Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.6 LAccepted-AOC 13 218 MASJID EXTEN SADAR BAZAR | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹21.0 L+₹39,681.07 (1.93%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹25.4 L+₹4.9 L (23.7%)Rejected-Finance HOUSE NO 142 GALI NO 07 PREM VIHAR NANGLI SAKRAWATI NAJAFGARH NEW DELHI 110043 | NEW DELHI | NAJAFGARH | DELHI | 110043 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹26.9 L+₹6.3 L (30.5%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹28.2 L+₹7.6 L (36.9%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | verma enterprises L1 | M/S Davinder Kumar L2 | Deep Contractor L8 | Vijeta Solutions L5 | J V ENGINEERS / JAI SINGH L7 | PARAS ENTERPRISES L4 | S K ENGINEERS AND CONTRACTOR L3 | M/S ADHIKARI CONSTRUCTION CO. L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Supply, laying, testing and commissioning of XLPE insulated, armoured, heavy duty aluminium stranded conductor electric cable, 1100 volts grade, of the following sizes, laid in ground/pipes/walls/panels as directed including termination with proper lugs, fixing with clamps, complete with taking down old unserviceable XLPE cable all as specified and directed by Engineer-in-Charge. | |||||||||||
| 1.01 | 10 Sqmm x 2 Core | 1,050 | RM | 79 ₹82,950 | 80 ₹84,000 | 110 ₹1,15,500 | 179 ₹1,87,950 | 115 ₹1,20,750 | 85 ₹89,250 | 100 ₹1,05,000 | 59 ₹61,950 Lowest |
| 1.02 | 16 Sqmm x 2 Core | 1,000 | RM | 89 ₹89,000 | 90 ₹90,000 | 130 ₹1,30,000 | 199 ₹1,99,000 | 145 ₹1,45,000 | 75 ₹75,000 Lowest | 120 ₹1,20,000 | 79 ₹79,000 |
| 1.03 | 25 Sqmm x 3.5 Core | 1,000 | RM | 99 ₹99,000 Lowest | 100 ₹1,00,000 | 240 ₹2,40,000 | 279 ₹2,79,000 | 180 ₹1,80,000 | 152 ₹1,52,000 | 150 ₹1,50,000 | 129 ₹1,29,000 |
| 1.04 | 35 sqmm x 3.5 core | 300 | RM | 199 ₹59,700 | 150 ₹45,000 Lowest | 290 ₹87,000 | 329 ₹98,700 | 250 ₹75,000 | 185 ₹55,500 | 199 ₹59,700 | 189 ₹56,700 |
| 1.05 | 50 sqmm x 3.5 core | 300 | RM | 299 ₹89,700 | 250 ₹75,000 | 450 ₹1,35,000 | 445 ₹1,33,500 | 320 ₹96,000 | 245 ₹73,500 Lowest | 269 ₹80,700 | 249 ₹74,700 |
| 1.06 | 70 Sqmm x 3.5 Core | 100 | RM | 339 ₹33,900 | 300 ₹30,000 | 735 ₹73,500 | 550 ₹55,000 | 410 ₹41,000 | 310 ₹31,000 | 339 ₹33,900 | 299 ₹29,900 Lowest |
| 1.07 | 95 Sqmm x 3.5 Core | 200 | RM | 369 ₹73,800 | 350 ₹70,000 | 1,175 ₹2,35,000 | 767 ₹1,53,400 | 490 ₹98,000 | 310 ₹62,000 Lowest | 389 ₹77,800 | 399 ₹79,800 |
| 1.08 | 300 Sqmm x 3.5 Core | 120 | RM | 669 ₹80,280 | 550 ₹66,000 Lowest | 1,500 ₹1,80,000 | 2,070 ₹2,48,400 | 1,200 ₹1,44,000 | 1,200 ₹1,44,000 | 690 ₹82,800 | 699 ₹83,880 |
| 2.00 | Supply, installing, testing and commissioning in replacement of factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved, factory assembled Outdoor Feeder Pillar type, weather proof, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 300 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40 X 40 X 6 mm ), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including bocks of PCC 1:2:4 type B1 of block size 30x30x30 cm comprising of the following:-
BUS BAR CHAMBER :-
(a) 300 Amps 3 Strips & Neutral Strip 150 Amps, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.
INCOMING SUPPLY :-
(i) MCCB 200 Amps 36 KA 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz,=01 No., Make of MCCB:-L&T/ Schneider / HPL/ Havells.
INSTRUMENT FEEDER :-
(a) Digital Multi Function Meter with LED display for measurement of Voltage, current, frequency, Power Factor,
96 X 96 mm, 3 Phase- 01 Set.
(b) C.T's 200/5 A CL 1.0 Tape Wound- 01 Set. (Set of three)
(c) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three).
(d) Protection MCB 6 A SP C Series- 1 Set. (Set of three).
Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider. | 3 | Each | 89,999 ₹2,69,997 | 90,000 ₹2,70,000 | 65,000 ₹1,95,000 Lowest | 77,000 ₹2,31,000 | 1,25,000 ₹3,75,000 | 89,000 ₹2,67,000 | 99,000 ₹2,97,000 | 2,99,999 ₹8,99,997 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
2 Oct 2025, 6:00 pmClosed
GE South Delhi Cantt-10
GE South Delhi Cantt-10
REPAIR/MAINT OF UG CABLES, LT PANELS, SECURITY LIGHTS, GARDEN LIGHTS AND CONNECTED ACCESSORIES AT KHANPUR NORTH AND SOUTH ARMY CAMP UNDER AGE E/M OF GE(SOUTH) DELHI CANTT-10
2025_MES_729512_1
GE/TOKEN-70/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE South Delhi Cantt
As per Tender Documents
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹90,000
Yes
5 Dec 2025
4 Sept 2025
4 Oct 2025
4 Sept 2025
2 Oct 2025
18 Sept 2025
Amount
Supply, laying, testing and commissioning of XLPE insulated, armoured, heavy duty aluminium stranded conductor electric cable, 1100 volts grade, of the following sizes, laid in ground/pipes/walls/panels as directed including termination with proper lugs, fixing with clamps, complete with taking down old unserviceable XLPE cable all as specified and directed by Engineer-in-Charge.
10 Sqmm x 2 Core
16 Sqmm x 2 Core
25 Sqmm x 3.5 Core
35 sqmm x 3.5 core
50 sqmm x 3.5 core
70 Sqmm x 3.5 Core
95 Sqmm x 3.5 Core
300 Sqmm x 3.5 Core
Supply, installing, testing and commissioning in replacement of factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved, factory assembled Outdoor Feeder Pillar type, weather proof, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated Aluminium bus bars of 300 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, ingress protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel, Angle iron frame work made out of 40 X 40 X 6 mm ), front and rear opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR wire of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. embedded in ground with and including bocks of PCC 1:2:4 type B1 of block size 30x30x30 cm comprising of the following:- BUS BAR CHAMBER :- (a) 300 Amps 3 Strips & Neutral Strip 150 Amps, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INCOMING SUPPLY :- (i) MCCB 200 Amps 36 KA 4 Pole with Fixed thermal & magnetic release 415 volts , 50Hz,=01 No., Make of MCCB:-L&T/ Schneider / HPL/ Havells. INSTRUMENT FEEDER :- (a) Digital Multi Function Meter with LED display for measurement of Voltage, current, frequency, Power Factor, 96 X 96 mm, 3 Phase- 01 Set. (b) C.T's 200/5 A CL 1.0 Tape Wound- 01 Set. (Set of three) (c) Red, Yellow, Green Phase indicating Lights LED type 220 V AC- 1 Set. (Set of three). (d) Protection MCB 6 A SP C Series- 1 Set. (Set of three). Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider.
OUTGOING SUPPLY :- (i) MCCB 100 Amps 25 KA 3 Pole with Fixed thermal & magnetic release 415 volts , 50Hz - 04 Nos, Make of MCCB:- L&T/ Schneider / HPL/ Havells. The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011) 2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011) 3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk 4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V 5. ISO 9001 CERTIFIED Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC platform incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
OUTGOING SUPPLY :- (i) MCB SPN 32 Amps, 230 volts, 50Hz, rupturing capacity 10 KA C Curve = 6 Nos. Make of MCB:- L&T/ Schneider / HPL/ Havells. The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011) 2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011) 3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk 4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V 5. ISO 9001 CERTIFIED Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC platform incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Excavation, in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr in depth for laying cable in any type of soil and getting out complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick all as specified & directed by Engineer-in-Charge..
Removal of surplus excavated material to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for Sand cushioning to under ground cable with dry sand locally available 8cm thick before laying the cable and 15 cm above the cable, stretching and testing of cable complete all as specified & directed by Engineer-in-Charge.
Taking out old unserviceable / serviceable class 'B' bricks from excavated trenches all as specied and directed by Engineer-In-Charge. Note:- Serviceable class 'B' bricks kept in safe custody for reuse at site and unserviceable bricks to be through in low lying area.
Supply and laying sub class ‘B’ bricks well burnt for cable protections laid flat with length equal to width of brick over cable perpendicular to length of cable complete all as specified and directed by Engr-in-Charge
Laying only serviceable sub class ‘B’ bricks as retrieved from Srl item No 8 complete all as specified and directed by Engr-in-Charge.
M&L for cable jointing kit for 11 KV (Earthed) grade for outdoor termination end joint kit, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed by Engr-in-charge.
M&L for cable jointing kit for 11 KV (Earthed) grade for indoor termination end joint kit heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed by Engr-in-charge.
M&L for cable jointing kit for 11 KV (Earthed) grade for straight through, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed by Engr-in-charge.
M&L for providing and fixing Heat Shrinkable Straight Joint Kit suitable for 1.1 kV grade XLPE insulated aluminium conductor cable of following sizes, including taking down old unserviceable joint, complete with all accessories (heat shrink tubes, connectors, sealing, insulation, mechanical protection), testing and commissioning, all as specified and directed by Engineer-in-Charge.
25 sqmm to 50 sqmm size
70 sqmm to 150 sqmm size
185 sqmm to 300 sqmm size
Arranging fault locating machine to locate the fault in underground electric power cable of any length & any type of 11 KV/1.1 KV grade HT/ LT cables & pin point the fault, it also include testing of the cable after locating fault and cutting the cable at Fault to fix the joint including excavation and earth wotrk in any type of soil complete Note : Cable joint shall be measured and paid separately under respective of Sch 'A' (ii) If fault is not rectifed within 24 hours after receivng message , the contractor shall be charged penalty for Rs 500/- per Hours & the same has been deducred from his account during RAR
S&F in replacement of Moulded Case Circuit Breaker (MCCB), 4 Pole, 630 Amps, 50 kA breaking capacity, 415V, 50 Hz, with adjustable thermal and magnetic trip relay, including supply and fixing of suitable lugs, disconnecting and taking out old unserviceable MCCB from panel/DBs etc., testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
All as per item No 16 above but 400 amps 4 pole 36 KA Capacity 415V 50 Hz.
All as per item No 16 above but 250 amps 4 pole 36 KA Capacity 415V 50 Hz.
All as per item No 16 above but 200 amps 4 pole 36 KA Capacity 415V 50 Hz.
All as per item No 16 above but 160 amps 3 pole 36 KA Capacity 415V 50 Hz.
All as per item No 16 above but 100 amps 3 pole 16 KA Capacity 415V 50 Hz.
S&F in replacement of old unserviceable Digital Voltmeter of range 0–500 Volts, suitable for LT Panel, including all necessary connections, testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable Digital Ammeter of range 0–630 Amps, suitable for LT Panel, including all necessary connections, testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable indication lamp( R,Y,B) for LT Panel complete all as specified and directed by Engineer-In-Charge.
S&F in replacement of LED Street Light Fitting, 45 Watt, highly efficient, made of pressure die-cast aluminium housing with individual lenses and toughened glass cover, complete with fixing arrangements including MS clamp, nuts, bolts, anchor fasteners, washers, wiring connections, testing and commissioning,with the following features all as specified and directed by Engineer-in-Charge. i) Luminaire Housing: Pressure die-cast aluminium, corrosion resistant, powder coated. ii) Light Source: 45 Watt high-power LEDs, cool white (CCT ≥ 5700K). iii) Luminous Efficacy: ≥ 110 lm/W. iv) Lumen Output: ≥ 4950 lumens. v) CRI: ≥ 70. vi) LED Life: ≥ 50,000 burning hours (L70 at 25°C). vii) Optics: Secondary lenses over individual LEDs with toughened glass protection. viii) Ingress Protection: IP65 or higher. ix) Electricals: Power factor ≥ 0.95, THD < 10%, system efficiency > 85%, operating voltage 140–270V AC, 50 Hz. x) Surge Protection: Built-in SPD, minimum 4 kV. xi) Mounting: Supplied complete with MS clamp, nuts, bolts, anchor fasteners, and washers for pole/surface fixing. xii) Compliance: As per IS/IEC standards.
S&F in replacement of LED Street Light Fitting, 60 Watt, highly efficient, made of pressure die-cast aluminium housing with individual lenses and toughened glass cover, complete with fixing arrangements including MS clamp, nuts, bolts, anchor fasteners, washers, wiring connections, testing and commissioning, with the following features all as specified and directed by Engineer-in-Charge. i) Luminaire Housing: Pressure die-cast aluminium, corrosion resistant, powder coated. ii) Light Source: 60 Watt high-power LEDs, cool white (CCT ≥ 5700K). iii) Luminous Efficacy: ≥ 110 lm/W. iv) Lumen Output: ≥ 6600 lumens. v) CRI: ≥ 70. vi) LED Life: ≥ 50,000 burning hours (L70 at 25°C). vii) Optics: Secondary lens over individual LEDs with toughened glass protection. viii) Ingress Protection: IP65 or higher. ix) Electricals: Power factor ≥ 0.95, THD < 10%, system efficiency > 85%, operating voltage 140–270V AC, 50 Hz. x) Surge Protection: Minimum 4 kV built-in SPD. xi) Mounting: Supplied complete with MS clamp, nut, bolt, anchor fasteners, and washers for pole/surface fixing. xii) Compliance: As per IS/IEC standards.
S&F in replacement of Building Security Light Fitting, 30 Watt LED type, suitable for mounting on peripheral surfaces of the building, complete with fixing arrangements including MS clamp, nuts, bolts, wiring connections, testing and commissioning, with the following features all as specified and directed by Engineer-in-Charge. i) Luminaire Housing: Pressure die-cast aluminium, powder coated, corrosion resistant. ii) Light Source: 30 Watt high-power LEDs, cool white (≥ 5700K), symmetric light distribution. iii) Luminous Efficacy: ≥ 110 lm/W. iv) Lumen Output: ≥ 3300 lumens. v) CRI: ≥ 70. vi) LED Life: ≥ 50,000 burning hours (L70 at 25°C). vii) Optics: Polycarbonate lens/cover with glare control. viii) Ingress Protection: IP65 or higher (dustproof and waterproof). ix) Electrical: System efficiency > 85%, power factor ≥ 0.95, THD < 10%, operating voltage 140V–270V AC, 50 Hz. x) Surge Protection: Built-in SPD (minimum 4 kV). xi) Mounting: MS clamp with nut bolts for surface fixing. xii) Compliance: Conforming to IS/IEC standards.
S & F in replacement of Cable, single core 1.5 Sqmm size,FRLS type two runs(for phase and neutral) PVC insulated unsheathed multi stranded copper conductor cables drawn in PVC Conduit complete all as specified and directed.Make : Havells/Polycab/ Finolex. Note -( two runs of 1.5 Sq mm single core copper conductor shall be measured as one unit length)
S&F thermoplastic cable junction box with metric knock out for cable entry of size 200x160x98mm with 4 Nos of 200A aluminium busbar mounted on insulators, terminal and provision of din rail for fixing of MCB 10A capacity including fixing with clamp 30x5mm iron flate, nuts, bolts and washer complete including providing of steel conduit of dia 32mm bore of length 1.60 mtr including earth work for taking out of cable,old unsv junction box and fixing complete all as specified and directed.
S&F in replacement GI braket for fixing of bldg security light fitting with GI pipe 32/40 mm dia atleast 1.5 mtr long to be fixed in wall while constructing the wall and it has to be bend in 45 degree angle to install the bldg security light fitting including necessary cutting, welding and MS fastner, clamp with strip 38mm wide upto 6mm thick (Min) to the light and painting the bracket by good quality paint as directed by Engr-in-Charge.
S&F in GI pipe light grade with all fittings for passing of cable fixed to pole /wal / laid under floor or roads including all fixing accessories omplete for protection of cable of size 40 mm dia bore complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Solar Street Light (integrated all-in-one type) , testing and commissioning, with the following features all as specified and directed by Engineer-in-Charge. i) Luminaire Housing: Pressure die-cast aluminium for sturdiness, corrosion resistance, and thermal management. ii) LED Light Source: 20 Watt (minimum), cool white (≥ 5700K), symmetric light distribution, lumen efficacy ≥ 120 lm/W, CRI ≥ 70, life > 50,000 burning hours (L70). iii) Solar Panel: High-efficiency mono / poly crystalline PV module (minimum 40 Wp), integrated with the luminaire. iv) Battery: Inbuilt lithium ferro phosphate (LiFePO4) battery, minimum 12.8V, adequate capacity to provide ≥ 12 hours autonomy on a full charge. v) Charge Controller: Inbuilt MPPT / PWM controller with protections against overcharge, deep discharge, short circuit, and reverse polarity. vi) Sensor: Motion / dusk-to-dawn sensor for automatic operation. vii) Mounting Arrangement: Designed for pole mounting, complete with brackets allowing adjustment at different tilt angles. viii) Ingress Protection: Luminaire IP65 or higher. ix) Surge Protection: Built-in SPD (minimum 4 kV). x) Compliance: As per IS/IEC standards. Make: Philips Cat. Part No. BRP710 LED20 CW MR S1 12V LFPAIO Solar Equip IN with sensor, Eveready Cat. Part No. LEDSS02015-01, or equivalent in Havells.
S&F in replacement of Post Top Lantern Light, LED 35 Watt, IP65 protection, with symmetric light distribution, suitable for outdoor lighting of gardens, pathways, and open areas, complete with fixing arrangements, connections, testing and commissioning, all as specified and directed by Engineer-in-Charge, with the following minimum features: i) Luminaire Housing: High-strength pressure die-cast aluminium/polycarbonate body, corrosion resistant, UV stabilized, powder coated, designed for pole top mounting. ii) Light Source: 35 Watt high-power LEDs, Cool White (CCT ≥ 5700K). iii) Luminous Efficacy: ≥ 110 lm/W. iv) Lumen Output: ≥ 3800 lumens. v) CRI: ≥ 70. vi) LED Life: ≥ 50,000 burning hours (L70 at 25°C). vii) Optics: Symmetric light distribution with clear/diffused polycarbonate diffuser for uniform illumination. viii) Ingress Protection: IP65 or higher. ix) Impact Resistance: IK07 or higher. x) Electricals: Power factor ≥ 0.95, THD < 10%, system efficiency > 85%, operating voltage 140–270V AC, 50 Hz. xi) Surge Protection: Minimum 4 kV built-in SPD. xii) Mounting: Suitable for post top mounting on poles of 2.5 m to 4 m height with supplied bracket/clamp. xiii) Compliance: As per IS/IEC standards.
S&F in replacement of Garden Light LED, 10 Watt, IP65 protection, with symmetric light distribution, suitable for outdoor installation to uniformly illuminate walkways, pathways, and steps, complete with fixing arrangements, testing and commissioning, with the following minimum features, all as specified and directed by Engineer-in-Charge: i) Luminaire Housing: High-strength corrosion-resistant aluminium/polycarbonate body, UV stabilized, powder coated, with integrated mounting arrangement. ii) Light Source: 10 Watt high-power LEDs, Cool White (CCT ≥ 5700K). iii) Luminous Efficacy: ≥ 100 lm/W. iv) Lumen Output: ≥ 1000 lumens. v) CRI: ≥ 70. vi) LED Life: ≥ 50,000 burning hours (L70 at 25°C). vii) Optics: Symmetric distribution with clear/diffused polycarbonate cover. viii) Ingress Protection: IP65 or higher. ix) Impact Resistance: IK07 or higher. x) Electricals: Power factor ≥ 0.95, THD < 10%, operating voltage 140–270V AC, 50 Hz. xi) Surge Protection: Minimum 2.5 kV built-in SPD. xii) Mounting: Suitable for pole/ground mounting with height ≥ 0.6 m to 1.2 m for optimum illumination. xiii) Compliance: As per IS/IEC standards.
S&F in replacement of Cable Junction Box, weatherproof, suitable for security lights, garden lights and post-top lantern lights, made of high-strength polycarbonate body, protection class IP67, suitable for unprotected outdoor installation, complete with terminal block suitable for cable size up to 25 sqmm, including fixing, connections, testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
Boring holes under road / pavement manually by “Bocky” method in any type of soil, up to 50 mm dia bore, complete all as specified and directed by Engineer-in-Charge.
M/S Davinder Kumar (BID ID -3440815)
S K ENGINEERS AND CONTRACTOR (BID ID -3435323)
PARAS ENTERPRISES (BID ID -3433722)
Vijeta Solutions (BID ID -3431872)
M/S ADHIKARI CONSTRUCTION CO. (BID ID -3433269)
J V ENGINEERS / JAI SINGH (BID ID -3435363)
Deep Contractor (BID ID -3435758)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .