Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC NAU PUKHRI ROAD MILLAN PALLY BYE LANE 2 NEAR GOYAL PALACE PO DISTT TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L1 | Accepted-AOC BEING LOWEST TENDERER | |
| 2 | L2₹6.4 L+₹66,630 (11.6%)Rejected-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L2 | Rejected-Finance DUE TO HIGHER RATES | |
| 3 | L3₹6.6 L+₹88,388 (15.4%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L3 | Rejected-Finance DUE TO HIGHER RATES |
Tender Value
₹5.5 L
EMD Value
₹11,000
Closing Date
26 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE LEKHAPANI
TINSUKIA, ASSAM
REPAIRS/MAINT OF VARIOUS CAPACITY DG SETS AT LEKHAPANI MIL STN UNDER GE LEKHAPANI
2022_MES_561532_2
8706/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE LEKHAPANI
Class E and category b (i)
4 documents required · 4 mandatory
₹500
GE LEKHAPANI
₹11,000
Yes
3 Feb 2023
5 Jan 2023
30 Jan 2023
5 Jan 2023
26 Jan 2023
12 Jan 2023
Amount
M&L Quarterly Maintenance and servicing of DG Sets comprising Prime mover and alternator with accessories, control panel and connected electric circuits with various type of sensors etc including checking lubricating oil, coolent, filters,V-belt, self starter, battery power, gauges and other connected accessories and identifying malfunction of the DG Set (if any) of following capacities complete all as specified and directed. (a) DG Set of capacity 125 KVA
(b) DG Set of capacity 40 KVA
(c) DG Set of capacity 30 KVA
(d) DG Set of capacity 20 KVA
(e) DG Set of capacity 15 KVA
(f) DG Set of capacity 5 KVA Note for Item No 1 : (a) Item comprises site visit charges for authorised technician of OEM of DG Set (or) qualified/experienced technician of DG Sets for checking, identifying the functionality of DG Set and will carry out required preventive maintenance work and ensure smooth functioning of DG sets and connected works. (i) One Quarterly maintenance will be paid as "Each Job". (ii) Major spares of DG Set will be measured and paid seperately under relevent item of the CA catered as supply only. (iii) Technician will visit each DG Set quarterly for routine checkup/servicing on date fixed (or) as and when required (in case of break down of DG Set). (iv) Minor spares like nuts/bolts, washers, oil seal, gaskets, cotton waste, clamps shall deemed to be included in the job.
Supply and fixing (in replacement) spin on diesel fuel filter (pre and fine filter) element with O ring of make : Mico/Kirloskar/Ruston for generator set of following capacity :- (a) 5/15 KVA
Supply and fixing (in replacement) Dry type Air filter element Inner and Outer unit as required at site with O' Ring of Make : Mico/Kirloskar/Ruston suitable for following capacity DG Set:- (a) 20 KVA
Supply and fixing(in replacement) Lub oil filer element with O'Ring of Make : Mico/Kirloskar/Ruston suitable for following capacity DG Set:- (a) 5/15 KVA
Supply and replacement Water outlet and inlet hose pipe from radiator to Engine and back from Engine to radiator complete all as specified and directed..
Supply and replacement Lub oil pipe PVC of suitable length and socket of size 15mm dia all as specified and directed.
Supply and top up coolent oil. Make : Volvo line / Servo / Castrol
Supply and top up engine oil 15W40 grade. Make : Volvo line / Servo / Castrol
Supply and replace battery connecting copper cable with terminal made of brass with nuts/bolts/washer (as per sample) all as specified and directed.
Supply and top up Battery Distilled water.
Disconnecting, dismantling 12 V battery charging alternator assembly replacing the unserviceable burnt coil assembly, re-assembling, refixing to engine and testing for satisfactory charging of battery complete all as specified and directed.
Supply and fix (in repair) battery 12V, 120 AH, initial charging, filled with required electrolite/distilled water and fixing/connecting with electric connector cable all as specified and directed. Make : Exide Model : Gen Plus or equivalent
Material and labour for disconnecting and taking down 15 KVA, 20 Amps Main Alternator assembly from engine fly wheel, transporting to workshop, dismantling the alternator assembly rotor coil and washing it with water jet and drying it by placing inside the oven for a while and re-warnishing completely. Taking down burnt/worn out winding wire of the stator, completely cleaning and re-winding with insulated copper winding wire of suitable size and with number of turns as required to achieve the required voltage and ampere and re-warnishing with superior quality varnish, drying inside the oven for required duration to remove the moisture content completely, replacement of bearings and reassembling the stator and rotor coil, transporting back and connecting with engine fly wheel and testing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing (in repairs) AVR (Auto Voltage Regulator) suitable for Gen Set 5 KVA to 40 KVA having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, outpur current 4 A DC voltage regulation +/- 1% average volts, over excitation current tripping fuse protection 4A, fast acting and frequency 50Hz for the following capacities :-
Supply and fixing (in repair) Digital DG Controller suitable for any type DG Set of any capacity complete and connecting with existing electrical circuit all as specified and directed. Make : Kirloskar Green Model KG934V1 or equivalent
Supply and fixing (in replacement) CT Coil with CT Ratio 100/5A, 5VA Cl 1.0 accuracy all as per IS 2705-1992 and as specified and directed. Make : NEWTEK or equivalent
Supply and fixing (in replacement ) Self Stater Assembly suitable for 20 KVA to 40 KVA DG Set and connecting with electric circuit complete all as specified and directed.
S&F (in replacement) PVC insulated Single core, 1.5 sqmm, copper conductor, stranded cable suitable for inter connection of electric network inside panel including provn of suitable size copper thimbles/lugs with nuts, bolts & washers (considered 02 thimbles/lugs per RM) all as specified and directed.
S&F (in replacement) On load change over switch 100 Amps, 415V, AC 50 Hz, front operated handle, totally enclosed in sheet metal enclosure including fixing on wall with suitable accessories and connecting the cable end with suitable size lugs, nuts/bolts/washers etc complete all as specified and directed.
Dismantling, removing the self starter, motor from the engine of following capacity DG sets, opening the self starter body and overhauling/servicing, replacement of carbon brushes with holders, contact plates, jumping leads and seals, re-varnishing the field coil, armature, re-assembling, testing for smooth functioning and re-fixing with the engine and connecting complete all as specified and directed for the following DG set:- (a) 5/15/20/30 KVA Genset
(b) 40 KVA Genset
(c) 125 KVA Genset
Supply and fixing in replacement LED phase indicator lamp assy RYB
S&F DG Set diesel tank lock (as per sample) with fixing accessories complete all as specified and directed.
S&F DG Set canopy door hinges (as per sample) with fixing accessories complete all as specified and directed.
S&F DG Set canopy door lock (as per sample) with fixing accessories complete all as specified and directed.
S&F DG Set Water pump assly with fixing accessories suitable for 15 KVA DG Set complete all as specified and directed.
S&F DG Set Oil pressure sensor assly with fixing accessories suitable for DG Set of any capacity complete all as specified and directed.
S&F Stop solenoid assly with fixing accessories suitable for DG Set of any capacity complete all as specified and directed.
Disconnecting and taking down old broken wiring of DG Set Control panel and rewiring as per manufacturer circuit diagram with appropriate size solid/stranded copper conductor wire and connecting with various sensors and testing complete all as specified and directed.
Repair/overhauling of DG set 20 KVA, dismantling and removing nuts & bolts electric connections, water connections for the following repairs/overhauling :- Dismantling/opening of complete cylinder head assembly rocker arms assembly piston head assembly sleeves by removing nuts & bolts for repairs complete. Servicing Washing of complete engine parts with kerosene oil. Reassembling of complete engine by tightening of nuts and bolts with replacement of the following engine part and testing on full load for 8 hours :- Bearing set-01 Anabond-01 set Piston Ring Set-02 Sets Piston Complete- 02 Nos. Liner - 02 Nos Gasket set as required - 01 set
M/s PRABIR ENTERPRISE
M/s HALDER ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .