Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹4.1 Cr
EMD Value
₹3.5 L
Closing Date
31 Jul 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
AGC ELC
18 conditions · 6 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' which ever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB(as per GCC April-2022), along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer shall submit Annual Contractual turnover Data for the Previous 3/4 Years (Contractual Payment only) as per Annexure-VI-B, otherwise the offer will be summarily rejected.
The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.
(a) The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii) One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway.
In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract, with prior approval of Chief Engineer in writing. Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Tenderer should submit valid 'A' class Electrical license from the specified authority on the date of opening of tender on which the name of firm should have clearly mentioned , other wise his offer will be summarily rejected.
The meaning of similar work for the above work is: "Any work of Wiring/rewiring of buildings with works of Street light and associated electrical works. AND/OR Supply, erection, testing and commissioning of LT/HT Panels or High masts lighting with associated cables laying work. OR Works of 6.6 KV/430V Sub-station and above".
79 conditions · 31 needing a document upload
The tenderer whether sole proprietor / a company or a partnership firm / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association /Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Appostille certificate.
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be. following documents shall be submitted by the tenderer:
a) Sole Proprietorship Firm: (i) All documents in terms of Para 10 of the Tender Form (Second Sheet)of GCC-2022.
(b) HUF: (i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC- 2022.
(c) Partnership Firm: (i) A notarized copy of the Partnership Deed or a copy of the Partnership deed registered with the Registrar. (ii) A notarized or registered copy of Power of Attorney in favour of the individual to tender for the work, sign the agreement etc. and create liability against the firm. (iii) An undertaking by all partners of the partnership firm that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP in which they were / are partners/members. Any Concealment / wrong information in regard to above shall make the bid ineligible or the contract shall be determined under Clause 62 of the Standard General Conditions of Contract. (iv) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC2022.
(d) Joint Venture (JV): i.The tender form shall be purchased and submitted only in the name of the JV and not in the name of any constituent member. The tender form can however be submitted by JV or any of its constituent member or any person authorized by JV through Power of Attorney to submit tender. ii.A copy of Memorandum of Understanding (MoU) duly executed by the JV members on a stamp paper, shall be submitted by the JV alongwith the tender. The complete details of the members of the JV, their share and responsibility in the JV etc. particularly with reference to financial, technical and other obligations shall be furnished in the MoU. iii. All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022
In case one or more of the members of the JV is/are partnership firm(s), following documents shall be submitted: (i) A notarized copy of the Partnership Deed or a copy of the Partnership deed registered with the Registrar. (ii) A copy of consent of all the partners or individual authorized by partnership firm, to enter into the Joint Venture Agreement on a stamp paper, (iii) A notarized or registered copy of Power of Attorney in favour of the individual to sign the MOU/JV Agreement on behalf of the partnership firm and create liability against the firm. (iv) An 2.4.1 undertaking by all partners of the partnership firm that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP in which they were / are partners/members. Any Concealment / wrong information in regard to above shall make the bid ineligible or the contract shall be determined under Clause 62 of the Standard General Conditions of Contract.
In case one or more members is/are Proprietary Firm or HUF, the following documents shall be enclosed: (i) A copy of notarized affidavit on Stamp Paper declaring that his Concern is a proprietary Concern and he is sole proprietor of the Concern OR 2.4.2 he who is signing the affidavit on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF.
In case one or more members of the JV is/are companies, the following documents shall be submitted: (i) A copy of resolutions of the Directors of the Company, permitting the company to enter into a JV agreement, (ii) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company 2.4.3 (iii) A copy of Certificate of Incorporation (iv) A copy of Authorization/copy of Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual, to sign the tender, sign MOU/JV Agreement on behalf of the company and create liability against the company.
In case one or more members of the JV is/are LLP firm/s, the following documents shall be submitted: (i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation of LLP (iii) A copy of resolution passed by partners of LLP firm, permitting the Firm to enter into a JV agreement (iv) A copy of Authorization /copy of Power of Attorney issued by the LLP firm (backed by resolution passed by the Partners) in favour of the individual, to sign the tender and/or sign the MOU/ JV agreement on behalf of 2.4.4 the LLP and create liability against the LLP. (v) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were / are partners/members. Any Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract.
In case one or more members of the JV is/are Society/s or Trust/s, the following documents shall be submitted: (i) A copy of Certificate of Registration (ii) A copy of Memorandum of 2.4.5 Association of Society/Trust Deed (iii) A copy of Rules & Regulations of the Society (iv) A copy of Power of Attorney, in favour of the individual to sign the tender documents and create liability against the Society/Trust.
(e) Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(f) LLP (Limited Liability Partnership): (i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation (iii) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were / are partners/members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet)of GCC-2022.
(g) Registered Society & Registered Trust: (i) A copy of Certificate of Registration (ii) A copy of Memorandum of Association of Society/Trust Deed (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (iv) A copy of Rules & Regulations of the Society (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
Tenderer may carefully note that their contract agreement for this work is liable to terminated at any time later, in case any of the information furnished by them is found untrue or any adverse points come to lights subsequently. The decision of railway in this regard shall be final and binding.
Shramik Kalyan portal:- As indicated in General Conditions of Contract that shall be adhered to by Tenderer.
Document Verification Certificate (Annexure-V(A)) in case of partnership firm/LLP/JV, Annexure-V(A) must be submitted by each, and every partner/member/firm otherwise offer will be summarily rejected. Annexure-V(A) (ACS no. 2 of GCC-2022).
Employment/Partnership etc. of Retired Railway Employees (As in Annexure1A):
(Annexure-1A)The tenderer will give full information as to the date of retirement of such Engineer or gazetted officer from the said service and as to whether permission for taking such contract, or if the Contractor be a partnership firm or an incorporated company, to become a partner or director as the case may be, has been obtained by the tenderer or the Engineer or officer, as the case may be from the President of India or any officer, duly authorized by him in this behalf, shall be clearly stated in writing at the time of submitting the tender, if a tenderer is - i) be a retired Engineer of the gazetted rank or any other gazetted officer working before his retirement, whether in the executive or administrative capacity or whether holding a pensionable post or not, in the Engineering or any other department of any of the railways owned and administered by the President of India for the time being, OR ii) being partnership firm / joint venture (JV) / registered society / registered trust etc have as one of its partners a retired Engineer of the gazetted rank or any other gazetted officer working before his retirement, OR iii) being an incorporated company have any such retired Engineer of the gazetted rank or any other gazetted officer working before his retirement as one of its directors AND in case where such Engineer or officer had not retired from government service at least 1 year prior to the date of submission of the tender.
b) In case, upon successful award of contract, should a tenderer depute for execution of the works under or to deal matters related with this contract, any retired Engineer of gazette rank or retired gazetted officer working before his retirement in the Engineering or any other department of any of the railways owned and administered by the President of India for the time being, and now in his employment, then the tenderer will ensure that retired Engineer or retired gazetted officer had retired from government service at least 1 year prior to the date of his employment with tenderer and in case he had retired from service within a year then he possesses the requisite permission from the President of India or any officer, duly authorized by him in this behalf, to get associated with the tenderer.
(c) Should a tenderer or Contractor being an individual, have member(s) of his family or in the case of partnership firm/ company / joint venture (JV) / registered society / registered trust etc. one or more of his partner(s)/shareholder(s) or member(s) of the family of partner(s)/shareholder(s) having share of more than 1% in the tendering entity employed in gazetted capacity in the Engineering or any other department of the railway, then the tenderer at the time of submission of tender, will inform the authority inviting tenders the details of such persons.
Note:-If information as required as per a), b), c) above has not been furnished, contract is liable to be dealt in accordance with provision of clause 62 of Standard General Condition of Contract.
The tenderer shall upload scanned copies of mandatory credential such as Experience, Turn over certificates and any other documents as applicable, all documents related to Partnership Deed/Joint Venture/ Consortium/ MOU, Registration details, TIN No., registered address, email ID etc. should be up loaded in PDF format only at the time of submission of bid.
The tenderer have to submit the declaration that: "I / We had not been black listed or debarred by Railway or any other Ministry /Department/ Public Sector under taking of the Govt. of India/ State Govt. from participation in tenders/ contracts on the date of tender opening of bids, either in individual capacity or as a member of JV firm." Non submission of the certificate, shall lead to summary rejection of the offer.
(Annexure-2):In case of Partnership firm/LLP/JV, An undertaking by all partners, that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any 7.1.1 firm/LLP in which they were / are partners/members. Any Concealment / wrong information in regard to above shall make the bid ineligible or the contract shall be determined under Clause 62 of the Standard General Conditions of Contract. (Annexure-2)
Before submitting a tender, the tenderer will be deemed to have satisfied himself by actual inspection of the site & locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all inclusive to accord with the provisions in Clause - 37 of the Standard General Condition of Contract for the completion of works to the entire satisfaction of the Engineer. Please Confirm and upload of ANNEXURE- 4 (DECLARATION FOR SITE VISIT) of tender booklet with the offer.
Credentials of Tenderers: The tenderers shall provide satisfactory documentary evidences acceptable to Railway (certificate from private individuals for whom such works are executed / being executed will not be accepted) along with the tender to show that:
They have an established technically competent and adequate staff organization to ensure that the services required under this tender can do satisfactorily. The Tenderer shall provide the list of personnel available in hand and proposed to be inducted for the subject work along with the offer.
They have sufficient equipments; plants and machinery to meet the obligations under the contract and to complete the work contract all within the stipulated time schedule and accepted by him. The Tenderer shall provide the list of equipments, plants and machinery available in hand and proposed to be inducted (own and hired basis separately) for the subject work along with the offer.
The Tenderer should submit the details of all similar works done in the past.
The Tenderer should submit the attested copies of the certificates obtained from the agencies wherever the works have completed successfully. These certificates should indicate the details of installation and successful commissioning of the similar type of equipments executed by the Tenderer.
The Tenderer will submit, along with offer list of work in hand indicating description of work, contract value, approximate value of balance work yet to be done and date of award of work.
They have adequate financial resources to meet the obligations under the contract. They have to submit the report from recognized bank or financial institutions.
Please submit your bank details i.e.Name of the Bank along with Bank Branch Code, IFSC Code, Beneficiary name, Account Number, Type of account, PAN and GSTN Number.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
INSTRUCTIONS TO TENDERERS
The tenderer shall thoroughly go through the entire tender documents and strictly adhere the instructions and directions given at different pages.
If the Tenderer(s) deliberately give(s) wrong information/ incorrect documents in his/their tender or create circumstances for the acceptance of his/their tender, the Railway reserves the right to reject such tender at any stage. The entire EMD and any other dues available with Railway against that contract will be forfeited. Action will be taken to suspend the business with the tenderere for a period of one year. In addition, Administration reserves the right to prosecute under suitable law.
All terms and conditions in the tender documents are binding on the Tenderers.
The Tenderers are advised to visit the site of work in their own interest and acquaint themselves with the site conditions and expected quantum of work and assess all the site specific difficulties to be experienced while executing the same and the rate shall be arrived duly considering all the facts above and quoted in the tender. Any representation at a later date specifying the site difficulties shall not be considered.
It shall not be obligatory on the said authority to accept the lowest tender and no Tenderer/tenderers shall demand any explanation for the cause of rejection of his/their tender.
The authority for the acceptance of the tender will rest with the Dy.CEE/C/AGC/NCR, North Central Railway who does not bind himself to accept the lowest or any other tender nor does he undertake to assign reasons for declining to consider any particular tender or tenders.
The special condition of tenders and contracts & the General Condition Contract should be considered a part contract agreement documents. Where the provisions of these conditions are at variance with the general conditions of the contract, the special conditions shall prevail.
Tenderers are advised to go through the tender booklet for detail condition, scope of work and other technical conditions/specification, maintenance schedule, all penalty conditions, make list, earthing drawing, approved/likely source of material related with the work before submitting their offer.
The Tenderer/Tenderers shall quote his/their rates with reference to each item and must tender for all the item shown in the attachment schedule. The quantities shown in the attached schedule are giving as guide and are approximate only and are subject to variation according to the need of Railway. The Railway accepts no responsibility for their accuracy the railway does not guarantee work under each item of the schedule.
The tenderer shall hold the offer open up to 60 days within which period the tenderer cannot with draw his offer subject to the period being extended further if required by mutual agreement from time to time. Any contravention of the above condition will make the tenderer liable for banning from submission of bids in any Works / Service Tender issued by Indian Railways for a period of 12 months from the date of such banning done on e- platform IREPS. It is understood that the tender document have been sold/issued to the tenderer and the tenderer is being permitted to tender in consideration of the stipulation on his part that after submitting his tender, he will not resile from his offer or modify the terms and conditions therefore in a manner not acceptable to the Dy.CEE/C/AGC/NCR
The successful Tenderer/Tenderers shall be required to execute an Agreement with the President India acting through the Dy. CEE/C/AGC/NCR of the Railway, for carrying out the work according to the general Conditions of Contract and Specification work and Materials of North Central Railway.
Security Deposit and Performance Guarantee:- As indicated in General Conditions of Contract/special conditions shall be adhered by Tenderer.
PERFORMANCE GURANTEE (PG) The procedure for obtaining Performance Guarantee is outlined below: (a) The successful bidder shall have to submit a Performance Guarantee (PG) within 21 (Twenty one) days from the date of issue of Letter of Acceptance (LOA). Extension of time for submission of PG beyond 21 (Twenty one) days and upto 60 days from the date of issue of LOA may be given by the Authority who is competent to sign the contract agreement. However, a penal interest of 12% per annum shall be charged for the delay beyond 21(Twenty one) days, i.e. from 22ndday after the date of issue of LOA. Further, if the 60thday happens to be a declared holiday in the concerned office of the Railway, submission of PG can be accepted on the next working day. In all other cases, if the Contractor fails to submit the requisite PG even after 60 days from the date of issue of LOA, the contract is liable to be terminated. In case contract is terminated railway shall be entitled to forfeit Bid Security and other dues payable to the contractor against that particular contract, subject to maximum of PG amount. In case a tenderer has not submitted Bid Security on the strength of their registration as a Startup recognized by Department of Industrial Policy and Promotion (DIPP) under Ministry of Commerce and Industry, DIPP shall be informed to this effect. The failed Contractor shall be debarred from participating in re-tender for that work.
b) The successful bidder shall submit the Performance Guarantee (PG) in any of the following forms, amounting to 3% of the original contract value:- (i) A deposit of Cash; (ii) Irrevocable Bank Guarantee; (iii) Government Securities including State Loan Bonds at 5% below the market value; (iv) Pay Orders and Demand Drafts tendered by any Scheduled Commercial Bank of India; (v) Guarantee Bonds executed or Deposits Receipts tendered by any Scheduled Commercial Bank of India; (vi) Deposit in the Post Office Saving Bank; (vii) Deposit 9.1.1 in the National Savings Certificates; (viii) Twelve years National Defence Certificates; (ix) Ten years Defence Deposits; (x) National Defence Bonds and (xi) Unit Trust Certificates at 5% below market value or at the face value whichever is less. Also, FDR in favour of Dy.FA&CAO/C/AGC/NCR (free from any encumbrance) may be accepted. Note:- As per RB policy no. 2020/CE-I/CT/3E/GCC/Policy dtd. 10.01.2022, PG amounting to 3 % of the original contract value will be applicable till 31.03.2023 and thereafter PG amount will be as per GCC April-2022.
The Performance Guarantee shall be submitted by the successful bidder after the Letter of Acceptance (LOA) has been issued, but before signing of the contract agreement. This P.G. shall be initially valid upto the stipulated date of completion plus 9.1.2 60 days beyond that. In case, the time for completion of work gets extended, the Contractor shall get the validity of P.G. extended to cover such extended time for completion of work plus 60 days.
The value of PG to be submitted by the Contractor is based on 9.1.3 original contract value and shall not change due to subsequent variation(s) in the original contract value.
The Performance Guarantee (PG) shall be released after physical completion of the work based on 'Completion 9.1.4 Certificate' issued by the competent authority stating that the Contractor has completed the work in all respects satisfactorily.
Whenever the contract is rescinded, the Performance Guarantee already submitted for the contract shall be encashed in addition to forfeiture of Security Deposit available with railway. The Engineer shall not make a claim under the Performance Guarantee except for amounts to which the President of India is entitled under the contract (not withstanding and/or without prejudice to any other provisions in the contract agreement) in the event of: (i) Failure by the Contractor to extend the validity 9.1.5 of the Performance Guarantee as described herein above, in which event the Engineer may claim the full amount of the Performance Guarantee. (ii) Failure by the Contractor to pay President of India any amount due, either as agreed by the Contractor or determined under any of the Clauses/Conditions of the Agreement, within 30 days of the service of notice to this effect by Engineer. (iii) The Contract being determined or rescinded under clause 62 of the GCC
The Performance Guarantee should be submitted in favour of Dy. FA&CAO/C/AGC/NCR.
The Railway administration reserve the right to reject any tender either in whole or in part without assigning any reason whatsoever. The final acceptance of the tender shall rest with the competent authority of Railway who reserve the right to accept or reject any tender without assigning any reason thereof and does not bind himself to accept the lowest tender only.
Price Variation Clause (PVC) in Works Contract is dealt in accordance with provisions of item 46A of GCC - 2022 and ACS NO. 1 to GCC 2022. Price Variation Clause (PVC) shall be applicable only in tender having advertised value above Rs. 2 Crores . Provided further that, in a contract where PVC is applicable, following shall be outside the purview of price adjustments (i.e. shall be excluded from the gross value of the work for the purpose of price variation)
Description of the work "Electrification of various services buildings, Approach Road, Quarters, LC Gates etc. in AF-BKI Section in Connection with AF-BKI (150 Km) work of Agra Division of North Central Railway".
AGC-EL-C-T-12R-2024-25
AGC-EL-C-T-12R-2024-25
Open
Works - General
12 Months
Prayagraj, Uttar Pradesh
₹0
₹3.5 L
31 Jul 2025
9 Jul 2025
207 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 4,06,33,470.94 | ||
| — | 1600.00 | — | — | ||
| A complete indoor type LED tube light fitting 1X18/20 watt complete with 4 feet LED tube, lighting unit consisting of a light source and driver to together with parts of distribute light, to position and protect the light source, and to connect the light source to a branch circuit. The light source itself may be an LED array and LED module, or an LED Lamp. Supply LED luminaries shall conform to IS:16101(2012), IS: 16106(2012) or latest. | — | — | — | 7,77,376 | |
| — | 800.00 | — | — | ||
| "Supply, erection, testing and commissioning of 4 5 watt Street light LED fittings, pressure die cast Aluminium housing, reflector and enclosed with toughened glass, IP-65/66. Complete with suitable size G.I. Bracket and all other accessories required as per site. " | — | — | — | 40,90,472 | |
| — | 30.00 | — | — | ||
| "supply, erection, testing and commissioning of integrated 30W LED Solar Street Light (LED based) consist of white LED luminaire ( LED + Driver) rating as per configuration along with Solar PV modules and LiFePo4 battery of given capacity, necessary control electronics, interconnecting wires / cables, module mounting structures, etc. to operate from dusk to dawn, PV MODULE Type of PV Module Only indigenous modules of IEC Tested used. Crystalline high power/efficiency cells used in the solar photovoltaic module Power output of PV Module 75 Wp at 16.4 ±0.2 Volt at STC PV Module Efficiency 14%. The open circuit voltage of the PV modules under STC (in volts) 21 Certification /Report Certified by MNRE/NABL authorized test center as per latest edition of IEC 61215 edition II / IS 14286. BIS CRS compliance for PV Module as per IEC 61215 Edition II / BIS 14286 from NABL or IECQ accredited Laboratory Mnimum warranty period for PV Modules (in Years) PV module warranted for output wattage 90% at the end of 10 years and 80% at the end of 25 years, Type of Battery Lithium Ferro Phosphate battery (LiFePo4). Operating from dusk to dawn first four hour full brightness, rest of the time at lower level, with motion sensor Battery capacity 12.8 V (nominal), 30 Ah at STC (2 day autonomy) Cycle/ Current Battery cycle life 2000 cycle at 80 % discharge, Type of LED (Light source) 30 Watt White LED type LED chip Efficacy (Lumen/watt) 135 Luminaire System Efficacy - Lumen output - (Lumen/watt) 120, The color temperature of white LEDs used in the system 5500 degree K - 6500 degree K., The temperature of heat sink 20 degree centigrade above ambient temperature during operation CRI > 70 % Lighting quality Free from glare, flickering and UV Wattage Power consumption of the LED Luminaire / lighting unit 30W (including LED and Driver power loss) Ingress protection IP65 or better, Provision on frame structure Frame structure have provision that the module can be oriented at the suitable tilt angle Conformity of the specification for Steel tube for street light pole as per IS:1161:2014 latest, Hot dip galvanized condition the zinc coating on the tubes as per IS:4736 latest, Nominal bore size of tube / Thickness of tube 75 mm / 3.2 mm Height of pole (in m) 6, Battery box Battery included in the luminaire enclosure, with water proof (IP65 or better) and corrosion resistant | — | — | — | 4,86,942 | |
| — | 50.00 | — | — | ||
| "Supply,Erection, testing & commissioning of energy efficient LED street light luminary 60-70 Watt capacity with luminous efficacy greater than equal to 100 made from pressure die cast aluminum housing, toughened front glass cover, fitted with secondary optics, heat sink and integrated electronic driver for long life with IP 65/66 Protection suitable for working on 240 Volt, 50 Hz AC supply. The price shall also cover for fixing, testing and commissioning of the above fitting on pole/truss/ roof/ wall by fabrication by suitable clamp/ bracket made/pipe from G.I. flat of 40 x 6 mm approx. duly painted with nut, bolts and washers of 12 mm diameter as per site requirement. The connection shall be carried out through ISI marked, PVC insulated,flexible three-core copper wire from the existing ceiling rose /catenaries/ junction box as per site conditions. The connection cord shall be protected by suitable size of heavy duty flexible PVC conduit. | — | — | — | 1,93,413 | |
| — | 300.00 | — | — | ||
| Supply erection testing and commissioning of LED lamp 10W make:-Bajaj,Havell,s, Osram,Phillips. | — | — | — | 47,463 | |
| — | 350.00 | — | — | ||
| "Supply, Erection, Testing & Commissioning of 5 star rated super energy saving efficient BLDC Ceiling Fan, sweep size 1200mm., down rod length as per site requirement, power factor greater than 0.98 with Electronic Regulator & double ball bearing and MS Flat size 50 X 5mm clamp of suitable size with hanging hook, nut bolt washer etc & Connection shall be taken with twin cord flexible PVC insulated copper wire size 48/0.2 mm., 03 blades of Aluminium with power consumption not more than 28 Watt, Warranty 03 years, required make - RR, Havells, Crompton, Bajaj bee 5 star rated BLDC super energy efficient ceiling Fan with double ball bearing, power 28 W. " | — | — | — | 10,94,726.5 | |
| — | 200.00 | — | — | ||
| Supply, Erection, Testing and Commissioning & fixing BLDC Electric Ceiling Fan,1400 mm sweep ,along with minimum air delivary 220 cu. meter/min,5 star rating complete with down rod as per suitable length,electronoic regulator/remote ,Fan hook with flexible copper cable with PVC pipe. with max power consumption 35W & Remote control for rest houses. | — | — | — | 6,45,438 | |
| — | 70.00 | — | — | ||
| "Supply erection testing and commissioning of exhaust fan 380 mm sweep 1400 RPM Four blade suitable to work on 230 volt AC supply it should be fixed on wall with reg bolt nut washer etc, " | — | — | — | 2,17,994.7 | |
| — | 40.00 | — | — | ||
| "Supply, erection, testing and commissioning of 225 mm sweep exhaust fan suitable on 230 volt AC, single phase complete with all other accessories required as per site. " | — | — | — | 51,330.8 | |
| — | 20.00 | — | — | ||
| "supply, Erection, testing and commissioning of Air circulating fan 600 mm sweep single phase 50HZ AC 230 V, heavy duty oscillation type propeller fan available with impeller consisting of 03 blades column mounting connecting from sealing rose/ bus bar by 2.5 sqmm multi- strands copper wire through PVC flexible pipe (asa per IS 2997/1964 or latest) " | — | — | — | 1,27,794.6 | |
| — | 30.00 | — | — | ||
| "wall mounted fan i.e (Supply erection, testing & commissioning of wall mounted fan 400 mm sweep single phase, 50Hz, 230 Volt AC complete with all other fixing accessories required as per site.)" | — | — | — | 74,427.6 | |
| — | 2000.00 | — | — | ||
| "Supply of material and making wiring /rewiring of various points such as FT fittings/ ceiling fans/ordinary light point with 2.5 sq mm PVC insulated, multi stranded copper conductor cable single core conforming to IS 694 [latest version] on surface PVC Casing capping channel heavy duty /in recessed PVC Conduit pipe heavy duty [ISI Mark] with bakelite batten holder /angular holder/ceiling rose, 5A Flush type/modular switch, white phenolic laminated sheet cover on front of recessed , MS box of suitable size with brass screw cup washer etc, including earth continuity copper wire of 1.5 sq mm PVC insulated copper wire compleed, [ note-the wire from SDB to switch board shall be of 4 sq mm PVC insulated copper wire one 5A/ 5 Pin flush type socket with 5A Switch shall also be provided on each switch boards. " | — | — | — | 11,50,660 | |
| — | 200.00 | — | — | ||
| "Supply of materials & making wiring points of 5 pin 5A plug socket with 2.5 sqmm PVC insulated multistranded copper conductor cable single core conforming to IS : 694 (latest version) in recessed/ on surface (As per site requirment) . On surface PVC casing capping channel heavy duty 2mm thickness double locking / in recessed PVC conduitpipe heavy duty 2 mm thickness ISI mark with 5A Modular switch , modular sheet cover on front of in recessed MS box /On surface modular box with brass screws, cup washers etc including earth continuity copper wire of 1.5sqmm PVC insulated copper wire complete. " | — | — | — | 27,108 | |
| — | 14.00 | — | — | ||
| "Supply of materials & making wiring points for mobile charging with 2.5 sqmm PVC insulated multi stranded copper conductor cable single core conforming to IS : 694 (latest version) on surface PVC casing capping channel heavy duty / in recessed PVC conduit pipe heavy duty (ISI mark) with Bakelite batten holder /angular holder / ceiling rose , 5A flush type switch , white phenolic laminated sheet cover on front of recessed MS box of suitable size with brass screws, cup washers etc including earth continuity copper wire of 1.5 sq.mm PVC insulated copper wire. 01 Board contain 04 Nos mobile charging points with ON/OFF switch. The mobile charging points should be apart at a suitable distance on the single board complete with suitable stand for holding of mobile set etc. " | — | — | — | 4,517.8 | |
| — | 200.00 | — | — | ||
| "supply of material and making wiring point of 6 pin combined power point 5A/15A with wiring by 4 sq mm PVC insulated, multi stranded copper conductor cable single core conforming to IS 694 [latest version] PVC Casing capping channel heavy duty with 15A Flush type switch, on front of hylum sheet top , MS box of suitable size with brass screw cup washer etc, completed earth continuity wire, [note- the wire from SDB to switch boards shall be of 4 sq mm copper wire with 1.5 sq mm copper earth wire], " | — | — | — | 1,65,824 | |
| — | 20.00 | — | — | ||
| "Provision of meter board box comprising with 5-60A, single phase electronic meter etc " | — | — | — | 32,480.2 | |
| — | 4000.00 | — | — | ||
| "Supply, erection, testing and commissioning of sub main 2x6 sq mm. PVC insulated sheathed copper wire, multi strands, 1100 volts grade, continues PVC insulated sheathed copper earth wire of 1.5 sq mm, through PVC heavy duty conduit pipe/PVC Channel complete with all other accessories required as per site . " | — | — | — | 3,25,080 | |
| — | 4500.00 | — | — | ||
| supply, Erection, testing and commissioning of 1 X 10 sqmm. Copper PVC cable including binding with insulation with binding wire, clamps etc as per latest IE rule. | — | — | — | 4,63,185 | |
| — | 3000.00 | — | — | ||
| "Supply of 2X10 sq mm PVC Insulated copper cable single core 1100 volt grade as per IS 694 [latest] for sub-mains with PVC conduit pipe heavy duty not less than 25 mm dia recessed /surface of the wall with earth continuity PVC copper Wire 1.5 sqmm including erection testing and commissioning . " | — | — | — | 3,57,720 | |
| — | 1000.00 | — | — | ||
| "Supply of 4X10 sq mm PVC Insulated copper cable single core 1100 volt grade as per IS 694 [latest] for sub-mains with PVC conduit pipe heavy duty not less than 25 mm dia recessed /surface of the wall with earth continuity PVC copper Wire 1.5 sqmm including erection testing and commissioning . " | — | — | — | 2,20,730 | |
| — | 20.00 | — | — | ||
| Supply, Erection, Testing and Commissioning of Door bell (Musical bell) | — | — | — | 1,919.4 | |
| — | 6000.00 | — | — | ||
| Supply, Erection, Testing and commissioning of MS/PVC conduit pipe 25/32 mm dia and 1.6mm thick, recessed in the wall and through the wall by making hole and replastering the same in original condition complete with Tee, elbow,junction box, sadle & Other accessories for submain wiring. (Item Directory - Not Applicable) | — | — | — | 2,61,360 | |
| for details. | Breakup | — | — | ||
| Supply of following way prewired factory fabricated powder coated sub distribution board on surface / recess double metal door completed with tinned copper bus- bar neutral /earth link, din channel, terminal block for termination of conductor of minimum 65 sq mm detachable gland plate, inter connection ,blanking plate for blank MCB suitable for incorporating MCB RCCB , MCCB including inter connection in DBs with copper conductor testing commissioning and earthling but excluding MCCB and MCBs, . | — | — | — | 2,31,494.5 | |
| for details. | Breakup | — | — | ||
| Supply of MCB/MCB Isolator single pole /double pole /tripple pole /Four pole of following rating in MDB/SDB Specified above completed with connection testing and commissioning, | — | — | — | 2,38,043.6 | |
| — | 80.00 | — | — | ||
| "Supply, fixing, testing & commissioning of hot dip galvanized octagonal pole 5 mtr. Long conf to IS 2629/BSEN-ISO 1461 Or equivalent including casting, muffing, with cement concert foundation(1:2:4) etc The pole shall be complete with holes, anchor bolts, bottom plate etc. As per Tech spec/site requirement IS/IE rules of following type.Weight of the pole should not be less than 40 Kg Double arm type with 1.5 to 2.0 feet long(Weight 6.5 Kg). " | — | — | — | 7,73,549.6 | |
| — | 500.00 | — | — | ||
| Supply, fixing, testing & commissioning of hot dip galvanized octagonal pole 5 mtr. Long conf to IS 2629/BSEN-ISO 1461 Or equivalent including casting, muffing, with cement concert foundation(1:2:4) etc The pole shall be complete with holes, anchor bolts, bottom plate etc. As per Tech spec/site requirement IS/IE rules of following type.Weight of the pole should not be less than 40 Kg Single arm type with 1.5 to 2.0 feet long(Weight 5.5 Kg). | — | — | — | 41,81,710 | |
| — | 200.00 | — | — | ||
| "Supply and erection of single earth electrode of 50 mm dia GI Pipe 3 mtr long B Class conforming to IS 1239 latest completed with earth box with cover as per RDSO approved drawing including connection from earth electrode to MDB/SDB/Poles with 8 SWG, GI wire. " | — | — | — | 4,62,464 | |
| — | 400.00 | — | — | ||
| Supply, erection and connection of GI strip of Size 25 X 3 mm as per IS 3043/1987 (latest version) 300 mm deep in ground/recessing in floor, clamping in trench. | — | — | — | 2,72,432 | |
| — | 200.00 | — | — | ||
| "Supply, erection, testing and commissioning of maintenance free earthing kit consisting of earth electrode copper bonded of 1800 mm, long,17.2 mm dia and copper bonding .Thickness of 250 microns (2nos.) thread less compressed type coupler, earth enhancing compound , copper tape 25x 6 x 300 mm and 25x6x150 mm terminate on earth electrode and cadmium bronze cable/copper cable of 3/16"" to connect bus bar 10 Mtr. each earth complete with digging of earth jointing of electrode etc. " | — | — | — | 20,89,060 | |
| — | 20000.00 | — | — | ||
| Excavation of cable trench in soft morrum plain ground concrete/pucca surface etc and back filling of cable for laying of HT/LT cables including placing of bricks in cross position in cable markers etc. | — | — | — | 15,34,000 | |
| — | 50.00 | — | — | ||
| RCC pipe (Excavation of cable trench 1000 mm deep and back filling in all type of soil under the track/road for laying of the cable including the work of supply and placing of RCC Hume pipe 150 mm internal dia with necessary RCC collars ,etc for drawing the cable in trench under the track/road) | — | — | — | 10,643 | |
| — | 400.00 | — | — | ||
| "Construction of cable trench for U/G cable with 700 mm deep and 500mm width cable trench made of brick masonry. This includes supply of all materials erection, commissioning of cable & trench etc. " | — | — | — | 3,39,296 | |
| — | 2000.00 | — | — | ||
| "Excavation of Cable Duct by Horizontal Boring Method 1.4 to 2.1 Meter Depths from the ground level for Track Crossing and Laying of 120 MM Outer Dia DWC/HDPE Pipe, The work Shall be done as per Extent Practice and Instruction of Site Engineer, it includes Supply of DWC / HDPE Pipes Confirming to IS 14930, ( Part - 2, of 2001) ( Rex. Poly Extrusion or Similar, " | — | — | — | 26,67,020 | |
| — | 100.00 | — | — | ||
| "Supply and erection of HDPE pipe of 160 mm internal dia having material grade PE- 100, wall thickness PN-6 and conforming to IS-4984 or latest as per IE rules and site requirement " | — | — | — | 70,585 | |
| for details. | Breakup | — | — | ||
| Supply, Erection, testing and commissioning of straight through cable jointing kit ,wraparound ,heat shrinkable type with all accessories for PVC/XLPE insulated alu cable 1.1 KV grade as per relevant IS specification of following sizes.(one set ST joint shall include all cores of cable at one end) | — | — | — | 2,90,820.65 | |
| for details. | Breakup | — | — | ||
| Supply and fixing of GI Pipe class B IS 1239 Part-I Latest with all fixing accessories for drawing the cable at support of following size- | — | — | — | 1,94,881.5 | |
| for details. | Breakup | — | — | ||
| Supply of material end termination of XLPE/PVC insulated LT cables following sizes with proper size of crimping socket lugs as required, [Note-One set termination shall included all cores of cables at one end], | — | — | — | 72,636.5 | |
| — | 18.00 | — | — | ||
| Supply erection commissioning of MDB suitable for outdoor weather proof floor /wall mounted type of suitable size made out of MS enclosure sheet 1.6 mm thick outside and 2.5mm thick centre plate with locking arrangement and indicators (main bus bar of MDB shall be of copper strip 300Amp cap.) | — | — | — | 2,40,839.82 | |
| — | 6.00 | — | — | ||
| Provision of Supply, Fixing, Testing, Connecting and commissioning of MCCB FP 400 A, 36KA | — | — | — | 1,48,611.78 | |
| — | 24.00 | — | — | ||
| "Provision of Supply, Fixing, Testing, Connecting and commissioning of MCCB FP 200A . 36 KA " | — | — | — | 4,91,264.16 | |
| — | 36.00 | — | — | ||
| Provision of Supply, Fixing, Testing, Connecting and commissioning of MCCB FP 125A/100, 36 kA | — | — | — | 2,25,515.88 | |
| — | 60.00 | — | — | ||
| Provision of Supply, Fixing, Testing, Connecting and commissioning of MCCB FP 63 A, 36 KA | — | — | — | 3,33,893.4 | |
| — | 15.00 | — | — | ||
| "SETC of Wall mounted Sub Distribution board TP&N vertical 8 way (8+24) wall mounting type dust and vermin proof indoor type factory fabricated from sheet steel enclosure (1.6mm thick ovory colour) fitted with double door copper busbar, neutral link, earthi terminal detachable glands fitted with following item SDB make as per attached standard list) 01 no. 125 Amp MCCB-FP -For main 08 Nos. 40/25 Amp MCB-DP on outgoing side" | — | — | — | 6,23,491.8 | |
| — | 15.00 | — | — | ||
| "Timer for 2 AC unit " | — | — | — | 58,382.25 | |
| — | 45.00 | — | — | ||
| "Provision of Supply, Fixing, Testing, Connecting and Commissioning of AC power point 20Amp. With 20Amp. MCB with 6 sqmm Copper wiring . " | — | — | — | 61,255.8 | |
| — | 10.00 | — | — | ||
| "Supply of Self contained Drinking Water cooler with (Non-CFC refrigerant) energy efficient compressor Cooling cap. Litres/hrs: 150type storage cap. 150, rate of max energy consumption 1550W make :- Usha, Blue star, Sidwal " | — | — | — | 4,68,768.7 | |
| — | 10.00 | — | — | ||
| Provision of V-Guard Electronic Voltage stabilizer 5 KVA, as per V-Guard model No. VEW WT-Meter capacity 15Amp working range 100-290V, Make Microtek Model EML 5090. | — | — | — | 70,171.9 | |
| — | 8.00 | — | — | ||
| "Storage water heater 15 Ltr. Cap. 1500 W (Make:-Havells,Racold, " | — | — | — | 46,649.36 | |
| for details. | Breakup | — | — | ||
| Supply Erection, Testing & Commissioning of heavy duty UPVC column pipe for submersible pupms, Type super heavy, effective length 3 m, both end threaded and one end fitted with threaded socket and rubber seal, effective length 3m Per pipe with all fixing accessories with following dia | — | — | — | 1,72,720.4 | |
| — | 300.00 | — | — | ||
| "Supply of submersible PVC insulated steel wire rope, Breaking strength not less than 2.50 KG/F. " | — | — | — | 10,980 | |
| — | 35000.00 | — | — | ||
| "Laying/Cleating of LT cable 03/04 core on wall with all accessories. (Cable will be supplied by Rly. Free of cost at consignee depot) " | — | — | — | 12,55,450 | |
| — | 15.00 | — | — | ||
| "Supply, Erection, testing and commissioning of Triple Pole with neutral link 415V 50 Hz with HBC cum rewirable porcelain fuse units (w/o Fuse link) 100 Amp. " | — | — | — | 1,28,909.25 | |
| — | 4.00 | — | — | ||
| "Supply, Erection, testing and commissioning of 63 Amp. FP Change over switch " | — | — | — | 27,692.92 | |
| — | 30.00 | — | — | ||
| "Supply and erection and providing of stay set to rail poles completed with CC foundation in ratio 1;3;6 stay set rod, stay tightner, stay insulator, stay GI wire,7/10 SWG thimble and other fixing accssories as required. This item is requred for support of OH line. " | — | — | — | 31,863 | |
| — | 180.00 | — | — | ||
| "Supply and Erection of RS Joist of 175x85 mm of (19.6 kg/m) and 9m long with Earth Coil. " | — | — | — | 27,75,189.6 | |
| — | 45.00 | — | — | ||
| Supply and Erection of H Beam of 152 x 152 mm of [37.1Kg / Meter] and 11 Meter Long along with earth coil , Erection includes excavation of earth and casting of foundation with cement concrete 1:3:6 with 40 mm Graded stone and painting of H-beam with one coat of red oxide paint and two coat of aluminum paint, the bottom of Hbeam [2.0 meter approx. to be painted with black paints]. | — | — | — | 12,04,283.7 | |
| — | 3000.00 | — | — | ||
| "Supply, Erection, Testing and Commissioning of LT XLPE Insulated aerial Bunched Cable [ABC] of size [3x120 + 1x95+1x16 ]Sq MM with insulated Messenger wire As per IS - 14255- 1955 or Latest, " | — | — | — | 9,67,770 | |
| — | 60.00 | — | — | ||
| "Supply, Erection, Testing and Commissioning of LT shackle insulator with nut and bolt and other accessories required as per site, " | — | — | — | 3,027 | |
| — | 20.00 | — | — | ||
| "Supply, Erection, Testing and Commissioning of shackle strip in size 12 inches with other accessories required as per site, " | — | — | — | 1,769.8 | |
| — | 150.00 | — | — | ||
| "Supply, Erection, Testing and Commissioning of I Hook with other accessories required as per site, " | — | — | — | 13,404 | |
| — | 40.00 | — | — | ||
| "Supply, Erection, Testing and Commissioning of dead ended clamp and other accessories required as per site, " | — | — | — | 21,357.6 | |
| — | 150.00 | — | — | ||
| "Supply, Erection, Testing and Commissioning of suspension clamp and other accessories required as per site, " | — | — | — | 65,917.5 | |
| — | 400.00 | — | — | ||
| "Supply and Erection of piercing connector for LT XLPE AB cable " | — | — | — | 55,656 | |
| — | 60.00 | — | — | ||
| "Supply, Erection, Testing and Commissioning of spring loaded CP multiconnection Bus Bar in Insulated Box suitable for Single phase 1 in 6 outgoing Distribution box for fixing on Pole for AB XLPE cable " | — | — | — | 42,375.6 | |
| — | 10.00 | — | — | ||
| "Supply & erection of Spring loaded CP multi connection busbar in insulated box suitable for three phase 1 in 3 outgoing distribution box for fixing on pole for AB XLPE cable. " | — | — | — | 10,470 | |
| — | 200.00 | — | — | ||
| "Supply, Fabrication, cutting and erection of channel ISMC 100 x 50x6 mm complete with Ms clamp, fixture, hot dipped galvanized nuts, bolts, washer of suitable size.The size of nut/bolt shall not be less than 12 mm, confirming to relevant ISS latest. " | — | — | — | 68,150 | |
| Each Span | 50.00 | — | — | ||
| Dismantling of Existing LT /HT /ABC Over Head Line with Conductor, Fittings, GI Brackets including Cutting of various types of Pole wherever required as per Site Condition | — | — | — | 16,782 | |
| — | 18000.00 | — | — | ||
| Handling / Leading / Loading and Unloading and Transportation of Railway Supply / Railway Released GPS Materials, LT/HT Over Head Line, Conductor, Pole etc. | — | — | — | 1,45,980 | |
| — | 12.00 | — | — | ||
| Provision of Hiring of Non-Ac multiutility 4 wheeler diesel driven, Vehicle moto, Tata Sumo(Victa),Innova or similar with commercial registration including driver, fuel, crew and Maintenance site supervisor and Toll Taxcharge etc. (Limit up to 3000 Km. per month) | — | — | — | 5,63,703 | |
| — | 200.00 | — | — | ||
| supply & erection of power coated perforated cable tray 300x50x1.6 mm thick for protection of cabes complete with all other accessories as per site requirement ( for supply arrangement through FOB and COP) | — | — | — | 92,112 | |
| — | 2000.00 | — | — | ||
| Supply, erection, testing and commissioning of sub main 2x4 sq mm. PVC insulated sheathed copper wire, multi strands, 1100 volts grade, continues PVC insulated sheathed copper earth wire of 1.5 sq mm, through recessed PVC heavy duty conduit pipe/PVC Channel complete with all other accessories required as per site .Note:-Normally it will be recessed type wiring and in exceptional circumstnaces based on site conditions surface casing capping channel wiring may be permitted with the approval of DyCEE/C/AGC only. | — | — | — | 1,17,160 | |
| — | 200.00 | — | — | ||
| Supply and Provision of Cable Route Marker | — | — | — | 33,748 | |
| — | 200.00 | — | — | ||
| Making of Horizontal Boring to track formation below 3.0 Meter from ground Level including DWC HDPE Pipe of or up to 200 mm dia. In critical case Hard rock as per site condition and in consultation with site supervisor. | — | — | — | 13,71,228 | |
| — | 3000.00 | — | — | ||
| Supply, Erection, Testing and Commissioning of LT XLPE Insulated aerial Bunched Cable [ABC] of size [3x50 + 1x35+1x16 ]Sq MM with insulated Messenger wire As per IS - 14255- 1955 or Latest, | — | — | — | 8,22,900 | |
| — | 300.00 | — | — | ||
| Supply & Erection of DWC/ HPDE pipe of 2.5'' dia for crossing railway track/platform. | — | — | — | 76,818 | |
| — | 50.00 | — | — | ||
| Supply & Erection of fencing Panel | — | — | — | 1,41,019 | |
| — | 1000.00 | — | — | ||
| Supply, fabrication cutting & fixing of MS channel /MS angle/ plate etc of on existing structure with suitable clamps & nut bolts etc. | — | — | — | 82,540 | |
| — | 200.00 | — | — | ||
| Supply,fixing,testing,connecting and commissioning of 2x18/20 watt complete LED fittings, Integral sleek extruded polycarbonate LED channel with white acrylic cover ) complete with all accessories including supply and fixing of 2x18/20 watt LED Lamp of make- Philips, Bajaj or Crompton Greaves directly or similar. on ceiling/wall and connection with twisted twin flexible cord of minimum size 16/0.2 mm copper conductor through flexible pipe as per relevant technical specification. | — | — | — | 1,38,792 | |
| — | 4.00 | — | — | ||
| Supply, installation & commissioning of 12.5 mtr motorised high mast with accessories ( as per specification attached in tender document ) | — | — | — | 7,53,695.68 | |
| — | 4.00 | — | — | ||
| Supply, installation & commissioning of foundation bolts including making foundation for high mast complete .( as per specification attached in tender document ) | — | — | — | 1,18,071.48 | |
| — | 4.00 | — | — | ||
| Supply, installation, testing and commissioning of twin dome aviation obstruction red light with two nos. incandiscent LED lamp of 9 watt .( as per specification attached in tender document ) | — | — | — | 10,202.84 | |
| — | 4.00 | — | — | ||
| Supply, installation, testing and commissioning of floor mounted outdoor feeder post for high mast ( as per specification attached in tender document ) | — | — | — | 1,01,243.36 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing and commissioning of digital timer 24 hrs/7days 16(6) amp with 2 (CO) changeover switching with multi programming to switch ON/OFF lights at preset time . ( as per specification attached in tender document ) | — | — | — | 9,812.2 | |
| — | 24.00 | — | — | ||
| Supply, fixing, installation & commissioning of weather proof LED floodlight luminaire complete 150watt, IP ratings 65 system efficiency (Im/W) 100, color temp (K) 5700, CRI 70, Housing LM6 high pressure die castaluminium, cover glass mounting wall/bracket, THD0.95, operating voltage 140-270 V AC 50 Hz . ( as per specification attached in tender document ) | — | — | — | 1,79,567.04 | |
| — | 50.00 | — | — | ||
| Supply, erection, testing &commissioning of (36-42) watt, 2'x2' LED panel light & fittings complete with required connecting wire and all other fixing accessories required as per site. | — | — | — | 1,66,561 | |
| — | 400.00 | — | — | ||
| "Design, Fabrication, supply,installation, testing andcommissioning of Glow Sign board Acrylic sheet , both sided 2 mm acrylicsheet with vinyl letters, covered with 2 mm unbreakable transparent sheet with rectengular box .Box made by Aluminum angle of 20 SWG with provision of 0.5 inch bidding of 22 SWG and LED module light with adapter suitable for LED light for input 110/220 voltsAC supply and box shall be made available for proper mounting arrangement on thewall/ceiling. Note:- The box shallbe made suitable arrangement for easy maintenance in future." | — | — | — | 5,35,280 | |
| — | 10.00 | — | — | ||
| Supply, erection, testing & commissioning of weather proof 100 Watt LED Flood light/Area light fittings with bracket, clamps (complete) IP ratings 65/66 and standard PVC flexible pipe, 2.5 sqmm wire for connection & 1.5 sqmm wire for earthing connection of the fittings. Complete with all other accessories required as per site | — | — | — | 50,975.5 | |
| — | 2.00 | — | — | ||
| Supply , Erection, testing ,and commissioning of electrically driven submersible pump set water lubricated , single phase 230 V , 50 Hz AC induction motor cap of 03 HP in bore well 100 mm/200 mm dia. , with all accessories. Discharge on/or within the range of 70 to 110 LPM total head on or within or upto the range of 68 to 100 mtrs. outlet 50mm water lubricated | — | — | — | 42,407.04 | |
| — | 5.00 | — | — | ||
| Supply, Erection, testing ,and commissioning of electrically driven Submersible pump set water lubricated , 3 phase 415 V ,50Hz AC induction motor cap of 5 HP in bore well 150mm/200mm dia. , with all accessories. Discharge on/or within the range of 62 to 180 LPM total head on or within or upto the range of 122 to 130 mtrs. outlet 50mm water lubricated. | — | — | — | 2,20,805.15 | |
| — | 7.00 | — | — | ||
| Supply, Erection, testing and commissioning of Reflux valve suitable for above pumps set complete with all other accessories required as per site | — | — | — | 23,026.01 | |
| — | 7.00 | — | — | ||
| Supply, installation, testing & commissioning of submersible pump starter panel in powder coated MS sheet enclosure with PU gasket suitable for above submersible pump motor. The panel should have star delta starter, MCB, ammeter & voltmeter with selector switch, ON/OFF & all trip indications. It should have protection against phase failure, phase imbalance, phase reversal, short circuit & Dry run etc.(upto 5HP pump) | — | — | — | 47,828.13 | |
| — | 300.00 | — | — | ||
| Supply, Erection, Testing and Commissioning of 2.5 Sq. mm, Water proof, Flat Submersible Copper Cable suitable for above Pump. | — | — | — | 24,387 | |
| — | 1000.00 | — | — | ||
| Supply, Erection, testing and commissioning of water proof flat submersible cable size not less than 06 sq.mm copper, 3 core to be laid from starter to motor of the pump. The cable should be laid through MS conduit pipe of heavy gauge from starter to bore. | — | — | — | 1,40,670 | |
| — | 200.00 | — | — | ||
| Supply,erection,testing & commissioning of12 mm multi-stranded, galvanized insulated & tested wire rope. | — | — | — | 8,624 | |
| — | 400.00 | — | — | ||
| Dismantling of exiting pole Rail pole/Tubular pole and Handing over the material to consignee depot. | — | — | — | 2,17,784 | |
| — | 6.00 | — | — | ||
| Supply Erection,Testing and commissioning of Solar Photovoltaic Modules/Panels- Crystalline silicon terrestrial with PV module rating (in Wp)330, Efficiency for PV modules >14% with corrosion resistant frame structure shall be provided to hold the PSV module and the terminal box on the module should have a provision for opening, for replacing the cable, if required PV module conforming to IEC61215/IS:14286 or latest as per site requirement | — | — | — | 63,496.68 | |
| — | 6.00 | — | — | ||
| Supply, Erection, Testing and commissioning of Solar Battery 12V 150AH Lead-Acid Batteries (With tubular positive plates) in Monobloc container conforming to IS 13369/1992 or latest. | — | — | — | 1,20,290.22 | |
| — | 6.00 | — | — | ||
| Supply, Erection, Testing and commissioning of Solar PWN charge controller, Solar panel cell material monopolycrystalline, Rechargable Battery Pack Voltage (in Volts) 12V, Charging capacity of battery charger up to and 2500 mAh, User selectable charging voltage 6V and 12V, Peak power, Nominal (in watts) 60W +/- 2W, peak power voltage while selected at 12 volt (in volts) 15 to 17, peak power current while selected at 12 volt (in A) 3.4 to 3.5, short circuit current while selected at 12 Volt (in A) 3.7, Peak open circuit voltage 20V +/- 2V with LED indications LED for charging and discharging state | — | — | — | 8,826.12 | |
| — | 24.00 | — | — | ||
| Supply, Erection,Testing and commissioning of LED bulb 7W ,12V DC Make:- Crompton, Philips, Havells, Bajaj & Wipro | — | — | — | 3,340.56 | |
| — | 6.00 | — | — | ||
| Provision of 12V DC Ceiling Fan 30W to 50W, 1200MM with all fixing accessories. | — | — | — | 19,786.32 | |
| — | 45.00 | — | — | ||
| Collection from DSK/JHS strore and Erection, fixing & commissioning of AC unit window type / split type 1.5/2.0 Ton 5 star rating complete with all other accessories including bracket as per site requirement | — | — | — | 1,63,113.3 | |
| — | 2.00 | — | — | ||
| Dismantling/shifting the existing lattice LED Light tower/High Mast | — | — | — | 57,665.14 | |
| — | 4.00 | — | — | ||
| Fridge single door (185 Litres) for construction deptt of Godrej,LG,Whirlpool,Samsung make or similar,BEE Star Rating should be 5 Star,Frost Free. It should have built in stablilizer with minimum warranty on product should be 1 year and warranty on compressor should be 10 year. | — | — | — | 70,800 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .