Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹54.8 L+₹2.9 L (5.51%)Rejected-AOC VILLAGE PO MALAHAT TEHSIL DISTRICT UNA HP | L2 | Rejected-AOC L2 | |
| 3 | L3₹59.6 L+₹7.7 L (14.8%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹59.9 L+₹8.0 L (15.4%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹60.1 L+₹8.2 L (15.8%)Rejected-AOC | L5 | Rejected-AOC L5 |
| Sl No | Description | Qty | Unit | Nitish Thakur L2 | Vivek Dhiman L3 | Nishant Puri Govt Contractor L1 | Vipan Kumar L6 | aditya govt. contractor L4 | puneet angra L5 | Mr. Sanjeev Kumar L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in foundations and trenches (for pipes and pits for other civil structures) upto all depths in all kinds of soil such as pick work, jumper work and saturated soil and paved surfaces including bailing or pumping out of water, chiseling or wedging out of same where blasting is prohibited in all leads and lifts including trimming and dressing of sides, leveling of beds to correct grade including shoring, strutting, planking timbering and dewatering wherever required, stacking usable and unusable material/soil separately and after laying jointing and testing of pipes, returning the usable soil in 15 cm layer by ramming and watering and then disposing of all surplus excavated soil/unusable material as directed within all leads and lifts including cost of diversion of traffic, night signal boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects as per the direction of Engineer-in-charge. | 2,281.13 | Per Cum | 119 ₹2,71,454.47 Lowest | 125 ₹2,85,141.25 | 125 ₹2,85,141.25 | 190 ₹4,33,414.7 | 140 ₹3,19,358.2 | 135 ₹3,07,952.55 | 196 ₹4,47,101.48 |
| 2.00 | Excavation in foundations trenches etc. in carth work, lift upto 1.50 mts. Stacking the excavated syd not more than 3 mts. Clear from the edge of the excavation & then returning the stacked soil in 15 cams. Layers, when required into plinths sides of foundation etc. consolidating each deposited layers by ramming & watering & then disposing of all surplus excavated carth as dierected within all leads & lifts as per entire satisfaction of Engineer in charge | 13.7 | Per Cum | 56 ₹767.2 Lowest | 150 ₹2,055 | 200 ₹2,740 | 190 ₹2,603 | 140 ₹1,918 | 135 ₹1,849.5 | 196 ₹2,685.2 |
| 3.00Laying. Jointing and Testing in trenches Galvanized mild steel flanged/butt welded pipe of below mentioned dia and grade conforming to IS 1239-2004 (with latest ammendments The MS flanges are to be provided 5% of total joints as per table below conforming to 6392 1971 (Latest uptodate ammendments) and welding of MS flanges with pipe as per is 816-1965 with electrode as per IS 814-1967 including required Nos and size of M.S nuts and bolts as per 15 1369-1967 and compressed asbestos fibre jointing gaskets sheet not less than 3mm thick as per IS 27121-1965 The welding of flanges to be done on both faceless three layers in each face to make the joints leak proof including all kind of specials such as bends of all degree to be made from parent tube short pieces, tail pieces all made from parent tube and to the entire satisfaction of enginer-in-charge The pipes end should be bevelled suitable for butt welding The circumferencial butt welded joints (96% of the total joints) by electrical arc welding to following dia & class pipes, welding of pipes to be done in three layers to make the joints leak proof and to achieve the minimum effective throat thickness of weld conforming to IS-816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani oerlikon (Adore)-CITOJET/ESAB make, conforming to IS 814-1991 at site of work complete in all respects and including DPT test for joints & manual/mechnical handing of pipes The laying of pipe shall confirm to BIS-5822 (with latest ammendments uptodate), including all kind of specials such as bends of all degree to be made from parent tube, short pieces, tail pieces all made from parent tube within all leads and lifts Earth work in trenches, M.S. flanges and butt welded joints to be measured and paid for separately) | ||||||||||
| 3.01 | GI pipe 125mm dia (M.C) P/E | 110 | Per Rmt | 50 ₹5,500 | 95 ₹10,450 | 70 ₹7,700 | 80 ₹8,800 | 25 ₹2,750 Lowest | 65 ₹7,150 | 65 ₹7,150 |
| 4.00Providing, Laying. Jointing and Testing in trenches Galvanized mild steel flanged/butt welded pipe of below mentioned dia and grade conforming to IS 1239-2004 (with latest ammendments The MS flanges are to be provided 5% of total joints as per table below conforming to 6392 1971 (Latest uptodate ammendments) and welding of MS flanges with pipe as per is 816-1965 with electrode as per IS 814-1967 including required Nos and size of M.S nuts and bolts as per 15 1369-1967 and compressed asbestos fibre jointing gaskets sheet not less than 3mm thick as per IS 27121-1965 The welding of flanges to be done on both faceless three layers in each face to make the joints leak proof including all kind of specials such as bends of all degree to be made from parent tube short pieces, tail pieces all made from parent tube and to the entire satisfaction of enginer-in-charge The pipes end should be bevelled suitable for butt welding The circumferencial butt welded joints (96% of the total joints) by electrical arc welding to following dia & class pipes, welding of pipes to be done in three layers to make the joints leak proof and to achieve the minimum effective throat thickness of weld conforming to IS-816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani oerlikon (Adore)-CITOJET/ESAB make, conforming to IS 814-1991 at site of work complete in all respects and including DPT test for joints & manual/mechnical handing of pipes The laying of pipe shall confirm to BIS-5822 (with latest ammendments uptodate), including all kind of specials such as bends of all degree to be made from parent tube, short pieces, tail pieces all made from parent tube within all leads and lifts Earth work in trenches, M.S. flanges and butt welded joints to be measured and paid for separately) | ||||||||||
| 4.01 | GI pipe 65mm dia (H.C) P/E | 5,400 | Per Rmt | 723 ₹39,04,200 | 760 ₹41,04,000 | 700 ₹37,80,000 Lowest | 850 ₹45,90,000 | 780 ₹42,12,000 | 840 ₹45,36,000 | 836 ₹45,14,400 |
| 5.00Providing and welding MS flanges @5% of total joint conforming to following tables as per IS 6392-1971 (Last with upto date amendments) with plan end G. I/MSERW pipe in three (One inner and two outer) number of layers on both faces to make the joint leak proof (The cost of providing and laying of Gl pipes to be measured and paid for separately) The welding of flanges should conform to IS 816-1969 with electrodes as per IS 814-1991 and required number of nuts and bolts conforming to IS 1364 including cost of gasket sheet nuts & bolts. The thickness of gasket sheet not less then 3.00 mm conforming to IS 2712-1998. The work shall be done tothe entire satisfaction of engineer in charge within all leads and lifts | ||||||||||
| 5.01 | GI pipe 125mm dia (M.C) P/E Table-5 | 1 | Per Pair | 1,200 ₹1,200 | 1,200 ₹1,200 | 400 ₹400 Lowest | 1,350 ₹1,350 | 1,200 ₹1,200 | 1,600 ₹1,600 | 900 ₹900 |
| 5.02 | GI pipe 65mm dia (H.C) Table-28 | 24 | Per Pair | 1,000 ₹24,000 | 800 ₹19,200 | 210 ₹5,040 Lowest | 900 ₹21,600 | 1,500 ₹36,000 | 1,300 ₹31,200 | 750 ₹18,000 |
| 5.03 | GI pipe 65mm dia (H.C) Table-17 | 15 | Per Pair | 970 ₹14,550 | 800 ₹12,000 | 190 ₹2,850 Lowest | 750 ₹11,250 | 1,200 ₹18,000 | 1,000 ₹15,000 | 650 ₹9,750 |
Tender Value
₹73.0 L
EMD Value
₹1.3 L
Closing Date
7 Aug 2025, 5:00 pmClosed
Executive Engineer
Jal Shakti Division Thanakalan
C/O pump house P/L of R/main, S/E of pumping Machinery, Providing and fixing of internal wiring for pump house
2025_HPIPH_111367_1
UNA-UNA03-733
Open Tender
Civil Works
Lump-sum
180 days
Thanakalan
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,000
₹1.3 L
1 Nov 2025
31 Jul 2025
8 Aug 2025
31 Jul 2025
7 Aug 2025
31 Jul 2025
31 Jul 2025 - 7 Aug 2025
Amount
Excavation in foundations and trenches (for pipes and pits for other civil structures) upto all depths in all kinds of soil such as pick work, jumper work and saturated soil and paved surfaces including bailing or pumping out of water, chiseling or wedging out of same where blasting is prohibited in all leads and lifts including trimming and dressing of sides, leveling of beds to correct grade including shoring, strutting, planking timbering and dewatering wherever required, stacking usable and unusable material/soil separately and after laying jointing and testing of pipes, returning the usable soil in 15 cm layer by ramming and watering and then disposing of all surplus excavated soil/unusable material as directed within all leads and lifts including cost of diversion of traffic, night signal boards, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects as per the direction of Engineer-in-charge.
Excavation in foundations trenches etc. in carth work, lift upto 1.50 mts. Stacking the excavated syd not more than 3 mts. Clear from the edge of the excavation & then returning the stacked soil in 15 cams. Layers, when required into plinths sides of foundation etc. consolidating each deposited layers by ramming & watering & then disposing of all surplus excavated carth as dierected within all leads & lifts as per entire satisfaction of Engineer in charge
Laying. Jointing and Testing in trenches Galvanized mild steel flanged/butt welded pipe of below mentioned dia and grade conforming to IS 1239-2004 (with latest ammendments The MS flanges are to be provided 5% of total joints as per table below conforming to 6392 1971 (Latest uptodate ammendments) and welding of MS flanges with pipe as per is 816-1965 with electrode as per IS 814-1967 including required Nos and size of M.S nuts and bolts as per 15 1369-1967 and compressed asbestos fibre jointing gaskets sheet not less than 3mm thick as per IS 27121-1965 The welding of flanges to be done on both faceless three layers in each face to make the joints leak proof including all kind of specials such as bends of all degree to be made from parent tube short pieces, tail pieces all made from parent tube and to the entire satisfaction of enginer-in-charge The pipes end should be bevelled suitable for butt welding The circumferencial butt welded joints (96% of the total joints) by electrical arc welding to following dia & class pipes, welding of pipes to be done in three layers to make the joints leak proof and to achieve the minimum effective throat thickness of weld conforming to IS-816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani oerlikon (Adore)-CITOJET/ESAB make, conforming to IS 814-1991 at site of work complete in all respects and including DPT test for joints & manual/mechnical handing of pipes The laying of pipe shall confirm to BIS-5822 (with latest ammendments uptodate), including all kind of specials such as bends of all degree to be made from parent tube, short pieces, tail pieces all made from parent tube within all leads and lifts Earth work in trenches, M.S. flanges and butt welded joints to be measured and paid for separately)
GI pipe 125mm dia (M.C) P/E
Providing, Laying. Jointing and Testing in trenches Galvanized mild steel flanged/butt welded pipe of below mentioned dia and grade conforming to IS 1239-2004 (with latest ammendments The MS flanges are to be provided 5% of total joints as per table below conforming to 6392 1971 (Latest uptodate ammendments) and welding of MS flanges with pipe as per is 816-1965 with electrode as per IS 814-1967 including required Nos and size of M.S nuts and bolts as per 15 1369-1967 and compressed asbestos fibre jointing gaskets sheet not less than 3mm thick as per IS 27121-1965 The welding of flanges to be done on both faceless three layers in each face to make the joints leak proof including all kind of specials such as bends of all degree to be made from parent tube short pieces, tail pieces all made from parent tube and to the entire satisfaction of enginer-in-charge The pipes end should be bevelled suitable for butt welding The circumferencial butt welded joints (96% of the total joints) by electrical arc welding to following dia & class pipes, welding of pipes to be done in three layers to make the joints leak proof and to achieve the minimum effective throat thickness of weld conforming to IS-816-1969 specifications, by using welding electrodes of 2.5 mm to 6.3 mm of Advani oerlikon (Adore)-CITOJET/ESAB make, conforming to IS 814-1991 at site of work complete in all respects and including DPT test for joints & manual/mechnical handing of pipes The laying of pipe shall confirm to BIS-5822 (with latest ammendments uptodate), including all kind of specials such as bends of all degree to be made from parent tube, short pieces, tail pieces all made from parent tube within all leads and lifts Earth work in trenches, M.S. flanges and butt welded joints to be measured and paid for separately)
GI pipe 65mm dia (H.C) P/E
Providing and welding MS flanges @5% of total joint conforming to following tables as per IS 6392-1971 (Last with upto date amendments) with plan end G. I/MSERW pipe in three (One inner and two outer) number of layers on both faces to make the joint leak proof (The cost of providing and laying of Gl pipes to be measured and paid for separately) The welding of flanges should conform to IS 816-1969 with electrodes as per IS 814-1991 and required number of nuts and bolts conforming to IS 1364 including cost of gasket sheet nuts & bolts. The thickness of gasket sheet not less then 3.00 mm conforming to IS 2712-1998. The work shall be done tothe entire satisfaction of engineer in charge within all leads and lifts
GI pipe 125mm dia (M.C) P/E Table-5
GI pipe 65mm dia (H.C) Table-28
GI pipe 65mm dia (H.C) Table-17
GI pipe 65mm dia (H.C) Table-5
Providing circumferential butt welded joints @95% by electrical arc welding to GMS pipe welded in requisite number of weld runs so as to achieve the minimum effective throat thickness of weid conforming to IS 816-1969 specifications, by using welding electrodes of 2 5mm to 6.3mm of Advani Oerilikon (Adore)-CITOJET/ES/ESAB make,conforming to IS 814-1991 include Die pentration test at site of work complete in all respects, including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer in-Charge
GI pipe 125 mm dia (M.C)
GI pipe 65 mm dia (H.C)
Providing and laying cement concrete 1:6:12 (1cement : 6sand:12 graded stone aggregate 40mm nominal size and curing complete excluding the cost of form work in foundation and plinth in all leads and lifts.
Providing and laying cement concrete 1:2:4(1cement:2sand:4 graded stone aggregate 20mm nominal size)and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in:-
Suspended floors, roofs, landings and shelves and their supports, balconies,beams, girders, bressumers and cantilevers upto all floor level complete involving acomplete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Prov.form work with steel plates 3.15mm thick welded with angle iron frame 30 x 30 x 5mm so as to give a fair finish including centring, shuttering,strutting & propping etc. with wooden battens and ballies, height of propping & centering below supporting floor to ceiling not exceeding 4mtr.& removal of same for insitu rainforced concrete and plain concrete work complete in all leads and lifrs and as per the directioin and to the entire satisfaction of the Engineer-in-Charge :-
Flat surfaces such as soffits & suspended floors, roofs, landing and the like. Floor etc. upto 200mm in thickness.
For lintal,Beam girders,Plinth beam,bressumers and cantilevers.
Edges of slab
Providing, Laying mild or tor steel reinforcement for RCC. Work including bending binding and placing in position complete upto floor two level Tor steel complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surfaces (two coats)to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials with in all leads and lifts and as per the direction and to the entire satisfaction of the Engineer-in-Charge..
Brick work using common burnt clay building brick in foundation and plinth in cement mortar 1:6(1cement:6sand) 2nd class brick complete all leads and lifts to the entire satisfaction of Engineer-in-charge.
In super structure in CM 1:6
Boulder/stone filling behind retaining wall/ under floor dry hand packed tightly compelete under lean concrete to prevent the entry of surface water with in all leads and lifts complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Cement concrete flooring 1:2:4 (1 cement:2 sand :4graded stone aggregate 20mm nominal size )laid in one layer finished with a floating coat of neat cement in 40mm thick in all leads and lifts.
20mm thick cement plaster in single coat on rough side of stone /brick masonry walls for interior plastering upto floor two level including arrises, internal rounded angles, in all girth chamfers and / or rounded angles and finished even and smooth in cement mortar 1:6(1cement:6sand) complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
6mm cement plaster to ceiling in cement mortar 1:3 (1 cement 3 sand) finished with a floating coat of neat cement and thick coat of link wash on top of wall when dry for bearing of RCC slab and bend in all leads and lifts
Providing and fixing pressed steel doors frames manufactured from commercial mild steel sheet of 1.60mm thickness including hinges jumb lock jamb,beed and if reuired angle threshold of mild steel angle of section 50X25 mm or base ties of 1.60 mm pressed mild steel welded or regidly fixed together by mechanical means,adjustable lugs with split and tails to each jamb including steel butt hinges 2.5 mm thick with guards,lock strike plate and shock absorber as specified and applying a coat of approved steel primer after pretretment of the surface as directed by Engineer-in-Charge.(Profile-A)
Providing second class deodar wood paneled glazed or paneled and glazed shutters for doors, windows and clerestory windows including bright finished black enameled iron butt hinges with necessary screws with second class deodar wood 40mm thick in all leads and lifts.
Providing and fixing of M.S. grill of required pattern in wooden frames of windows etc with M.S. Flat square or round wire with round heads bolts and nuts or by screw plain grill as per direction and to the entire satisfaction of Engineer-in-charge.
Pointing on brick work with cement mortar 1:3 (1cement 3 sand) Raised and cut pointing.
Providing plinth protection 50mm thick in cement concrete 1:3:6(1cement:3sand:6graded stone aggregate 20mm nominal size) including finishing of the top surface of concrete smooth in all leads and lifts.
Providing plinth protection 75mm thick in cement concrete 1:3:6(1cement:3sand:6graded stone aggregate 20mm nominal size) including finishing of the top surface of concrete smooth in all leads and lifts.
Providing 40x3mm flat iron hold fast 40cm long including fixing to frame with 10mm dia meters bolts and nuts and wooden plug and embedding in cement concrete block 30x10x15cm 1:3:6(1cement:3sand:6 graded stone aggregate 20mm nominal size).
Providing and fixing M.S.fan clamp (Type-I)of 16mm dia M.S. including bend upto shape with broken end in RCC. Slab door painting the exposed position of trap all as per standard design complete in all leads and lifts.
White washing with lime on undecorated walls surface (two coats)to give an even shade including throughly brooming the surface dirt dust mortar dirt and other foreign matter in all leads and lifts.
Distempering with dry distemper of approved brand and manufacturer, (two coat) and of required shade on undecorated wall sarfaces to give an even shade over and including primer coat of whiting after throughly brushing the surface free from mortor dropping and other foreign matter including preparing the surface even and prepared smooth complete in all leads and lifts.
Applying priming coat over new wood and wood based surface after and including preparing the surface by thoroughly cleaning oil dirt grease and other foreign matter sand papering and knotting ready mixed paint brushing wood primer pink in all leads and lifts.
Providing and fixing anodized M.S sliding door bolts anodized transparent for type required and bright shade with necessary screw etc. complete. 250x16mm
Providing and fixing M.S tower bolts (Barrel type) anodized transparent or dyed to rquired shade and colour with necessary screw etc. complete in all leads and lifts. 200x10mm
Providing and fixing M.S tower bolts (Barrel type) anodized transparent or dyed to rquired shade and colour with necessary screw etc. complete in all leads and lifts. 150x10mm
Providing and fixing M.S handles anodized transparent or dyed to required colour of shade with necessary screws etc. complete 125 mm
Providing and fixing M.S handles anodized transparent or dyed to required colour of shade with necessary screws etc. complete 75 mm
Painting two coats(excluding priming coat) on new wood and wood based surface with ready mixed paint brushing the give and even shade including cleaning of all dirt dust and other foreign matter and sand papering and stopping with ready mixed paint other than white in all leads and lifts.
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable complete in all respect. "Group-C"
Wiring for power plug with (2x4 Sq.mm) PVC insulated,heat resistant flame retardant(HRFR) and low smoke single core(flexible)copper conductor cable in surface/recessed PVC conduit along with 1 No. 4 Sq.mm. HRFRLS/PVC insulated sigle core copper conductor cable for earthing as required including carriage of material with in all leads & lifts complete.
Wiring for light plug with (2x1.5 Sq.mm) PVC insulated,heat resistant flame retardant(HRFR) and low smoke single core(flexible)copper conductor cable in surface/recessed PVC conduit along with 1 No. 1.5Sq.mm. HRFRLS/PVC insulated sigle core copper conductor cable for earthing as required including carriage of material with in all leads & lifts complete.
Wiring for circuit/sub-main with 2x6 Sq. mm size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required including carriage of material with in all leads & lifts complete.
Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 3 pin 15/16 amps socket outlet and 15/16 amps, piano type switch, connections, ainting etc. as required..
Supplying and fixing bakelite batten/angle holder including connections etc. as required
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required with in all leads & lifts complete. Ceiling Fan 1200 mm sweep, Category-A
Providing and fixing ultra slim decorative extruded box fixture with domestic electronic ballast, snap-on installers, suitable for 28 watt FTL (T5), complete with all accessories (including one No. T-5 Tube), connections, testing and commissioning etc. as required. as required complete as per direction of the Engineer-in-charge.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required complete as per direction of the Engineer-in-charge. Cat. A
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire?set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- as required with in all leads & lifts complete. Double door-8 way
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required with in all leads & lifts complete. Single pole. Cat-A
Providing, Installation, testing and commissioning of prewired flourscent tube fitting 1x40 watt box type Cat A i.e. Bajaj make complete with balast starter and capacitor but excluding flourscent tube rod suitable to operate on 240volt single phase AC supply directly on surface with copper wiring as required complete as per direction of the Engineer-in-charge.
P/F street light fixture 40watts 4 feet long complete with choke starter i/c connection complete as required complete as per direction of the Engineer-in-charge.
Submersible Pumping Machinery For Head works
Supply of submersible pumping set of reputed make such as KSB/ Calama / BS/ Worthigton / Sabar/ Seerex /Johnston / Amrut/ lubi/ Hindustan/Groundfos /Kirloskar confirming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ; 5659-1978 with upto date amendments, suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to submersible motor of same as that of offered submersible pump make confirming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed, lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear tear.It should also be fitted with a device to make up expantion of water with heating of motor. The pumpset should include water level guard i/c cable ,errection clamps, cable clips and depth gauge etc. and suitable for opertion on data given below. a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation
Discharge = (Q) 14.50LPS
Total Head = ( H) 63.24 Mts.
a) SWL in Tubewell = 38.00 Mtr. bgl.
c) R.L. point of discharge =403.00 Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly. = 3.00 Mtrs.
e) Drawdown in Tubewell =7.00 Mtrs.
f) R.L of lowest point of pumpset installation = 352.00 Mtrs.
g) Static head = Mtrs. Static column lift=
Rising main.
Length 110 Mtrs.
Dia meter. 125 mm
Class GMS Pipe (MG)
Column Pipe.
Length 48.00 Mtr.
Dia 125 mm
Class GMS. (M)
Pumping hours = 8.00 Hours
Altitude of installations above M.S.L. 400 Mtr.
Characteristic of water.
a) Temperature 20 Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well = 150 Mtr.
Dia of T/ well assembly 200 mm
Length of assembly pipe. meter .
Dia of housing pipe 300 mm
Length of housing pipe. meter
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing:- Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation : Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Driver Type: Electric driven.
Operating Range: -15 % to+10 % of Total head at duty point.
Delivery size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells make and having capacity 30% extra of the operational rating as per IS : 13947- P I & II with upto date amendments. i) Make : ii) Type : iii) Capacity : 63 amp.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. Panel/ Switch Board i) Drawing. ii) Layout Plan
MCCB of kilburn / L&T/ Havells make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. i) Make : ii) Type : iii) Range 100 amp. iv) Capacity 63 amp
ELCB of recommended make L&T /Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELCB i) Make : ii) Type : iii) Range 63Amp. iv) Capacity
The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage, reverse phasing, overloading and phase voltage difference as per IS; 3842 ( Latest Edition )i) Make : ii) Type : iii) Range 0-500.
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ; 8084-1976 and IS : 11353-1985 read with BIS ; 5578 -1985 with upto date amendments including. 3 phase indicators i) Make : ii) Type : iii) Rating
Three phase indicator lamps complete with toggle switches for individual motors as per IS 3452 (P- I&II ) with upto date amendments. 3 Phase indicators
Capacitor of BHEL / L&T make as per IS ; 2834-1968 with upto date amendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter/ IEC make) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments .Rate of capacitor will be approved by HPSEB. i) Make : ii) Type : iii) Range. 5 KVAR
Providing Auto transformer starter of L&T/ Havell's /BHEL make as per IS :13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic 'type overload release and dashpot, time lag, under voltage release, with or without 'initial oil filling as the case may be with Air Break. Type Star Delta with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. Single Phase Preventor i) Make : ii) Type : iii) Range.
Providing and fixing double flanged Cast Iron Sluice valve of Leader / Kirloskar /kartar/LP/RG Brand make for the delivery line of pump and capable of withstanding the normal seat pressure and as per 15780-1992 with latest ammendments i) Make : ii) Type : iii) Make :- Cast Iron class for Column Pipe 150 mm dia Class PN-1.00
Providing and fixing double flanged swing type cast Iron Reflux valve of Leader/ Kirloskar/Kartar / LP/RG Brand make having Bye pass arrangement on the delivery line of the Pump and capable of 'withstanding normal Seat Pressure as per 5312 with latest ammendments i) Make : ii) Material : cast iron iii) Class PN-1.6 For for R/main 125 mm dia.
Providing and fixing pressure gauge of Prega / Precision make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements. i) Make :
Supply of PVC jointless, flat water proof cable with copper conductor as per BIS 694-1998 latest with upto date ammendments of Havells/ Finolex make suitable for the pumpsets offered from MCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe, solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor. The type, size and make shall be subject to approval of HPSEB authorities. i) Make : Finolex/ Havells ii) motor side 4 mm2 iii). type- IV capacity V Core-3
Lowering of GMS Column pipefor assembly 150 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber/asbestos gasket of min. 3mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 . The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No.62 . The Column pipe should be extended upto 10 mtr. beyond the outer wall of the pump house in the direction of Rising main . The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. (The pipe shall be supplied by the Department free of cost from Divisional Store Barnoh. Column Pipe 150 mm dia GMS pipe(M)
Installation of all items appearing as above as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 (P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay /Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts, cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply Side From meter of HPSEB to Bus Bar and Switch) i) Size 25.00 mm2 & 50mm 2 ii) Make Finolex/Havells. iii) Type iv) Capacity v) Core 3. Supply side 10 mm2
Providing and fixing double loop earthing with G.I. Flat suitable thickness electrode complete with material such as thimble, nuts and bolts, charcoal, salt, common as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge. i) up to 50 HP GI wire 4 SWG beyond 20 to 30 HP
Centrifugal pumping Machinery
Providing horizontal spindle, horizontal / radial split casing /end suction ( back pull out arrange-ment) Single /double /multi stage of Kirloskar / KSB Crupton KSB/Calama/BS/ Groundfos/ Hindustan/ Lubbi make as per BIS IS 1520-1980 with upto date ammendments read with IS: 9137-1978 or latest edition suitable for lifting water for under mentioned characteristic with Bronze impellers / priming funnels, casing ring and shaft sleeves of Bronze shaft of stainless steel with cast iron casing, coupled directly through a flexible coupling on a common cast iron / cast steel base plate (base plate to be framed from the manufacturers of the pumping unit only) to slipring / Squirrel cage screen protected drip proof induction motor / motors of standard make such as Crompton / NGEF / GEC / Seimens /Jyoti/ Kirloskar BHEL / ABB suitable for operation on 415 (+/-15%) volts. 50 Cycles /Sec. 3 phase AC electric supply of 2900 RPM.The power of electric motor/ motors should be at least +10% in excess of the maximum power required by the pump / pumps in the Operation range of (+10%) and (-15%) of the duty point head. The motor / motors as per IS 325 IS -1978 with upto date amendments read with IS 900 -1972. It should include cost of Bearing. Nuts, Bolts and painting etc. and should meet the following requirements. (a) Pump :- Specifications i) Make ii) Model iii) No. of stages iv) Manfacurer's certificate to be attached. performance i) Discharge ii) head Make ii) Model iii) efficiency of pump a) duty Head b) (+) 10% duty head c). (-) 15% Duty Head d) performance curve to be attached b). Motors:- Specificions Make ii) Model iii) Rating iv). speed v) Insulation (C) Coupling (D) Base plate
Discharge (Q) = 2.79 LPS.
Total Head (H) = 263.50 Mtrs.
a)LWL In Sump well = 400.00 mtr
b)R.L. of shaft = 400.00 Mtrs.
c)R.L. of discharge Pt. = 525.00 Mtrs.
d)Suction lift. +ve mtrs.
e)Discharge Head = Mtrs.
f) Static Head = 125.00 Mtrs.
Rising main.
Length =5400 Mtrs.
Diameter = 65 mm. dia
Class GMS Tube(M)
Pumping hours. = 8 Hours.
Altitude of installations above M.S.L =400 mtrs.
Characteristic of Water
a)Temperature 20 Deg.Col.
b)Turbidity ________ JTU
c)Alloanity _________ mg/1 ca Co3
d)Size of solids __________ mm
e) Others.
Providing ICTP Main Switch with HRC fuses of L&T/ Havells make and having capacity 30% extra of the operational rating as per IS : 13947-P I & II with upto date amendments.i) Make : ii) Type : iii) Capacity : 63 amp.
Providing MS Sheet, steel fabricated floor mounted closed (Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted with steel sheet of 16 Gauge comprising and capable of mounting the following acccessories with all internal connections.
i) MCB of L&T / Havells make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516--1985 with upto date amendments . i) Make : ii) Type : iii) Capacity : 63 amp.
ii)ELCB of recommended make L&T / Havells make as per IS: 2516-1985 with upto date ammendments, and of suitable range which should have control box, operating handle and trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. i) Make : ii) Type : iii) up to 63 amp.
iv )The voltage monitor Relay three Phase with all protection and usual indicator and electric siren against single phasing, low vaoltage, high voltage reverse phasing, overloading and phase voltage difference as per IS 3842 ( Latest Edition). i) Make : ii) Type : iii) Range:0-500
Power factor meter of standard make as per relevent IS code with upto date ammendments.i) Make : ii) Type : iii) Range: 0-500
Frequency meter of standard make as per relevent IS code with upto date ammendments..i) Make : ii) Type : iii) Range: 0-500
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three line phases and suitable for induced current one copper bar of half the rating of full length for neutral phase as per IS : 8084-1976 and IS: 11353-1985 read with BIS : 5578- 1985 with upto date ammendments including.i) Make : ii) Type : iii) Rating 63 amp.
Providing ICTP Switches with HRC fuses of L&T/ Havells make as per IS : 13947-P I & II with upto date amendments.i) Make : ii) Type : iii) Capacity : 63 amp..
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 (P-I&II) with upto date ammendments. i) Make : ii) Type : iii) Capacity
Capacitor of BHEL / L&T make as per IS : 2834-1986 with upto date ammendments, to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevant ISI code (of Seimens / Clocter / IEC make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064-1978 with upto date ammendments, Rating of capacitor will be approved by HPSEB. i) Make : ii) Type : iii) Range 5KVAR
Providing suitable Starter of L&T / Havell's / BHEL make as per IS : 13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic type over load release and dashpot, time lag under voltage release, with or without 'initial oil filling as the case may be with single Phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. i) Type ii) Make
Providing and fixing of double flanged Cast iron Sluice valve of kirloskar/Leader / Kartar/LP/RG Brand make as per IS 780-1992 with update ammendment for 150 mm dia suction pipe for the suction line of pump and capable of with standing the normal seat pressure as per BIS with upto date ammendments i) Material Cast Iron ii).class PN1.00 150 MM DIA
Providing and fixing of Cast iron double flanged Swing type reflux valve of kirloskar/Leader / Kartar/Kilburn /BHEL /LP/RG Brand make IS 5312 Part 1 of 150 mm dia having by pass arrangement for the Delivery line of the pump and capable of with standing the normal seat pressure as per BIS i)Make ii)Class PN 1.6 iii)Seat pressure(MPa) iv)Material Cast iron
Providing 100 mm dia circular dial pressure gauge of Precision / Fiebig make complete with all accessories such as stop cock, Copper tubing etc. as per IS: 3624-1987 with upto date ammendments. i) Make : Range.
Installation of all above items appearing above as per the systematic drawing attached with the documents or as per the direction of Engineer-in-Charge. .`
Providing and laying copper PVC Insulated 3 core armoured power cable (One cable carrying all the three phases) of suitable size and capacity to Motors and all other elelctrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Seimen / Gloster / IEC / ICC / EICO / National / Grandlay / finolex / Havell make ' including all other accessories such as thimble, flelxible pipes, solder, nuts & bolts, cable glands etc. laid in pipes or trenches under floor. Armoured Power Cable (A) Motor side (From Switch to Starter & Starter to motor) i) Size 10.00 mm2 ii) Make iii) Type - Armounred power cable iv) Capacity v) Core 3 (B) Supply Side (From meter of HPSEB to Bus Bar & Switch) i) Size 10.00 mm2 ii) Make iii)Type - Armounred power cable iv) Capacity v )3 Core
Providing and fixing double loop earthing with G.I. Flat suitable thickness electrode complete with material such as thimble, nuts and bolts, charcoal, salt, common as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge. i) GI wire 4 SWG beyond 20 to 30 HP.
Nitish Thakur (BID ID -542223)
Vivek Dhiman (BID ID -542284)
aditya govt. contractor (BID ID -541312)
puneet angra (BID ID -542260)
Vipan Kumar (BID ID -542210)
Mr. Sanjeev Kumar (BID ID -542290)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .