Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAccepted-AOC | L1 | Accepted-AOC Ist Lowest | |
| 2 | L2₹1.7 L+₹510 (0.30%)Rejected-AOC 58 KAILASHPURAM GOVINDPURAM GAZIABAD | GHAZIABAD | UTTAR PRADESH | L2 | Rejected-AOC IIndLowest | |
| 3 | L3₹1.9 L+₹16,677 (9.90%)Rejected-AOC 19 A DURGA BARI SADAR BAZAR MEERUT MEERUT MEERUT UTTAR PRADESH 250001 | MEERUT | UTTAR PRADESH | 250001 | L3 | Rejected-AOC IIIrd Lowest |
Tender Value
₹1.7 L
EMD Value
₹1,700
Closing Date
2 Sept 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Transmission Circle-II, U.P. Power Transmission Corporation Ltd. 57- George Town, Prayagraj.
22/ETC-II(P)/2024-2025
2024_UPTCL_942234_1
22/ETC-II(P)/2024-2025
Open Tender
Electrical Works
Item Rate
60 days
132 KV S/S Bharwari
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Executive Engineer Electy. Trans. Div. Naini Alld.
₹1,700
7 Jan 2025
31 Jul 2024
3 Sept 2024
31 Jul 2024
2 Sept 2024
31 Jul 2024
Amount
Following work are required for centrifuging of complete Transformer Oil and Oil sample Testing of 20 MVA, 132/33 KV M/s GEC make Power Transformer installed at 132/33 KV S/S Bharwari, Kaushambi.
Centrifiuging of complete Transformer Oil of 20 MVA, 132/33 KV M/s GEC make Power Transformer in transformer Tank by connecting centrifiuging pipes, circulating the Transformer Oil through centrifiuging machine, to be provided by the contractor and taking the BDV/PPM Values of the Oil periodically (by type tested equipment) till the required value of the Oil is achived as per direction of supervising Engineer at 132 KV S/S Bharwari. This work also include opening of jumper if required and re-connecting of jumper after completion of works. (All T&P, labor,centrifuging machine & other associated arrangements shall be provided by the contractor at his own cost.)
Testing of centrifuged T/F Oil of 132/33 KV, 20 MVA T/F is requied two times from govt. Certified lab before charging and after charging of Transformer. (Sampling bottle, required kit and all associated work/supply will be provided by contractor on their own cost) 1. BDV 2. PPM 3. DGA
The following work is required for smooth operation of installed on 20 MVA T/F at 132 KV S/S Bharwari, Kaushambi. The details of work listed below.
Supply and fixing of winding temperature indicator (analog type) of temp range from (0-150) OC, 5A, AC/DC both and consist of two flexible capillary tubes of 05 meter long and 02 no mercury bulb switch for alarm, trip and cooling control system of power Transformer of standard make. Work includes fixing of capillary inside the temperature sensing element within the tank and proper termination of connection at both ends.
Supply and fixing of Oil temperature indicator (analog type) of temp range from (0-150) OC, SA, AC/DC both and consist of two flexible capillary tubes of 05 meter long and 02 no mercury bulb switch for alarm & trip of power Transformer of standard make. Work includes fixing of capillary inside the temperature sensing element within the tank and proper termination of connection at both ends. This work also include replacement of damage oil temp indicator mounted on radiator tank. (including all supply).
The following supply & work are required for smooth operation of cooling fan installed on 20 MVA T/F at 132 KV S/S Bharwari, Kaushambi. The details of work listed below.
Supply and fixing of 01 no main switch of 3P/IW, 415V, 16A rating and 01 no MCB of 4 pole, 415 V.16A rating for 3 phase incoming supply for cooling fans.
Supply and fixing of 01 no 415 volt, 16 A, 4 No, contactor for main supply of cooling fans installed on 20 MVA T/F work includes proper connection of contactor with ACDB or AC cubical installed in the switchyard.
Supply and fixing of 02 no fan control contactors of rating 230v, 9A for auto function of cooling fans and 03 no relays of rating 230 V. 9A, 02 NO-02 NC for supply monitoring for cooling fans.
Fixing of 08 no, 3 pole MCB of rating 230 V, 2A to be fixed on the front side of marshaling box (MCB provided by contractor on their own cost).
Supply and Fixing of 08 no thermal overload relay (Type 3US5000) of rating (0.5-1A) for cooling fan of transformer on the front side of the marshaling box.
SARASWAT ELECTRICALS
Technocrat Electrical
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .