| 1 | L1₹43.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹49.1 L+₹1.6 L (3.35%)Rejected-Finance 1 28 NORTH STREET SOUTH VILAYANARAYANAM NANGUNERI TALUK TIRUNELVELI DIST 627 118 | TIRUNELVELI | TIRUNELVELI | TAMIL NADU | 627118 | L2 | Rejected-Finance being high bid value rejected | |
| 3 | L3₹49.8 L+₹2.3 L (4.75%)Rejected-Finance CHENNAI | L3 | Rejected-Finance being high bid value rejected |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
24 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Tirunelveli
GE TIRUNELVELI INS KATTABOMMAN NAVAL BASE POST VIJAYANARAYANAM TIRUNELVELI
GE/TVL/8180
2021_MES_497538_1
GE/TVL/8180
Open Tender
Miscellaneous Works
Item Rate
180 days
Ramnad
As per NIT/ Tender documents
8 documents required · 8 mandatory
₹500
GE Tirunelveli
₹88,000
Yes
23 Feb 2022
27 Dec 2021
26 Jan 2022
27 Dec 2021
24 Jan 2022
10 Jan 2022
27 Dec 2021 - 3 Jan 2022
60 days
Amount
SCHEDULE 'A' PART-I [ B/R WORKS ]
Demolition of brick or stone masonry built in cement mortar including all quoins,arches,pillers etc but excluding ashlar facings,dressed stone work and precast concrete articles.
Demolition of cement concrete in ground floor and pavings/tiles not exc 15 cm thick below or above GL complete all as specified and as directed.
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth, for foundation,shaft, well, csspits, manhole, pier hole etc in any type of soil and getting out complete all as specified and directed.
Material and labour for plain cement concrete 1:3:6, type C-2, using 40mm graded aggregate in foundation filling and mass concrete complete all as specified and as directed.
M&L Brick work with sub class 'B' old size built in CM 1 : 6, straight or curved on plan exc 6m mean radius on plan complete all as specified and directed.
M&L for rendering 15mm thick on brick or concrete surfaces in CM 1:4 on fair faces of brick work or concrete surfaces on wall surfaces finished even and smooth (without using extra cement) complete all as specified and as directed.
Material and labour for providing cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate cast in situ as in copings, surface channels , drain and the like including weathering, slightly rounded or chamfered or chamfered angles and throating including use of form work as necessary all as specified and as directed.
Material and labour for Forming fair finish drain or channel 30cm inner girth in cement concrete using extra cement including fors, moulds mi-tred/stopped end complete all as specified and as directed.
SCHEDULE 'A' PART-II [ E/M WORKS ]
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth, for foundation/laying cable in any type of soil and getting out complete all as specified and directed.
Returning, filling in incl spreading leveling, watering and well ramming in layers n.exc.25cm thick complete all as specified and as directed.
Removing excavated material to a distance n.exc 50m away and depositing where as directed at a level n.exc 1.5m above the starting point, complete all as specified and as directed.
Supply and spread natural river sand in trenches for cushioning and covering to cable complete all as specified and as directed. NOTE: Punned thickness shall be measured and paid.
Supply, lay in trenches burnt Bricks, old size, Sub class "B" designation 75 with width equal to the length of brick laid flat(brick per RM approximately) for cable protection all as specified and directed.
Laying only for LT under ground cable 1100 volts grade PVC /XLPE sheathed armoured multistranded heavy duty electric cable with aluminium conductor laid in trenches/ duct / walls including cable gland on both termination where necessary including laying, connecting to various switches in panel board, testing and commissioning etc including taking out existing unserviceable cables of following sizes complete all as directed & as specified:-
(a) 4 core 25 Sqmm
(b) 4 core 16 Sqmm Note for Item No. 16 to 16.02:- 1.LT UG cable for Item No. 16 to 16.02 shall be issued under Schedule 'B' under free of cost and earth work,cable protection and snd cusion shall be measured and paid seperately. 2. The quoted rate shall be deemed to be included of transport of cable from MES store to site including necessary T&P and no extra payment shall be made to the contractor on this account. 3. Testing of cable after laying shall be done by contractor and the cost shall deemed to be included in the quoted rate.
Fixing only in repairs energy saving LED street light fittings, 70 Watts or nearest higher wattage, connecting up light fitting with copper conductor cable of suitable size from junction box to connector block including all accessories and dismantling of old unserviceable fitting for taking into credit complete all as specified and as directed.
Fixing only of Search light of LED 150 watts along with all accessories for fixing in watch tower cabin connecting up light fitting with copper conductor cable of suitable size from junction box to connector block including all accessories complete all as specified and as directed.
Fixing only of LED post top lantern 20 watts or nearest higher wattage connecting up light fitting with copper conductor cable of suitable size from junction box to connector block including all accessories and dismantling of old unserviceable fitting for taking into credit complete all as specified and as directed.
Fixing only of LED flood light fittings with in-built electronic driver, 150 Watts or nearest higher wattage connecting up light fitting with copper conductor cable of suitable size from junction box to connector block including all accessories and dismantling of old unserviceable fitting for taking into credit complete all as specified and as directed. Note for Item No. 17 to 20:- 1.Light fittings for Item No. 17 to 20 shall be issued under Schedule 'B' under free of cost . 2. The quoted rate shall be deemed to be included of transport of light fitting from MES store to site including necessary T&P and no extra payment shall be made to the contractor on this account. 3. Testing of light fitting after fixing shall be done by contractor and the cost shall deemed to be included in the quoted rate.
Material and labour for Sub main wiring with PVC insulated unsheathed 1100 volts FRLS grade single core multi stranded copper conductor cable 2 runs of 2.5 sqmm drawn through in and including 20mm dia PVC conduit heavy duty ISI marked(IS 9537 Part III) fixed in walls and all accessories along with 1 run of 2.5 sqmm PVC insulated unsheathed copper conductor single core multi stranded cable 1100V FRLS grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed. Note: 2 runs of 2.5 sqmm cable along with 1 run of 2.5 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length.
Material and labour for preparation of old surface of electric pole 7.50 m long above ground level stickering with reflectors /radium strip with alternate layers of red and white each of height 20 cm with 4 layer starting with red upto 1.5m height from top of PCC coping complete all specified and as directed.
S & F in replacement of pole mounting type FRP cable looping box with connector and MCB SP 6 Amps of size 150mm x 200mm x 100mm with 40 x 6mm flat iron including suitable brass gland, lugs etc and terminal box to be fixed on pole with suitable fixing arrangement complete all as specified and as directed.
Supply and fix in repair of 32 mm dia light grade GI tube bracket of length 1.5 metre bend to required shape including MS clamp made out of 40 mm x 6 mm MS flat iron and fix on poles/wall with necessary GI bolts, nuts and washers - 2 sets for each fittings complete set all as specified and directed.
Cutting the existing bituminous road / cement concrete surface to the required width and depth including earth, for laying pipe lines and returning filling in, removal of surplus material complete all as specified. Note: PCC for making good the top level to match raod surface shall be measured and paid separately.
Demolition of cement concrete(unreinforcement) in ground floor & paving n. exc 15 cm thick (below or above GL) unreinforced complete all as specified and directed.
M & L for 100 mm thick cement concrete 1:2:4 type B-1, using 20mm graded aggregate for making good the disturbed road surface after laying of pipe line over compacted earth surface to match with existing road level complete all as specified and as directed.
Supply and fix MCB SP 5 A to 15 A , B curve, 10 kA in looping box complete all as specified and as directed.
Supply and laying GI tubing Light grade of size 40 mm dia bore laid in trenches / on floors / walls/ceiling for protection of UG cable complete all as specified and as directed.
Supply and fix LT under ground cable 1100 volts grade PVC /XLPE sheathed armoured multistranded heavy duty electric cable with aluminium conductor 3.5 core 70 Sqmm, laid in trenches/ duct / walls including cable gland on both termination where necessary including laying, connecting to various switches in panel board, testing and commissioning etc complete all as specified and directed.
M & L for spreading of riddled earth obtained from trenches for cable cushioning on top and bottom of cable as specified for cable protection complete all as specified and directed. (Note: Only punned thickness of riddled earth shall be measured)
Supply and fix double compression copper stainless steel gland for fixing armoured cable of size 3½ core 50 sq mm to 70 sq mm complete all as specified and directed.
Supply and fix double compression copper stainless steel gland for fixing armoured cable of size 3½ core 25 sq mm to 35 sq mm complete all as specified and directed.
Supply , installation, testing and commissioning of outdoor LT feeder pillar box panel board , CPRI Approved , made out of CRCA sheet 3.15 mm thick vermin proof factory made with 50 x 50 x6 mm MS angle/channel,front operated, roof canopy double door type including locking arrangement duly painted with two coats of synthetic enamel powder coated paint over a coat of metal primer with bus bar chamber comrising of high conductivity copper bus bar of capacity 320 Amps and netural 160 A current carrying capacity with PVC sleeves for phase indication, three phase 4 wire system,suitable adopter boxes with spreader link for connecting cables of switch terminal, PCC foundation, earth work etc suitable to accommodate the following as specied and as directed.:- INCOMING (a) MCCB 160 A, 4 pole with adjustable thermal and fixed magnetic setting breaking capacity 16 KA- 01 Nos. (b)On Load Change over switch 415V 4 pole - 160 Amps - 01 No (c) Metering unit-(R Y B) Indication LED type-01 Set, Multifunctional Meter - 01 No, CT-01set OUTGOING (a)MCCB 125 A, 4 pole with adjustable thermal and fixed magnetic setting breaking capacity 16 KA - 01 Nos (b) MCCB 63 A, 415V , 4 pole with adjustable thermal and fixed magnetic setting breaking capacity 16 KA - 01 Nos
sri manikandan enterprises
VVM CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .