Loading
Loading…
Loading…
Tender Value
₹5 L
EMD Value
₹5,000
Closing Date
6 Jul 2026, 3:00 pm
Similar tender results from the same govt authority in the past 3 years.
Commissioner Surandai Municipality
Commissioner Surandai Municipality
Surandai Municipality Maintenance of Toilet at Bus Stand
2026_MAWS_682372_1
820/2026/E1
Open Tender
Civil Works
360 days
Surandai
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹5,000
23 Jun 2026
23 Jun 2026
6 Jul 2026
23 Jun 2026
6 Jul 2026
23 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Oriya Type Indian Water Closet 580mm x 440mm with P or S Trap Colour | 5 | 1No (One Number) | 1,534 | ₹7,670 | BI01010001010000000000000515BI0100001113 |
| 2 | Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 over a cement mortar bed of 20mm thick in Cement Mortar 1:3 (One Cement and Three crushed stone sand) with required Cement Slurry and Mortar Plasticizer and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) | 15 | 1Sqm (One Square Meter) | 1,492.85 | ₹22,392.75 | BI01010001010000000000000515BI0100001114 |
| 3 | European Water Closet with P or S Trap with Double Flapped Seat and Seat Cover with Brass Hinges and 10 litre capacity PVC Low Level Flusing Tank with all internal fittings Colour | 5 | 1No (One Number) | 3,484 | ₹17,420 | BI01010001010000000000000515BI0100001115 |
| 4 | Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC.unsheathed Cu. Conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A F.T. switch with painting of suitable Colourfor open PVC light point / fan point (For electronic regulator) (5 points per coil)SD 18 | 5 | 1No (One Number) | 1,188 | ₹5,940 | BI01010001010000000000000515BI0100001116 |
| 5 | Supply and fixing of 4'40 W twin street light flu. fitting complete With copper choke and condensor with 19mm dia GI pipe (Class 'B') with 1 No. 19mm GI Bend complete on the existing post / wall With 16 A aerial fuse unit on MS plate with PVC unsheathed Cu. leads, with MS clarnps and aluminium painting with Flu. Tubes.SD 94 | 5 | 1No (One Number) | 907 | ₹4,535 | BI01010001010000000000000515BI0100001117 |
| 6 | Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. | 72 | 1No (One Number) | 107.85 | ₹7,765.2 | BI01010001010000000000000515BI0100001118 |
| 7 | Supply and fixing of WT bulk head fitting with guard (Philips/Bajaj/Crompton/K-Lite) suitable for 11W CFL lamp with CFL SD 83 | 4 | 1No (One Number) | 549 | ₹2,196 | BI01010001010000000000000515BI0100001119 |
| 8 | Painting Old Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) | 400 | 1Sqm (One Square Meter) | 180.55 | ₹72,220 | BI01010001010000000000000515BI0100001120 |
| 9 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. | 13.5 | 1Sqm (One Square Meter) | 8,313 | ₹1,12,225.5 | BI01010001010000000000000515BI0100001121 |
| 10 | Painting Old iron work with two finishing coats of ready mixed synthetic enamal paint over one coat of ready mixed primer of approved quality etc., complete as per standard specification. | 5.5 | 1Sqm (One Square Meter) | 67.83 | ₹373.07 | BI01010001010000000000000515BI0100001122 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
BOQ_820188.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid