Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹24.1 L+₹4.7 L (24.2%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹24.7 L+₹5.3 L (27.3%)Rejected-Finance GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹25.2 L+₹5.8 L (30.1%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹29.5 L+₹10.1 L (52.1%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹37.9 L
EMD Value
₹75,800
Closing Date
8 Dec 2021, 6:00 pmClosed
GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR-208008
OUTSOURCING OF M AND O SERVICES FOR 33 KV MRS SUB STATION AT 110 BLOCK AND TAKE OVER POINT AT AFS KANPUR
2021_MES_487418_1
8538/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
GE (AF) E/M CHAKERI KANPUR
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) E/M CHAKERI
₹75,800
Yes
27 Dec 2021
10 Nov 2021
10 Dec 2021
10 Nov 2021
8 Dec 2021
24 Nov 2021
Amount
Outsourcing services for operation of 33 KV, Take Over Point, comprising of equipments as per Appendix 'A' to Schedule 'A' for routine O&M all as specified and directed round the clock in three shifts (i.e. 0600 Hours to 1400 Hours, 1400 Hours to 2200 Hours & 2200 Hours to 0600 Hours) including Sundays and Holidays with the following staff:- Electrician Skilled - 01 No. per shift
Outsourcing services for operation of 33 KV, 110 Substation, comprising of equipments as per Appendix 'A' to Schedule 'A' for routine O&M all as specified and directed round the clock in three shifts (i.e. 0600 Hours to 1400 Hours, 1400 Hours to 2200 Hours & 2200 Hours to 0600 Hours) including Sundays and Holidays with the following staff:- Electrician Skilled - 01 No. per shift Helper Semiskilled - 01 No. per shift Notes for Srl item 1 & 2 above:- In addition to manning and operation of installation, the following works will also be carried out by deputing additional manpower where required, to the entire satisfaction of Engr-in-Charge/GE :-(a) Minor repairs and preventive maintenance required to ensure serviceability and efficiency of complete MRS complex including supply of HT 33/11 KV fuse wire of proper size and minor spares such as nut, bolts,spring, lock nut of VCB, tripping coil of VCB as per sample, broom, duster, grass cutting tools, phawara, pick axes for cleaning/grass cutting of complete 33/11KV switch yards & sub stn bldg. (b) Record of activities such as voltage/current/PF/Energy consumed / temp of transformers / break downs / day to day maintenance of MRS yards/ attendence register / duty roster / pay distribution register of the whole staff employed by the contractor etc. (c) The contractor shall ensure that all safety precautions are strictly exercised by the staff employed by him. Adherance to IE rules and statutory rules in vogue must be ensured. The contractor shall be fully responsible for any mishap that occurs due to any fault of the employee or due to non adherance of safety norms. (d) The technical staff employed by the contractor shall be ITI holder with four years experience. (e) The technical staff shall be wear proper uniform on duty hours with black leather shoes which will be provided by the contractor. The colour of dress will be decided by Engr-in-charge. Name of operator and firm will be embrosed on left and right side of the shirt/coat. Group insurance will also be carried out by the tenderer of the whole staff employed. (f) Spare required for replacement will be measured and paid under appropiate items here-in-after.(h) The under mentioned tools kit will be provided at site with person on duty :- (i) Electrician tool kit such as screw driver set, tester, test lamp, cutting plier, insulation tape, search light with high focus battery, fuse wire of required size.(ii) Tongue tester(iii) HT Megger. (iv) Multimeter (v) CRC Soln.
Note for item No 1 :- (i) Two Nos. Electrician shall always be present in each shift. In case of absent of any worker the penalty twice per day per shift shall be imposed on the contractor quoted rate. (ii) Operator shall always be present in proper uniform of approved colour. If operator found without uniform the penality @ Rs 200.00 per day, per shift, per person shall be imposed on the contractor. (iii) Contractor shall be prepare duty roster of electrician and MRS log sheet submited to concerned incharge/office. (iv) The contractor shall carried the routine cleaning of the Sub station and equipment. If sub station area & equipment found dirty the penality @ 500.00 per day shall be imposed on the contractor. (vi) The contractor shall be provided tool kit,sefty tools/ device, Fist aid box, communication system, search lights, fuse wire (tin copper alloy 200 amps) and spare parts at the sub station. If not found, penality @ 500/- per day shall be imposed on the contractor. (v) The certificate of qualification and supporting documents of experience shall be provided by the contractor before starting the operation of contractor for approval of AGE. If not provided treated as absent. (vi) The contractor shall be provided tool kit,sefty tools/ device, Fist aid box, communication system, search lights, fuse wire (tin copper alloy 200 amps) and spare parts at the sub station. If not found, penality @ 500/- per day shall be imposed on the contractor.
Disconnecting of HT supply from 11 KV VCB of any make/type/capacity for repair works, servicing and taking out trolley with complete decarburizing the contact points, cleaning with CRC solution and inner body cleaning with vaccum cleaner etc and repair/replacement of defective parts found during servicing. Reassembling and testing of relays for tripping time setting, over current setting, earth fault setting etc including checking of vaccume intrupter, tripping mechanism and ratchet wheel & spring charging mechanism etc after servicing complete all as directed by Engineer-in-Charge.
Disconnecting of HT supply from 33 KV VCB/SF-6 breaker of any make/type/capacity for repair works, servicing and taking out trolley with complete decarburizing the contact points, cleaning with CRC solution inner body cleaning with vaccum cleaner etc and repair/replacement of defective parts found during servicing. Reassembling and testing of relays for tripping time setting, over current setting, earth fault setting etc including checking of its control panel and power TR protection system such as defferential realy, master trip relay, power TR oil/windinding temp, bucolz relay and mechanical system etc after servicing testing complete all as directed by Engineer-in-Charge. Note :- Supply & Fix in replacement of following items No (5 to 20) parts of HT VCB for the item No 3.00 & 4.00 of BOQ above.
Trolly alignment lever suitable for upto 1250 Amps HT VCB. Make/Type- As per existing sample.
Shunt trip closing coil assembly 110/220 volts, DC/AC. Make/Type- As per existing sample.
Shunt trip tripping coil assembly 110/220 volts, DC/AC. Make/Type- As per existing sample.
Shunt trip closing coil assembly 24-30/220 volts, DC/AC. Make/Type- As per existing sample.
Shunt trip tripping coil assembly 24-30/220 volts, DC/AC. Make/Type- As per existing sample.
Spring charging Motor Cut of switch. Make/Type- As per existing sample.
Ratchet wheel Assembly (small, large & middle gear assy). Make/Type- As per existing sample.
Manual spring charging gear assembly complete. Make/Type- As per existing sample.
Indicator lamp LED type complete with holder to read RYB with necessary wiring complete.
Spacer Heater. Make/Type- As per existing sample.
Thermostate 30-90 Deg.
Hooters. Make/Type- As per existing sample.
11KV, VCB Fixed contact suitable for upto 800Amp capacity. Make/Type- As per existing sample.
11KV, VCB moving contact suitable for upto 800Amp capacity. Make/Type- As per existing sample.
Spout insulator incl hardware suitable for 11KV VCB of various capacity.
11 KV, VCB, PT fuse 3.15 Amp complete as per sample.
S&F in replacement Bus Support insulators, non hygroscopic, track-resistant, high strength epoxy insulators complete all as specified and directed.
Supply, installation, testing and commissioning in replacement of 11KV Current Transformer with Indoor & Resin cast type single pole (Three core type) CTR-300-200/5+5A, STR - 18.4kA/1Sec, Class - 15VA/CL1.0+15VA/5P10 fixing on existing 11 KV panel including necessary connections, any modification required, addition/alteration required for fixing CT in existing 11 KV panel complete all as directed by Engr-in-Charge.
Supply and fixing in replacement cable jointing kit termination indoor type for HT 11KV grade cable for end termination joint complete with jointing material (Heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, 3 core cable and testing after jointing complete. Make :- Denson/Rechem/3M.
Supply and fixing in replacement I nuts, bolts, off sizes complete with 3mm thick washers as per site requirement fixed in repairs.
keerti trading corporation
BHATIA ENTERPRISES
Bharat Sales Corporation
GAURAV ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .