Loading…
Loading…
Tender Value
₹48.7 L
EMD Value
₹97,400
Closing Date
27 Jul 2026, 10:30 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
45 days
Expenditure
Capital (Works)
Above/Below/Par
GENERAL
34 conditions · 7 needing a document upload
GST : Tenderer has to fulfill GST Compliance as per Govt. norms
Performance Guarantee: (a)The successful bidder shall have to submit a Performance Guarantee (PG) within 21 (Twenty one) days from the date of issue of Letter of Acceptance (LOA). Extension of time for submission of PG beyond 21 (Twenty one) days and upto 60 days from the date of issue of LOA may be given by the Authority who is competent to sign the contract agreement. However, a penal interest of 12% per annum shall be charged for the delay beyond 21(Twenty one) days, i.e. from 22nd day after the date of issue of LOA. Further, if the 60thday happens to be a declared holiday in the concerned office of the Railway, submission of PG can be accepted on the next working day. In all other cases, if the Contractor fails to submit the requisite PG even after 60 days from the date of issue of LOA, the contract is liable to be terminated. In case contract is terminated railway shall be entitled to forfeit Bid Security and other dues payable to the contractor against that particular contract, subject to maximum of PG amount. In case a tenderer has not submitted Bid Security on the strength of their registration as a Startup recognized by Department of Industrial Policy and Promotion (DIPP) under Ministry of Commerce and Industry, DIPP shall be informed to this effect. The failed Contractor shall be debarred from participating in re-tender for that work. (b) The successful bidder shall submit the Performance Guarantee (PG) in any of the following forms, amounting to 5% of the original contract value:- (i) A deposit of Cash; (ii) Irrevocable Bank Guarantee; (iii) Government Securities including State Loan Bonds at 5% below the market value; (iv) Pay Orders and Demand Drafts tendered by any Scheduled Commercial Bank of India; (v) Guarantee Bonds executed or Deposits Receipts tendered by any Scheduled Commercial Bank of India; (vi) Deposit in the Post Office Saving Bank; (vii) Deposit in the National Savings Certificates; (viii) Twelve years National Defence Certificates; (ix) Ten years Defence Deposits; (x) National Defence Bonds and (xi) Unit Trust Certificates at 5% below market value or at the face value whichever is less. Also, FDR in favour of FA&CAO (free from any encumbrance) may be accepted.
The Performance Guarantee shall be submitted by the successful bidder after the Letter of Acceptance (LOA) has been issued, but before signing of the contract agreement. This P.G. shall be initially valid upto the stipulated date of completion plus 60 days beyond that. In case, the time for completion of work gets extended, the Contractor shall get the validity of P.G. extended to cover such extended time for completion of work plus 60 days. (d) The value of PG to be submitted by the Contractor is based on original contract value and shall not change due to subsequent variation(s) in the original contract value. (e) The Performance Guarantee (PG) shall be released after physical completion of the work based on 'Completion Certificate' issued by the competent authority stating that the Contractor has completed the work in all respects satisfactorily. (f) Whenever the contract is rescinded, the Performance Guarantee already submitted for the contract shall be encashed. (g) The Engineer shall not make a claim under the Performance Guarantee except for amounts to which the President of India is entitled under the contract (not withstanding and/or without prejudice to any other provisions in the contract agreement) in the event of: (i) Failure by the Contractor to extend the validity of the Performance Guarantee as described herein above, in which event the Engineer may claim the full amount of the Performance Guarantee. (ii) Failure by the Contractor to pay President of India any amount due, either as agreed by the Contractor or determined under any of the Clauses/Conditions of the Agreement, within 30 days of the service of notice to this effect by Engineer. (iii) The Contract being determined or rescinded under clause 62 of these conditions.
Security Deposit: The Security Deposit shall be 5% of the contract value. The Bid Security submitted by the Contractor with his tender will be retained/encashed by the Railways as part of security for the due and faithful fulfillment of the contract by the Contractor. Provided further that, if Contractor submits the Cash or Term Deposit Receipt issued from a Scheduled commercial bank of India or irrevocable Bank Guarantee Bond from a Scheduled commercial bank of India, either towards the Full Security Depositor the Part Security Deposit equal to or more than Bid Security, the Railway shall return the Bid Security, to the Contractor. Balance of Security Deposit may be deposited by the Contractor in cash or Term Deposit Receipt issued from Scheduled commercial bank of India or irrevocable Bank Guarantee bond issued from Scheduled commercial bank of India, or may be recovered at the rate of 6% of the bill amount till the full Security Deposit is recovered. Provided also that in case of defaulting Contractor, the Railway may retain any amount due for payment to the Contractor on the pending "on account bills" so that the amounts so retained (including amount guaranteed through Performance Guarantee) may not exceed 10% of the total value of the contract. The Irrevocable Bank Guarantee submitted towards Security deposit shall be initially valid up to the stipulated date of Maintenance period plus 60 days and shall be extended from time to time, depending upon extension of contract granted in terms of Clause 17A and 17B of the Standard General Conditions of Contract. Note: Security Deposit deposited in cash by the Contractor or recovered from the running bills of a Contractor or submitted by contractor as Term Deposit Receipt(s) can be refunded/returned to the contractor, in lieu of irrevocable Bank Guarantee bond issued from scheduled commercial bank of India, to be submitted by him, for an amount equal to or more than the already available Security Deposit, provided however that, in a contract of value less than Rs. 50 Crore, such refund/ return of the already available Security Deposit is permitted up to two times and in a contract of value equal to or more than Rs. 50 Crore, such refund / return of the already available Security Deposit is permitted up to three times.
Refund of Security Deposit: Security Deposit mentioned in sub clause (1) above shall be returned to the Contractor along with or after, the following: (a) Final Payment of the Contract as per clause 51.(1) and (b) Execution of Final Supplementary Agreement or Certification by Engineer that Railway has No Claim on Contractor and (c) Maintenance Certificate issued, on expiry of the maintenance period as per clause 50.(1), in case applicable. 16. (2) (ii) Forfeiture of Security Deposit: Whenever the contract is rescinded as a whole under clause 62 (1) of these conditions, the Security Deposit already with railways under the contract shall b e forfeited. However, in case the contract is rescinded in part or parts under clause 62 (1) of these conditions, the Security Deposit shall not be forfeited. 16.(3) No interest shall be payable upon the Bid Security and Security Deposit or amounts payable to the Contractor under the Contract, but Government Securities deposited in terms of SubClause 16.(4) (b) of this clause will be payable with interest accrued thereon.
Mandate form should be uploaded as per attached format in document tab.
Tenderer may upload GST registration number and certificate
PAN Card: Tenderers are required to upload their Permanent Account Number (PAN) card
Contact details of tenderer: The Contractor shall submit their complete official address, e-mail address, telephone no., mobile no. and fax no. so that necessary communication can be made by the Railways as and when required.
Employment/Partnership etc. of Retired Railway Employees: (a)Should a tenderer i) be a retired Engineer of the gazetted rankor any other gazetted officer working before his retirement, whether in the executive or administrative capacity or whether holding a pensionable post or not, in the Engineering or any other department of any of the railways owned and administered by the President of India for the time being, OR ii)being partnership firm / joint venture (JV) / registered society /registered trust etc have as one of its partners a retired Engineer of the gazetted rank or any other gazetted officer working before his retirement, OR iii) being an incorporated company have any such retired engineer of the gazetted rank or any other gazetted officer working before his retirement as one of its directors AND in case where such Engineer or officer had not retired from government service at least 1 year prior to the date of submission of the tender THEN the tenderer will give full information as to the date of retirement of such Engineer or gazetted officer from the said service and as to whether permission for taking such contract, or if the Contractor be a partnership firm or an incorporated company, to become a partner or director as the case may be, has been obtained by the tenderer o r the Engineer or officer, as the case may be from the President of India or any officer, duly authorized by him in this behalf, shall be clearly stated in writing at the time of submitting the tender. b) In case, upon successful award of contract, should a tenderer depute for execution of the works under or to deal matters related with this contract, any retired Engineer of gazette rank or retired gazetted officer working before his retirement in the Engineering or any other department of any of the railways owned and administered by the President of India for the time being, and now in his employment, then the tenderer will ensure that retired Engineer or retired gazetted officer had retired from government service at least 1 year prior to the date of his employment with tenderer and in case he had retired from service within a year then he possesses the requisite permission from the President of India or any officer, duly authorized by him in this behalf, to get associated with the tenderer . c) Should a tenderer or Contractor being an individual, have member(s) of his family or in the case of partnership firm/ company / joint venture (JV) / registered society / registered trust etc. one or more of partners(s)/shareholder(s) or member(s) of the family of partner(s)/ shareholder(s) having share of more than 1% in the tendering entity employed in gazetted capacity in the Engineering or any other department of the railway, then the tenderer at the time of submission of tender, will inform the authority inviting tenders the details of such persons. If information as required as per 16.a), b), c) above has not been furnished, contract is liable to be dealt in accordance with provision of clause 62 of Standard General Condition of contract. Format for declaration in this regard is attached with the tender document.
Mention status of firm: Individual Firm / Proprietorship Firm / Partnership Firm /Private Ltd. Firm / Public Ltd. Firm or Government Undertaking.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Shramikkalyan portal:- (i) Contractor is to abide by the provisions of various labour laws in terms of above clause 54,55, 55-A and 55-B of Indian Railways Standard General Conditions of Contract. In order to ensure the same, an application has been developed and hosted on website 'www.shramikkalyan.indianrailways.gov.in'. Contractor shall register his firm/company etc. and upload requisite details of labour and their payment inthis portal. These details shallbe available in public domain. The registration /updation in Portal shall be done as under: (a)Contractor shall apply for one time registration of his company/firm etc. in the Shramikkalyan portal with requisite details subsequent to issue of Letter of Acceptance. Engineer shall approve the contractor's registration in the portal within 7 days of receipt of such request. (b)Contractor once approved by any Engineer, can create password with login ID (PAN No.) for subsequent use of portal for all Letter of Acceptances (LoAs)issued in his favour. (c)The contractor once registered on the portal, shall provide details of his Letter of Acceptances (LoAs)/ Contract Agreements on shramikkalyan portal within 15 days of issue of any LoA for approval of concerned Engineer. Engineer shall update (if required) and approve the details of LoA filled by contractor within 7 days of receipt of such request. (d)After approval of LoA by Engineer, contractor shall fill the salient details of contract labours engaged in the contract and ensure updating ofeach wage payment to them on shramikkalyan portal on monthly basis. (e)It shall be mandatory upon the contractor to ensure correct and prompt uploading of all salient details of engaged contractual labour & payments made thereof after each wage period. (ii)While processing payment of any'On Account Bill' or 'Final Bill' or release of 'Advances' or 'Performance Guarantee / Security deposit', contractor shall submit a certificate to the Engineer or Engineer's representatives that "I have uploaded the correct details of contract labours engaged in connection with this contract and payments made to them during the wage period in Railway's Shramikkalyan portal at 'www.shramikkalyan.indianrailways.gov.in' till____Month,____Year.
Guarantee/Warrantee: The installation will be handed over to the Department after necessary testing and commissioning. The installation will be guaranteed against any defective design/ workman-ship. Similarly, the materials supplied by the contractor will be guaranteed against any manufacturing defect, inferior quality. The complete luminaire/LED bulb shall have replacement guarantee for satisfactory performance and manufacturing defects for a period of 60 months from the date of commissioning or 72 months from the date of supply whichever is earlier. For switch gear components and panels, warrantee should be 1year after date of installation , For all other items, the warrantee period will be for a period of 12 months from the date of handing over to the Department. Installation/ equipment or components thereof shall be rectified/repaired to the satisfaction of the Engineer-in-charge.
Please read all the documents before submission of Tender.
Any other reputed make/brand other than as specified in the explanatory note/Tender may be considered during execution of the works on an urgent basis, subject to technical suitability, conformity to relevant IS/IEC standards, and approval of the Competent Authority. Where the specified BEE star rating is not manufactured/available for the required capacity the highest available BEE star rating at the time of procurement shall be accepted against submission of OEM documentary evidence and approval of the Competent Authority. Any such change shall be made without any additional financial implication to the Railway unless otherwise specifically approved by the Competent Authority.
Electrical work for Construction of 02 Nos of Inspection Pit of length 66 mtrs with cover shed, Administrative building, A Loco Stabling line along with OHE wiring for Electric loco Trip Shed at SHM.
Elect-Chg-26-27-ELSSHM-11
Elect-Chg-26-27-ELSSHM-11
Open
Works - General
12 Months
Howrah, West Bengal
₹0
₹97,400
27 Jul 2026
2 Jul 2026
13 Jul 2026
164 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 39,44,460.75 | ||
| — | 22.00 | — | — | ||
| Supply of 20W or higher wattage LED tube light with Batten ( integrated electronic driver).As per CEGE approved Specification for LED tube light-high power,2100 Lumen output,220V, 50Hz AC with constant current driver with short circuit and overload protection etc. | — | — | — | 7,439.08 | |
| — | 22.00 | — | — | ||
| Fixing and Commissioning of 20W or higher wattage LED tube light with Batten. | — | — | — | 892.98 | |
| — | 4.00 | — | — | ||
| Supply of LED Street light fittings 45W LED, LED chip Efficacy 130 Lm/Watt, IP-66.as per HQ specification. | — | — | — | 6,000 | |
| — | 4.00 | — | — | ||
| Fixing and commissioning of LED Street light fittings45 W LED, IP-66. | — | — | — | 600 | |
| — | 2.00 | — | — | ||
| Supply Fixing and commissioning of self-priming Monoblock pump complete set 5HP, 3-Phase, suction 80 mm Cap: 17.4 Ltrs per Sec. at 10 Mtr height. Similar to Pump model No. (SP+B35LM+3PH), HSN Code: 8413. | — | — | — | 58,000 | |
| — | 2.00 | — | — | ||
| Supply, Fixing and commissioning of 3PH DOL Starter. Suitable for operation in 400V, 50Hz | — | — | — | 3,389.84 | |
| — | 2.00 | — | — | ||
| Supply of SP&N 12-way DB (SD) Thermoplastic Circuit breaker boxes IP 65 (with metric knockouts for cable entry)consisting with DP 32A 10kA MCB-1 no as incoming and SP 20 A,10kA MCB - 4 nos, SP 16 A,10kA MCB - 4 nos, as outgoing with Neutral links and Earth bar etc., Make: Any IS approved. | — | — | — | 19,878.3 | |
| — | 2.00 | — | — | ||
| Fixing and Commisioning of SP&N 12-way DB (SD) Thermoplastic Circuit breaker boxes IP 65 (with metric knockouts for cable entry)consisting with DP 32A 10kA MCB-1 no as incoming and SP 20 A,10kA MCB - 4 nos, SP 16 A,10kA MCB - 4 nos, as outgoing with Neutral links and Earth bar etc. | — | — | — | 853.06 | |
| — | 2.00 | — | — | ||
| Supply of VTP&N 4-way DB (Mettalic Door) with FP 100A,35KA MCCB -01no as incoming and FP 63A,25KA MCCB -01no,40Amps,10kA DP MCB-01no,16Amps,10kA DP MCB-01no as outgoing with bus-bar, Neutral links and Earth bar etc.,with proper wiring to complete job. | — | — | — | 28,395.46 | |
| — | 2.00 | — | — | ||
| Fixing and Commissioning VTP&N 4-way DB (Metallic Door) with FP 100A,35KA MCCB -01no as incoming and FP 63A,25KA MCCB -01no,40Amps,10kA DP MCB-01no,16Amps,10kA DP MCB-01no as outgoing with bus-bar, Neutral links and Earth bar etc,with proper wiring and accessories to complete job as per site requirement. | — | — | — | 1,091.36 | |
| — | 2.00 | — | — | ||
| Supply and Testing of OEM TTA Distribution panel, consisting of Incoming- MCCB 4P 250 A Qty -01, Outgoing -i) MCCB 4P 100 A Qty -02, ii) MCCB 4P 63 A Qty - 01, iii) MCB 2P 40 A Qty - 04, iv) MCB 2P 32 A Qty- 02 with suitable TPN 250 A copper busbar, indication lights, suitable spreader link, contactor with all modern facilities required for scada, volt meter, amp meter energy meter time switches etc. Panel should be as per IEC 61439 or latest. | — | — | — | 4,66,000 | |
| — | 2.00 | — | — | ||
| Erection, Installation and commissioning of TTA make Distribution panel . including civil job. | — | — | — | 69,027.4 | |
| — | 150.00 | — | — | ||
| Point Wiring by PVC conduit /PVC Casing & Capping : -- Internal wiring for light, fan , plug points and night lamp points by 1.5 sq. mm, Single Core, Multistrand (22/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type-C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked. Earthing the point with 1.5 sq. mm, Single Core, Multistrand (22/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR- LSH), PVC insulated Cable of 1100V grade, Type-C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark. or PVC Casing & capping, ISI marked, white color, double locking, Resistant to Flame Propagation to grade UL-94 V0, as per IS:14927 Part 2 : 2001 (Reaffirmed Year : 2017 ) or latest, Standard Length: 2 meter, Size: 25x16mm. including Modular Electrical Switch, 6 A, 230 V, SP, 1 Way, 1 Module, Unenclosed type as per Clause no.7.1.3, Method of Activation of switch shall be of Rocker type as per Clause no. 7.1.5, Switch shall be Flush type as per Clause no.7.1.6 and shall be installed as per Design A mentioned in the Clause no.7.1.7, Current carrying material as per Clause no. 22.5, with cover made of tough non-ignitable insulating material and bare of tough non-ignitable insulating material or of vitrified ceramic material, Conforming to IS:3854/1997 (reaffirmed 2017) with latest amendments and ISI mark., including supply of all required materials like lamp holder, Aluminium, batten type, with shade carrier ring,ISI marked, Base: B-22 suitable for use at 250V, Conforming to IS: 1258(Rev.-3)-2005)with amdt-3. With BACK plate of 53 MM. Dia & 45 MM PCD.., ceiling rose, Modular type Socket outlet suitable for 3 pin plug, 6A, 230V, 2 Module, Shuttered (Operation of Shutter should be independant of Earthing Point), Cover made of tough Non-Ignitable insulating material, material of base -vitrified ceramic, Conforming to IS : 1293-2019, Amendment no. 1 or latest with ISI mark ,suitable PVC modular JB box ,switch Board, Spacers, Saddles, Bends, Tees to be provided as and where required as per direction of consignee,. Provision of moduler fan regulator should be kept on switch board .The plate should include 2 blank space for further installation of switches.including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available. The cost includes supply of all materials to complete job. ( Two 5-ampere socket point treated as one point). | — | — | — | 1,04,238 | |
| — | 400.00 | — | — | ||
| Circuit/Sub-circuit wiring by PVC conduit/PVC casing capping wiring by 2.5 sq. mm, Single Core, Multistrand (36/0.3mm), Copper Conductor(flexible), Unsheathed, Flame Retardant Low Smoke and Halogen (FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS: 694-2010(reaffirmed 2020), ISI marked.Continuous Earthing with 2.5 sq. mm, Single Core, Multistrand (36/0.3mm), Copper Conductor(flexible), Unsheathed, Flame Retardant Low Smoke and Halogen (FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS: 694-2010(reaffirmed 2020), ISI marked through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark. or PVC Casing & capping, ISI marked, white color, double locking, Resistant to Flame Propagation to grade UL-94 V0, as per IS:14927 Part 2 : 2001 (Reaffirmed Year : 2017 ) or latest, Standard Length: 2 meter, Size: 25x16mm. to be provided as and where required as per direction of consignee including PVC Circular Box and Ceiling rose if required with connection from running circuit as per direction of Consignee,stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.The cost includes supply of all materials to complete job. *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable of size 2.5 sq mm for phase & neutal and 1mtr of 2.5 Sq.mm PVC Cu. cable for earthing with Supply of PVC Circular Box and Ceiling rose as per direction of Consignee. | — | — | — | 1,27,340 | |
| — | 150.00 | — | — | ||
| Circuit/Sub-circuit wiring by PVC conduit/PVC casing capping wiring by 4 sq. mm, Single Core, Multistrand (56/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked.Continuous Earthing with 4 sq. mm, Single Core, Multistrand (56/0.3mm), Copper Conductor (flexible), Unsheathed, Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked Cable through PVC Conduit Pipe of Nominal Size 25mm and in the length of 3 mtrs, Socket ended (at one end ), medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark. or PVC Casing & capping, ISI marked, white color, double locking, Resistant to Flame Propagation to grade UL-94 V0, as per IS:14927 Part 2 : 2001 (Reaffirmed Year : 2017 ) or latest, Standard Length: 2 meter, Size: 25x16mm. to be provided as and where required as per direction of consignee including PVC Circular Box and Ceiling rose if required with connection from running circuit as per direction of Consignee,stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available.The cost includes supply of all materials to complete job. *Quantity per meter means-one meter conduit with 2 (two) meters Cu. cable of size 4 sq mm for phase & neutral and 1mtr of 4 Sq.mm PVC Cu. cable for earthing with Supply of PVC Circular Box and Ceiling rose as per direction of Consignee. | — | — | — | 57,996 | |
| — | 300.00 | — | — | ||
| Shelter wiring by 2.5 sq mm PVC Cu wire through PVC conduit 32 mm dia (1 mtr length means 8 Nos 2.5 sq mm PVC Cu wire and 01 No 2.5 sq mm Cu wire for eathing 02 Nos PVCconduit pipe cable should be Single Core, Multistrand (84/0.3mm), Copper Conductor (flexible), Unsheathed, , Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked.Continuous Earthing with 2.5 sq. mm, Single Core, Multistrand (84/0.3mm), Copper Conductor (flexible), Unsheathed, , Flame Retardant Low Smoke and Halogen(FR-LSH), PVC insulated Cable of 1100V grade, Type C PVC Compound as per IS 5831, Conforming to IS :694 - 2010 (Reaffirmed 2020), ISI marked Cable through PVC Conduit Pipe of Nominal Size 32mm medium mechanical stress, White Color, Resistant to Flame Propagation to grade UL-94 V0, Conforming to IS 9537 (Part 3) 1983 (Reaffirmed Year : 2017) with amendment no. 2 or latest with ISI mark. or PVC Casing & capping, ISI marked, white color, double locking, Resistant to Flame Propagation to grade UL-94 V0, as per IS:14927 Part 2 : 2001 (Reaffirmed Year : 2017 ) or latest, to be provided as and where required as per direction of consignee including PVC Circular Box and Ceiling rose if required with connection from running circuit as per direction of Consignee,stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. All materilas would be as per latest specification as issued from HQ/GRC time to time if available or latest IS and IE rules which is available. The cost includes supply of all materials to complete job. | — | — | — | 1,62,000 | |
| — | 10.00 | — | — | ||
| Supply of 3 modular plate and metal/pvc box with 6A/16A twin socket Shutter type and 16 or 20A switch. All item will be modular type and separate (as per PCEE specification no.CEE/P/56/301 /MAINTENANCE, Dtd. 17/11/2022.) | — | — | — | 4,999.4 | |
| — | 10.00 | — | — | ||
| Fixing and commissioning of 3 modular plate and metal/pvc box with 6A/16A twin socket Shutter type and 16 or 20A switch. All item will be modular type and separate. (Wiring will be covered under Schedule item No.14 as per site requirement). | — | — | — | 269.5 | |
| — | 5.00 | — | — | ||
| Supply of modular PC Board consisting of 03 nos. switches with inbuilt LED indication, 03 nos. sockets and modular SP MCB 10A, 10kA, Type B- 01 No. with Stainless Steel 12M Box and all other accessories to complete job for concealed wiring. Specs: Modular Electrical Switch, 6 A, 230 V, SP, 1 Way, 1 Module, Unenclosed type as per Clause no.7.1.3, Method of Activation of switch shall be of Rocker type as per Clause no. 7.1.5, Switch shall be Flush type as per Clause no.7.1.6 and shall be installed as per Design A mentioned in the Clause no.7.1.7, Current carrying material as per Clause no. 22.5, with cover made of tough non-ignitable insulating material and bare of tough non-ignitable insulating material or of vitrified ceramic material, Conforming to IS:3854/1997 (reaffirmed 2017) with latest amendments and ISI mark and Modular type Socket outlet suitable for 3 pin plug, 6A, 230V, 2 Module, Shuttered (Operation of Shutter should be independant of Earthing Point), Cover made of tough Non-Ignitable insulating material, material of base -vitrified ceramic, Conforming to IS : 1293-2019, Amendment no. 1 or latest with ISI mark. with modular SP MCB 10A, 10kA, Type B- 01 No. ISI marked, rated voltage: 240V AC, conforming to IS/IEC 60898-1:2015 (Reaffirmed Year:2024) or latest, with rated short circuit current capacity 10KA, fixed unadjustable time current characteristics suitable for use in protection of industrial, commercial and domestic electrical installations. along with 12M stainless steel Box, moduler cover plate and Stainless Steel boxes and all other accessories including stainless steel fastener, Pin Type Terminal End Lugs to complete job as per specification attached or with latest amendment or specification issued from HQ/GRC if any time to time. | — | — | — | 7,199.95 | |
| — | 5.00 | — | — | ||
| Fixing and commissioning of modular PC Board consisting of 03 nos. switches with inbuilt LED indication, 03 nos. sockets and modular SP MCB 10A, 10kA, Type B- 01 No. with Stainless Steel 12M Box, moduler cover plate duly Concealed in wall surface including all other accessories to complete job with latest amendment or specification issued from HQ/GRC if any time to time, including stainless steel fastener, Pin Type Terminal End Lugs as per specification attached. (Wiring will be covered under Schedule item No. as per site requirement). | — | — | — | 110.95 | |
| — | 200.00 | — | — | ||
| Supply of L.T. Aluminium Armoured PVC XLPE cable of size 4 Core x400 Sq mm 1100 Volts Grade. IS No. 7098-Part-1, 1988, with amendment No. 1 and 2 and 3 reaffirmed 2005. | — | — | — | 2,97,120 | |
| — | 200.00 | — | — | ||
| Supply of L.T. Aluminium Armoured PVC XLPE cable of size 4 Core x 120 Sq mm 1100 Volts Grade. IS No. 7098-Part-1, 1988, with amendment No. 1 and 2 and 3 reaffirmed 2005. | — | — | — | 2,07,458 | |
| — | 200.00 | — | — | ||
| Supply of L.T. Aluminium Armoured PVC XLPE cable of size 4 Core x 35 Sq mm 1100 Volts Grade. IS No. 7098-Part-1, 1988, with amendment No. 1 and 2 and 3 reaffirmed 2005. | — | — | — | 47,458 | |
| — | 3.00 | — | — | ||
| Transportation of cables in rolls with or without wooden drums from the store of concerned SSEE or any store of SRC to the site of works. | — | — | — | 2,874.15 | |
| — | 500.00 | — | — | ||
| Laying of cable/ cables in under ground along the road through cable trench etc . as per standard drawing including necessary termination , connection and testing.Trenching and laying of U/G cables in any kind of soil trench of size minimum 0.40 mtr wide and 1 mtr deep covered with necessary bricks for protection of the cables including filling of space between brick and cable/cables with sand and refilling the trench with excavated soil, leveling up, and restoring the surface duly rammed. | — | — | — | 54,530 | |
| — | 50.00 | — | — | ||
| Laying of cable/ cables across the road, track, drain etc through RCC/GI pipe confirming to IS standard of size 100mm or 150mm (or any suitable size as per field requirement based on the actual size of the cable) as per relevant specification and as per standard drawing with necessary termination, connections and testing .Cost also includes collection of cable/cables from Railway store if required.GI pipe will be supplied by contractor. | — | — | — | 12,482.5 | |
| — | 50.00 | — | — | ||
| Laying of cable/ cables on wall / structure through PVC casing pipe of size 4inches or 3inches with accessories or as per site requirement with suitable clamp / saddle/ fixtures etc with necessary termination, connection and testing as per standard drawing.Cost also includes collection of cable/cables from Railway store if required. | — | — | — | 3,750 | |
| — | 50.00 | — | — | ||
| Supply of HDPE pipe of size 110 mm Diameter PE 100 to complete job. | — | — | — | 11,229 | |
| — | 50.00 | — | — | ||
| Erection and commissioning of HDPE pipe with all accessories to complete job. | — | — | — | 1,737 | |
| — | 80.00 | — | — | ||
| Supply of Hot dipped Galvanized CABLOFIL wire mesh cable trays size: 54mm/200mm with coupling kit and other accessories. It shall be manufactured with a longitudinal 'T- welded' safety edge All Accessories including couplers , mounting accessories (Mechanically tested & supplied by cable tray manufacturer must be used) are required of same finish as per site requirement. Trays should comply Standard EN ISO 14 61: at least 550 h of SST. The deflection of cable tray must be no more than 1/200th of the distance between two supports and tested in accordance with the standard IEC 61537. Wire-mesh cable trays must be designed with an optimum span of 1.5 m, considering the maximum carrying capacity authorized by the manufacturer. Assemblies with specific fire resistant properties must have an E30-E90 certificate. Rod-dia must be from 3.9mm to5.9mm for different sizes. | — | — | — | 1,02,400 | |
| — | 80.00 | — | — | ||
| Fixing and commissioning of Hot dipped Galvanized CABLOFIL wire mesh cable trays size: 54mm/200mm with coupling kit and other accessories. | — | — | — | 3,849.6 | |
| — | 15.00 | — | — | ||
| Supply of POLYCARBONATE make fire retardent Cable loop box ( of fibre body), IP 66 Fixing shall be made with necessary arrangements as per site requirement, cables are to be terminated with proper socketing arrangement to complete job. | — | — | — | 18,622.95 | |
| — | 15.00 | — | — | ||
| Fixing and commissioning of POLYCARBONATE make fire retardent Cable loop box ( of fibre body), IP 66 Fixing shall be made with necessary arrangements as per site requirement, cables are to be terminated with proper socketing arrangement to complete job. | — | — | — | 1,862.25 | |
| — | 6.00 | — | — | ||
| Supply of Pedestal type Heavy Duty Air Circulated Fan sweep 600mm, single phase. | — | — | — | 35,588.16 | |
| — | 2.00 | — | — | ||
| Supply of Analog Time Switches for Tower Light, Pump Installations & Street Light Circuits etc. Floor/Panel/Tower/Wall mounted ,Supply Voltage 240V AC,50/60HZ,with DP 32A power contractor and 32A,10kA DP MCB-01no with SS enclosure with proper wiring to complete job. | — | — | — | 3,238.1 | |
| — | 2.00 | — | — | ||
| Fixng and Commissioning of Analog Time Switches for Tower Light, Pump Installations & Street Light Circuits etc. Floor/Panel/ Tower/Wall mounted ,Supply Voltage 240V AC,50/60HZ,with DP 32A power contractor and 32A,10kA DP MCB-01no with SS enclosure with proper wiring to complete job. | — | — | — | 911.22 | |
| — | 1.00 | — | — | ||
| Supply of Aluminium Tilt Table Tower Ladder for high bay light maintenance purpose with minimum working ht: 35 Ft, Extendended Ht 33 ft, closing height 18 ft , tilting Ht 8 ft approximately. | — | — | — | 1,17,388.98 | |
| — | 8.00 | — | — | ||
| Supply of Earthing arrangement with supply of Hot Dip Galvanized (HDG) earth cone and all other requisite materials as per CEE/GRC's Drg. No.CEE/G/A3/P-150, Alt.1 including sump box with salt and charcoal, metallic cover etc. as per site supervisor's instruction. Cost includes supply of all materials mentioned in the Drawing including 02 mtrs 25x5mm GI strip for connection from earth electrode pipe to light pole /Rail pole etc.Make: Any IS standard Indian make. | — | — | — | 29,401.04 | |
| — | 8.00 | — | — | ||
| Erection of Earthing arrangement with erection of Hot Dip Galvanized (HDG) earth cone and all other requisite materials as per CEE/GRC's Drg. No.CEE/G/A3/P-150, Alt.1 including sump box with salt and charcoal, metallic cover etc. as per site supervisor's instruction. Cost includes erection of all materials mentioned in the Drawing including 02 mtrs 25x5mm GI strip for connection from earth electrode pipe to light pole /Rail pole etc. | — | — | — | 7,052.24 | |
| — | 6.00 | — | — | ||
| Supply of heavy duty Wall Mounted Fan WITH 5 STAR and above RATING 600 mm size , suitable for 230V, 50Hz, AC supply as per site requirement. | — | — | — | 56,186.46 | |
| — | 6.00 | — | — | ||
| Fixing and Commissioning of Wall Mounted Fan WITH 5 STAR and above RATING 600mm size with all accessories, as per site requirement. | — | — | — | 2,809.32 | |
| — | 10.00 | — | — | ||
| Supply of wall mounting type /pole mount type junction box(JB) made of polycarbonate (pc) of size should not be less than 330mmx330mmx130mm should have degree ingress protection ip 65 in accordance with iec 60529. The JB shall have the polyamide locking screw with internal polyamide hinge which should interchanged to both side for opening the enclosure easily from left to right or right to left as per the site condition .the JB shall be suitable to perform under ambient temperature -25deg c up to +85 degc & should be able to resist isolated tension 1000v . The JB shall be halogen &silicon free, fire retardant & self extinguishing the combustion behaviour shall be in accordance with de 0471/ul94 for 960degc . The JB shall be uv resistance according to ul 746. Routine test report to be submitted. with following switch gear and terminals fixed in the junction box. Incoming : 1) 50sqmm stud type terminal block -04 nos 2) 6 sqmm /40A terminal block -02 nos, 3) 20mmx10mm x 75 mm length tinned copper bus bar for earth and neutral each 1 no to be fixed in the box. | — | — | — | 48,030 | |
| — | 10.00 | — | — | ||
| Fixing and commissioning wall mounting type /pole mount type junction box (jb) made of polycarbonate (pc) of size . | — | — | — | 696.2 | |
| — | 2.00 | — | — | ||
| Supply of Industrial type Socket 3 phase 5 pin, (3P+1N+1E) 125Amp IP 67 with mechanical interlocking and plug 125 amp 3P + N + E water tight IP 67(similar to hensel cat no 9755100 and 045-6). | — | — | — | 1,82,280 | |
| — | 2.00 | — | — | ||
| Installation & commissioning of Industrial type Socket and plug with all accessories. | — | — | — | 1,196.64 | |
| — | 3.00 | — | — | ||
| Supply of Industrial type Socket 3 phase 5 pin, (3P+1N+1E) 63Amp IP 67 with mechanical interlocking and plug 63 amp 3P + N + E water tight IP 67(similar to hensel cat no 75352-6 and 035-6), | — | — | — | 90,300 | |
| — | 3.00 | — | — | ||
| Installation & commissioning of Industrial type Socket and plug with all accessories. | — | — | — | 1,794.96 | |
| — | 20.00 | — | — | ||
| Supply, of LED High Bay light fittings 200W LED, LED chip Efficacy (Lumen/watt) 130, Luminaire System Efficacy - Lumen output - (Lumen/watt) 120, 6000 K IP-65, IK 07. Accessories for each luminaire: Metallic adjustable Brackets (Stainless steel),SS Eye Bolts (as per IS:4190:1984 latest),Set of Bolt, Nut, Washers (SS),Die cast aluminium brackets etc. ISI Marked 3 Core cable for input power ( min Length:250 mm ).Test report from NABL lab to be submitted Warranty period (in Months) 36 or more. . | — | — | — | 5,25,423.8 | |
| — | 20.00 | — | — | ||
| Fixing and commissioning of LED High Bay light fittings. | — | — | — | 5,977.4 | |
| — | 66.00 | — | — | ||
| Supply, of LED light Fitting 22 watt, 48V of standard size along with LED light confirming with IP 67 & IK 10 water & dust proof for pit light, as per CAMTECH. By engraving the pit wall. a suitable metallic net to be provided over the light. The light must remain inside the pit wall surface. | — | — | — | 1,81,500 | |
| — | 66.00 | — | — | ||
| Fixing and commissioning of LED pit light fittings 48 volt AC/ 16 watt, IP 67 & IK 10 for pit lighting and catwork. | — | — | — | 11,433.18 | |
| — | 12.00 | — | — | ||
| Supply, of rain proof outdoor type step down transformer capacity 3 KVA, 230/48V50 HZ ac with MCB 32 A DP on incoming side with TPN-1, 4-way suitable cable connector of suitable size, withneutral point and 6x10 AMPS HRC Fuse for 6 nos. outgoing circuits. all complete assemble in 1mm thick CRCA steel sheets metal box with internally embedded gasket. erection to be done in girder or wall as per site requirement for pitlight. | — | — | — | 1,38,000 | |
| — | 12.00 | — | — | ||
| Erection, testing and Commissioning Rain proof Low voltage step down with copper wound Transformer 2KVA,230 /48 volt , 50 hz, AC with MCB (DP) of 32amps all complete assembly in a sheet metal box with internally embedded gasket. for pit lighting system. | — | — | — | 12,460.92 | |
| — | — | — | 6,01,697.4 | ||
| — | GST @ 18% | on Sub-Total on Schedule | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
2.0ExplanatorynotePitELSSHM.pdf
ATTACHMENT
GCC-2022_POLICY_27_04_22.pdf
ATTACHMENT
LEDSpecificationScan_compressed.pdf
ATTACHMENT
cablespec.pdf
ATTACHMENT
JPOfordiggnigwork.pdf
ATTACHMENT
JPOforconcealedwiring.pdf
ATTACHMENT
MANDATEFORM.pdf
ATTACHMENT
RAILWAYEMPLOYMENTCERTIFICATE.pdf
ATTACHMENT
GeneralConditions_1.pdf
ATTACHMENT
allcorrectionslipsmergedupto11compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .