Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC 801802 SAKAR IV OPP MJ LIBERARY ELLISBRIDGE ASHRAM ROAD AHMEDABAD AHMEDABAD GUJARAT 380006 | 801802 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹20.6 L+₹2.8 L (15.6%)Rejected-Finance | L2 | Rejected-Finance Being L2 |
Tender Value
₹17.9 L
EMD Value
₹35,900
Closing Date
5 Jul 2022, 6:00 pmClosed
Col Jiagar Trivedi, SM
HQ CWE (AF) Gurugaon Old Palam Road Delhi Cantt -110010
COMPREHENSIVE ANNUAL MAINTENANCE AND OPERATION FOR WATER SCADA SYSTEM INSTALLED AT AIRFORCE GURGAON UNDER GE (AF) GURGAON
2022_MES_509133_5
CWE/GGN/GT-48/2021-22
Open Tender
Information Technology
Item Rate
330 days
AF STn Gurgaon
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) Gurgaon
₹35,900
Yes
22 Sept 2022
15 Jun 2022
7 Jul 2022
15 Jun 2022
5 Jul 2022
22 Jun 2022
15 Jun 2022 - 21 Jun 2022
Amount
M & L for Service/Repair for the automation water supply system installed at Master Monitoring & operating master panel via 1 No micro processor based Remote Terminal Unit Panel for 1 Nos UG Sump , 3 Nos Booster & 1 No Submersible Pump Set , 24 nos Tank monitoring slave panel installed at TEJAS PH. The Scope of work includes carrying out complete repairs as required of all the sub systems viz. RTU(REMOTE TERMINAL UNIT) based Master Monitoring and Annunciating control panel 01 No.(with all the accessories), motorised valves ., pressure Transmitter, Level sensors, Level Switches, Remote communication panels, Gateway, Wireless Hotspot Netwrok (with all its accessories), personal computer, UPS, LED Graphic Display, SCADA software for Automation system and generate backup of SCADA Database - 01 No replacement of unserviceable parts, refixing of old serviceable parts/new parts if any and preparing the records/register complete for the following places complete all as specified and directed. OEM :- M/S CIMON SOFTWARE(INDIA) PVT LTD (1) Tools and Machinery for : (a) SCADA Automation of Tank level monitoring for Building - 03 to 06 (b) SCADA Automation of Tank level monitoring for Building - 07 to 11 (c) SCADA Automation of Tank Level monitoring for Building - 13 to 17 (d) SCADA Automation of Tank Level monitoring for Building - 18 to 21 (e) SCADA Automation of Tank Level monitoring for Building - 22 to 23 (f) SCADA Automation of Tank Level monitoring for Building - 24 to 26 (g) SCADA Automation of Tank Level monitoring for Building - 27 to 29
(i) The Data transmission shall be Wireless transmission/receiver unit modem using WI-FI devices/GSM Net work/RF based network/wireless media with coverage of 1.5 KM LOS with no recurring charges/rental charges/maintenance charges of media for SCADA Remote monitoring & operation of complete water supply. (ii) With automatic controlling of pump set start/stop condition via micro processor based multi step timer. (iii) The Main Master pump set controlling panel shall be micro processor controlled and NON PLC based & shall to raise alarm/messages, alert to specified mobile No in case of any failure in automation system. (iv) With UG Sump water level indication 0% to 100%. (v) Single/Reverse phasing,Over/Under Voltage (OV/UV), Unbalance voltage (UBV) ,Short circuit (SC),Over Load (OL) & pump set dry running protection & alarming through messages to specified mobile no. (vi) With pump set sequencer for 2Nos booster pump set . Note: Panel Inspection by agency RITES/TUV/BVQI before supply and report to be submitted before installation.
Operation of SCADA software for the automation water supply system installed at Master Monitoring & operating master panel via 1 No micro processor based Remote Terminal Unit Panel for 1 Nos UG Sump , 3 Nos Booster & 1 No Submersible Pump Set , 24 nos Tank monitoring slave panel installed at TEJAS PH. The Scope of work includes carrying out complete monitoring as required of all the sub systems viz. RTU(REMOTE TERMINAL UNIT) based Master Monitoring and Annunciating control panel 01 No.(with all the accessories), motorised valves ., pressure Transmitter ., Level sensors, Level SwitcheS, Remote communication panels, Gateway, Wireless Hotspot Netwrok (with all its accessories), personal computer, UPS, LED Graphic Display, SCADA software for Automation system and generate backup of SCADA Database - 01 No replacement of unserviceable parts, refixing of old serviceable parts/new parts if any and preparing the records/register complete for the following places complete all as specified and directed. OEM :- M/S CIMON SOFTWARE(INDIA) PVT LTD (1) Min one technician will be deployed for operation of SCADA SYSTEM. (2) Tools and Machinery for : (a) SCADA Automation of Tank level monitoring for Building - 03 to 06 (b) SCADA Automation of Tank level monitoring for Building - 07 to 11 (c) SCADA Automation of Tank Level monitoring for Building - 13 to 17 (d) SCADA Automation of Tank Level monitoring for Building - 18 to 21 (e) SCADA Automation of Tank Level monitoring for Building - 22 to 23 (f) SCADA Automation of Tank Level monitoring for Building - 24 to 26 (g) SCADA Automation of Tank Level monitoring for Building - 27 to 29
Supply & installation of Internet Security anti virus software with one user license for one year.
Supply & installation of Micro processor Wireless (RF Remote Terminal Unit) transmission/receiver unit modem using WI-FI devices/GSM Net work/RF based network/wireless media with coverage of 2KM perimeter with no recurring charges/rental charges/maintenance charges of media with Master Transmitter unit for opening and closing of 50mm filling line motorize valve on OHT empty/full condition with water level transmitter, of media for SCADA Remote monitoring & operation of complete water supply , with feedback retrieved from from 4 nos field sensor per OHT Micro processor controlled and should be capable to over ride the system manually in case of auto failure.The system will also have an, Operating volate 85-230 V AC , inbuilt IO module with programming 2 AI,6 DI, and 2 DO ,
Supply and fixing UPS of suitable capacity 600 VA, 230 V AC FOR MASTER CONTROL STATION complete all as specified and directed.
Supply and fixing Field sensor for level monitoring for OHT for measurement of Level complete all as specified and directed. Make:- Crystal/Banner/Cristal/Mahalaxmi (each tank 4 Qty.)
Supply and fixing Ultra sonic non contact sensor for level monitoring for UG Sump with Following specification: - 12 to 24 DC operatinted output 4-20 mA. Range 8 mtrs complete all as specified and directed.
Supply and fixing Butterfly Valves of 150 mm line size along with Motorized actuator complete all as specified and directed.
Supply and fixing Butterfly Valves of 50 mm line size along with Motorized Actuator complete all as specified and directed.
Supply and fixing display for water level monitoring of OHT in ratio from 25%,50%,75% & 100% for OHT along with Mimic Graphic coloured display screen of Size 12”/12” for water level of OHT Tanklevel monitoring complete all as specified and directed.
Supply and fixing Pressure Transmitter ( Range 0 – 10 Bar ) as directed.
Supply and fixing 8 channel relay card 2 C/O, 24 V DC operated for Mimic graphic display and valve operation complete all as specified and directed.
Supply and fixing of network provides enterprise class WIFI hotspot features in an existing, reliable hardware platform Wireless Wi Fi switch for Main PH to Slave (Tank) between communicion, data transmit and received , POE operated complete all as specified and directed.
Supply and fixing of Wireless Gateway Unit with inbuilt RF and GSM/GPRS Modem. 1. RTC : Real time clock for time based operations. 2. Multiple Communication Ports for Field and MCS communications :Two-way simultaneous communication with multiple Level controller using RF and MCS using mode. 3. Communication Protocol Support : ModbusTCP/IP, ARP, RARP, ICMP, IP, UDP, DHCP, DNS, TFTP 4. Enclosure : Polycarbonate. 5. Protection :IP 65 6. Power Supply: Universal AC input 85-264 VAC, 50/60HZ 7. Wireless Communication With Level Controller, Capable of Mesh Networking
Supply and fixing of ARM7 based CPU Card with RS-485, USB, Ethernet, 2 Nos. RS-232 Port, SD card Socket, Real Time Clock of Model iRTU 6000 complete all as specified and directed.
Supply and fixing of Analog and digital Input Output interface Unit of Model iRTU 6000 complete all as specified and directed.
Supply and fixing of 16 Digital Input, 8 Analog Input Module of Model iRTU 6000 Make : Cimcon
Supply and fixing of 16 Digital Output Module of Model iRTU 6000 complete all as specified and directed.
Supply and fixing of RF External 3dBI antenna Unit along with extension Patch cord complete all as specified and directed.
Supply of Relay - 2 C/O, 240 V AC/ 24 VDC for Master and Slave Panel complete all as specified and directed.
Supply and fixing of 24 V DC SMPS/ 5/12 VDC SMPS 2 AMP of Model iRTU 6000 complete all as specified and directed.
Supply and fixing of 5/12 VDC SMPS with battery Charging and cut-off Module of Model iRTU 6000 complete all as specified and directed.
Supply and fixing of 24 V DC SMPS , 2 AMP of Model iRTU 1000 complete all as specified and directed. Make : Meanwell
Supply and fixing of panel door for Slave panel complete all as specified and directed.
Supply and fixing of 6A DP MCB Class C, complete all as specified and directed. Make : Siemens
Supply and fixing of Indication Lamp 230 VAC operated for master and Slave panel complete all as specified and directed.
Supply and fixing of LED red/green for Pump indication in mimic panel complete all as specified and directed.
Supply ,installation, testing & Commissioning of high torque motorize valve for Priming purpose with gears and adopters self Lubricating Type, Weather proof with protection against , over voltage Jamming of valve and over current protection with manual by-pass arrangement to open/Close the valve on power failure- Size:- 25 mm(1”) , Ball/Butterfly valve with geared motor on top , Designed line pressure 10 kg/sq cm, Operating angle; - 90 degree , Operating Voltage :- 230 V AC Supply only of LED driver circuit for Water Level Indication complete all as specified and directed.
Supply only of LED driver circuit for Water Level Indication relay controller Make- CAT NO. LED-12-12-01 of CIMCON or Equivalent to match with the existing specifications complete all as specified and directed.
Net Contract Sum will be after deducting Sch of Credit of Rs 4518.00
Recktronic Devices and Systems
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .