| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC H NO 11 1 MATHRU NILAYA 7TH MAIN 3RD CROSS NEAR GAUTHAM COLLEGE OF PHARMACY BHUVANESWARINAGAR RT NAGAR BANGALORE 560 032 | BENGALURU URBAN | KARNATAKA | 560032 | L1 | Accepted-AOC AOC | |
| 2 | L2₹36.0 L+₹3.3 L (10.2%)Rejected-Finance 6 A FIRST MAIN NEAR JAMIYA MASJID ISLAMPUR ANNASANDRAPALAYA HAL VIMANAPURA POST BANGALORE 560 017 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560017 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹36.0 L+₹3.4 L (10.3%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹37.0 L+₹4.3 L (13.3%)Rejected-Finance D NO 44 38 12 23 4 AVS PARADISE SRINIVASA NAGAR AKKAYYAPALEM POST VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹37.1 L+₹4.4 L (13.5%)Rejected-Finance NO 6 G 2 SS ENCLAVE 1ST MAIN 1ST CROSS INDIAN EXPRESS LAYOUT VIRUPAKSHAPURA VIDYARANYAPURA POST BANGALORE 560 097 | BENGALURU URBAN | KARNATAKA | 560097 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
19 Jun 2023, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE North Bangalore
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
CLEARING OF VEGETATION CLEANING OF SERVICE TANKS PERIODICAL SERVICES AT MD OTM ACCN OF DGQA OTM ACCN OF PRTC AND 106 INF BN AREA UNDER GE NORTH BANGALORE
2023_MES_598005_1
8408
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
Class D Category a(i)
7 documents required · 7 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹84,000
Yes
28 Jun 2023
24 May 2023
21 Jun 2023
24 May 2023
19 Jun 2023
6 Jun 2023
24 May 2023 - 6 Jun 2023
Amount
Material and labour for spraying antiweed / non toxic solution / chemicals containing Glyphosate as per manufacture instructions and removing the weed including the roots after ensuring complete de-germification of plant / weed and cutting down the plant/trees off from roof/top sides of external walls of bldgs, in chajjas, wall junctions, junctions of GI/CI/AC/PVC pipes and taking out roots entered in wall/slabs, including making good the surface using PCC 1:2:4 type B1 or cement mortar (1:2) or brick work in CM(1:4) plastered with CM(1:4) including painting to match with existing surface and repairing the pipes and joints which was affected by cutting down/taking out process all as specified and as directed for plants / trees located in the buildings with necessary scaffolding up to First floor, complete all as specified and directed by Engineer-in-charge. NOTE:- Contractor has to execute the work of de-generated plant/weeds as per the prior approval and directions of Engineer-in-charge.
All as per Item No 1 above, but from first floor to second floor
All as per Item No 1 above, but from second floor to third floor
All as per Item No 1 above, but above third floor
Material and labour for cleaning of Roof at any height (on inaccessible roofs) by removing all scale, dirt, mud, any foreign material, accumulated silt, other dirty substance, algae, fungus, leaves etc deposited over slab and making good the distrubed surfaces if any with and including making good the surface using PCC 1:2:4 type B1 or cement mortar (1:2) or brick work in CM(1:4) plastered with CM(1:4) to match with existing surface up to First floor and removing the material so obtained out side complete all as specified and directed by Engineer-in-charge.
Material and labour for cleaning of PVC/RCC over head water tanks at any height (on accessible/inaccessible roofs) by removing all scale, dirt, mud, any foreign material, accumulated silt, other dirty substance, algae, fungus and any other bacterial material from sides/bottom of tank, cleaning shall be done by draining / pumping out water / sludge from bottom, by high pressure water jet of pressure not less than 120 PSI for removing clogged mud/scales etc and cleaning the same again with self priming pumped fresh water and disinfecting the water tank by using UV radiator and approved chemical (chlorite), after cleaning writing letter / figures (Date of cleaning and next Date of cleaning) on black back ground with white synthetic enamel paint including removing the existing letters/ figures complete all as specified and as directed for capacity of water tank exc 250 & n. exc 500 lit capacity.
All as per Item No 6 above, but Exc 500 litre N.exc 1000 ltr capacity
All as per Item No 6 above, but Exc 1000 litre N.exc 2000 ltr capacity
Taking down cement plaster of any description including racking out joints, hacking for key and disposal of debris to out side MD land all as specified and as directed.
M&L for Rendering 15mm thick in CM 1:6 on brick or concrete surfaces , finished even and smooth with out using extra cement.(Internal Surfaces)
M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 with WPC, finished plastered surface even and smooth without using extra cement (External Surfaces) Note :- WPC will be measured and paid separately
Supply only liquid water proofing compound
M&L for Rendering 5 mm thick in CM 1:3 on ceiling surfaces, finished even and smooth with out using extra cement.
Preparation of newly plastered surfaces and applying two coats of oil emulsion distemper over one coat of alkali resistant primer over one coat of chalk whiting putty on plastered surfaces of walls including in narrow widths/ bands etc complete all specified and as directed.
Preparation of newly plastered surfaces and applying two coats of cement base paint over one coat of primer on walls including in narrow widths/ bands etc complete all specified and as directed.
M & L for Complete removal of existing treatment on wall surfaces chajjas etc of any description including brooming down with steel wire brushing, scrapping down smoke soot's, moulds, moss and efflorescence, salts, trading oil and greasy spots etc and applying two coats of Anti fungal weather proof grade exterior acrylic emulsion paint of approved tint (Apex Ultima or equivalent brand as specified in CA) over a coat of weather proof primer including filling the minor racks etc with crack filling material all as per manufacturers instructions complete all as specified and as directed.
M & L 4 mm thick figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 Sqm in each pane all as specified and as directed. incl Hacking out old broken glass of any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips etc complete all as specified and as directed.
M&L for 4mm thick Sheet glass, ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm in each pane all as specified and as directed. incl Hacking out old broken glass of any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips etc complete all as specified and as directed.
Preparation of new plastered surfaces and applying three coats of white wash on ceilings including in narrow widths/ bands etc complete all specified and as directed.
Preparation of old decorated surfaces and applying one coat of white wash on walls including in narrow widths/ bands etc complete all specified and as directed.
Preparation of old decorated surfaces and applying two coats of white wash on walls including in narrow widths/ bands etc complete all specified and as directed.
Preparation of old decorated surfaces and applying one coat of white wash on ceilings including in narrow widths/ bands etc complete all specified and as directed.
Preparation of old painted surface and applying one coat of synthetic enamel paint on steel and iron surfaces over 10cm width or girth all as specified and as directed.
Preparation of old painted surfaces and applying one coat of synthetic enamel paint on wood and wood based surfaces over 10cm width or girth all as specified and as directed.
Preparation of old decorated surfaces including washing, rubbing down and stopping and applying one coat of oil emulsion distemper on walls all as specified and directed.
Preparation of old decorated surfaces including washing, rubbing down and stopping and applying two coats of oil emulsion distemper on walls including necessary putty all as specified and directed.
Complete removal of existing treatment on walls of any description over 10cm girth or width and applying two coats of oil emulsion distemper over one coat of alkali resistant primer over one coat of chalk whiting putty on plastered surfaces of walls including in narrow widths/ bands etc complete all specified and as directed.
Preparation of old decorated surfaces including washing, rubbing down and stopping and applying one coat of oil emulsion distemper on Ceiling all as specified and directed.
Preparation of old surfaces including brooming down with steel wire brushing scrapping down soot’s, moulds, moss and efflorescence, salts, treating oil and greasy spots etc and applying one coat of cement base paint at any position.
Preparation of old surfaces including brooming down with steel wire brushing scrapping down soot’s, moulds, moss and efflorescence, salts, treating oil and greasy spots etc and applying two coats of cement base paint at any position.
S & F in repair 75 mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including necessary fittings all as specified and as directed.
All as per item No 31 above but 110 mm dia .
S&F in repair 75mm dia PVC (SWR) Bends with access door of any radious
All as per item No 33 above but 110mm dia
S&F in repair 75mm dia PVC (SWR) junction single(single T) equal or unequal with access door
All as per item No 35 above but 110mm dia
S&F in repair 110mm dia PVC(SWR) brach piece, single(single Y) equal or un equal with access door
All as per item No 37 above but 75mm dia
S&F in repair 110mm dia PVC(SWR) brach piece, (double Y) equal or un equal with access door
All as per item No 39 above but 75mm dia
S&F in repair 75mm dia PVC(SWR) vent cowl
All as per item No 41 above but 110mm dia
Taking down of existing Water Proofing treatment of any type (APP Membrane, Cement or earthen tile, Mud phuska or lime concrete) including cement plaster of any thickness and removing bitumen coating/mud pushka dirtsetc over original RCC roof slab by grinding, Picking, sweeping clean and washing down with water to remove dust & to providing water prooling treatment complete. Note : Rate includes for removing debris outside defence land
M&L providing cement concrete type B0 1:2:4 (12.50mm graded stone aggregate) in copings, parapets and railing upto 60cm height, leveling concrete for Roof slab, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as including demolition & removal of cement concrete from the MD land of any description and in any position not otherwise specifically provided for complete all as specified and as directed. directed
M & L for providing Water Proofing Treatment to RCC roofs in repairs as per the following specification i) After cleaning Concrete should be thoroughly inspected for any minor cracks on existing roof, and should be sealed with grouting and crack filling materials ii) Cement screed 15 mm thickness in CM (1:4) in slope, admixed with FOSROC Nitobond SBR at 2% by weight of cement equivalent products of Pidilite/ Dr Fixit Super Latex/ Asian Paints/ M/s MC Bauchemic CIPY/ SIKA / Thermax / STP to be applied as per manufacturer's instructions. iii) Clean the surface and apply FOSROC Nitoproof 650 P over a priming coat of FOSROC Nitoproof W Primer or equivalent product of Asian paints Fixit/ Thermax /STP applied as per manufacturer's instructions. iv) Providing and laying / fixing TPO (Thermoplastic Polyolefin) waterproofing membrane on prepared surface of roof & up to 300mm of parapets and crumple joint including junction of roof and parapet by cleaning the surface and laying FOSROC Proofex ORG (minimum 1.2 mm thick for in-accessible roof 2 mm for accessible roofs) with Proofex OGP Adhesive over a min. 200 GSM Geo textile or Asian Paints TPO or equivalent product of M/s MC Bauchemie / CIPY/ SIKA/ Pidilite Dr Fixit TPO membrane, applied as per manufacturer's instructions.
Disconnecting existing tanks, setting aside including necessary connections (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing etc. measured separately).Capacity in litres Exc 250 & n exc 500
Disconnecting existing tanks, setting aside including necessary connections (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing etc. measured separately).Capacity in litres Exc 500 & n exc 1000
Supply & laying 20 mm outer dia CPVC pipes SDR 11 ( Plain CPVC SDR 11 fittings on walls / ceiling or laying in floors including all fittings and specials including taking down 15 mm GI tubing and connections complete all as specified.
Supply & laying 25 mm outer dia CPVC pipes SDR 11 ( Plain CPVC SDR 11 fittings on walls / ceiling or laying in floors including all fittings and specials including taking down 20 mm GI tubing and connections complete all as specified.
S&F in repairs 20mm CPVC gate valves, with lever, screwed both ends for iron pipe and fixed
S&F in repairs 25mm CPVC gate valves, with lever, screwed both ends for iron pipe and fixed
M & L for 500 litres capacity rotational moulded, triple layer polythene water storage tanks (cylindrical vertical with closed top) hoisting and fixed in position on roofs including 20 mm dia ball valve and fittings including dismantling existing water storage tank, complete all as specified.
M & L for 1000 litres capacity rotational moulded, triple layer polythene water storage tanks (cylindrical vertical with closed top) hoisting and fixed in position on roofs including 25 mm dia ball valve and fittings including dismantling existing water storage tank, complete all as specified.
S & F in repairs 20mm bore dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms) all as specified and as directed.
S & F in repairs 25mm bore dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed.(Minimum weight 20mm-210gms / 25mm-455gms) all as specified and as directed.
MAA ENGINEERING SERVICERS
S M Shetty
Chaitanya Constructions
VIKAS CONSTRUCTIONS
NAVREET CONSTRUCTION
SP ENTERPRISES
Ravees Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .