| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹23.3 LAdmitted-Finance A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | -18.33% | ₹23.3 L | L1 | Admitted-Finance |
| 2 | L2₹24.0 LAdmitted-Finance | -16.11% | ₹24.0 L | L2 | Admitted-Finance |
| 3 | L3₹24.7 LAdmitted-Finance 0 0 0 ABABAKPUR KANPUR NAGAR UTTAR PRADESH 209203 UDYAM UP 43 0068644 | KANPUR NAGAR | UTTAR PRADESH | 209203 | -13.50% | ₹24.7 L | L3 | Admitted-Finance |
Tender Value
₹28.6 L
EMD Value
₹60,000
Closing Date
13 Apr 2026, 1:00 pmClosed
Executive Engineer (Elect)/KBZ
OFFICE OF THE EX. ENGINEER (ELECT)-IV/KBZ TOURIST CAMP SITE, J.L. NEHRU MARG, DELHI-02
Comprehensive AMC (Annual Maintenance Contract) for repair and maintenance of Tube Wells installed at Various Municipal Parks under Karol Bagh Zone
2026_MCD_273630_1
NIT No 57/EEE/KBZ/MCD/2025-26
Open Tender
Electrical Works
365 days
Karol Bagh Zone
Please refer Tender documents.
5 documents required · 5 mandatory
₹590
₹60,000
13 Apr 2026
31 Mar 2026
13 Apr 2026
31 Mar 2026
13 Apr 2026
31 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.001 | Supply, Installation, testing and commissioning of cubical type control panel board for single phase & Three Phase submersible pumping set of following rating complete with contactor, relay , MCB ,condenser ,voltmeter, ammeter and indication lamp etc including connections etc as reqd. 1.5 HP (Single Phase) | 12 | Nos. | 4,251 | ₹51,012 |
| 2 | Supply, Installation, testing and commissioning of cubical type control panel board for single phase & Three Phase submersible pumping set of following rating complete with contactor, relay , MCB ,condenser ,voltmeter, ammeter and indication lamp etc including connections etc as reqd. 3.0 HP (Single Phase) | 6 | Nos. | 5,204 | ₹31,224 |
| 3 | Supply, Installation, testing and commissioning of cubical type control panel board for single phase & Three Phase submersible pumping set of following rating complete with contactor, relay , MCB ,condenser ,voltmeter, ammeter and indication lamp etc including connections etc as reqd. 5.0 HP (Three Phase) | 8 | Nos. | 6,630 | ₹53,040 |
| 4 | Comprehensive AMC (Annual Maintenance Contract) for repair and maintenance of Tube Wells installed at various Municipal works for depth upto 50 Meters for Cost for one tube well with submersible pump set etc. of rating up to 1/1.5 HP for one year. | 127 | E | 9,989 | ₹12,68,603 |
| 5 | Comprehensive AMC (Annual Maintenance Contract) for repair and maintenance of Tube Wells installed at various Municipal works for depth upto 50 Meters for Cost for one tube well with submersible pump set etc. of rating up to 3 HP for one year. | 58 | E | 10,993 | ₹6,37,594 |
| 6 | Comprehensive AMC (Annual Maintenance Contract) for repair and maintenance of Tube Wells installed at various Municipal works for depth upto 50 Meters for Cost for one tube well with submersible pump set etc. of rating up to 5 HP for one year. | 58 | E | 12,124 | ₹7,03,192 |
| 7 | Comprehensive AMC (Annual Maintenance Contract) for repair and maintenance of Tube Wells installed at various Municipal works for depth upto 50 Meters for Cost for one tube well with submersible pump set etc. of rating up to 7.5 HP for one year. | 4 | E | 13,810 | ₹55,240 |
| 8 | Comprehensive AMC (Annual Maintenance Contract) for repair and maintenance of Tube Wells installed at various Municipal works for depth upto 50 Meters for Cost for one tube well with submersible pump set etc. of rating up to 10 HP for one year. | 1 | E | - | - |
| 9 | Development of tube well with suitable capacity of air compressor i/c lowering of the necessary induction pipe or line i/c cost of fuel, hire charges of compressor etc as reqd. The development shall be considered complete when Gravel stop sinking, Discharge ceased to improve and the sand contents are not more than 10 PPM after 20 minutes of starting the pump complete as reqd. | 5 | Job | - | - |
stage.html
html • 0.03 MB
techsummary_319441.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
ProformaofSchedulesAMCKBZ.pdf
Tender Documents • 0.41 MB
PG.pdf
Other Document • 0.98 MB
BOQ_319441.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid