Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69.2 LAdmitted-Finance GALI NO 4 HOUSE NO 118 126116 2023R14297 | JIND | HARYANA | 126116 | L1 | Admitted-Finance | |
| 2 | L2₹72.1 L+₹3.0 L (4.26%)Admitted-Finance 392 2 VPO BASAI GURUGRAM 122001 | GURUGRAM | GURUGRAM | HARYANA | 122001 | L2 | Admitted-Finance | |
| 3 | Not Admitted-Fee/PreQual/Technical 12 SF H NO 12 SF SECTOR 57 GURGAON 122003 | GURGAON | GURGAON | HARYANA | 122003 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | THE GREEN HOMES CO-OPERATIVE LABOUR & CONSTRUCTION SOCIETY LIMITED L2 | The mahakal Co-OP L&C society LTD L1 |
|---|---|---|---|---|---|
| 1.00 | Providing and fixing SFRC Single Road Gully cover and frame of size 600mmx450mm | 20 | Each | 810 ₹16,200 | 700 ₹14,000 Lowest |
| 2.00 | Making rough surface of finishing surface | 1,900 | Sqm | 20 ₹38,000 | 15 ₹28,500 Lowest |
| 3.00 | Cutting of contracton /transverse/ longitudinal joints 8mm
widthand 1/3 depth of cc pavement and filling the same with
bitumen filler. | 400 | Metre | 50 ₹20,000 | 45 ₹18,000 Lowest |
| 4.00 | Supply and filling (good earth/tibba sand) including
watering, compaction, royality/compensation of earth
complete upto lead of 19 km asp er HSR (N.S) | 250 | cum | 700 ₹1,75,000 | 620 ₹1,55,000 Lowest |
| 5.00 | Repair of damaged household Sewer connection existing line (Including GST) | 25 | Each | 500 ₹12,500 | 300 ₹7,500 Lowest |
| 6.00 | Repair of damaged household Water Supply connection existing line (Including GST) | 25 | Each | 500 ₹12,500 | 300 ₹7,500 Lowest |
| 7.00 | i. Weld Mesh Panels manufactured with electrical resistance welded galvanized wires and
subsequently powder coated as per specifications mentioned under.
ii. Weld mesh panel for fence will meet the standards of IS 1566/ IS 4849 with the following
key specifications apart from the other points in the governing specification:
iii. Panel size: 2500 mm X 1500 mm (W x H). Tolerance of plus / - 2 %
iv. Mesh Size: 50 mm X 150 mm (W X H). Tolerance of plus / - 2 mm.
v. Weld Shear strength: Minimum 50 % of the breaking strength of the smallest wire (In
this case the vertical wire)
vi. Mesh Wire: Galvanized MS wire
Horizontal wire, Dia. 5.0 mm ( plus /- 0.05mm): Vertical wire, Dia. 5.0 mm( plus /-0.05mm)
Tensile Strength of wire: Min 500 N/sq.mm: Specification for wire: IS 280
vii. Galvanizing of wire: 100 – 120 GSM as per IS 4826 (Measurement as per IS 6745)
Uniformity of Coating: As per IS 2633: Adhesion test for coating: As per IS 2629 (1985)
viii. Powder Coating: The galvanized panels are subsequently single powder coated after
welding with a thickness of 60 to 80 microns.
ix. Powder Coating Make : Akzonoble / Jotun.
x. Color: RAL 6005 (Military Green): Coating Standard: EN 10245-1/ IS 13871
xi. Other coating requirement: Powder coating should withstand 720 Hours of salt spray test
as per ISO 12944, 1000 hrs of QUV-B Weatherometer Test, Adhesion test,
Electrochemical Impedance Spectroscopy Test (Type Test Certificate for the coating | 380 | Metre | 1,500 ₹5,70,000 | 1,300 ₹4,94,000 Lowest |
Tender Value
₹65.7 L
EMD Value
₹1.3 L
Closing Date
2 Nov 2026, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Kuldeep Kumar
Municipal Corporation Gurugram
Construction of Road with RMC M40 and Construction of Footpath from 2019Sp to 2003P in Sector 45, Ward 24 under EE 4B MCG.
2026_HRY_556008_1
2026AA804CBC CF57 4AC4 935B 3E5BF562F7A4285ULB
Open Tender
Civil Works
Works
200 days
Gurugram
2 documents required · 2 mandatory
₹5,000
₹1.3 L
Yes
19 Nov 2026
23 Oct 2026
2 Nov 2026
23 Oct 2026
2 Nov 2026
23 Oct 2026
180 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing and fixing SFRC Single Road Gully cover and frame of size 600mmx450mm | 20 | Each | - | - |
| 2 | Making rough surface of finishing surface | 1,900 | Sqm | - | - |
| 3 | Cutting of contracton /transverse/ longitudinal joints 8mm
widthand 1/3 depth of cc pavement and filling the same with
bitumen filler. | 400 | Metre | - | - |
| 4 | Supply and filling (good earth/tibba sand) including
watering, compaction, royality/compensation of earth
complete upto lead of 19 km asp er HSR (N.S) | 250 | cum | - | - |
| 5 | Repair of damaged household Sewer connection existing line (Including GST) | 25 | Each | - | - |
| 6 | Repair of damaged household Water Supply connection existing line (Including GST) | 25 | Each | - | - |
| 7 | i. Weld Mesh Panels manufactured with electrical resistance welded galvanized wires and
subsequently powder coated as per specifications mentioned under.
ii. Weld mesh panel for fence will meet the standards of IS 1566/ IS 4849 with the following
key specifications apart from the other points in the governing specification:
iii. Panel size: 2500 mm X 1500 mm (W x H). Tolerance of plus / - 2 %
iv. Mesh Size: 50 mm X 150 mm (W X H). Tolerance of plus / - 2 mm.
v. Weld Shear strength: Minimum 50 % of the breaking strength of the smallest wire (In
this case the vertical wire)
vi. Mesh Wire: Galvanized MS wire
Horizontal wire, Dia. 5.0 mm ( plus /- 0.05mm): Vertical wire, Dia. 5.0 mm( plus /-0.05mm)
Tensile Strength of wire: Min 500 N/sq.mm: Specification for wire: IS 280
vii. Galvanizing of wire: 100 – 120 GSM as per IS 4826 (Measurement as per IS 6745)
Uniformity of Coating: As per IS 2633: Adhesion test for coating: As per IS 2629 (1985)
viii. Powder Coating: The galvanized panels are subsequently single powder coated after
welding with a thickness of 60 to 80 microns.
ix. Powder Coating Make : Akzonoble / Jotun.
x. Color: RAL 6005 (Military Green): Coating Standard: EN 10245-1/ IS 13871
xi. Other coating requirement: Powder coating should withstand 720 Hours of salt spray test
as per ISO 12944, 1000 hrs of QUV-B Weatherometer Test, Adhesion test,
Electrochemical Impedance Spectroscopy Test (Type Test Certificate for the coating | 380 | Metre | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
BOQ_635951.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .