Loading…
Loading…
Tender Value
₹2.6 Cr
EMD Value
₹5.1 L
Closing Date
6 Oct 2026, 3:00 pm
LALIT KUMAR
CHIEF ENGINEER
Siksha Bhawan, Rastrabhasha Parishad, Saidpur, Patna-800004
LALIT KUMAR
CHIEF ENGINEER
Construction of 100 Bedded Building at UMS Isriayan, Kumarkhand in Madhepura District in Bihar Under PM-JANMAN Yojna
139979
NIT-20/2026-27/04
Short Tender
CIVIL
Patna
• Bid Security Amount in Rupees (A) Unconditional bank guarantee from any scheduled Indian bank issued within the state in the format given. 16.1 Total Bid Security Amount in Rupees Rs. 513000/-
• (i) Legal Status of Bidder 4.3(a)
• (ii) Place of Registration.
• (iii) write Principal place of Business
• (iv) Power of attorney of signatory
• Annual Financial Turn Over (Rs in Lakhs) in last five years. - Rs. 128.21 Lac
• 4.5.A To qualify for award of the contract, each bidder in its name should have in the last five years as referred to in Appendix :-
• 4.5.A(a) Total value of Building construction, in Rupees, Performed in last five years - Achieved in any one year a minimum annual financial turnover (in all classes of civil engineering construction works only) volume of construction work of at least the amount equal to the 50 % (fifty percent) estimated cost of works for which bid has been invited. The turn over will be indexed at the rate of 8% for a year - Rs. 128.21 Lakh
• PCC/RCC Work- 261.85 cu.m
• Brick Work- 222.85 cu.m
• Flooring (Vitrified Tiles/ Granite/ Tiles Work) - 894.95 sq.m
• 4.5A(e) PHE work Rs. 4.93 Lakh/-
• 4.5A(d) Electrical work Rs. 9.17 Lakh/-
• ITB 4.7 Amount of Existing commitments and ongoing works in Rupees
• ITB 4.7 Amount of Work for which Bid already submitted, in Rupees
• 4.5(B) (a) Numbers and Maximum age of Equipment with bidder / Type of Equipment Nos. Max. Age
• Concrete Batching & Mixing plant Minimum capacity 15m3/hr - 1 No, Maximum age - 5Y
• Vibrator (Plate & Niddle) - 2 Nos, Maximum age - 5Y
• Water Tanker 1 Nos, Maximum age - 5Y
• 4.5(B) (b) Name of the Personnel and Experience in years
• Site Engineer B.E. (Civil) + 07 Years Exp. (3 years in Building Construction) or retired A.E. - 1 Nos
• Site Supervisor - Fresh Graduate in Civil or Diploma Civil + 03 Years Exp. or retired I.T.I Holder. - 1 Nos.
• ITB 4.7 Bid Capacity of Rs. 25642427/-
• 4.2(i) Evidence of accesses to Financial Resources in Rupees Evidence of access to or availability of credit facilities (10% of estimated cost i.e. Rs. 25.64 Lakh/-), certified by bankers (for work under this bid).
• 4.3(l) Proposed methodology and program of construction, backed with equipment planning and deployment
• 4.3(j) Litigation History, Information regarding any litigation, current or during the last five years, in which the Bidder is involved, the parties concerned, and disputed amount..
• Affidavit Select as indicated in page no 31 of SBD document, regarding statements made in the required attachments are true and correct.
• 4.3(h) Undertaking towards able to invest a minimum of cost up to 25% of contract value of work. During implementation of contract. Sec-2, Undertaking
• Registration No. IT.& GST Registration & clearance Certificate Labor License Character Certificate NOC for Debar (If required)
• Electrical Licence (Self registrataion / Sub-contractor registration with affidavit)
• Licence for water supply/sanitary engineering works (Self registrataion / Sub-contractor registration with affidavit)
CIVIL
PERCENTAGE
L1
1
24 documents required · 24 mandatory
₹10,000
Processing Fee: 5900
₹5.1 L
AT CE OFFICE BSEIDC PATNA
18 Sept 2026
18 Sept 2026
6 Oct 2026
23 Sept 2026
6 Oct 2026
23 Sept 2026
25 Sept 2026
Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth : consolidating each deposited layer by ramming and watering lead.
Supplying and filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level.
Centring and shuttering including strutting, propping etc. and removal of form for:
Foundations, footings, bases of columns, etc., for mass concrete.
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Post and struts
Stairs, (excluding landings) except spiral staircases.
Vertical and Horizontal fins individually or forming box louvers band, facias ane eaves boards.
Wheather shade, Chajja, corbels etc., including edges.
Edges of slabs and breaks in floors and walls :
Metre
Reinforcement for RCC work including straightening. Cutting, bending, placing in position and binding all complete.
TMTC-500- 8mm dia .
TMTC-500-10 mm dia.
TMTC-500-12 mm dia.
TMT FE-500-16 mm dia.
TMT FE-500-20 mm dia.
TMT FE-500-25 mm dia.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cementcontent as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and including retard setting of concrete, improve workability without impairing strength and admixtures in recommended proportions as per IS: 9103 to accelerate,reinforcement,durability as per direction of Engineer-incharge.
All work above Plinth level upto floor V Level.
Brick work with bricks of class designation 100A in foundations and plinth in:
Brick work with bricks of class designation 100A in Super Structure (1:6)
Half brick masonry with bricks of class designation 100A in Super Structure in C.M(1:6)
Extra for providing and placing in position 2 Nos, 6 mm dia , MS bars at every third course of half brick masonry
Providing and fixing factory made single extruded WPC {WoodPolymer Composite} solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 Suspension Grade),calcium carbonate and natural fibers {wood powder/ rice husk/wheat:
Providing and fixing aluminium sliding door bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Providing and fixing factory made uPVC approved colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multichambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners,
Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).
Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value58-60 (Suspension Grade), calcium carbonate and natural fibers(wood powder/ rice husk/wheat husk) and non toxic additives withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimumFrame size 65 x 125 mm
Providing and fixing circular/hexagonal cast iron or M.S sheet box for ceiling fan clamp 140 mm internal dia, 73 mm height, 5 mm thick rim bottom and top lids, 1.5 mm thick M.S sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless ent as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete
In gratings, frames, guard bar, ladders, railings, brackts. gates & similar works.
Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel primer
metre
Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete.
Providing and laying Vitrified tiles in different sizes (thickness to bem specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such shades except white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cementand matching pigment etc., complete.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Motar 1:3 (1cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Extra for pre finished nosing in treads of steps of Kota stone / sand stone slab.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete asper the architectural drawings with 18 mm thick stone slab over 20 mm (average)thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in- Charge.e.
Cement concrete flooring 1:2:4(1 cement:2 coarse:sand:4 graded stone agregate) finished with a floating coat of neat cement including cement slurry, etc. but excluding the cost of nosing of steps etc. complete.
12 mm cement plaster of mix
15 mm cement plaster on rough side of single or half brick wall of mix.
6 mm cement plaster to ceiling of mix.
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.
New work (two or more coats) over and including priming coat with cement primer.
Applying priming coat:
With ready mixed red oxide zinc chromate yellow primer of approved brand and manufacture on steel galvanized iron/steel works
Painting with synthetic enamel paint of approved brand and manufacture to give an even shed.
Forming groove of uniform size from 12 x 12 mm and upto 25 x 15 mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
Neat Cement punning
Finishing walls with Acrylic Smooth exterior paint of required shade :
Grading roof for water proofing treatment with Cement concrete 1:2:4(1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavemerts etc.
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed protions of W.C. kitchen and the like consisting of :
Providing plinth protection .75 m wide consisting of 12 mm thick cement plaster 1;6 with neat cement punning over 75 mm thick P.C.C. (1:3 :6) over brick flat soling over 75 mm thick local sand filling all complete
Making khurras 45 x 45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1cement:3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m all kind of soil
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base.the drain duly.plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/l,
Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less
Meter
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including, cutting and making good the walls etc. (internal work)
Metre
Metre
Metre
Metre
Metre
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :
Metre
Metre
Providing and fixing brass stop cock of approved quality (screwed end).
Providing and fixing brass gate valve with C.I. wheel of approved quality (screwed end).
Providing and fixing gun metal non-return valve of approved quality (screwed end)
Providing and fixing P V C connection pipe with brass unions.
Providing and fixing C.P. brass shower rose 15 or 20 mm inlet.
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :
Metre
Metre
Metre
Metre
Metre
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc.complete (new work)
Providing and fixing C.P. brass,bib cock of approved quality conforming to IS : 8931
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS stamdards and weighing notless than 810 gms.
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS stamdards and weighing notless than 690 gms.
Providing and fixing C.P brass stop cock (concealed) of standard design and of approved mark conforming to IS:8931
Providing and fixing PTMT Soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Cutting holes up to 30 x 30 cm in walls including making good the same:
Making holes up to 20 x 20 cm and embedding pipes upto 150 mm in diametre in masonary and filling with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) including dispopsal of malba.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :
Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fittings complete.
Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers comelete.
Providing and fixing 600 x 120 x 5 mm glass shelf with edges rounded off supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc. complete
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
Providing and fixing on wall face unplasticised PVC (working pressure 4 kg per sqcm) rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
Metre
Providing and fixing on wall face unplasticised PVC moulded fittings / accessories for unplasticised-PVC rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
Providing and fixing unplasticised-PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S screws or required length including cutting brick work and fixing on cement mortar (1:4) 1 cement:4 coarse sand and making good the wall etc. complete.
Providing and fixing water closet squatting pan (Indian type W.C pan) with 100mm sand cast iron P or S trap, 10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
Providing and fixing white vitreous china pedastal type water closet (European type W.C pan) with seat and lid, 10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
Providing and fixing Salem Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S 13983 with C.I brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required.
Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality colour and make, weighing not less than 105gms.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200mm wide with a minimum distances of 37mm fromwall face with concealed fittings arrangement of approved quality, colour and make weighing not less than 90 gms.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) alround S.W. pipes inlcuding bed concrete as per standard design.
Metre
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mmthick with cement mortar 1:3 (1 cement : 3 coarse sand), finishedsmooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 Metre depth below ground level.
Meter
Supplying, assembling, lowering and fixing in vertical positionin bore well, unplasticized PVC medium well casing (CM) pipeof required dia, conforming to IS: 12818, including required hireand labour charges, fittings & accessories etc. allcomplete, for all depths,as per direction of Engineer -in-charge
Meter
Meter
Supplying, assembling, lowering and fixing in vertical positionin bore well unplasticized PVC medium well screen (RMS) pipeswith ribs, conforming to IS: 12818, including hire & labourcharges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
Meter
Gravel packing in tubewell construction in accordance with IS:4097,including providing gravel fine/ medium/ coarse, inrequired grading & sizes as per actual requirement, all complete as per direction of Engineer
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap orspot welded plate to the top of bore well housing/ casing pipe,removable as per requirement, all complete for borewell of:
Providing and fixing M.S. clamp of required dia to the top ofcasing/ housing pipe of tubewell as per IS: 2800 (part I),including necessary bolts & nuts of required size complete
Providing and fixing Bail plug/ Bottom plug of required dia tothe bottom of pipe assembly of tubewell as per IS:2800 (part I).
Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FR PVC insulated copperconductor single core cable in surface / recessedmedium class PVC conduit with modular switch ,modular plate, suitable size G.I. box etc as required.
Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI. Box and earthing the point with 1.5 sq. mm. FR PVC insulated copper conductor single core cable etc as required.
Wiring for light/ power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required.
Supplying and drawing following pair 0.5 sq.mm. FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface / recessed steel / PVC conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following modular o switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing suitable size Gl box with modular plateproviding and fixing 3 pin 5/6 amps modular socket outletand 5/6 amps modular switch, connection etc. as required.
Supplying and fixing suitable size Gl box with modular plateand cover in front on surface or in recess includingproviding and fixing 6 pin 5/6 & 15/16 amps modular socketoutlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing following way horizontal type three pole and neutral sheet steel ,MCB distribution board 415 volts on surface recess,complete with tinned copper bus bar,netural bus bar earth bar dinbar interconnections,powder painted including earthing etc as requried (But without MCB/RCCB/Isolator) 6way (4+18) double door.
Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required.
Providing and fixing copper tape 20 mm x 3 mm thick on parapet or surface or wall for lighting conductor complete as required, (For horizontal run)
Providing and fixing copper tape 20 mm x 3 mm thick on parapet or surface or wall for lighting conductor complete as required, (For vertical run)
Supply and installation of 300 mm, 230 v A.C. exhaustfan in the existing opening including making good thedamage, connection testing, commissioning etc asrequired.
Supply and installation of regular/standard model A.C.ceiling fan of 1200 mm sweep including wiring thedown rods of standard length (upto 30 cm) with 1.5 sq.
Supplying and fixing 4'X20 watt LED batten with minimum efficacy 100 lm/w in aluminium housing and complete with integrated electronic driver etc directly on walll ceiling including connections with 1.5 sq.mm FRLS pVC insulated copper conductor etc. as required. (For Non-residential building)
Supplying and fixing fotrlowing types LED Flood light withminimum efficacy 100 lm/w in die cast aluminium housing,toughened glass, lP 66 protection and complete withelectronic driver etc on poleibuilding including connection earthing the body etc as required. 100wt
Supplying and fixing of following types lamp in theexisting electrical fitting/ fixtures etc. as required.
Wiring for circuit/ submain wiring alongwith earth wirewith the following sizes of FR PVC insulated copperconductor, single core cable in surface/ recessedmedium class PVC conduit as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Providing and fixing lighting conductor finial,made of 25mm dia 300 mm long ,copper tube having single prong at top ,with 85mm dia 3mm thick copper base plate including holes etc
3.5 core, 150 sq. mm XLPE/PVC insulated PVC sheathed (Heavy duty) armoured electric cable with aluminium cond uctor
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required.Single pole
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supplying and fixing 2 pin ,6 amp celling rose on the existing junction box/wooden block including connection etc as requried
Supplying and fixing brass batten/angle holder including connection etc.as required
Providing and fixing following rating and breaking capacityand pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required
Providing and fixing following capacity busbar chamberwith 4 strips of suitable size made of copper, heavy duty,complete with all accessories including connections, earthing the body etc. as required.
Providing and fixing following capacity double pole/ fourpole OFF-load changeover switches with side handleoperation, in sheet enclosure in existing metal board,including drilling holes in metal panel, making connections etc. as required.
63 amps. TPN switch disconnector fuse unit,
32 amps. TPN switch disconnectorfuse unit, rewireable
supplaying and fixing wall /floor mounted cubical board fabrication with 18 guage iron sheet suitable for panel mounted switch discoonecto including bus bar chamber insulator nut boult indicator switch amper digital ct coil voltmeter digital
Supptying and fixing following rating, 24Al4L5 volts, "C"curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB Dbcomplete with connections, testing and commissioning etc. as required'
Brand new ISI marked Life Guard ABC type multipurpose Fire Extinguishers 4 Kgs. Capacity, fitted with pressure guage complete in all respects, ready to use, complete installation kit.
Amount (In Rs.)
p c c=.75mm
l.s.f = 150mm
sqm/kg
kg/ sqm
Qty as per item no 8.2
Bricks (Nos)
Description of Work
Wiring for light point/ fan point/ exhaust fan point / call bell point with 1.5 Sq.mm FR PVC insulated copper conductor cable in recessed PVC conduit with modular type switch , modular plate, suitable size GI box etc as required.
Point
Supplying and fixing suitable size GI box with modular plate and cover in recess including providing and fixing modular type 3 pin 5/6 amps socket outlet & 6A switch connection etc. as required.
Supplying and fixing of suitable size GI box with modular plate and cover in recess including providing and fixing modular 6 pin 15/16 amp socket outlet &15/16 amp modular switch including connection,painting etc as required
Wiring for light/ power plug plug with 2 X 4 sq. mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Meter
Meter
Meter
Meter
Meter
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required
Meter
Supplying and fixing electronic musical call suitable for single phase, 230 volts complete bell as required.
Supplying and fixing modular type 25 amps A.C. unit box with ON/OFF MCB on surface or in recess complete with connections, testing and commissioning etc as required.
Supplying and fixing Suitable G.I box with modular plate & cover in front of surface or in recess including providing and fixing 4 nos. 3 pin 5/6 amps modular socket outlet & 4 nos 5/6 amps modular switch, connnection etc as required.( Use for computer point)
Supplying and fixing following way, horizontal type,three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing single wall mounted 18/22 watt LED type batten fitting complete with electronic driver and LED tube etc directly on wall/ ceiling including connections with 1.5 sq.mm FR PVC insulated copper conductor and earthing the body etc. as required.
Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required. 15 watt LED lamp
Supplying and fixing Surface mounted 15/18 watt LED downlighter complete with integrated electronic driver & LED directly on ceiling including connection with 1.5 sq.mm FR PVC insulated copper conductor cable and earthing the body etc. as required.
Supplying and fixing 4' X 40 watt suspended type LED luminaire provides soft-light and glare free symmetrical illumination complete with all accessories etc. including ball and socket arrangement, 2 no. down rods of 20mm dia X 1.6
Supplying and fixing 90 watt LED type street light with die cast aluminium housing for ingress protection of IP65 and complete with all accessories etc, on pole/building including connection with FR PVC insulated copper conductor cable and earthing the body etc. as required.
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV/ HPSV/ CFL street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc.as required.
Supply and installation of 300 mm, 230 v A.C. exhaust fan in the existing opening including making good the damage, connection testing, commissioning etc as required.
Supplying and fixing wall/floor mounted cubical panel board, fabricated with 16 gauge iron sheet, suitable for panel mounted switch disconnector, including bus-bar chamber, insulator and painting etc. as required. (but without busbar copper strip)
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
Providing and fixing following capacity four pole ONload/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing Copper strips 50x5mm sizefor busbar including inter connection etc as required
Supply and fixing digital voltmeter, three phase in the existing cubical panel board including drilling holes in the panel board, making connection etc as required.
Supply and fixing digital Ammeter, three phase with C.T. coil in the existing cubical panel board including drilling holes in the panel board, making connection etc as required.
Supplying and fixing Pilot lamp for indication.
Supplying and drawing of following size of ISI marks FR PVC insulates singke core copper conductor cable for inter connection of main switch/ busbar main switch etc as required.
Supplying of following size& core PVC XLPF insulated Sheathered unmounted electrical cable with aluminium conductor for working voltage upto 1.1 kv as required
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
per set
Operation of lift under free maintanance for period of 1 year including 3rd party inspection charge for 8 hours daily.
Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
Supplying of following size& core PVC XLPF insulated Sheathered unmounted electrical cable with aluminium conductor for working voltage upto 1.1 kv as required
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required.
per 50 kg cement
metre
Per 1000 Nos.
tonne
per 1000 nos
Specification
Structure is made up of 40 mm dia CRC tube with thickness 18 gauge. Horizontal base is made from steel sheet the thickness 14 gauge. Horizontal base will be stiffened with appropriate longitudinal 3 v shape sheet and lateral stiffeners 2 steel pipes with powder coating. Manufactured out of ISO 9001, ISO14001 and OSHSAS 18001 certified Plant and product certified for BIFMA performance test (Size : 2000 x 900 x 650 mm (H)
Supplying and fixing of Mattress (size : 75"x36" x 2" thick) at site, with complete in all respect or as per direction of E/I
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT-20 (2026-27) Complete Document-32.pdf
NIT • 0.19 MB
BOQ-04.xls
NIT • 0.41 MB
SBD2026NIT20SL04.docx
NIT • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .