Loading…
Loading…
Tender Value
₹2.3 Cr
EMD Value
₹4.5 L
Closing Date
15 Jul 2026, 2:30 pm
Similar tender results from the same govt authority in the past 3 years.
Balance Electrical General works in BG-2 section and HQ MLG.
EL-CON-MLG-01-2026-27-KYQ
EL-CON-MLG-01-2026-27-KYQ
Open
12 Months
Unknown (Unspecified Location)
₹0
₹4.5 L
22 Jun 2026
22 Jun 2026
1 Jul 2026
Item Breakup - A-Balance Electrical General works in BG-2 section and HQ MLG
As per above item: 1:3:6 ratio, M-20 ( 1 cement : 3 cum sand: 6 graded stone aggregate 19/20mm nominal size).
As per above item Ordinary portland Cement grade - 53 MT Grade Total 30197.50
A-Balance Electrical General works in BG-2 section and HQ MLG
Supply of materials and wiring of light point through concealed wiring by 1.5 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by same size as P+N as per IS:732/2019 and modular type 6 1 amps controlling switch(with indicator type) to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface.
Supply of materials and wiring of fan point through concealed wiring by 1.5 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by same size as P+N as per IS:732/2019 and modular type 6 2 amps controlling switch(with fan marking) and module type step fan regulator of 100 W to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface.
Supply of materials and wiring of Exhaust fan point through concealed wiring by 1.5 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by size as P+N as per IS:732/2019 and modular 3 type 6 amps controlling switch (with fan marking) and module type step fan regulator of 100 W to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface.
Supply of materials and wiring of 5/6 amps plug point through concealed wiring by 4 1.5 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by by same size as P+N as per IS:732/2019 and modular type 6 amps controlling switch(with indicator type) and 2 modular 6 Amps 5 Pin universal socket to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface.
Supply of materials and wiring of 16/20 amps plug point through concealed wiring by 4 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by by same size as P+N as per IS:732/2019 and 5 modular type 16 amps controlling switch(with indicator type) and 3 modular 16 Amps 6 Pin universal socket to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface.
Supply, fitting, fixing, connection, commissioning and wiring of AC point by good quality accessories with proper connection complete with 16 amps MCB and plug point wiring by 6 6 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by same size as P+N as per IS:732/2019 and to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor.
Supply of materials and wiring of Mobile charging system through concealed/surface wiring with mobile keeping tray by 1.5 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealedrigid conduit pipe with earth continuity by 7 same size as P+N as per IS:732/2019 and modular type 6 amps controlling switch 3 no and 6/10 amp 5 pin modular socket 3 nos to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper size (i.e. thickness of mounting boxes of 3 mm and inside width of box should be 50 mm).All other accessories i.e. PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site color of the surface.
Supply & wiring of fan points & light points etc. for PP Shed & FOB wiring by 1.5 mmsq. HRFR PVC insulated single core stranded copper conductor/cable Con. to IS:694/1990 (Re- 8 affirmed 1997) in surface / recessed through medium class PVC conduit pipe/casing caping of suitable size & earth continuity 1.5 mmsq HRFR PVC insulated single core stranded copper wire, piano type switch, phenolic laminated sheet, suitable size M. S. box etc. with all accessories as required.
Supply and wiring by 0.75 sq mm single core FR PVC Insulated industrial grade copper conductor flexible cables for light fitting connection Conforming to IS 694
Supply and wiring by 1.5 sq mm single core FR PVC Insulated industrial grade copper conductor flexible cables for light fitting connection Conforming to IS 694
Supply and wiring by 2.5 sq mm single core FR PVC Insulated industrial grade copper conductor flexible cables for light fitting connection Conforming to IS 694
Supply and wiring by 4 sq mm single coreFR PVC Insulated industrial grade copper conductor flexible cables for light fitting connection Conforming to IS 694
Supply and drawing of Sub main line by single-core 6 sq mm PVC insulated 13 unsheathed FRLSH flexible copper cable with earth continuity by same size as per IS:732/2019 and through good quality hard PVCcasing/Conduit. (One RM consists of2 wires). Casing/conduit shall befixed on the wall/ ceiling by MS(6x40 mm) screw mat at aninterval not more than 300mm.
Supply and wiring of main line (concealed type) by 1.1 KV grade HRFR PVC insulated 14 single core 10 mm2 multistrand flexible copper cable conforming to IS:694/1990 through 25 mm dia. PVC conduit pipe including earth continuity by HRFR PVC insulated singe core 10mm2 multi strand flexible copper wire as per direction of Engineer Incharge at site.
Supply, fixing of 40 mm heavy duty PVC conduit pipe for wiring.
Supply, fixing of 25 mm heavy duty PVC conduit pipe for wiring.
Supply, fixing of 20 mm heavy duty PVC conduit pipe for wiring.
Supply and fixing of perforated cable trays with size 60mm (H) x 400mm (W) x3000mm(L) x 1.2mm (T) with horizontal & vertical bends, reducers, Tee's, Cross over, supports, brackets and other accessories as required confirming to IS/IEC- 61537.The cable tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .Cable trays are to be tested for Impact resistance test according to IEC 60068-2-75, Salt Spray test according to ISO 9227 as per IS/IEC 61537 test duration recommendation. The cable tray should not deflect more than 18 1/100th of the span length at SWL in Mid span for cable and the transverse deflection of all mounting accessories at SWL shall not exceed 1/20th of the length and manufacturer has to submit load chart and manufacturer declaration according to EN 61537. The cable trays, wall bracket system, Slotted U support system and all related accessories & fasteners should be tested according to IS 1893 to meet out the seismic Zone V requirement .The respective support system elements should be factory fabricated, selection of support system elements & installed guidelines as per the manufacturer recommendation in order comply seismic zone V (IS 1893) and vibration forces during earth quake. The cable ladder shall be supplied in standard length of 3000 mm. The cable tray is to be fixed as per direction of Railway Engineer. Make - ABB, Eaton, Schneider, OBO
Supply and fixing of perforated cable trays with size 60mm (H) x 300mm (W) x 3000mm(L) x 1.0mm (T) with horizontal & vertical bends, reducers, Tee's, Cross over, supports, brackets and other accessories as required confirming to IS/IEC- 61537.The cable tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .Cable trays are to be tested for Impact resistance test according to IEC 60068-2-75, Salt Spray test according to ISO 9227 as per IS/IEC 61537 test duration recommendation. The cable tray should not deflect more than 19 1/100th of the span length at SWL in Mid span for cable and the transverse deflection of all mounting accessories at SWL shall not exceed 1/20th of the length and manufacturer has to submit load chart and manufacturer declaration according to EN 61537. The cable trays, wall bracket system, Slotted U support system and all related accessories & fasteners should be tested according to IS 1893 to meet out the seismic Zone V requirement .The respective support system elements should be factory fabricated, selection of support system elements & installed guidelines as per the manufacturer recommendation in order comply seismic zone V (IS 1893) and vibration forces during earth quake. The cable ladder shall be supplied in standard length of 3000 mm. The cable tray is to be fixed as per direction of Railway Engineer. Make - ABB, Eaton, Schneider, OBO
Supply & fixing of bracket fan, 400mm sweep heavy duty industrial type to be commissioned on wall by fixing required number of nut/ bolt /washer & by suitable arrangement as per direction of Railway Engineer. Make - Usha, Khaitan, Orient, Crompton.
Supply & erection of exhaust fan 300 mm sweep including louver shutter, single phase, to be commissioned by fixing required number of nut / bolts washer on the wall as per direction of Railway Engineer. Make - Usha, Khaitan, Orient, Crompton.
Supply and fitting of 5 star rated 1500 mm energy efficient Ceiling Fan (BLDC motor type)
Supply and fitting of high volume low speed fan 16 ft with suitable VFD control panel and fixing support syructure and other accessories.
Supply & erection of Air Circulator- wall fan 750mm
Supply & fixing of 18-20watt LED indoor industrial T- 8 LED tubes is to be fixed in proper location as per direction of Railway Engineer. Connections of fittings are to be done by 25 1.5sq.mm FRLSH multi-strand single core copper wire through proper terminals. (Test certificate, guarantee / warranty certificate from manufacturer for 2 years from the date of commissioning are to be produced by the contractor at the time of supply of materials). make :Bajaj/ Havells/ Philips/ Jaquar/ Crompton make.
Supply & fixing of LED Recess light round/square size of 15 watt is to be fixed in proper location as per direction of Railway Engineer. make :Bajaj/ Havells/ Philips/ Jaquar/ Crompton make.
Supply & fixing of C24:C32 LED Recess light 600 mm X 600 mm square size of 36 watt is to be fixed in proper location as per direction of Railway Engineer. make :Bajaj/ Havells/ Philips/ Jaquar/ Crompton make.
Supply & fixing of LED Spot light round shape of 12/15 watt is to be fixedin proper locationas per direction ofRailway Engineer. of make :Bajaj/Havells/Philips/Jaquar/Crompton make.
Supply & installation of 250 W LED High bay light fitting for rolling/focus light with in- 29 built electronic driver and lamps housed in high grade aluminium pressure die cast with toughened glass and lamp efficiency> 120 lumen per watt. of make :Bajaj/Havells/Philips/Jaquar/Crompton make.
Supply and fixing of LED system wattage - 12 watt. ground burial luminaries of operating voltage range. 90-260 volt, operating temperature range -10degree C to +50 degree C ,rated voltage -240 VAC,50 HZ, of make :Bajaj/Havells/Philips/Jaquar/Crompton make.
Supply and fixing of LED 4 way linear decorative fixture with IP-67 housing power output 5 watt Cool white. of make :Bajaj/Havells/Philips/Jaquar/Crompton make.
Supply & fixing of LED Chain light with driver of 24watt of 5 mtr long each is to be fixed in proper location as per direction of Railway Engineer. of make :Bajaj/ Havells/ Philips/ Jaquar/ Crompton make.
Supply and fixing of Cross cut Furniture Tripod floor lamp with 12 W. Warm LED of make :Bajaj/ Havells/ Philips/ Jaquar/ Crompton make.
Supply & fixing of Track light 20 W. Warm LED. As per Philips models No. 31446 of make :Bajaj/ Havells/ Philips/ Jaquar/ Crompton make.
Supply, fitting, fixing and commissioning of 2 ton, 5 Star rating, Split type Air 35 Conditioner complete system i.e. split unit, compressor, condenser, copper tube,insulation material etc. All consumables forfixing arrangement to be provided andexecuted by the firm as per the direction of Engineer in charge at site. Firm will bere responsible for all labour works including one years warranty of the equipment with 10 year warranty on compressor and trouble shooting if any.
Supply of Self drinking Water cooler with (Non CFC refrigent) energy efficient compressor, cooling capacity Ltrs/Hr: 150, Type : Storage, Storage Capacity Ltrs.:150, Rate of Max. energy consumption watt :1550.
Supply, installation, testing & commissioning of Geyser 25 lt. capacity.
Supply and fitting of 10 KVA, On-Line UPS suitable for Single Phase AC Input voltage range 160-260V, 50+/-1.5HZ and S/Phase AC Output 23+/-1% volt, 50+/-0.5HZ, Indicative Back-up time 60 Minutes, with 15 nos 120 Ah. Battery system with trolley.
Supply, installation, testing andcommissioning of 2 KVA UPS with battery.
Supply, installation, testing SITC of VRLA lead acid Battery of 100 Ah. for 2 KVA UPS.
Supply of Radio detection Precision pipe and cable locator/ route tracer.
"Supply & erection of PVC rigid conduit pipe 25 mm dia medium gauge to be fixed on 42 wall by shaddle etc & required size screw at an interval not more than 30 cm with necessary coupler /elbow /Tee / 4way etc as per direction of Railway Engineer. Make- Diamond, Presto Plast, Ajanta Plast"
"Supply & erection of PVC rigid conduit pipe 40mm dia medium gauge to be fixed on 43 wall by shaddle etc & required size screw at an interval not more than 30 cm with necessary coupler /elbow /Tee / 4way etc as per direction of Railway Engineer. Make- Diamond, Presto Plast, Ajanta Plast"
Supply & fixing of junction box with 4 way terminal including proper fixing arrangement is to be fixed in proper location as per direction of Railway Engineer. Make - Hensel, Walther, Emitter
Supply & laying of GI strip including suitable size hole with GI nuts& bolts ,washer or 45 welded joints where ever required as per direction of Site engineer in charge. As required as per direction of Engineer incharge. (I) Supply & fixing of GI strip of size 25mm of 3mm thick. 0.47 kg p/mtr. As required as per direction of Engineer incharge. Square
Design, manufacture, display of wall /hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be 46 less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. A suitable size end cap of 1.5 mm thick SS 304 should be provided. Square
Erection and installation of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 47 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 um thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided
Supply, installation testing commissioning of station name in 3D letters as in a frame in Hindi, English and Regional matters. (Note: The unit is taken Each which means Ht Inches)
Supply, installation,testing & commissioning of High Mast Tower 12.5 mtr long including 120 watt LED luminaries , carriage , panel complete with erection with all accessories 49 being fulfilling the necessary criteria-dynamic loading , proper foundation, lantern carriage, head frame, winch power tool , earthing cables including luminaries as per specification of Annexure-A. (Test certificate & guarantee/warranty certificate from the manufacture is tobe produced by the contractor at the time of billing. Make - HMT - BPP, Utkarsh, Crompton
Supply, installation,testing & commissioning of High Mast Tower 20mtr long including 120 watt LED luminaries , carriage , panel complete with erection with all accessories being fulfilling 50 the necessary criteria-dynamic loading , proper foundation,lantern carriage,head frame, winch power tool ,earthing cables including luminaries as per specification of Annexure-B. (Test certificate & guarantee/warranty certificate from the manufacture is tobe produced by the contractor at the time of billing. Make - HMT - BPP,Utkarsh, Crompton
Supply and fixing of Town Glow PostTop steel pole withluminiers made outof GI pipe 51 sectionwith lower portionof pole made ofMS. The polesheight 3 mtr,diameter 50mm to 90 mm , base ismade of 8mm/12mm thick MSsheet with holessuitable for 16 mmfoundation bolts isto be fixed inproper location aspr direction ofRailway Engineer.Make- Crompton,Philips , Bajaj
Supply & erection of150/160watt LED Floodlight, IP-65 fitting complete set withpressure die cast aluminium housing andother accessories.
Supply & erection of Flood light luminaire LED 120 W, 5700K,12800 lumen, IP- 65energy saving, environmental friendly, withfront toughened glass & new generation high power LED with electronic driver.
Supply , fixing & commissioning of 65 mm(Dia) (medium) G.I pipe of 5 Ft includingbase foundation for fixing post top lamp.
Supply, testing, installation & commissioning of Dynamic color changing Linear light fixture of 48 watt suitable for outdoor facade lighting applications (RGBW). Luminaries opticsshall be highly efficient, UV and temperature-resistant lens systems. Rated input supply of 24V DC Power Factor: >0.9, THD < 15%. The luminaire must be controllable through DMX. The body of the fixture must be made of Die-cast aluminum alloy housing with heat resistance tempered glass cover and surface finished- double powder coated, outdoor grade, anti UV with suitable IK 07 rating to sustain any outer objects from damaging the fixture. The luminaries must be weather proof with IP- 66 or higher rating with operating temperature : 0°C to 50°C and humidity : 10% to 90%. Housing must have adjustable bracket to set the light and illuminate to required area. The entire work is to be executed as per direction of Railway Engineer. Make- HPL, Havells, Bajaj, Philips.
Supply, installation, testing & commissioning of 90 watt Narrow Beam RGBW LED Projector Lights with following technical features: Aluminium Die-casting body with plastic coated surface, each LED with a rod for heat transfer having UV stabilized toughened glass front cover, luminary should be round shaped to provide asymmetric beam angle suitable for architectural facade lighting, Tilt : adjustable through 180 degree or more, IP-66 or greater ingress protection for outdoor application suitability, secondary optical lenses provided on each LED of fitting with suitable narrow beam angle, DMX compatibility within built decoder. Control Mode :DMX512, DMX Controller 56 can achieve 16.7M NS1 35 Numbers26941.62 At Par 942956.70 colors, Rated Input Supply of LED: Highly reliable DC24Vconstant voltage power supply which drives the RGBW LEDs High Power LED,Power Consumption : 90W(approx.) per fixture however as per requirement wattage may be increased /decreased to meet the desired effect of Facade. Power Efficiency : >85%,Power factor :>0.95,Operating Frequency: 50 Hz,Operating temperature : -10 to+55 degree centigrade, Life Span: >50000 hours,Warranty : 5 Years ,Electrical Safety Class: Class 1.(The work to be executed as per direction of engineer in charge at site. If any other items have been omitted but required for efficient working of projector light for facade lighting it would be responsibility of contractor to supply and provide such items. However the quoted rate shall be inclusive of those items &TheLED light must be conforms to the technical specification i.e. attached in the tender document)
Supply & fixing of RGBWDMX controller for lightcontrol working temperature -10°C to +50°C is to be provided for controlling of RGBW light. The work is to be executed as per direction of Railway Engineer. Make- HPL, Havells, Bajaj ,Philips
Supply & fixing of signal driver is to be provided for communication of light & DMX controller. The work is to be executed as per direction of Railway Engineer Make - HPL,Havells, Bajaj , Philips
Supply & fixing of power supply input voltage of AC85-265V, 50-60 Hz. The Output 59 Voltage shall be 24V DC. The Power Consumption of the Power supply unit min 200W toprovide power to RGBWlight . The work is to beexecuted as per directionof Railway Engineer Make -HPL, Havells, Bajaj ,Philips
Supply & fixing of digital timer for automatic RGBW light on & off. The work isto be executed as perdirection of Railway Engineer. Make - HPL,Havells, Bajaj , Philips
Supply & fixing of contactor is to be provided as per direction of Railway Engineer. Make - HPL, Havells, Bajaj , Philips
Supply & fixing of power supply panel box to install signal driver , power supply, adopter and MCB etc. The work is to be executed as per direction of Railway engineer. Make- HPL, Havells, Bajaj ,Philips
Supply & fixing of power adopter 5V DC for DMX controller power supply is to be done as per direction of Railway Engineer. Make- HPL, Havells, Bajaj ,Philips
Supply & fixing of DP MCB 20A to (up to 63A) is to befixed in proper location asper direction of Railway
Supply, installation, testing & commissioning of 120 watt RGBW/Warm White 65 Floodlight up exterior wall facade of station building with following features: Aluminium Die-casting body with surface anodic oxidation and UV stabilized toughened glass on the front, Rectangular shaped luminary suitable for wall facade application, adjustable tilt as per site requirement, Suitable beam angle asper site requirement, IP66 ingress protection, Power Consumption: 120W per fixture however asper requirement wattage may be increased/decreased to meet the desired effect of Facade. Input Voltage: AC220V,PowerEfficiency :>85%, Power factor: >0.95,Operating Frequency : 50Hz, Output Color :RGBW/Warm White, Life Span :>50000hours, Warranty : 5 Years, Electrical Safety Class : Class 1. (The work to be executed asper direction of engineer in charge at site. If any other items have been omitted but required for efficient working for facade lighting it would be responsibility of contractor to supply and provide such items. However the quoted rate shall be inclusive of those items).
Supply, fitting and connection of VTPN DB double door 12 Way including incomer 160 A MCCB =1no. and outgoing TP MCB=6 nos. and SP MCB =18 nos.
Supply, fitting and connection of TPN DB 8 Way (8+24) with metal door includingsupply and fixing of following as under (i) MCB 4 P 63 A - 1 no. (ii) SP MCB (6-32)A = 24 nos.
Supply and fixing of HDPE pipe of out sidedia 110mm, 6kgf/cm2, 6.0 mtr each 68 lengthand threaded to match with Tee, Elbow,Union and Socket etc conforming to IS4984/1995 clamped withpole/truss/bracket made of galvanised flatof size 50x6mm with galvanised nuts &bolts of size 50x12mm as per direction ofEngineer In Charge at site.
Supply & fixing of HDPE pipe of out sidedia 50mm, 6kgf/cm2, 6.0 mtr each lengthconforming to IS : 4984/1995, clampedwith bracket by 50x5mm MS flat clamp with nuts & bolts MS of size 50x12mm asper direction at site.
Supply & erection of XLPE insulated PVC sheathed armoured underground cable of 4 70 core 35sq mm Alu. Armoured Conductor graded 1.1KV for working voltage up to 1100 volts conforming to IS 7098 with latest amendment with making end termination with brass compression gland and lug as required.
Supply & erection of XLPE insulated PVC sheathed armoured underground cable of 4 71 core 185sq mm Alu. Armoured Conductor graded 1.1KV for working voltage up to 1100 volts conforming to IS 7098 with latest amendment with making end termination with brass compression gland and lug as required.
Supply & erection of XLPE insulated PVC sheathed armoured underground cable of 4 72 core 16sq mm Alu. Armoured Conductor graded 1.1KV for working voltage up to 1100 volts conforming to IS 7098 with latest amendment with making end termination with brass compression gland and lug as required.
Supply & erection of ISI marked size 4 core 95 sq.mm XLPE insulated, PVC outerseathed armoured cable with aluminum conductor, suitable for 1100 Voltgrade IS: 7098 Part-1 1988 with amendment number 1 and 2 and 3 Reaffirmed 2005,
Supply & erection of ISI marked size 4 core 70 sqmm XLPE insulated, PVCouterseathed armoured cable withaluminum conductor, suitable for 1100 Voltgrade IS: 7098 Part-1 1988 withamendment number 1 and 2 and 3Reaffirmed 2005,
Laying, commissioning of LT/HT cable XLPE insulated power cables with armoured 75 aluminum conductors of different sizes partly along the pole and partly through ground in cable trench. Loading, unloading & carrying of cable to actual work site by contractor own arrangement as per instruction of Engineer in charge at site.
Making of cable trench dimension 150/200/300 mm wide and 1000 mm deep by 76 excavation of earth. The cable shall be protected by laying of brick in 3 sides with filling of sand as per the direction of Engineer in charge at site (Outside track crossing) and back filling of earth/ ballast. The work to be executed as per enclosed specification.
Supply & Installation of maintenance free earth using copper coated steel rods as per RDSO specification No.RDSO / PE/SPEC/PS/109-2008 (Rev '0'), Amdt "2" & Drg. No. NFR/CEE/GS/10 (EARTHING SYSTEM)/06/2016. (As per Spec. No.NFR/E/C/GS/10/Earthing System). As required as per 77 direction of Engineer incharge.
Supply and erection of earthing by 50 mm GI pipe, 3 mtr long 4.05 mm thickness 78 including construction of earth pit, RCC earth cover slab with filling/mixing of salt, charcoal etc of required quantity and earth continuty by 25x3 mm GI strip with GI nuts bolts washer etc.including welding, earth resistance flag etc. as per Drg.No. NFR/CEE/CON/GS/10(earthing system)/04/2016 & as per Technical Specification No. NFR/ELECT/GS/10(EARTHING SYSTEM).
Supply of galvanized tubular pole 12 mtr long type 410SP-66 with step length 5.80- 3.10-3.10mtr sectional dia 219.1x193.7x165.1mm sectional thickness 5.9x4.85x4.5mm asper IS 2713-1980 including suitable size base plate and cap on top.
Erection of tubular pole 9/12/14.5mtr long including digging the pit 1/5th of the total length. The whole work shall be executed as per direction of Engineer in charge at site
Supply and erection of PCC/RCC works for foundation of column,pillars,posts,struts 81 etc. excluding the cost of cement shuttering and centering.(CC block will be 30 cm dia with height upto the pole depth below GL and 30 cm above GL and 10 cm below base plate including tie- muffinng of DP)-a)1:3:6 (M-10)-1 cement,3 sand,6graded stone aggregate 20 mm nominal size
Ordinary port land cement grade-53 frade
Supply & fixing of GI Channel 100X50X50X5mm of suitable size (7m/4m/3.3m) long Bracket (9.56 Kg/mtr) for holding insulators, lightning arrester etc with necessary hole by drill.
Supply & fixing of GI Channel 75X40X40X5mm of suitable size (4m) long Bracket (7.14 Kg/mtr) for holding insulators etc with necessary hole by drill.
Supply & fixing of GI angle 65X65X5mm of suitable size (3.3m/2.5m long for Bracket (4.90 Kg/m) for holding pole etc with necessary hole by drill.
Supply & erection of Galvanised stay setfor HT OH line comprising of 20 mm diawith 86 1.8 mtr long stay rod, anchor plate ofsize 30x30cmx6mm/45x45x7.5mm, turnbuckle ( 20mmx600 mm), 20mm thimble ,stay clamp, 7/10 mm dia GI stay wire, Guystrain insulator of size 85 x 140 mm for11KV as per ref. IS 5300/1969, and ccfoundation with ratio 1:3:6 includingexcavation, refilling etc.
Supply, fitting, fixing, testing & commissioning of 11 KV 400 amps GO-DO set with 87 operating handle and fixing of the same with pole by 2200 mm long MS channel ( 75x40x40x5) mm with ( 50x5)clamp with necessary nut/bolts. etc. The whole work shall be executed as per direction of Engineer in charge at site.
Supply, drawing and stringing of ACSR conductor Rabbit of size 6/1/ 3.35mmconforming to IS : 398-Pt.II-1976 including binding and jumpering. There should not be any joint between the span.
Supply and drawing of guard wire by 8 SWG GI wire and cross lacing by 10 SWG GI wire. Cross lacing shall be provided not more than 1 meter interval.
Suply and erection of 3Nos. Zinc Oxide Station Class-I lightning arrestor suitable for 3 90 wire 33KV with rated voltage 30KV(RMS) and a normal discharge current rating of 10KA as per IS:4004 (1985), complete with galvanised clamping arrangement, GI bolts, nuts, washer etc. (3Nos in a set).
Supply and laying of GI strip 25mm X 5mm (1.02Kg/M)for laying from earth pipe to transformer/ body/ panelboard/ switch board earth neutralconnection with LT & HT body etc.
Supply and drawing of 8/10 SWG GI wire shall be provided for earthing of pole etc.
Supply & erection of danger board size 8"x6" on MS clamp made of 20x3mm for 33/11/1.1 KV showing the voltage grade,skull symbol etc.
Supply & erection of barbed wire upto height 2.5m to be fixed on pole with 2 nos. of clamps of suitable size and as per direction of Engineer Incharge at site.
Supply & erection of 2P composite polymer11 KV ball & socket type Disc insulator with minimum creepage distance 320 mm & sectional length 300mm made of one piece injection 95 molded directly to high quality, corrosion resistant, fibre glass discharge rod and sealed to the hot dipped galvanised carbon steel end fittings by bead of silicon rubber complete with all accessories. Conforming to IEC : 1109 standard or as per IS : 731 (1971) & 2488(Pt-II) 1974 complete with hardware fitting
Supply & erection of 2P composite polymer11 KV Pin insulator with minimum 96 creepage distance 340mm & sectional length 235mm made of one piece injection molded directly to high quality, corrosion resistant, fibre glass discharge rod and sealed to the hot dipped galvanised carbon steel end fittings by bead of silicon rubber complete with all accessories conforming to IEC : 1109 standard or as per IS : 731(1971) & 2488 (Pt-II) 1974 complete with hardware fitting 1658016.0
Supply, installation, testing and commissioning of 500KVA, 11/0.433 KV, 50Hz, 3-ph, oil immersed, ONAN cooled ,copper wounded, 4/5 Star rated, energy efficiency BIS/BEE level-II, outdoor type.Dyn-11 Star delta , pad mounted distribution transformer with first filling of oil as per 97 IS:335 with latest amendements, oil level indicator with minimum marking, rollers, explosion vent, tap changer(+/-2.5%,+/-5%,+/-7.5 %), marshalling box, conservator with oil filling hole and cover with drain plug, air release device, HV-outdoor bushing, LV-outdoor bushing, Oil temperature indicator,drain valve with plug,filter valve with plug,name,rating ,and terminal marking plate,2 nos. earthing terminals,lifting lugs,silica gel breather,thermometer pocket(including industrial thermometer),radiators,inspection cover,buchholz relay,arching horns and other accessories conforming to IS:1180-I/2014 with latest amendments.
Supply, installation, testing & commissioning of indoor type floor/ wall mounted cubicle type main power panel suitable for 415v.50Hz AC supply made out of 14 SWG CRCA sheet .The panel shall be CPRI approved totally enclosed, dust & vermin proof, neoprene gasket of thickness not less than 2mm shall be used between all adjacent units & beneath all covers so that the joints are effectively dust vermin proof. The panel shall have uniform height & depth and plugged with insulated &spring loaded thumb screws. The bus bar chamber shall have three phase & neutral copper busbar of ratings not less than 500Amp. The panel shall be completely factory wired with insulated FRLSH copper wire & shall be ready for connection to be equipments. The panel shall be painted with two coats of synthetic enameled grey paint over a coat of red oxide primer. Cable connection to be done by lug /socket of proper size and cable gland to be provided with proper insulation at every cable entrance and exit of panel. Necessary spreader link is to be fixed in proper 98 location as per direction of Railway Engineer. Pre- inspection of materials by RITES should be imparted. The panel shall consists of the followings : Incomer 400A 4P 36ka = 1 no. MCCB with O/L, S/C, E/F Microprocessor release with communicable by on board ethernet, inbuilt energy metering, Both side spreader link, Extended Rotary Handle. Separate LSIG Fault indication on display. The MCCB should be selected for making communication, transmission of measurements, states and alarms from circuit-breaker to system, transmission of events to the system . There should be LED indicating lamp for showing On, OFF, TRIP indication on the panel door etc = 1 no, 400A 4P, contactor = 1 no. A/M Selector Switch = 1 no Start Stop Push Button =2no, R,Y,B,ON,OFF,TRIP Indication Lamp = 6 no, 6A SP MCB = 4 no, OUTGOING 250A 4P 36KA MCCB with O/L, S/C, E/F Microprocessor Release with communicable by onboard Ethernet, = 4 no 250A 4P Contactor = 4 no Start, Stop Push Button = 8no 8 no, 6A SP MCB = 8 no, Fabrication = 1 no is to be fixed in proper location as per direction of Railway Engineer. Pre-inspection of materials by RITES should be imparted. Make - Legrand, LK, ABB, Schneider , Havells
Supply & erection of 6.0mtr. long heritage Decorative pole (Customize designed) with 99 PU painted over Galvanised Street Pole with decorative sleeves along with decorative single arm 1 mtr long Including 4 nos. foundation bolts of size 500mm long X 20mm Dia with base plate of size 220X220X12mm thick. Tolerance as per IS : 2713/1980. As per direction of engineer incharge at site.
Supply and execution of PCC/RCC work for foundation of Oct. Pole including scaffolding etc. (Excluding the cost of cement). As required as per direction of Engineer incharge.
Supply, fitting & fixing of Outdoor type 1x45Watt Decorative Street light fitting including all accessories. Aesthetically designed with aluminium enclosure, suspended mounting arrangement with IP-65. As required as per direction of Engineer incharge.
Dismantling of overhead alignment like conductor ,insulator ,bracket etc ,handed over to concerned authority at their depot by contractor's own arrangement. As required as per direction of Engineer incharge.
Uprooting of existing pole without damaging the bottom of the pole ,handed over to concerned authority at their depot by contractor's own arrangement. As required as per direction of Engineer incharge.
Supply and erection of PCC/ RCC works by 1:1.5:3, M-20 ( 1 cement :1.5 sand: 3 graded stone aggregate 20mm nominal size) for transformer foundation size 6mx5mx1.3m etc. excluding the cost of cement shuttering & centering.
Earth work in excavation and dumping within 50m lead, including incidental work etc. for All kinds of soils
Form Works : Centering and shuttering including syrutting, propping etc and removal of form for : foundation, footings, baseses of columns, raft foundation of washable aorons, pile caps, footings of POB etc.
Supply & mixing of Ordinary portland Cement grade - 53 Grade
Supply and fixing of reinforcement for RCC works including strengthening , cutting, bending, placing in position and binding all complete: Thermo Mechanically Treated bars with binding strips etc if required.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
FurtherInstructions..pdf
ATTACHMENT
GCCAprilworks2022.pdf
ATTACHMENT
ACS.pdf
ATTACHMENT
TenderBooklet-KYQ.pdf
ATTACHMENT
Download all tender documents and submit your bid