Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Others-does not belong to concerned panchayat or block as desired in SBD of above NIT |
Tender Value
Refer Docs
EMD Value
₹13,200
Closing Date
13 Dec 2021, 4:00 pmClosed
Executive Engineer
Electric Division JPDCL Udhampur
erection of HT, LT Line with substations
2021_PDD_145655_1
ED/UDH/47 of 2021-22 dt. 29-10-2021
Open Tender
Electrical Works
Turn-key
90 days
Panchayat Dhalper of Block Jaganoo in District Udh
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Executive Engineer Electric Division JPDCL
₹13,200
11 Feb 2022
30 Oct 2021
15 Dec 2021
30 Oct 2021
13 Dec 2021
30 Oct 2021
30 Oct 2021 - 5 Nov 2021
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for laying of HT line with Weasel Conductor at W.No-3, Dhalper.
9 Mtr. Long ST Pole (ST-410 SP33)
GI V cross-arm with top Bracket including clamp
GI Channel X-arm including clamps and braces
0.03 ACSR Weasel conductor
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
11KV Pin Insulator (Polymeric) with Pins (12kv, 5KN) Creepage Distance 320mm
11KV Disc Insulators (Polymeric 45KN ) creepage distance 320 mm with tension fittings
Earthing complete by GI Rod 20 mm 2.5 mtr long through G.I Strip 25X3 mm in HT Lines
Painting of ST poles 9 mtrs long with one coat of Red oxide
Painting of ST poles 9 mtrs long with 2 coats of Aluminium paint
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Creation of 1 no. 25KVA Distribution Transformer at W.No-3, Dhalper.
11/0.433kV, 3-phase 25KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor, 9 kV, 10 kA, LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical type
11 kV Horn Gap Fuse Set 3 Phase 200A
120 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Al Stranded Conductor FRLS type
9 Mtr. Long ST Pole (ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
LT Distribution box for 25 KVA DTR with MCCB
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip 50mmX 6mm for neutral earthing of size 32 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Cement bottoming of ST poles in 1:2:4 mix as per REC standards
Danger Plates with Clamps
Painting of Substation's ST Poles/cross arms/clamps with one coat of Red Oxide and two coats of Aluminium Paint
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for laying of LT line (3-phase, 4- wire) with Weasel Conductor at W.No-3, Dhalper.
8 Mtr. Long ST Pole (ST-410 SP15)
GI M-Clamps for Shackle Insulators
0.03 ACSR Conductor Weasel
16kN Polymer Shackle Insulators
Galvinized Nuts and Bolts.
Danger Plates with Clamps
Earthing complete by GI Rod 20 mm 2.5 mtr long through G.I Strip 25X3 mm in HT Lines
Anti-Climbing Device with Clamps
LT Line Spacers
Galvanised Stay Set with 50x8mm Stay Clamp, Guy insulator(2Nos.), Anchor plate (200x 200 x 6 mm), nut- bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS Stay Rod & 7/3.15 mm dia GI stranded wire complete
Painting of ST poles 9 mtrs long with one coat of Red oxide
Painting of ST poles 9 mtrs long with 2 coats of Aluminium paint
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for laying of HT line with Weasel Conductor at Mohalla Gleva W.No-4, Dhalper.
9 Mtr. Long ST Pole (ST-410 SP33)
GI V cross-arm with top Bracket including clamp
GI Channel X-arm including clamps and braces
0.03 ACSR Weasel conductor
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
11KV Pin Insulator (Polymeric) with Pins (12kv, 5KN) Creepage Distance 320mm
11KV Disc Insulators (Polymeric 45KN ) creepage distance 320 mm with tension fittings
Earthing complete by GI Rod 20 mm 2.5 mtr long through G.I Strip 25X3 mm in HT Lines
Painting of ST poles 9 mtrs long with 2 coats of Aluminium paint
Painting of ST poles 9 mtrs long with 2 coats of Aluminium paint
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Creation of 1 no. 25KVA Distribution Transformer at Mohalla Gleva W.No-4, Dhalper.
11/0.433kV, 3-phase 25KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor, 9 kV, 10 kA, LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical type
11 kV Horn Gap Fuse Set 3 Phase 200A
120 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Al Stranded Conductor FRLS type
9 Mtr. Long ST Pole (ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
LT Distribution box for 25 KVA DTR with MCCB
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip 50mmX 6mm for neutral earthing of size 32 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Cement bottoming of ST poles in 1:2:4 mix as per REC standards
Danger Plates with Clamps
Painting of Substation's ST Poles/cross arms/clamps with one coat of Red Oxide and two coats of Aluminium Paint
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for laying of LT line (3-phase, 4- wire) with Weasel Conductor at Mohalla Gleva W.No-4, Dhalper.
8 Mtr. Long ST Pole (ST-410 SP15)
GI M-Clamps for Shackle Insulators
0.03 ACSR Conductor Weasel
16kN Polymer Shackle Insulators
Galvinized Nuts and Bolts.
Danger Plates with Clamps
Earthing complete by GI Rod 20 mm 2.5 mtr long through G.I Strip 25X3 mm in HT Lines
Anti-Climbing Device with Clamps
LT Line Spacers
Galvanised Stay Set with 50x8mm Stay Clamp, Guy insulator(2Nos.), Anchor plate (200x 200 x 6 mm), nut- bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS Stay Rod & 7/3.15 mm dia GI stranded wire complete
Painting of ST poles 9 mtrs long with one coat of Red oxide
Painting of ST poles 9 mtrs long with 2 coats of Aluminium paint
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .