Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC NO 6 AADHI NAGAR RAJAJI CROSS STREET EAST TAMBARAM CHENNAI 600 059 | CHENNAI | CHENNAI | TAMIL NADU | 600059 | ₹1.1 Cr Quoted ₹1.2 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.2 Cr+₹3.2 L (2.73%)Rejected-Finance | ₹1.2 Cr+₹3.2 L (2.73%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹1.2 Cr+₹6.4 L (5.45%)Rejected-Finance NO 1 853 NEELANGARI LINK ROAD PRABHU NAGAR THORAIPAKKAM CHENNAI 600 097 | CHENNAI | CHENNAI | TAMIL NADU | 600097 | ₹1.2 Cr+₹6.4 L (5.45%) | L3 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹62,500
Closing Date
16 Dec 2024, 3:00 pmClosed
Superintending Engineer II
Superintending Engineer II, CW, Koyambedu, Chennai
Development of Football ground at Appasamy Street Chetpet
2024_CMDAC_506583_1
08/2024-25_06_football_Chetpet
Open Tender
Civil Works
Lump-sum
Chetpet
Registration of Contractor Certificate
Annual Turnover
Similar Work experience
GST Registration
Income Tax Return
Pan card
7 documents required · 7 mandatory
₹0
₹62,500
Yes
4 Feb 2025
3 Dec 2024
17 Dec 2024
3 Dec 2024
16 Dec 2024
11 Dec 2024
Amount
BIG LIVE T REES TRANSLOCATION WORK WITHIN 500 FEET I) BIG TREES 1.Replacing of existing trees are identified that total scope of works- trees translocation – trees follow details works description 2.Mobilization of skilled arboricultural & unskilled manpower with necessary materials and tools 3.Trees surrounding excavation & translocation proposed area should be excavation including all related works 4.Pruning of trees and removing of strums, branches cutting, providing medicine application, anti-termite, antibacterial, antifungal treatment application of phorate powder,30ml of antibacterial liquid,30ml of antifungal liquid20ml root promote (IBA Solution) as per requirement 5.Exposed roots cutting and packing with chemicals and approved materials as per requirement. Fungicide control spray for roots 6.Rooting harmonium for future white roots formation 7.Mother soil ball green net/packing material as per requirement 8.Upcoming new roots boosting medicine application. 9.New pits inside all direction’s fungicide control granules application 10.New planting crane charges
Dismantling, clearing away and carefully stacking materials etc., complete
Dismantling RCC using deploying machineries
Brick / Stone Masonry in cement mortar walls under 3m high
Conveyance of Earth/Debris to a lead of within 30 km from site as directed by the Engineer inculding loading, unloading, hire charges for vehicle and other incidental charges etc., all complete as directed by the Departmental Officers.
Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum
Supplying and filling with earth up to 20 Km. for foundation and basement,etc.,including watering and consolidating,etc.,complete 363C
Supplying and filling in foundation and basement with filling M-sand in layers of not more than 15cm.thick well rammed watered and compacted etc., complete complying with standard specification.
Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification.
Plain Cement Concrete 1:2:4 (one cement, two M Sand and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
For column footing plinth beam bed blocks templates staircase, steps piers raft beam raft slab etc.,
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc
Providing Granolithic floor finish 50mm thick with PCC 1:2:4 (One cement two M-sand and four aggregate) using 10 to 12mm thick HGB jelly and river sand and including rubbing the top surface smoothly thread lining if found necessary and curing etc., complete complying with standard specification and as directed by the Departmental officer
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 350 kglms and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
Foundation
ground floor
Supplying, fabricating and placing in position Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
Flyash Brick Work in CM 1:5 [One of Cement and Five of M-Sand) 230mm thick Using size 230x110x75mm including dewatering wherever necessary proper setting, curing etc., all complete and as directed by the departmental officers. In Cement Mortar 1:5
In Ground floor
Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 20mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.
Plastering with Cement Mortar 1:5 (One Cement and Three Plastering Sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.
Supply and fixing of M.S Grills with Drain grating with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification.
Providing and applying Painting the wall with Texture Finish Paint including labour charges the required ssize and making ornamental designs as per the site condition and as directed by the departmental officers.
Providing and applying heat reflective environmental friendly, 100% Pure Acrylic elastomeric waterproof coating on metal sheets. Replace roof fasteners, as required and needed. Sealing up of all lapping joints, gaps, flashing and capping with 2 component PMMA base waterproof Coating @3kg/m2 including metal primer @.1L/m2 and fleece at a 150mm wide strip. Preparing the surface by cleaning with a brush and removing the rust using a chloride-free chemical. Apply one coat of anti-corrosive primer at 0.15L/m² for GI/Metal surfaces and apply one coat of solvent-free, medium-viscous, epoxy primer at 0.15L/m² for powder?coated surfaces. Apply 2 coats of 100% Pure Acrylic waterproofing coating @ 0.8L/m2 having Elongation 190% as per ASTM D 412, tensile strength 1.5 N/mm2, SRI Index 108 as per ASTM E 1980-01. The finished cost to include surface preparation completely as per specification.
Designing, Providing and fixing in position Hot rolled structural steelMembers / Sections consists of MS joists, channels, angles, purlins,pipes, hollow tubes, runners, insert plates, flats etc. at all levels. Surface preparation of all MS members by Sand blasting to SA 21/2 grade and painted with anti corrosive, low VOC PU paint (metallic finish) with compatible primer to a minimum film thickness of 75 microns and 2 coats of low VOC PU paint of Akzonoble make and total dry film thickness 225 microns. (Only Main structural supports related to Facade works if required any shall be considered and no base frame or support structure shall not be considere, which shall form part of the respective cladding and Glazing items). Refer Particular Specification for Mode of measurement for this item. The rate including the cost of all materials,labour,tools,tackle and plants, wastage etc.,as per specification and drawings complete. The rate including cost of bolts, nuts, washers, welding, electrodes and connections required for the work. No extra on this account will be paid for. The rate to include preparation of fabrication shop drawings for departmental engineer-in-charge approval before commencement of work.
Providing and applying Fly Proof Mesh including labour charges the required ssize and making ornamental designs as per the site condition and as directed by the departmental officers.
Supplying and fixing colour galvalume sheet roof of 0.47mm thickand steel tubular box section of 100x50x3mm of 1meter interval including priming coat fixing in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers.
Supply and fixing 8 Chain Link - 2” x 2” using 10 Gauge Galvanised Iron Wire (of all sizes)
Supplying and laying rubberised inter locking paver block m40 grade providing and laying of 63mm thick high strength type confirming IS 15658-2006 of rubberised inter locking paver block in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with stone dust cushion below the uniform shap of approved non skitting surface in the top and the rate including levelling the base preparation of pavers as sub base, stone dust cushion 150mm thick laying out of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,.
Providing and Laying, Spreading and Compacting graded stone aggregate to Wet Mix Macadam (WMM) specification including premixing the materials with water at OMC in mechanical mix plant carriage to mixed material by tipper to site laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per clause 406 of MORTH Specifications.
Construction of INSPECTION CHAMBER following clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand] using best quality of second class Table Mould Bricks of size 9" x 43/8" x 23/4" with Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification. (CLEAR SIZE 0.90 X 0.90)
Structural Glazing: Providing and fixing structural glazing fabricated from roll formed sections made of galvanized steel colour coated (Base steel as per IS 513 of ‘D’ quality, galvanized as per IS 277 with Zinc of 120 grams / sqm.) with total coated thickness of 0.72mm. The glass holding section made of 304 grade SS of 0.6mm thick. Galvanized steel sections are to be used as stiffeners inside the colour coated steel / powder coated sections as per the design requirement. Design calculations are made to suit wind pressures as given in IS 875.Paint specifications: Primer coat with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick.Dimensions: The section should be of 37 x 53mm for frame vertical, 37 x 53mm for frame horizontal section and section for reinforcement should be of 31 x 55mm. glass holding section should be of 37 x 37mm for top and bottom grids in between should be of 37 x 18mm.\Accessories: Brackets made of CRCA powder coated / electro plated should be used to fix vertical at top and bottom and vertical to slab as per site requirement. Polyurethane brackets should be used to connect horizontal section to vertical sections.Silicone: Natural cure, with good UV resistance to be used. The above frame should be fixed to brick / concrete masonry by using nylon self–expanding cap and driving MS electro plated 80mm long screws into the caps through frames.Glass: 5mm reflective Saint Gobain OR equivalent. M-0671
Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights. The extruded section cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc. The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147. Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officer
Supply and fixing full steel chest drawer with single lockmechanism. total 12 drawers. drawer size(4'x12'x15')
SUPPLY and fixing visitor single seater fibre chair ,wherever necessary to install the benches in position and intact
Providing for flooring using PU Sports Flooring(8mm RUBBER With 2MM PU)Material with Installation.
PLUMBING ITEMS
Supplying and erecting in position of 50 liters capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact(250lts)
Providing rain water harvesting using 3 nos.of R0.45 well rings of 90cm inner dia (clear) with 5cm wall thickness made out of cement concrete 1:2:4 using 20mm hard broken jelly to a height of 30cm each supplying and fabricating 16 nos. of 6mm dia MS rod vertically and 3 nos. of 6mm dia MS rod circumferentially tied together with 18 guage binding wire for well rings including necessary earth work excavation 1m dia to a depth of 1m, supplying and filling 40mm HBG inside the erected well ring to a depth of 90cm, and top covered with R0.45 circular perforated cover slab of 1m dia and 5cm thick which inclusive of cost and fabrication of 6mm M.S reinforcement at 15 cm spacings on both directions and one 6mm M.S rod ties at the edge of the slab circumferentially including cost of moulding, curing, finishing and well placing in position and disposing off excavated earth with all initial leads and lifts in places as shown by the Departmneal officers etc., complete in all respects.
Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works.
ELECTRICAL ARRANGEMENTS
100A LT Metering Panel - Supply, Installation, Testing and Commissioning of CPRI approved make of panel, cubicle type, Free standing, Wall mounted, single front, 14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars, internal wiring, colour coding, ferrules, Panel mounting MS Channels, fasteners, etc., including all associated control wiring. The Breaker of 100A TPN MCCB and 1set of 100/5A CT with TNEB Metering provision and 1nos of 100/5A CT for APFCR .
Supply and fixng of TNEB meter board suitable for 3 phase 63A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 63A fuse units (500V), 1 No. neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with 1 No 63 Amp 30 MA Four Pole RCD / RCCB (Higher End) with suitable necessary connection with earth connection complete.
Supply and fixing of 4 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board ( with MCCB Incomer ) with double door (metal door ) with 1 no. 250 A 4 P MCCB switch as incoming and 3 nos.63A 3P MCB , 3 nos. 6A -32A SP MCB as outgoing with suitable cable end box on wall with earth connection only. Higher End I.250 A 4P MCCB SWITCH-1 NO II.63 A 3P MCB -3 NOS III.6A-32SP MCB SWITCH -3 NOS
supply and fixing TPMCB DB with Metal Door Cover with IP 42 Protection HIGHER END 4 ways 3 phase DB No. of ways incomer MCB / Isolator - 4 No. of ways incomer ELCB / RCD - 4 No. of outgoings ways - 12
Supply and fixing of 7 segment 4 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 4 ways in each segment) and seperate provision for MCB / Isolators ( totally 12 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following on wall with earth connection only. 63A 4P MCB - 1 no. ii.63A DP MCB Isolator -3 nos. iii.6A to 32A SP MCB - 12 nos.
Supply and fixing of horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure double door (metal) with 40A 4 pole MCB isolater as incoming and 12 Nos. 6A to 32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark (like standard make).
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 8 nos. 6A to 32A SP MCB as outgoing concealed on wall with earth connection only. Higher End.
Supply and Laying of 3 1/2C x 70 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and fixing of brass cable gland for 3 1/2 C x 70 Sq.mm PVC LTUG armoured cable with earth connection.
Supply and providing cable end termination of 3 1/2 Core x 70 Sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete.
Supply and Laying of 3 1/2C x 35 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and fixing of brass cable gland for 3-1/2C x 35 sq.mm. PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3-1/2C x 35sq.mm.PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.
Supply and Laying of 4C x 16 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and fixing of brass cable gland for 4 x 25 sq.mm. LTUG armoured cable with earth connection.
Supply and providing cable end termination of 3-1/2 X 25 sq.mm. PVC LTUGaluminiumarmoured cablewith necessary aluminium cable sockets by crimping etc with electrical connection complete.
Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour.
Supply and Run of 2 Run x 2.5 sqmm and 1R of 1.5sq sqmm PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable Pvc conduit pipe on concealed wall and ceiling with continuous earth wire connection with painting of suitable colour.
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe Concealed in wall and ceiling with MS accessories with suitable Module GI switch box in flush wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with painting of Suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for Concealed MS conduit Plug point ( 8 points / Coil) Higher End 5A Socket.
Wiring with 2 x4 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories with suitable Module GI switch box in flush with wall with 1 no. 16A one way module switch and 1 no. 16A/6A 3 pin module socket with module front plate with painting of Suitable colour with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for Concealed MS conduit 15A Plug point ( 8 points / Coil) Higher End 15A Socket.
Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor cable of 1100V grade in suitableheavy cauge MS conduit pipe concealed in wall and ceiling with MS accessories inflush with wall with suitable MS box tothe house control switch and regulator with 3rnm thick hylum sheet cover for MS switch box with continuous earth wireconnection of 1.5 sq.mm copper wire and rnaking good of the concealed portion with suitable colour for concealed fan point (for rheostatic type fan regulator).
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS FRLS copper conductor of 1100 V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories with Module GI switch box in flush wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire forand making good of the concealed portion with painting of suitable colour for conceale MS conduit Light point / fan point (for electronic regulator) (6 points / Coil) Higher End.
Supply and fixing of 80W LED Focus Light Fitting with LED with PVC unsheathed copper leads from terminals to the fitting. The rate also includes necessary clamps, screws etc. The rate also includes laboour charges etc.complete.
supply and fixing of 25W SPIRAL B22 CFL light fitting with LED Post top lantern fitting with SC holder suitable Fittings.
supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
supply and fixing of 1200mm (48") sweep AC ceiling fan 5 star rated complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18").
Supply and fixing of ms door, Labour wrought and put up in position Shutters for fully panelled doors (external or internal) moulded panels including labour charges for fixing furniture fittings complying with standard drawings and standard specification
Supply and Fixing of Water Tight Bulk Head Fitting suitable for 100 / 60 Watts Lamp with Guard Heavy Type.
Supply and fixing of HDPE pipe of 120mm dia for all services cable.
CCTV CAMERA ARRANGEMENTS
Supply, Installation, Testing and commissioning of 16channel 8 SATA NVR, with 6T Hard Disk Drive 4 nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected, Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output HDMI1 / VGA1 outputs provided HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback.and smart playback to improve the playback efficiency,Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces (Make : Hikvision / Dahua / Sony).
Supply of 4MP, Internet Protocol fixed BULLET CAMERA with following specification: ●1/2.5" Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection) ● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied ●On-board Storage - Built-in micro SD/SDHC/SDXC card slot, up to 128 GB, ● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W ● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. (Make: Dahua/Panasonic)
Supply, Installation, Testing and Commissioning of 42" smart LED TV with following specifications a) Full HD 4K monitor b) IPS pannel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANR h) True colour generator i) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN o) Magic remote p) Dimension 1242 x 724 x 55.1min(37). (Make: Sony/ LG /Samsung).
Supply and OFC patch of OFC Single mode Media Convertor with configaration charges etc.,
Supply and fixing of outdoor 4X6 PVC box with 102mmX77mmX102mm with all fixing accessories.
Supply and Clamping of CAT 6 armoured cable in suitable PVC Pipe 1" thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem) i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal) IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-T IEEE 802.5 16 MB; ISDN; TPDDI; ATM ii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant. Fire Rating: PVC : IEC 60332-1. iii. Conductor - Bare Copper Wire iv. Insulation - Polyethylene v. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm.
Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up.
Supply and fixing of POE 24 port switch 10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line.
Supply and Fixing of Rack with Accessories -Higher end 9 U Rack with LNS unit and fan extra for the above rack.
Supply and fixing of 1no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections.Scope cover wall cutting, grouting,flushing and making good on the wall. Higher End.
Supply and fixing of 1no.6A/16A two module 5 pin socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections.Scope cover wall cutting, grouting,flushing and making good Cocealed the wall. Higher End.
Earthing as per the ISI specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry.
Earthing as per PWD standard with an earth electrode of 2meter Class 'B' GI pipe of dia not less than 32mm complete with necessary masonary work
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection and etc to complete the work
Supply and run of 25mm x 6mm GI flat with necessary clamps / supports on wall / floor / ground for earth connection
Supply and run of 2 of No.8 SWG GI wire for guarding with cradle with No.8SWG GI wire at the equal interval of 1.5 meter and etc to complete the work
SRI LAKSHANA FOUNDATION (BID ID -1211074)
JAYJAYENTERPRISES (BID ID -1210914)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .