Loading…
Loading…
Tender Value
₹27.8 L
EMD Value
₹55,558
Closing Date
8 Jul 2026, 3:00 pm
Similar tender results from the same govt authority in the past 3 years.
Executive Engineer(Elect.)
Seed Bed Park School Block DDA Complex Shakarpur Delhi-92
Running Maintenance and Operation of fire fighting system, fire alarm system, clear water pump set, sub p/set, EI and Fans at DDA building Laxmi Nagar Dist. Centre.
2026_DDA_915159_1
15/EE/ELD-1/DDA/NIT/2026-27
Open Tender
Electrical Works
365 days
As per NIT
Please refer Tender documents.
14 documents required · 14 mandatory
₹0
₹55,558
In the chamber of EE(E)/ELD-1/DDA
30 Jun 2026
30 Jun 2026
9 Jul 2026
30 Jun 2026
8 Jul 2026
2 Jul 2026
1 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | 1.0) Running, maintenance & operation of various E&M services at DDA building Laxmi Nagar Distt. Centre. By deploying following manpower:-
(i) Operator Gr.II cum technician round the clock -3 Nos. on daily basis.
(ii) Lift Operator Gr. II -2 Nos.on daily basis.
(iii) Khallasi 1 No.on daily basis. | 12 | P/Month | 1,91,123 | ₹22,93,476 |
| 2 | 2.0) Servicing of DG Set 160 KVA (kirloskar make) including labour charges for complete servicing and testing i/c commissioning etc complete as reqd replacement/ repair/calibration of following, Diesel and oil filter, Air cleaner electrical, Coolant, Hose pipe set with clamp, Engine self repairing and servicing i/c replacement of part, Fuel pump repair and calibration, Engine oil. | 1 | Job | 27,679 | ₹27,679 |
| 3 | 3.0) LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).
Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
3.01) 18- 22 Watt | 60 | Each | 681 | ₹40,860 |
| 4 | 4.0) Supply and replacement of fan regulator switch in the existing electric board i/c connection, testing etc. as required. | 10 | Each | 207 | ₹2,070 |
| 5 | 5.0) Supply and replacement of cooler pump 230 Volt, AC supply having 12.0 watt consumption with maximum water filled with lift 1.5 mtr. Immersion depth 200 mm connection, testing etc. as required. | 10 | Nos | 317 | ₹3,170 |
| 6 | 6.0) Supply & replacement of desert coolers pads of wool with mesh wire (3 Nos.) suitable for 18"/20" desert cooler i/c removal of old, cleaning of dust after removing cooler from the window and reinstallation of the same at window etc. Complete as required.
6.1) Wood wool pad with wire mesh.- 3 Nos. | 10 | Each | 238 | ₹2,380 |
| 7 | 7.0) Supply & replacement of cooler kit (Fan size 18"/20" i/c blade, motor) connection, testing, and commissioning etc. as reqd. | 5 | Each | 1,109 | ₹5,545 |
| 8 | 8.0) Supplying and replacement round copper cable lead of size 40/76 mm three core of 3 Mtrs. long i/c providing/ fixing 3 pin 15 Amp top plug etc. complete as required. | 10 | Nos | 103 | ₹1,030 |
| 9 | 9.0) Rewinding of 48" ceiling fan oiling, greasing servicing, cleaning dismantling and re- assembling along with testing, commissioning etc. as required. | 10 | Nos | 452 | ₹4,520 |
| 10 | 10.0) Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.. | - | - | - | - |