINED CONCENTRIC REDUCER. SIZE: 4X3 IN FLANGE TO FLANGE DISANCE AFTER LINING 180 MM FLANGE MATERIAL: AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95.LINING THICKNESS: 3 MM MINIMUM. FITTING : ASTM A234 WPB. PTFE/ PFA : ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST& 10 KG/CM2 HYDROTEST
TEE EQUAL 6 X6 X3 IN PFA LINED (PERFLUORO ALKOXY) WITH FLAT FACED FIXED FNGES. FLANGE TO FLANGE DISTANCE FOR 6IN FLANGES AFTER LINING 406 MM. FLNGE MATERIAL: AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95.LINING THICKNESS: 3 MM MINIMUM. FITTING : ASTM A234 WPB. PTFE/ PFA : ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST& 10 KG/CM2 HYDROTEST
SAP- CONCENTRIC REDUCER (PTFE LINED) SIZE: 6" x 3" DIA, END CONNECTIONS: FLANGED, FLAT FACED. FIXED FLANGE ON ONE SIDE & SWIVEL (LOOSE) FLANGE ON OTHER SIDE REDUCER: ASTM A234 WPB REDUCER DIMENSIONS: AS PER ANSI B16.9 FLANGE MATERIAL: ASTM- A 105 FLANGE DIMENSIONS: AS PER ANSI B 16.5/ASA 150. FACE TO FACE : 230 MM LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95 LINING THICKNESS: 3 MM MINIMUM. PTFE/ PFA: ASTM D -1457 TYPE III. TESTS : SPARK TEST @ 15 KV AND HYDROTEST@ 10 KG/CM2 PAINTING : EXTERNAL SUFACES SHALL BE EPOXY PAINTED WITH PRIMER OF 40 MICRON DFT FOLLOWED BY FINISH PAINT(COLOUR-DARK VIOLET) OF 40 MICRON DFT NOTE: 1) VENDOR SHALL SUBMIT TEST REPORTS/ CERTIFICATES (HYDROSTATIC, ELECTROSTATIC TEST, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES) ALONG WITH THE SUPPLY. 2) PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING.
SUPER INDUSTRIAL LINING PVT LTD
Agarwal Tanks and Allied Works
PH1 INDUSTRIES PVT LTD
SARASONS ENGINEERING INDUSTRIES
Amit Engineering Systems
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .