Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical 16 IKP EDEN BHUVANAPPA LAYOUT TAVAREKERE MAIN ROAD KAVERI LAYOUT S G PALYA TAVAREKERE BANGALORE BANGALORE KARNATAKA 560029 | BENGALURU URBAN | KARNATAKA | 560029 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical 7 17 BALAKRISHNAPURAM 2ND STREET ADAMBAKKAM KANCHIPURAM TAMIL NADU 600088 | CHENNAI | TAMIL NADU | 600088 | Admitted-Fee/PreQual/Technical |
Tender Value
Refer Docs
EMD Value
₹21,000
Closing Date
11 Sept 2026, 3:00 pmClosed
The Registrar
Bharathiar University, Coimbatore
Equipment
2026_HE_698564_1
C7/CRTD/Biotech/CMRG/2283
Open Tender
Electrical Goods/Equipments
Supply
Bharathiar University
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹21,000
Yes
12 Sept 2026
27 Aug 2026
12 Sept 2026
27 Aug 2026
11 Sept 2026
27 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 13D Bioprinter | |||||
| 1.01 | 1. General Requirements
i. The printer must consist of two printhead slots.,ii. Two printheads compatible with 3D printing bioinks (biomaterials and cells) must be supplied with the instrument.iii. The system must support attachment of various volumes of temperature-controlled printheads.
2. Printhead Specifications
System should Support the Following Print-Heads
I. Pneumatic Temperature-Controlled Printhead (3CC),1) Syringe Volume Compatibility: 3CC
2) Temperature Range: Room Temperature (RT) to 60˚C,3) Temperature Precision: ±0.5˚C or better
4) In-built UV and visible light photo-crosslinking modules
II. Pneumatic Temperature-Controlled Printhead (5CC),1) Syringe Volume Compatibility: 5CC
2) Temperature Range: RT to 60˚C,3) Temperature Precision: ±0.5˚C or better
4) In-built UV and visible light photo-crosslinking modules
III. Upgrade Option: User must be able to upgrade to 10CC syringe configurations. OEM shall provide proof of prior installations.
IV. High Temperature FDM Printhead,1) Compatible with thermoplastics and equivalent materials
2) Temperature Range: RT to 250˚C or higher,3) Interchangeable nozzles: 0.2 mm to 0.8 mm,3. Build Platform
I. X Axis: 120–130 mm or better,II. Y Axis: 50–80 mm or better,III. Z Axis: 50 mm or better
IV. Backlash control mechanisms must be included to ensure effective movement on all axes, with proof provided.
V. Layer resolution and XY resolution: <10 microns,VI. Must allow use of well plates (up to 12-well), petri dishes (20 mm and 60 mm), and glass slides.
4. Bed Specifications
I. Bed Temperature Range: RT to 80˚C,II. Precision Control: ±0.5˚C or better,5. Accessories
I. 3CC Air Syringes with tip ends and end caps – 50 units,II. 3CC Air Syringe Pneumatic Adapters – 2 units
III. Dispensing Needles (18, 20, 21, 22 Gauge) – 50 units each,IV. Dispensing Tapered Tips (18–22 Gauge) – 50 units each
6. Safety Features - I. H14 HEPA filter with germicidal UV integrated into chassis
II. Fail-safe mechanism for faulty UV exposure to ensure user safety
III. System must not have an inbuilt compressor; a separate 3L external oil-free compressor must be provided
7. Software
I. Printer must be compatible with most licensed and freely available slicing software for 3D printers and bioprinters.
II. OEM must provide licenses for such software.
III. Printer must include its own control software with at least two pre-fed designs:
1) One OEM-defined design
2) One user-defined design (provided 30 days before delivery)
IV. OEM must demonstrate ability to integrate user-defined designs into control software.
8. Compliance
I. Manufacturer must comply with ISO 9001:2015 certification.
9. Warranty & Maintenance
I. Warranty: Minimum of 24 months comprehensive warranty covering all parts, labor, and service.
II. Preventive Maintenance: OEM must provide at least two preventive maintenance visits per year during the warranty period.
III. Service Support:
1) OEM must ensure availability of spare parts and for at least 10 years post-installation.
2) Response time for service requests must not exceed 72 hours.
IV. Training: OEM shall provide on-site training for operators and technical staff at the time of installation.
V. Extended Warranty: Option for extended warranty and annual maintenance contract (AMC) must be offered. | 1 | No | 100 | ₹100 |
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 11.59 MB
BOQ_839674.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .