| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | L1 | Accepted-AOC DUE TO L1 | |
| 2 | L2₹15.3 L+₹81,211.50 (5.61%)Rejected-AOC NEAR CIVIL HOSPITAL WARD NO 07 VPO CHOWARI DISTT CHAMBA HP 176302 | CHOWARI | CHAMBA | HP | 176302 | L2 | Rejected-AOC DUE TO L2 | |
| 3 | L3₹15.8 L+₹1.3 L (9.07%)Rejected-AOC VPO BAILLY TEHSIL DALHOUSIE DISTT CHAMBA HP PIN 176303 | CHAMBA | HIMACHAL PRADESH | 176303 | L3 | Rejected-AOC DUE TO L3 | |
| 4 | Rejected-Technical 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | - | Rejected-Technical DUE TO NO IN WLR |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
19 Nov 2020, 6:00 pmClosed
CWE YOL CANTT
HQ CWE YOL CANTT
SPECIAL REPAIR TO BLDG NO T-46 (OR ACCN) AT MANKOT LINE UNDER AGE (I) DALHOUSIE
2020_MES_386100_1
CWE/Y-109/2020-21
Open Tender
Civil Works
Works
180 days
DALHOUSIE
AS PER NIT
8 documents required · 8 mandatory
₹500
AGE (I) Dalhousie
₹38,000
29 Jan 2021
24 Oct 2020
20 Nov 2020
24 Oct 2020
19 Nov 2020
7 Nov 2020
Amount
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Demolition of brick work or stonework or precast concrete articles and precast concrete block walling ,built in cement mortar including all quoins, arches pillars etc but excluding ashlar facings ,dressed stonework and precast concrete articles and stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Taking down cement plaster including backing etc from brick/stone walls / concrete surfaces including raking out joints, hacking for key , scrubbing down with water etc complete all as specified and directed
Taking down chowkats with shutters (without taking off shutters from chowkat) exc 1.50 Sqm but not exc 4.00 Sqm each complete all as specified and directed. .
Dismantling timber in scantling 40 sqcm and over in section framed work complete all as specified and directed.
Demolition of wall and ceiling boards any thickness including cover fillets complete all as specified and directed.
Dismantling plain or corrugated steel sheets any gauge thickness including Nanital or similar pattern roof covering including ridges complete all as specified and directed.
PCC 1:3:6 (nominal mix) type C-1 (using 20mm graded crushed stone aggregates) as in hold fast block and similar work including use and waste of necessary form work complete all as specified and directed.
Brick work with old size fly ash bricks, class 7.5, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:6 (01 cement : 06 coarse sand) all as specified & directed.
2nd class hardwood (Sal) plain solid straight chowkats and frames wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed
40mm thick second class hardwood (Sal/Hollock) factory made plain framed panelled shutter (two panel) with lock rails & panel of 9 mm B.W.P commercial ply wood or 12 mm thick veneered particle board with commercial veneering on both side. The size of rail and stile as per IS:1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
35 mm thick 2nd class hard wood (Sal/Hollock)) glazed & skeleton factory made shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass, etc, sizes of members of shutters as specified in SSR- 2009 Part-I Section 8.24(a) complete all as specified and directed.
300mm long aluminium alloy, anodized, sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
Aluminium handles cast type anodized of size 150 mm complete all as specified and directed.
Aluminium anodized barrel tower bolt of extruded section of size 150 mm and fixed complete all as specified and directed.
300 mm long, ordinary mild steel rat tail rod pattern spring including roller and roller plate complete all as specified and directed.
Mild steel butt hinges of size 100 mm medium weight cold rolled complete all as specified and directed.
Galvanished mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanished wire staples, fixed in repair complete all as specified and directed.
Sheet glass, 3 mm thick ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed.
Sheet glass, 3 mm thick ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm each pane, fixed in repair, complete all as specified and directed.
4 mm thick non asbestos fibre cement building boards as in ceiling fixed or laid/ inserted to timber/ GI/ aluminium frame work fixed with nails, all as specified.
2nd class hard wood as in wood boarding, 20mm thick, clean sawn, secured with screws, fixed in roof, complete all as specified & directed.
2nd class hard wood wrought timber, framed and fixed as in scantling complete all as specified and directed.
Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed.
Prepainted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge, hips, valley/ eaves/ rain water gutters, drip and straight flashing (length and girth as fixed), fixed with self tapping screws all as specified
Mild steel work as in framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
Mild steel work as in hold fast, wind ties for roof including securing bolts including all necessary drilling ,bolting or reverting etc and all similar work conforming to Fe-290 (Gde E-165) complete all as specified and directed.
40 mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates) as in floor finish, surface finished even and smooth without using extra cement complete all as specified and directed.
Mat finish, premium quality, joint free (edge cut), coloured/ printed ceramic tiles 10 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed.
Machine cut kota stone slab flooring 18-20 mm thick of size not less than 550 mm X 550 mm including white marble border line 75mm wide, as per sample kept in GE’s office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, as in floor etc, laid over and including 15mm screed layer in cement mortar 1:4 (1 cement : 4 coarse sand), cutting, rubbing, grinding and polishing to achieve mirror finish, laid over PCC subbase complete, all as specified.
Chequered cement concrete coloured tiles, homogenious texture glossy finished , chemically coated machine pressed 30 cm x 30cm x 25mm thick set, jointed and pointed in near cement slurry in floor with gray cement and pigment and including 20 mm thick cement screed in cement mortar 1:4 over and including 75mm thick PCC M-10 (Nominal Mix) type C-2, using 40mm graded crushed stone aggregate complete all as specified and directed. Shade/Colour of tile shall be approved by the GE.
Rendering cement plaster 15mm thick in cement mortar 1:6 (1 cement : 6 coarse sand) in two layers (10mm thick first layer and 5mm thick second layer) on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.
Rendering cement plaster 15mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers (10mm thick first layer and 5mm thick second layer) on stone masonry or surface other than fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.
Preparation of steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Preparation of old steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
Preparing surfaces of wood & wood based surfaces new or old of any description and girth not otherwise described and treated with two coats of creosote oil complete all as specified and directed.
Preparation of old painted wooden surfaces of any description and applying one coat of synthetic enamel paint complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer over and including 3mm thick wall care putty (applied in two layers), finished smooth with sand paper complete all as specified and directed.
Preparation of new plastered surfaces or un plastered, previously undecorated wall surfaces and applying two coats of cement base paint, complete all as specified and directed.
Preparation of plastered or un-plastered, old surfaces of walls and applying one coat of cement base paint, complete all as specified and directed.
Taking down point wiring with aluminium/ copper conductor for light point, socket point/ power point etc. in PVC casing and caping, surface pvc/ steel conduits, wood batten with clips including taking down board any type and size complete with any type of switches, sockets, holders, (batten or pendent type), ceiling rose etc. The light fittings (any type), main switches, distribution board with MCB’s of any capacity and make are to be removed/ replaced if required and all as specified and directed. NOTE: - Existing fan regulator any type (Where required) and electric meters are to be refixed and connected properly where required.
Point wiring with 1.5 Sqmm copper conductor FRLS (Multistrand) PVC insulated ISI Marked unsheathed cable in and including PVC concealed (concealed wiring) conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marking, medium grade, ISI marked with all fittings/ accessories as specified in preamble 1 (a) to (q) of Section 19 of SSR Part-II, under heading point wiring, cutting chases, making good in cement mortar in CM (1:3), finishing surfaces to match with existing and also including PVC insulated ISI marked unsheathed 1.5 Sqmm copper multistranded conductor FLRS as earth wire (green colour) connected to common earth dolly for modular fitting, modular box sunk for mounting of switches, sockets, fan regulators, light fittings etc. covered with 3mm thick plastic laminated sheet (Make Hylum or equivalent ISI marked) for one light point or one fan point through regulator or one bell point, controlled by one way switch/ push button complete all as specified and directed.
All as per serial item No '42' above, but for one 3 pin 5 Amps socket outlet on the same board all as specified and directed.
All as per serial item No '42' above, but for one 3 pin 5 Amps socket outlet, independent all as specified and directed.
All as per serial item No. '42' above but for 3 pin 15 Amps socket out let independent with 2.5 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified.
Switch piano flush type, single pole, one way, 5 Amps, all as specified.
Switch piano flush type, single pole, one way, 15 Amps, all as specified.
Socket outlet two & three pin 5 Amp flush type, all as specified.
Socket outlet, two and three pin, 5 Pin, 5/16 Amp flush type controlled by one switch, all as specified.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings , all as specified.
Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified.
LED lamps, 10 watts all as specified and directed. Make:- CAT Part No LHLDERUEML8X010 of make "Havells" or equivalent in makes mentioned in Appendix "C".
Renewal of wall mounted LED integrating batten fitting T5, 20 Watt LED, 4 feet, PVC extruded with 20 watt LED tube rod with all acessoreis prewired and making connection with 3 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light complete. Havell's Cat Part No. LHEBTP7UN1W018/ C&S cat pART nO LTTB4F20WLEDP/W/ Philips CAT Part No BN021LED20S-6500 NW PSU GR or equivalent in makes mentioned in Appx 'C'.
Renewal of bulk head LED light fitting, 10 Watts with deep drawn anodised aluminium body, epoxy white powder coated, heat resistant prismatic glass cover with specially designed glass cover with 10 watts LED lamp with all acessoreis prewired and making connection with 3 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light complete. Make :Crompton Greaves Cat Part No. CG80IB10WLEDor equivalent in makes mentioned in Appx 'C'.
Building street light luminaire, LED street light 30 watt IP-66 powder coated pressure die cast aluminium compact high power LED street light with heat re4sistance toughened glass. Make:- crompton Cat Part No. LSTS-30-CDL or equivalent in makes mentioned in Appx 'C'.
Supply and fixing in replacement street light Bracket of GI pipe 40mm dia medium grade of length 1.80m and fixed with clamps made out of 25 X 4 mm with nuts and bolts, complete all as specifed & directed.
Cutting into existing road in required width in any condition for laying cable through pipe and making good the disturbed surfaces to match with existing using PCC M-15, type B-I with 20 mm graded crushed stone aggregate including removing surplus material to a distance not exc 50 metres from starting point, complete and as directed.
Cutting/ grooving in plinth protection/ wall/ verandah in any condition for laying of cable through pipe and making good the disturbed surfaces to match with existing using PCC M-15, type B-I with 20 mm graded crushed stone aggregate including removing surplus material to a distance not exc 50 metres from starting point, complete and as directed.
Renewal of sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 8 way, double door, 240 volts with 200 Amp rated bus bar including taking down ICDP/ DB's any type, kit kat fuse, MCB's any type, all as specified. Make : Havells Cat Part No. DHDPSHODPW08/ C&S Cat Part No CSDBSPNSD08 or equivalent in makes mentioned in Appx 'C'.
Renewal of sheet metal enclosures for DBs when MCBs to be used, triple pole and neutral, 4 way, double door, 415 volts with 200 Amp rated bus bar including taking down ICDP/ DB's any type, kit kat fuse, MCB's any type, all as specified. Make : C&S Cat Part No CSDBTPNHPDD08 or equivalent in makes mentioned in Appx 'C'.
Renewal of MCB 100 Amps, TPN, 50HZ, 415 volts complete all as specified and directed by Engr-in-charge/GE. Makes as mentioned in Appendix 'C'.
MCB SPN 63 Amps, 415 Volts, 10 KA all as specified.
MCB SPN 6 to 32 Amp, 240 Volts, 10 KA all as specified.
MCB SP 6 to 40 Amp, 240 Volts, 10 KA all as specified.
Excavation in trenches for pipes, cables and manholes in any type of soil n.exc 1.5m wide and but exc 1.5m deep and getting out complete all as specified and directed.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any type of soil complete all as specified and directed.
Removal of excavated material (soil) to a distance n.exc 50 metres and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cms thick, complete all as specified and directed Note: Punned thickness shall be measured.
Sub class "B" bricks for covering to cable laid dry flat, with width equal to length of bricks all as specified and directed.
GI pipe light grade of size 40 mm dia laid in trenches/ walls including clamps, screws etc, complete all as specified and directed.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 35 Sqmm 4 core laid in trenches, passing through pipe/ ducts/ surface of wall ceiling etc including testing complete all as specified. Note:- Excavation & Earth work, cable cover and sand cushioning shall be measured and paid separetly.
Renewal of concealed sub main wiring with two single core PVC insulated cable 1100 volts grade with copper stranded RLS conductor of size 6 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire of size 4 Sqmm and drawn into PVC concealed conduit with all fittings/ accessories, junction boxes 1 to 4 way 20mm dia, cutting chases, making good in cement mortar in CM (1:3), finishing surfaces to match with existing and connected to common earth dolly, complete and as directed. Note :- Two run (each run of 1 RM) of 6 sqmm copper conductor and one RM of earth wire of 4 Sqmm, shall be measured as one RM).
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 25x 4mm dia (as earth lead), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Air termination, single pointed aluminium rod 12mm dia and 300mm long, fixed in repair complete all as specified and directed.
Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground , fixed in repair complete all as specified and directed.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw, fixed in repair complete all as specified and directed.
m/S Varun Gupta
Havish Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .