Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹8.4 L+₹71,299 (9.26%)Rejected-Finance | L2 | Rejected-Finance Being not Lowest | |
| 3 | L3₹8.7 L+₹96,395 (12.5%)Rejected-Finance VILLAGE MATPUR POST OFFICE MANAURI ALLAHABAD 212208 | PRAYAGRAJ | UTTAR PRADESH | 212208 | L3 | Rejected-Finance Being not Lowest | |
| 4 | L4₹8.8 L+₹1.1 L (14.2%)Rejected-Finance 02 JAMEEWAR COMPLEX RING ROAD HANUMAN NAGAR GONDIA MAHARASHTRA 441614 | GONDIA | MAHARASHTRA | 441614 | L4 | Rejected-Finance Being not Lowest | |
| 5 | L5₹9.8 L+₹2.1 L (27.5%)Rejected-Finance | L5 | Rejected-Finance Being not Lowest |
Tender Value
₹9.8 L
EMD Value
₹19,600
Closing Date
25 Aug 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Manauri Prayagraj-212212
Manauri, Prayagraj-202212
REPAIR TO ROOF TREATMENT, GI SHEET AND AC SHEET IN OFFICER ENCLAVE AREA AND NEW PROJECT AREA AT AF STN MANAURI
2022_MES_541980_1
9027/E8
Open Tender
Civil Works
Item Rate
182 days
Manauri, Prayagraj
As per NIT Tender
7 documents required · 7 mandatory
₹500
AGE (I) AF Manauri
₹19,600
Yes
19 Sept 2022
29 Jul 2022
26 Aug 2022
29 Jul 2022
25 Aug 2022
13 Aug 2022
Amount
Dismantling of existing roof treatment work with brick bats/tiles set in cement/lime mortar including bedding layer/mud phuska, PCC padding (any thickness), benching etc and removing retriving material to a dsitance not exc 500m and disposed off rubbish out of MD land complete all as specified and directed. Note :- Rate shall also be deemed to include demolition of PCC or brick tiles any thickness in quoted rates.
M & L for provn of roof treatment with APP polymeric water proofing membrane all as per given below specifications:- (a) Cleaning roof surface by washing and rubbing etc. (b) M&L for plastering 10mm thick in CM 1:3 using 100% coarse sand on roof surface including liquid water proofing compound as per manufactures instructions and as directed by Engr-in-Charge. (c) Applying a coat of bituminous primer conforming to IS:3384-1986 @ 0.3 Kg/Sqm and allow to dry. (d) Applying 3mm thick APP modified polymeric membrane having wt 3.2 to 3.5 Kg/Sqm on prepared surface as per manufacturer instructions and over laps 10cm and 15cm longitudinal and trasverse directions respectively and sealed by flame torch, sealing all overlaps complete including treatment at all junctions and corners. The membrane shall be torched into groove on vertical plane and grove sealed with cement mortar 1:3. (e) Applying bituminous based aluminium paint over membrane @ 0.2 Kg/Sqm in two coats all as per specification and directed by Engr-in-Charge. Note:- (i) Water proofing treatment shall be carried out through authorized applicators. (ii) The work shall be strictly as per manufacturer’s instructions. (iii) Rate shall be deem to be include cost of liquid water proofing compound under this item. (iv) Rate shall be deem to include cost of taking down and refixing of existing PVC tank, GI tubing & fittings/fixtures etc.
M & L for provn of roof treatment with APP polymeric proofing membrane with roof tiles all as given below specifications :- (a) Cleaning roof surface by washing and rubbing etc. (b) M & L for plastering 10mm thick in CM 1:3 using 100% coarse sand on roof surface including liquid water proofing compound as per manufactures instructions and as directed by Engr-in-Charge. (c) Applying a coat of bituminous based primer conforming to IS:3384-1986 @ 0.30 Kg/Sqm and allow to dry. (d) Applying 3mm thick APP modified polymeric membrane having wt 3.2 to 3.5 Kg/Sqm on prepared surface as per manufacturer instructions and over laps 10cm and 15cm longitudinal and trasverse directions respectively and sealed by flame torch, sealing all overlaps complete including treatment at all junctions and corners. The membrane shall be torched into groove on vertical plane and grove sealed with cement mortar 1:3. (e) Applying a tack coat of hot blown bitumen grade 85/25 @ 1.20 Kg/Sqm. (f) Blinded with coarse sand dry @ 0.50 to 1 Kg/Sqm (g) Screed bed 20mm thick in CM 1:4 as in beddding layers using 100% coarse sand. (h) M & L for Cement concrete tiles 25cm x 25cm x 22mm thick roof tiles, set, jointed and pointed in neat cement slurry as in terraces over screed bed all as specified and directed by Engr-in-Charge. Note:- (i) Water proofing treatment shall be carried out through authorized applicators. (ii) The work shall be strictly as per manufacturer’s instructions. (iii) Rate shall be deem to be include cost of liquid water proofing compound under this item. (iv) Rate shall be deem to include cost of taking down and refixing of existing PVC tank, GI tubing & fittings/fixtures etc.
M&L PCC 1:2:4 type B-0 using 12.5mm graded stone aggregates as in roof padding( approx avg 30 mm thick)etc all as specified and directed .
S&F grid false ceiling in GI system powder coated prelude main runner section 38x24x0.40mm, cross 'T' 28x24x0.40mm, wall angle 24x24x0.40mm and including providing and fixing 4mm thick non asbestos fibre fire resistant cement building board/E-Board with all finishes size 595 x 595mm fixed in ceiling frame work with all necessary hanging washers, expansion holding fasteners etc for securing framework to ceiling wherever required complete including taking down existing ceiling work all as specified and directed
S&F 12mm thick gypsum plaster board flame proof conforming to IS-2095 1982 to fix as suspended ceiling with one step and including GI frame consisting perimeter channel 20X27X30X0.5 mm intermediate channel 45 (WEB) X 1.5 (flange) X 0.90mm @ 1.22 M C/C with ceiling angle 25 X10X0.5 mm fixed to soffit with GI cleat and steel expansion fastner, ceiling section 51.5 (Knurled Web X 26 (flange) with lips of 10.5 mm X0.5mm @ 610mm C/C nec clip, screw, nylon sleeves etc complete and apply two coats of oil bound distemper over a coat of putty on ceiling over preparation surface complete including taking down existing ceiling work all as specified and directed by the Engineer-in-Charge.
S&F 12mm thick gypsum plaster board flame proof conforming to IS-2095 1982 to fix as suspended ceiling on existing grid work and apply two coats of oil bound distemper over a coat of putty on ceiling over preparation surface complete including taking down existing ceiling board all as specified and directed by the Engineer-in-Charge. Note:- Gypsum Board shall be fixed on existing grid work on ceiling.
S & F in replacement 75mm dia PVC (SWR) pipes, single socketed in any length with MS clamps rings and fixed to wall/floors complete all as specified and directed
S/F in replacement 110 mm PVC (SWR) Pipes single socketed in any length with with MS clamps rings joints fixed to wall/floors complete all as specified and directed
Dismantling asbestos cement (corrugated, semicorrugated, etc.) or PGI/CGI sheets in roof coverings including ridges etc complete as specified & directed by Engineer-in-Charge.
S&F AC Serrated ridge two pieces adjustable 6mm thick for corrugated or semi corrugated AC sheets fixed with L/J type hook or cranked hook bolt all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick having minimum tensile strength of 550mpa as in ridge, bend to shape for fixing as required, fixed with self-tapping screws. Note:-(i) Colour of prepainted sheet will be as approved by AGE(I). (ii) The bottom colour of sheet must be white.
Repair of valley gutter joint filling with M seal all as specified and directed by engineer - in -charge.
Dismantling wrought iron or mild steel work of any description all as specefied.
M & L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleat etc. compete all as specefied and directed by E-in-Charge. (Fe- 410W Grade-E-250 quality A).
M&L for applying two coats of synthetic enamel paints over a coat of red oxide primer on new steel surfaces over 10 cm width or girth including preparatinon of surfaces complete all as specified and directed by the Engineer-in-Charge.
Dismantling timber scantlings 40 sq. cm and over in section, in any position in unframed work.
S&F for Second class hard wood (SAL) timber framed and fixed in scantling, wrought .
Dismantling wall and ceiling boards (fiber, pulp, insulation etc.) any thickness, including cover fillets etc complete all as specified and directed.
S & F for 4mm thick asbestos cement plain building boards, fixed to timber framework with screws fixed in ceiling complete as ditected.
M/L 2nd class hard wood plain fillets square, rectangular or trangular in section, clean sawn se-cured with nails or brads area exc 6 and n.exc 13 sqcm
M & L for preparation of new surface of ceiling board and applying two coat of white wash.
M&L for PCC1:2:4 type B-0 using 12.5mm graded stone aggregate , as in coping with using necessary form work etc complete.
M & L for preparation of the new wooden surface of any description exceeding 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer
M & L for preparation of surfaces and appling two coat of synthetic enamel paint over one coat of pink primer on wooden surface of any description n exc 10cm width or girth when unconnected with other painting or when painted in different tint on new wooden surfaces.
Taking down cement plaster on brick/stone surface of wall built in cement mortar including racking out joints, hacking for key, scrubbing down with water etc all as specified and directed.
Demolition of brick work built in cement mortar including all quoions, arches pillar etc complete all as specified and directed.
M&L brick work with sub class "B" old size bricks, straight or curved on plan exec 6m mean radius built in CM 1:6 complete all as specified and directed by the Engineer-in-Charge
M & L for rendering 15 mm thick on fair face of brick walls or concrete surface in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M & L preparation of new plastered surfaces on walls and applying two coats of cement paint complete all as specified and directed by Engineer-in-Charge
S&F 6 to 8mm thick poly carbonate sheet of any shape and size including dismantling of poly carbonate sheet in roof coverings including ridges etc complete as specified & directed by Engineer-in-Charge.
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri
HIMANSHU TRADERS
m/s neeraj kumar shukla
M/S R S Traders
M/S Garg Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .