Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC AMBATTUR | AMBATTUR | TIRUVALLUR | TAMIL NADU | 600053 | L1 | Accepted-AOC Accepted | |
| 2 | Rejected-Technical | - | Rejected-Technical Not Accepted |
Tender Value
Refer Docs
EMD Value
₹5,800
Closing Date
3 Dec 2024, 2:00 pmClosed
SE MI NCTPS1 CH 120
O/o SE MI NCTPS1 CH 120
NCTPS I SE MI Circle AOH 24 25 BM Dn Reconditioning of defective passing of SH RH spray station control valves and CBD EBD valves with build up ends for Unit III boiler during the year 2024 25
2024_EB_504831_1
CE SE MI NCTPS I 207 24 25
Open Tender
Power/Energy Projects/Products
Works
45 days
Work
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹5,800
Yes
25 Mar 2025
28 Nov 2024
4 Dec 2024
28 Nov 2024
3 Dec 2024
28 Nov 2024
Amount
Transporting of old spray station control valves form NCTPS I site to Work shop. Charges including consumable and hire charges for T&P's.
Machining the valve stem & disc in lathe to expose parent metal to have good bonding for welding and filling up material in the worn out area of valve stem & disc by welding using alloy steel welding electrode and machining the valve stem & disc to the required size. Including consumable and hire charges for T&P's.
Lapping of valve stem, disc and valve seat until getting the 100% blue match with each other. Including consumable and hire charges for T&P's.
Reassembling the valve works involves reassembling the valve with new Tech seal bonnet, Tech seal for body, Stack, Gauge and gland packing, pressure seal ring. Including consumable and hire charges for T&P's.
Rectification/ Renewal of diaphragmin pneumatic control valves: Work involves dismantling of diaphram casing, removing the adjustable lock nuts, springs and damaged diaphragm. Rectification and renewal of damaged parts such as spring, diaphragm, casing bolt and nuts. Reassembling the same and tighting the adjustable lock nut to required pressure for smooth operation of control valves. Including consumable and hire charges for T&P's.
Hydraulic testing of the reconditioned valve at 170 kgs/cm2 max pressure in presence of site Engineer. Including consumable and hire charges for T&P's.
Transporting of reconditioned spray station control valves form workshop to NCTPS I site. Including consumable and hire charges for T&P's.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .