Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC | ₹8.8 L | L1 | Accepted-AOC beingL1 |
| 2 | L2₹9.8 L+₹97,290 (11.1%)Rejected-Finance | ₹9.8 L+₹97,290 (11.1%) | L2 | Rejected-Finance quoted amount is higher than 1st lowest |
| 3 | L3₹11.1 L+₹2.3 L (26.4%)Rejected-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | ₹11.1 L+₹2.3 L (26.4%) | L3 | Rejected-Finance quoted amount is higher than 1st lowest |
| 4 | L4₹11.3 L+₹2.5 L (28.6%)Rejected-Finance NO 12 25 26 KATHIRAVAN NAGAR MAHALINGAPURAM PO POLLACHI COIMBATORE 642 002 | COIMBATORE | TAMIL NADU | 642002 | ₹11.3 L+₹2.5 L (28.6%) | L4 | Rejected-Finance quoted amount is higher than 1st lowest |
Tender Value
₹8.9 L
EMD Value
₹17,800
Closing Date
29 Sept 2022, 6:00 pmClosed
AGE I AF Coimbatore
AGE I AF COIMBATORE AFAC COMPLEX KAMARAJAR ROAD RED FIELD POST COIMBATORE PIN -641018
SPECIAL REPAIRS TO SPLIT TYPE AIR CONDITIONERS AND VOLTAGE STABILIZERS AGAINST BER AT AFAC COIMBATORE
2022_MES_541789_2
8878_E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
COIMBATORE
Class-E category-b(i) (see NIT for detail)
6 documents required · 6 mandatory
₹500
AGE I AF Coimbatore
₹17,800
Yes
29 Oct 2022
5 Sept 2022
1 Oct 2022
5 Sept 2022
29 Sept 2022
15 Sept 2022
5 Sept 2022 - 19 Sept 2022
Amount
Supply, install, testing and commissioning of Split type Air conditioner both indoor and outdoor units with remote control unit complete provided with anti dust filter for better indoor air quality, minimum 3 star rating , electric driven Single phase of capacity of 1.5 TR alongwith one set of mounting brackets of suitable size to mount the outdoor unit, boring hole in any type of wall upto 4'' dia, providing and inserting suitable size PVC sleeve in the wall, connecting the discharge and suction copper pipes including necessary insulation, clading etc complete all as specified and as directed by Engr-in-charge. Make:- Voltas/ Blue star/ Daikin / LG
Supply, install, testing and commissioning of Split type Air conditioner both indoor and outdoor units with remote control unit complete provided with anti dust filter for better indoor air quality, minimum 3 star rating electric driven single phase of capacity of 2 TR alongwith one set of mounting brackets of suitable size to mount the outdoor unit, boring hole in any type of wall upto 4'' dia, providing and inserting suitable size PVC sleeve in the wall, connecting the discharge and suction copper pipes including necessary insulation, clading etc complete all as specified and as directed by Engr-in-charge. Make:- Voltas/ Blue star/ Daikin / LG
Supply, install, testing and commissioning of Split type Air conditioner both indoor and outdoor units with remote control unit complete provided with anti dust filter for better indoor air quality, minimum 3 star rating , electric driven three phase of capacity of 3 TR alongwith one set of mounting brackets of suitable size to mount the outdoor unit, boring hole in any type of wall upto 4'' dia, providing and inserting suitable size PVC sleeve in the wall, connecting the discharge and suction copper pipes including necessary insulation, clading etc complete all as specified and as directed by Engr-in-charge. Make: Blue star, Cat No. FMA36AAMUP3 or equivalent in Samsung, Hitachi.
Note : Item No 1 to 3 - (a) The quoted rates shall be deemed to be inclusive of copper tubbings upto additional 5 RM each for both suction and discharge. (b) Taking down the unserviceable unit in any position/situation and deposited the same at AGE (EM) Store yard .
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amp all as specified. Make - Indoasian / Havells / Standard
Supply and fix Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 32 amps 415 volts all as specified. Make - Indoasian / Havells / Standard
Sub main wiring complete with 2 runs of 4 Sqm single core PVC insulated FR cable 1100 volts grade multistranded copper conductor cable with 1 run of 4 Sqm single core PVC insulated FR cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories concealed in wall/Ceiling etc all as specified and as directed by Engr - in- charge. Note : 2 runs of 4 Sqmm cable, 1 run of 4 Sqm earth conductor and 1 run of PVC conduit shall be measured as one unit length
Sub main wiring complete with 4 runs of 4 Sqm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 2 run of 4 Sqm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories concealed in wall/Ceiling etc all as specified and as directed by Engr - in- charge. Note : 4 runs of 4 Sqm cable, 2 run of 4 Sqmm cable for earth conductor and 1 run of PVC conduit shall be measured as one unit length
Supply and fix Wall mounted Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 285 V with output voltage stabilized at 230 V with accuracy of ± 2.5% ,automatic reset, LED display, and of capacity 5 KVA. Make: V-Guard Model No. VND500 or equivalent in Blue Bird.
V.R.Enterprises
KRISHNA ENTERPRISES
Rajapriyaconstruction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .