Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC H NO 2049 HANUMAN COLONY NEAR TCP 3 HISAR CANTT PIN 125006 HARYANA | HISAR | HARYANA | 125006 | L1 | Accepted-AOC L1 | |
| 2 | L2₹25.1 L+₹2.1 L (9.22%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L.3₹28.3 LRejected-Finance NOT FOUND | L.3 | Rejected-Finance Other than L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
7 Jun 2025, 6:00 pmClosed
GE (AF) SIRSA
GE (AF) SIRSA, HARYANA-125055
REPAIR/MAINT/IMPROVEMENT OF VARIOUS TYPES OF PUMP SETS WITH ALLIED WORKS INCLUDING MAINTENANCE OF SWIMMING POOL, DISTRIBUTION AND RISING MAINS AND REPAIR/MAINT OF EARTHING AND LIGHTNING ARRESTOR SYSTEM AND CONNECTED WORKS AT AF STN SIRSA
2025_MES_708713_1
GE/SRA/T-12/2025-26
Open Tender
Miscellaneous Works
Item Rate
330 days
GE (AF) SIRSA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) SIRSA
₹70,000
Yes
25 Jun 2025
17 May 2025
9 Jun 2025
17 May 2025
7 Jun 2025
26 May 2025
Amount
SCHEDULE 'A' PART-I (PUMP & MOTORS)
Taking down Electric/Induction motor 40 HP capacity, of any Make/Model from existing position, Shifting to workshop for the repair work, removing the burnt winding, cleaning rotor, stator, re-winding the motor with super enamelled copper wire of size equivalent to the original winding including insulated packing materials, Varnishing, Drying etc and installing back to the original position, testing and commissioning on full load for 8 hrs continuous running complete all as specified & directed by Engr-in-Charge. NOTE : Bearing & Bush will be measured and paid separately under relevant items.
-ditto- but for motor of capacity 20 HP, 3 phase, AC, 415V
-ditto- but for motor of capacity 10 HP, 3 phase, AC, 415V
-ditto- but for motor of capacity 1 to 2 HP, 1 phase, AC, 220V
S&F in repairs TC 15 rubber Coupling including dismantling of old unserviceable from shaft complete all as specified and directed.
M&L for Rewinding Submersible Motor 15 HP, 3 phase, AC, 415V with PVC insulated Copper wire of same Gauge High Class Insulating materials of the existing Size, Varnishing, Heating, etc., for the following capacities of Motor all as specified & directed. NOTE : Bearing & Bush will be measured and paid separately under relevant items.
-ditto- but for submersible motor of capacity 20 HP, 3 phase, AC, 415V
-ditto- but for submersible motor of capacity 25 HP, 3 phase, AC, 415V
Taking down Unserviceable Centrifugal/ Mono Block/ Vertical High pressure Pump Set any type & any Model 7.5/10 HP by disconnecting from Motor, Suction and Delivery Line for carrying out repairs at Workshop by replacing Defective/ unserviceable Parts including Greasing replacement of Packing Sheet, Gland, Stud, Bearing, Cover Sheet & Lath Work of Impeller Shaft, etc. including transportation and Testing & Commissioning after replacement of parts, complete all as specified and directed. NOTE : Bearing & Bush will be measured and paid separately under relevant items.
-ditto- but for pump of capacity 1 to 2 HP, 1 phase, AC, 220V
Supply only Ball Bearing (as approved) suitable for Pump Set 7.5/10 HP, complete all as specified and directed.
Supply only Ball Bearing (as approved) suitable for Pump Set 1-2 HP, complete all as specified and directed.
S&F in repairs Gun Metal Bush (as approved) suitable for Pump Set 7.5-10 HP, complete all as specified and directed.
Taking down Unserviceable Centrifugal Pump Set 20 HP by disconnecting from Motor, Suction and Delivery Line for carrying out repairs at Workshop by replacing following Defective Parts including Greasing replacement of Packing Sheet, Gland, Stud, Bearing, Cover Sheet & Lath Work of Impeller Shaft, etc. including transportation and Testing & Commissioning after replacement of parts, complete all as specified and directed. NOTE : New Spare Parts will be Measured and Paid separately.
-ditto- but for centrifugal Pump Set of capacity 40 HP, 3 phase, AC, 415V
Supply only Ball Bearing (as approved) suitable for Centrifugal Pump Set 20 HP, complete all as specified and directed.
Supply only Gun Metal Bush (as approved) suitable for Centrifugal Pump Set 20 HP, complete all as specified and directed.
Supply only Ball Bearing suitable for Centrifugal Pump Set 40 HP, complete all as specified and directed.
Supply Gun Metal Bush suitable for Centrifugal Pump Set 40 HP, complete all as specified and directed.
Supply only shaft of motor suitable for monoblock motor of 40 HP complete all as specfied and directed.
Supply only Gland Packing suitable 10mm complete all as specified and directed.
Repair/Overhauling of Submersible Pump Set 15/20 HP including replacement of Unserviceable Parts as required, complete all as specified and directed. NOTE : Bearing, Bush & Impeller will be measured and paid separately under relevant items.
-ditto- but for Submersibe Pump Set of capacity 25 HP, 3 phase, AC, 220V
Supply only SS Impeller suitable for Submersible Pump Set 20 HP, complete all as specified and directed.
Supply only Stainless Steel Bush suitable for Submersible Pump Set 20 HP, complete all as specified and directed.
Supply only Thrust Bearing suitable for Submersible Pump Set 20 HP, complete all as specified and directed.
Supply only SS Impeller suitable for Submersible Pump Set 25 HP, complete all as specified and directed.
Supply only Stainless Steel Bush suitable for Submersible Pump Set 25 HP, complete all as specified and directed.
Supply only Thrust Bearing suitable for Submersible Pump Set 25 HP, complete all as specified and directed.
Supply only shaft of motor suitable for submersible pump set motor of 25 HP complete all as specfied and directed.
Taking down Unserviceable Pump Set, 1 to 2 HP by disconnecting from Motor, Suction and Delivery Line for carrying out repairs at Workshop by replacing Defective Parts viz Bearing/bush, Impeller, Capacitor, Water Seal, Washers & Lath Work of Impeller Shaft etc. complete all as specified and directed. NOTE : Cost of new bearing, bush, Seal, Washers, Impeller, etc. shall deem to be included in the Quoted Unit Rate.
S&F in repairs Gun metal Air release valve suitable for any type Monobloc/Coupled pump set complete all as specified and directed.
M&L for Preparing Old Painted/treated Surfaces of Pump Sets and Motors of any description including cleaning of Grease/Oil Spots, etc. from the Pump Sets and Motors and applying Two Coats of Synthetic Enamel Paint and re-writing SM No. and MES No. on Pump Sets and Motors of suitable size, complete all as specified and directed.
Taking out Pumping Set for repair from Bore Well by dismantling Suction/ Delivery Column Pipe 50mm to 150mm dia and Lowering the Column Pipe after repairing the Pump including replacement of Gasket Set, worn out/ damaged Nuts and Bolts of required size carefully without causing any damage to the Pumping Set, Submersible Cable, complete all as specified and directed. NOTE : Job for taking out the Pumping Set consisting a Set of Pump & Motor shall be Paid for ONE Unit.
M&L for Rewinding Submersible Motor, non clog, vertical type up to 1.5 HP, 3 phase, AC, 415V with PVC insulated Copper wire of same Gauge High Class Insulating Materials of the existing Size, Varnishing, Heating, etc. complete all as specified & directed. NOTE :- Cost of taking out Pump Set for repair from UG Sump by dismantling Delivery Pipe and refixing after repairing of Pump to be included in the Quoted Unit Rate.
-ditto- but for Submersible Motor of capacity 3 HP, 3 phase, AC, 415V
Repair/Overhauling of Submersible Pump Set, non clog, vertical type 2 to 3 HP including replacement of Unserviceable Parts as required, complete all as specified and directed. NOTE :- Cost of taking out Pumping Set for repair from UG Sump by dismantling Delivery Pipe and refixing after repairing the Pump to be included in the Quoted Unit Rate.
Supply only SS Impeller suitable for Submersible Pump Set up to 3 HP, complete all as specified and directed.
Supply only Stainless Steel Bush suitable for Submersible Pump Set 3 HP, complete all as specified and directed.
Supply only Bearing suitable for Submersible Pump Set 3 HP, complete all as specified and directed.
Repair/Overhauling of Submersible Pump Set, non clog, vertical type 4 HP including replacement of Unserviceable Parts as required, complete all as specified and directed. NOTE :- Cost of taking out Pumping Set for repair from UG Sump by dismantling Delivery Pipe and refixing after repairing the Pump to be included in the Quoted Unit Rate.
Supply only SS Impeller suitable for Submersible Pump Set 4 HP, complete
Supply only Stainless Steel Bush suitable for Submersible Pump Set 4 HP, complete
Supply only Bearing suitable for Submersible Pump Set 4 HP, complete
SCHEDULE 'A' PART-II (PIPE LINES & VALVES)
Supply, fixing & Lowering GI Column Pipe 80 mm bore (dia), 3.00 METRE in Length, medium grade, ISI marked, both End Flanged with Rubber/ Fibre Joints with Mild Steel Bolts, Nuts, & Washers, etc. including Taking down/ out unserviceable Column Pipe, complete all as specified and directed.
-ditto- but for GI Column Pipe of size 100mm bore
S&F in repair Cast Iron non-return valve, 80 mm bore, Class PN 1.0, heavy duty, ISI marked (IS 5312), flanged end including 3 mm thick rubber gasket joints, nuts, bolts etc complete all as specified and directed.
Supply, Installation and testing of Chemical Dosing system suitable to inject solution up to 21 LPH comprising of dosing pump coupled with and including 3 phase electric motor of suitable capacity, 1440 RPM along with standard accessories such as non-return valve, foot valve etc including dismantling of old unserviceable dosing system complete all as specified and directed. NOTE:- The replaced dosing pump assembly shall be installed on the existing chlorine tank, connected to the existing lead tube of agitator shaft and properly tested for satisfactory operation of the overall plant.
S&F in repair Cast Iron Sluice valve of Class PN-1.6, 150 mm bore, long body type, heavy duty, ISI marked (IS 1538) flanged end with iron wheel and brass spindle including 3 mm thick rubber gasket joints, nuts, bolts etc complete all as specified and directed.
-ditto- but Sluice Valve of 100 mm bore
SCHEDULE 'A' PART-III (RO PLANT)
Routine Maintenance & Operation of CENTRAL REVERSE OSMOSIS TYPE WATER TREATMENT & PURIFYING PLANT having capacity of delivering Pure, Safe and Healthy Drinking Water 5000 LITRE PER HOUR by removing dissolved Solids like Calcium, Magnesium, Sodium Bicarbonate, Chlorides, Sulphides, etc. in Water by 90-95% and reducing Harmful Minerals like Arsenic, Fluorides, Lead, Bacteria, etc. and to bring Water Hardness Level to Safe Drinking Water Limits, Skid Mounted type including Routine Checking of Metering Equipments like Voltmeter, Ammeter, Flow Meter, Conductivity Meter (TDS Meter) PH Meter, Pressure Meter, etc. alongwith Routine Maintenance of RO Water Supply Pumping Set 3.0 HP capacity Each, complete all as specified and directed. NOTES :- (a) The Contractor shall engage One Experienced Technician who will visit at an interval of EVERY 03 MONTHS and/or as and when required/directed by the Engineer-in-Charge to examine and repair the Plant. The Technician will report to the JE E/M and Engineer-in-Charge for his Every Visit, failing which no Payment will be allowed to the Contractor. (b) The Plant shall not remain Non Operation more than 8 HOURS in any case either due to Break down or Maintenance otherwise a recovery @ Rs. 300.00 PER HOUR shall be charged from the Contractor beyond 8 HOURS for Non Operation of Plant. (c) The Quoted Unit Rate includes fixing only for non workable major parts as and when required basis. (d) The Quoted Unit Rate includes the Cost of Chemicals as recommended by Manufacturer for Flushing/Cleaning the System. (e) The Quoted Unit Rate is inclusive of Periodical Back Wash or as and when required to maintain as per the Treatment Guideline of Plant including Cleaning. (f) The Cost include the replacement of Minor Spares like Washers Nylon/ Lead, Teflon Tape, Bolt & Nuts, Gland Packing, Gasket, etc. other than specifically Priced. (g) Major Spares like Micron Filter, Membrane etc. will be Measured and Paid for separately. (h) The quoted rate shall also be deemed to include for the monthly visits of technician to replace the micron filters. However, measurement shall only be considered for the quarterly visit for maintenance of the whole plant.
Supply only Anti-Scalent Chemical (Consumable), in sealed containers, suitable for preventing Scaling of Membrane of Plant complete all and directed by Engineer in Charge.
Supply only Micron Filter of size 4 Inch dia x 20 Inch Length with Filter capacity up to 1 micron (as approved) complete all as specified and directed.
Supply only Membrane Module of size 8040 suitable for 5000 Litre Central RO Plant (as approved as existing) and Fixing-in-repairs, complete all as specified and directed. (MAKE : TORRAY/ ION EXCHANGE/ DOW)
S&F in repairs Multi port valve of size 32/40 mm bore suitable for RO plant incl testing on completion complete complete all as specified and directed.
SCHEDULE 'A' PART-IV (SWIMMING POOL)
Supply, fixing & testing Multi port valve of size 100 mm bore suitable for swimming pool incl taking down old one complete all as specified and directed.
M&L for Cleaning Swimming Pool by Cleaning Entire Internal Surface by removing Dirt, Sludge, etc. with Wire Brush by applying Bleaching Powder and Fresh Water and Cleaning Entire Surface repeatedly with Fresh Water and Draining Out Soiled Water including using Pressure Jet Pump and Suction Pump capacity of Pool Surface using Acid and other suitable Methods before filling as required at Site, complete all as specified and directed. NOTE :- (a) Quoted Unit Rate shall include for filling the Swimming Pool with Water and de-watering as per requirement the Water Supply provided by Department. (b) The Quoted Unit Rate is inclusive of Chemicals required to Clean the Swimming Pool and Pump Sets, etc.
M&L for Cleaning Level Tank & connected drain/trenches for Swimming Pool using Acid and other suitable methods before filling as required at Site, complete all as specified and directed. NOTE : Quoted Unit Rate shall include for filling the Level Tank for Pool with water and de-watering as per the Water Supply provided by Department.
M&L for Draining out Water by removing the Drain Plug from Swimming Pool Media Filter Tank, Take Off Multiport Collar (Clamp) unscrewing union from the Multiport Valve including carefully Opening, Covering to Stand Pipe with Duct Tape or Rubber Plug, Taking out Muddy and Dirty Sand by using Vacuum Equipment to suck out the Sand or using Plastic Tumbler Cup to scoop out the Sand, Taking out Water, Pouring Pipe Stand Pipe without damage and removing the Internal Grid Assembly carefully, replace to worn out Stand Pipe, Internal Grid Assembly or Multiport Valve, Cleaning to Filter with Dilute Acid or Soap or Anti Scalent Chemical for removing Sludge and Clean to Sand Filter, Pouring Water Half Tank and filing to Standard Silica Sand and Pea Gravel suitable for Swimming Pool Media Filter and replacing Worn Out 'O' Ring with Serviceable 'O' Ring with tightening Lubricant Reassembling to Main Holes, Servicing of Inlet, Outlet, Backwash and Air Release Diaphragm Valve along with water connection pipe, testing of Leak Proof, complete all as specified and directed. (NOTE: Sand, Pea Gravel, Anti-Scalent Chemical and accessories measured under Item No 4.07 shall be measured seperately as "Supply Only". Quoted rate shall be deemed to include for all other spares and consumables. No claim shall be entertained during currency of work.
Supply only Silica Sand 0.4-0.8mm for Swimming Pool Media Filter complete and all directed by Engineer in Charge.
Supply only Pea Gravel 3.5-5.6mm for Swimming Pool Media Filter complete and all directed by Engineer in Charge.
Supply only Accessories Filter, Valve of Media Filter including Taking out Old US Accessories Filter, Valve, complete and all directed by Engineer in Charge.
M&L for preparing Old Painted/treated Surfaces of Main Panel including cleaning, removing loose paint flakes, rust etc, applying red oxide primer over rust patches and finishing with Two Coats of Synthetic Enamel Paint and re-writing Pump No. & ON OFF suitable size, complete and all directed by Engineer in Charge.
S&F in repair Pressure Gauge/Vacuum Gauge with Nipple 0-14 Kg rating complete and all directed by Engineer in Charge.
S&F in repairs Suction Sweeper PVC flexible Suction pipe 50mm complete and all directed by Engineer in Charge.
S&F in repairs Suction Sweeper Brush (as approved), complete and all directed by Engineer in Charge.
S&F in repairs Suction Sweeper castor wheels (as approved), complete and all directed by Engineer in Charge.
M&L Taking down Defective Electric Motor 3.5 HP of existing make-Pentair, Dismantling the burnt out Winding Wire and Rewinding the Motor with Super Enamelled Copper Winding Wire using High Class Insulating Materials of the existing Size, Varnishing, Heating, etc., Re-assembling complete Motor and necessary Transportation, complete and all directed by Engineer in Charge.
M&L for Repairing of Pump 3.5 HP of existing make-Pentair, including providing Seal/Gasket, Washers, Impeller, etc. as required at Site, complete all as specified and directed. NOTE:- Cost of new bearing, bush, Seal, Washers, Impeller, etc. shall deem to be include in the Quoted Unit Rate.
Supply only Alum Grade 1 (as approved), in sealed bags complete all as specified and directed.
Supply only Copper Sulphate (as approved), in sealed bags complete all as specified and directed.
Supply only Soda Ash (as approved), in sealed bags complete all as specified and directed.
Supply only Tricloro Cynuric Acid (TCCA-90) (as approved), in sealed containers complete all as specified and directed.
Supply only Muriatic acid liquid (as approved), 31.45% concentration, in sealed container complete all as specified and directed.
SCEDULE 'A' PART-V (STARTER & PANELS)
S&F in repairs MCCB 63 Amp, Ics=Icu, with adjustable thermal setting, 3 Pole, 415 Volt, 50 Hz, 16 kA with necessary Connections with Thimbles, etc. complete all as specified and directed.
S&F in repairs MCCB 100 Amp, Ics=Icu, with adjustable thermal setting, 3 Pole, 415 Volt, 50 Hz, 25 kA with necessary Connections with Thimbles, etc. complete all as specified and directed.
-ditto- but MCCB of rating 125 Amps
-ditto- but MCCB of rating 160 Amps
-ditto- but MCCB of rating 200 Amps
S&F in repairs of Analogue type Volt-Ammeter Class 1, 3Ph, 500 Volt, 0-125 Amp complete all directed.
Supply & laying Flat Copper Cable insulated, PVC Sheathed Water Proof, conforming to IS-694, 1100 Volt Grade suitable for Submersible Pump Set, Cross-sectional area 6.0 Sqmm, 3 Core including taking down/out unserviceable Cable, complete all as specified and directed.
Supply & laying Flat Copper Cable insulated, PVC Sheathed Water Proof, conforming to IS-694, 1100 Volt Grade suitable for Submersible Pump Set, Cross-sectional area 10 Sqmm, 3 Core including taking down/out unserviceable Cable, complete all as specified and directed.
Taking down/up unserviceable LT cable of size 25 Sqmm to 50 Sqmm, 3.5/4 core incl necessaery disconnection for repair/ replacement etc (from cable duct/underground trench / pole), stacking properly (cable, pipe and bricks) complete all as specified and directed. (Note :- Earth work to be measured and paid separately).
Supply, Laying and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, of size 16 sqmm 4 core, laid in trench or fixed to wall/passing through pipe/pole incl necessary aluminium thimbles, jointing and testing complete all as specified and directed. (Note :- Necessary earth work to be measured and paid separately)
-ditto- but for cable of size 25 Sqmm, 3.5 core
Excavation in trenches not exc 1.5 metre width and not exceeding 1.5 metre in depth in soft/loose soil and getting complete all as specified and as directed.
Excavation of trench for portions of road/hardstanding etc, not exc 1.50 m wide and not exc 1.50 m deep and getting out complete all as specified and directed.
Returning, filling in including spreading levelling watering and well ramming in layers n.exc 25 thick for soft/loose soil complete all as specified and as directed.
Removal of excavated material to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
M&L for sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. (Note: Punned thickness of sand shall be measured)
Supply & laying in Trenches Sub-class ‘B’ Bricks, kiln burnt, laid perpendicular to the cable for Cable Protection, complete all as specified and as directed.
Relaying of serviceable bricks for protection of LT UG cables, laid perpendicular to the axis of cable complete all as specified and directed.
Supply Installation & testing of 3 Phase DOL Starter with wide band coil , Relay Range 9 to 14 Amp, 415 Volt, 50 Hz, suitable for 6 HP pump comprising with Voltmeter, Ammeter, single phase preventor, etc including Taking down old u/s starter, complete all as specified and directed. (MAKE : L&T Cat No. SS95983COAO or equivalent model in other makes listed in tender)
Supply Installation & testing of 3 Phase FASD Starter with wide band coil, Relay Range 20 to 33 Amp, 415 Volt, 50 Hz, suitable for 20 HP submersible pump comprising with Voltmeter, Ammeter, single phase preventor etc including Taking down old u/s starter, complete all as specified and directed. (MAKE : L&T, Cat No. CS96008COEO or equivalent model in other makes listed in tender)
Supply Installation & testing of 3 Phase FASD Starter with wide band coil, Relay Range 30 to 50 Amp, 415 Volt, 50 Hz, suitable for 30 HP submersible pump comprising with Voltmeter, Ammeter, single phase preventor etc including Taking down old u/s starter, complete all as specified and directed. (MAKE : L&T, Cat No. CS90908LOGO or equivalent model in other makes listed in tender)
S&F in repairs Fully Automatic Star Delta Starter for Submersible Pump with single phase preventer, for 30 HP motor, in sheet steel enclosure (motor rating AC-3 Duty, 415 V, 50 Hz, 3 Phase) with relay range 30-50 Amps complete including mouting on 50x6mm flat iron clamp duly grouted on wall with a minimum clearance of 2" from wall incl necessary incoming & outgoing electrical connections, copper lugs, etc. complete all as specified and directed (NOTE: Cost of MS clamps, nuts & bolts, lugs etc shall deemed to be inclusive in the quoted rate.)
S&F in repairs Power Contactor, AC3 rating 25 Amps, Type MNX25, 3 phase, 3 pole, 415V, conforming to IS/IEC 60947-4-1 complete all as specified and directed. (MAKE: L&T, Cat No: CS94110 or equivalent model in other makes listed in tender)
-ditto- but for 40 Amps, Type MNX 40 (MAKE: L&T, Cat No: CS94190 or equivalent model in other makes listed in tender)
-ditto- but for for 50 Amps, Type MNX 50 (MAKE: L&T, Cat No: CS97075 or equivalent model in other makes listed in tender)
-ditto- but for for 70 Amps, Type MNX 70 (MAKE: L&T, Cat No: CS97076 or equivalent model in other makes listed in tender)
-ditto- but for 18 Amps, Type MNX 18 (MAKE: L&T, Cat No: CS94100 or equivalent model in other makes listed in tender)
-ditto- but for 09 Amps, Type MNX 9 (MAKE: L&T, Cat No: CS94106 or equivalent model in other makes listed in tender)
S&F in repairs Overload Relay, type MN2, 9 -15A relay range, suitable for Star Delta motor starters, directly mounting including all accessories complete all as specified and directed. (MAKE: L&T, Cat No: SS94142OOBO or equivalent model in other makes listed in tender)
-ditto- but for 14 - 23A relay range. (MAKE: L&T, Cat No: SS94144OODO or equivalent model in other makes listed in tender)
-ditto- but for 24 - 40A relay range. (MAKE: L&T, Cat No: SS94145OOFO or equivalent model in other makes listed in tender)
-ditto- but for 30 - 50A relay range (Type MN5) (MAKE: L&T, Cat No: SS94136OOGO or equivalent model in other makes listed in tender)
-ditto- but for 45 -75A relay range (Type MN5) (MAKE: L&T, Cat No: SS94137OOJO or equivalent model in other makes listed in tender)
Attending complaints in respect of electric supply connections, faults, breakdown etc in various Pump houses anywhere inside Air Force Area and Zhopra Complex, deploying suitable electrician for fault finding, repairing and rectifying the defects including supply of consumables, petty spares & accessories, multistranded copper wires upto 6 sqmm (not exceeding 1.0m length), thimbles etc complete all as specified and directed. (NOTE: Major parts/accessories, if required to be replaced shal be measured and paid seperately under respective item.)
Supply and fixing of of PCC Route Marker over pipelines in technical and domestic areas of AF Stn, of size 1mX0.50mX0.50m, duly painted with blue colour synthetic enamel paint and marked with "MES WATER PIPELINE" in white colour capital letters of suitable size including necessary earthwork for fixing the markers complete all as specified and directed.
S&F in repairs including installation, commissioning and testing Polycarbonate LT feeder Pillar, Indoor Type, made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES of suitable size, having IP65 grade ingres protection, duly provided with with TPN Bus Bars fixed on insulators on PVC / epoxy insulators, mounted on and including angle iron frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC foundaton complete with suitable cable Glands/Grommets and including all provision of opening for incoming/outgoing cables and testing complete all as directed including comprising the following accessories :- A) (i) TPN Aluminium Bus Bar of capacity 600 Amps for phases & 250 Amps for neutral and auxiliary bus bar to support main bus bar. duly supported on SMC/DMC, bus bar supports and insulated with colour coded heat shrinkable sleeve. (ii) Digital multifunction meter (V, A, KW, KWH), 415V AC along with C.T’s of suitable ratio (set of three), class 1.0, complete. (iii) Indication lamps LED type (RYB) = 01 Set of three. (iv) CTs 500/5A class 1.0,15VA (Cast Resin) for metering - 03 nos (v) Internal wiring, with suitable size of FRLS copper conductor cable. B) INCOMER:- (i) MCCB 400 Amps, 4 pole, 36 KA, Ics=100% Icu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short ckt 5 to 10ln setting complete with phase separator - 01 No
C) OUTGOING:- (i) MCCB 125 Amps 4 pole, 25 KA, Ics=100% Icu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100%and adjustable short ckt 5 to 10ln setting complete with phase separator - 03 Nos (ii) MCCB 100 Amps 4 pole,10 KA, Ics=75-80% of 100% Icu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100%and adjustable short ckt 5 to 10ln setting complete with phase separator - 02 Nos (iii) MCB SPN, 10 Amps,10 KA, 230 Volts, 'C' Curve - 01 No (iv) Fully Automatic Star Delta Starter, duly mounted inside panel board & flushed to facilitate operations with push button suitable for 3-PHASE pump set upto 30 HP with over load relay and single phase protection feature 30-50 Amps - 02 Nos D) FOUNDATION/PLATFORM:- (i) Platform for the Panel shall be provided with PCC 1:4:8 type D-2 (40 mm graded crushed stone aggregates), 15mm thick in foundation, brickwork in cement mortar 1:6 with sub class 'B, old size' bricks, rendering 15mm thick 1:6 on exposed surfaces and 100 mm thick PCC 1:2:4 type B1 padding on top, finished even and smmoth without using extra cement and grouting of bolts etc for panel. Platform shall be of 45 cm height from nearest floor level. NOTES: (i) Contractor shall submit the relevant test reports in respect of IP Test Report and verification of short circuit withstand test report issued by CPRI in respect of the Panel/Panel manufacturer. (ii) Contractor shall submit drawing for approval of GE prior to placing order. (iii) Quoted rate shall deem to include all petty accessories and any missing/left out items which may be required for proper fuctioning of the Panel. No claim shall be entertained during currency of work. (iv) Cost of foundation shall deemed to be inclusive in the quoted rate.
S&F in repairs including installation, commissioning and testing Polycarbonate LT feeder Pillar, Outdoor Type, made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES of suitable size, having IP65 grade ingres protection, duly provided with with TPN Bus Bars fixed on insulators on PVC / epoxy insulators, mounted on and including angle iron frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC foundaton complete with suitable cable Glands/Grommets and including all provision of opening for incoming/outgoing cables and testing complete all as directed including comprising the following accessories :- A) (i) TPN Aluminium Bus Bar of capacity 400 Amps for phases & 250 Amps for neutral and auxiliary bus bar to support main bus bar. duly supported on SMC/DMC, bus bar supports and insulated with colour coded heat shrinkable sleeve. (ii) Digital multifunction meter (V, A, KW, KWH), 415V AC along with C.T’s of suitable ratio (set of three), class 1.0, complete. (iii) Indication lamps LED type (RYB) = 01 Set of three. (iv) CTs 500/5A class 1.0,15VA (Cast Resin) for metering - 03 nos (v) Internal wiring, with suitable size of FRLS copper conductor cable. B) INCOMER:- (i) MCCB 250 Amps, 4 pole, 36 KA, Ics=100% Icu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short ckt 5 to 10ln setting complete with phase separator - 01 No
C) OUTGOING:- (i) MCCB 125 Amps 4 pole, 25 KA, Ics=100% Icu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100%and adjustable short ckt 5 to 10ln setting complete with phase separator - 01 Nos (ii) MCCB 100 Amps 4 pole,10 KA, Ics=75-80% of 100% Icu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100%and adjustable short ckt 5 to 10ln setting complete with phase separator - 01 Nos (iii) MCB SPN, 40 Amps,10 KA, 230 Volts, 'C' Curve - 01 No (iv) Fully Automatic Star Delta Starter, duly mounted inside panel board & flushed to facilitate operations with push button suitable for 3-PHASE pump set upto 30 HP with over load relay and single phase protection feature 30-50 Amps - 02 Nos D) FOUNDATION/PLATFORM:- (i) Platform for the Panel shall be provided with PCC 1:4:8 type D-2 (40 mm graded crushed stone aggregates), 15mm thick in foundation, brickwork in cement mortar 1:6 with sub class 'B, old size' bricks, rendering 15mm thick 1:6 on exposed surfaces and 100 mm thick PCC 1:2:4 type B1 padding on top, finished even and smmoth without using extra cement and grouting of bolts etc for panel. Platform shall be of 45 cm height from nearest floor level. NOTES: (i) Contractor shall submit the relevant test reports in respect of IP Test Report and verification of short circuit withstand test report issued by CPRI in respect of the Panel/Panel manufacturer. (ii) Contractor shall submit drawing for approval of GE prior to placing order. (iii) Quoted rate shall deem to include all petty accessories and any missing/left out items which may be required for proper fuctioning of the Panel. No claim shall be entertained during currency of work. (iv) Cost of foundation shall deemed to be inclusive in the quoted rate.
SCHEDULE 'A' PART- VI (REPAIR/MAINT TO EARTHING AND LIGHTNING ARRESTOR SYSTEM)
M&L Checking of Earth Resistance of Chemical/Normal Earthing and maintaining the Register as per Appendix 'A' and as specified and directed here-in-after :- NOTES :- (a) Contractor will Check Earth Resistance Every Day (minimum 25 Nos. per Day) and joint measurement of earth resistance of chemical /plate electrode earthing with user, will be sole responsibility of contractor. Earthing register will maintain and signed by user also and same will be put up to the Engineer-in-Charge through JE E/M on the Very Next Day, failing which a Sum of Rs. 20.00 per Day will be recovered from the Contractor. (b) New Earth Resistance Tester will be provided by the Contractor. (Tester should be caliberated from NABL accredited labs). (c) Contractor will be responsible for pouring of water in the Earth Pits Weekly at his own arrangement with Water Tanker, etc. However, Water will be provided by the Department. (d) Checking of Earth Pits existing and improve it by watering, adding of chemical etc. (Chemical will be measured and paid separately) (e) Contractor will be responsible for marking of Earth Check date and due date on existing Plate with paint as specified by Engineer-in-Charge. (f) Contractor will be responsible for cleaning of bushes, grass, sand etc inside and all around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip. (g) Repair Party will be report every Morning and Evening to JE E/M.
Item No 6.01 (Contd...) (h) Cost of register for noting earthing results, location wise shall deemed to be included with the unit rate. Proforma of detail column will be printed as per the direction of Engineer-in-charge. (j) Recovery for Penalty will be made as follows :- (i) Earthing left without Checked lesser by 25 No. - Rs. 50.00/Earthing (ii) Earthing left without Checked in a Month - Rs. 100.00/Earthing (iii) Earthing left without Cleaning in a Month - Rs. 50.00/Earthing (iv) Earthing left without Watering in a Month - Rs. 30.00/Earthing (k) Contractor will be responsible for maintaining permissible earth resistance in Ohms in Earthing Register, failing which he will be liable to pay penalty as per IAFW-2249 and work shall be re-done by contractor in their quoted rate.
M&L for dismantling/taking out old unserviceable Chemical/Conventional earthing pit with all accessories after disconnection of earth strips including earth work as required complete all as specified and as directed.
Supply, installation, testing of CPRI tested maintenance free earthing system a set of Copper Bonded Earth Rod of 3 meter length, 17.2 mm dia made of high tensile low carbon steel circular rods, molecularly bonded with 99.9% electrolytic grade copper on outer surface (minimum copper bonding thickness-250 microns) with exothermically jointed copper bus bar of 200x50x6mm for long lasting and connection, copper bonded rod & exothermically jointed bus bar duly CPRI tested on 25 KA fault current and earth pit filled with duly by electrodite/conductolite back fill comound (Ground enhancer) complete for achieving earth resistance not more than 01 Ohm including boring in loose/soft soil 200mm dia, by means of hand/ machine drill, upto 3 Meter depth from ground level and pouring of sufficient water for at least 3 times per day (within working hours) for two days and making hole ready for pouring of Earth Enhancement Compound complete all as specified and directed. (NOTE: Pit Cover and ground enhancing compound shall be measured and paid seperately)
Supply and pouring of RoHS tested Earth Enhancement Compound after mixing with water tested by NABL accredited lab in compliance to IEC 62561-7 with a resistivity < 0.12 ohm-m. It shall be free from bentonite and other hazardous substances. It shall be a permanent, non-corrosive material and will not leach any chemicals into the ground. It shall retain moisture even in high soil resistivity areas. complete all as specified and as directed. Note: Measurement of Chemical will be done in Powder form. Contractor shall procure the item in sealed packets directly from manufacturer)
S&F in repair Earth Pit 125mm dia with FRP Earth Pit Cover of top size 200x200mm bottom size 300x300mm with height of 150mm with lockable Lid, Earth Pit cover shall be made of Poly plastic tested at 7.5 ton load for closing of earth pits complete all as specified and as directed.
M&L for replacement of PCC Pit in Cement Concrete 1:3:6 type C-1 (20mm graded crushed stone aggregate) with Cast iron cover 10mm thick hinged, Cast Iron Frame, MS Rod 6mm, Funnel as shown in Electrical Plate No 3 of MES Schedule Part-I including demolition of existing damaged pit and excavation work required at site, complete all as specified and as directed. Note : Rate shall be included for dismantling and removal debris of existing PCC pit.
M&L for replacement of Pre-cast RCC Cover with Handle 01 Nos and hole of dia 40mm in Cement Concrete 1:2:4 (20mm graded stone aggregate) of size 540x540x60mm, reinforced with and including 10mm dia TMT Bars @ 250mm Centre to Centre in both ways, complete all as specified and directed. Note : Rate shall be included for dismantling and removal debris of existing RCC cover pit.
M&L Checking of any breaking in the Link of Earth Strip/Wire of Galvanised/ Copper/Aluminium any size and jointing them by Exothermic Welding or Brazing, complete all as specified and as directed.
S&F in repair Test Point Terminal Block made of Gun Metal or Phosphorus Bronze size 75x75x25mm, drilled and screwed including 3 No. 8mm dia, 25mm long hexagonal Head Screw, complete all as per specified and as directed.
Taking out loose/displaced Serviceable Aluminium Strip/ Copper Strip/ GI Strip of any size and any description with Accessories and refixing the same with necessary Fixing Arrangement like Screws, Saddles, insulators, Nuts and Bolts, complete all as specified and as directed. Note : Cost of Screws, Saddles, insulators, Nuts and Bolts etc. shall be deemed to be included in Quoted Rate.
S&F in repair copper strip 20mm X 3 mm with saddles and fixing screws etc, for roof conductors and down conductors above ground including provn of porcelain insulator @ 1.0 m spacing complete all as specified and directed. Note: Cost of Screws, Saddles, Insulators, Nuts and Bolts, etc. shall be deemed to be included in Quoted Rate.
-ditto- but with copper strip 25 mm X 4 mm complete
-ditto- but with copper strip 32 mm X 6 mm complete
S&F in repair Aluminium Strip 25x3mm with Saddles and fixing Screws for Roof/ Earth Conductors and Down Conductors above Ground, complete all as specified and as directed. Note: Cost of Screws, Saddles, Insulators, Nuts and Bolts, etc. shall be deemed to be included in Quoted Rate.
-ditto- but with aluminium strip 25x4mm complete
S&F in repair Galvanised Iron Strip 32x6mm with Saddles and fixing Screws for Roof/Earth Conductors and Down Conductors, complete all as specified and as directed. Note: Cost of Screws, Saddles, Insulators, Nuts and Bolts, etc. shall be deemed to be included in Quoted Rate.
-ditto- but with Galvanised Iron Strip 25x4mm complete.
-ditto- but with 4mm dia galvanised iron or steel wire complete
M&L for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.00 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to copper strip 20 X 3 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
ditto but with GI earth electrode of size 600mm X 600mm X 6 mm thick and GI earth wire 4 mm dia mm complete and 15 mm dia GI protection pipe (light grade)
ditto but with GI earth electrode of size 600mm X 600mm X 6 mm thick and GI earth strip of size 25 x 4 mm complete
ditto but with GI earth electrode of size 600mm X 600mm X 6 mm thick and GI earth strip of size 32 x 6 mm complete
S&F in repair Air Termination Single Pointed Aluminium Rod 12mm dia and 300mm long with suitable Arrester Clamp made out of Brass/Gun Metal including provision of Cement Concrete 1:2:4 (20mm graded stone aggregate) Block 300x300x300mm, complete all as specified and as directed.
S&F in repair Air Termination Single Pointed Copper Rod 12mm dia and 300mm long with suitable Arrester Clamp made out of Brass/Gun Metal including provision of Cement Concrete 1:2:4 (20mm graded stone aggregate) Block 300x300x300mm, complete all as specified and directed.
S&F in repair Galvanised Iron Tubing/Pipe 15mm bore (dia), light grade for wire Protection, fixed in Walls/Floors with suitable type of Clamps, etc., complete all as specified and as directed.
S&F in repair Galvanised Iron Tubing/Pipe 25mm bore (dia), light grade for wire Protection, fixed in Walls/Floors with suitable type of Clamps, etc., complete all as specified and as directed.
S&F in repair Galvanised Iron Tubing/Pipe 40mm bore (dia), light grade for Strip Protection, fixed in Walls/Floors with suitable type of Clamps, etc., complete all as specified and as directed.
S&F in repair Galvanised Iron Tubing/Pipe 50mm bore (dia), light grade for Strip Protection, fixed in Walls/Floors with suitable type of Clamps, etc., complete all as specified and as directed.
M&L Mild Steel Work for earth marker including necessary cutting, fabrication, drilling, bolting or riveting and locking arrangement, etc. and similar work, conforming to Fe-290 Gde E-165 including dismantling unserviceable Mild Steel Work, complete all as specified and as directed. Note:- Rate included for painting of mild steel work and marking of Earth Plate Number/ Description of Earthing/Type of Earthing on Plate with White Paint including Earth Plate No. and Earthing Resistance with Earthing Check Date and Earthing Check Due Date.
NISHTHA BUILDERS (BID ID -3307379)
shiv shanker enterprises (BID ID -3310122)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .