| 1 | L1₹2.8 LAccepted-AOC 182 INDRA COLONY VILL DAMODARPURA POST TODABHATA TEA BASSI BASSI JAIPUR JAIPUR RAJASTHAN 303301 | JAIPUR | RAJASTHAN | 303301 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹4.3 L+₹1.1 L (34.8%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹4.8 L+₹1.7 L (52.5%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹4.9 L+₹1.7 L (54.5%)Rejected-Finance | L4 | Rejected-Finance BEING L4 |
Tender Value
₹7.5 L
EMD Value
₹15,000
Closing Date
28 Apr 2020, 6:00 pmClosed
GE (WEST) HISAR
GE WEST HISAR HISAR MIL STN HISAR-125006
DAY TO DAY MAINTENANCE AND RE-WIRING OF CERTAIN BUILDINGS AT EBS AND BHOJRAJ AT HISAR MIL STN UNDER GE (WEST) HISAR
2020_MES_335964_1
GE(W)/HSR-57/2019-20
Open Tender
Civil Works
Item Rate
330 days
HISAR MIL STATION
pl refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (WEST) HISAR
₹15,000
Yes
25 Jun 2020
23 Mar 2020
30 Apr 2020
23 Mar 2020
28 Apr 2020
14 Apr 2020
Amount
Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed.
Taking down carefully copper/aluminium Submain wiring from battan /conduit from DBs,MCBs, etc) and making good to disturbed surfaces of walls, floor etc. all as specified and directed
M&L for point wiring for one light / bell/ fan point controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FRLS drawn through existing rigid PVC coduit and conduit accessories existing concealed type in walls/ceilings and including change of steel terminal sunken boxes and 3 mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for one light point/fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FRLS connected to common earth dolly complete complete all as specified and directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).
All as per item No. 3.00 above but for one 5 pin 5 Amp socket outlet on independent board controlled by one number one way switch on independent board.
All as per item No. 3.00 above but for one 5 Pin 5 Amp socket outlet on the same board controlled by one number one way switch on same board.
All as per srl item No. 3.00 above but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi strand on independent board including provn of 2.50 Sqmm unsheathed, multi stranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed.
M&L for point wiring for one light / bell/fan point controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FRLS drawn through PVC casing & caping and including change of steel terminal sunken boxes and 3 mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for one light point/fan point/bell/buzzer point controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FRLS connected to common earth dolly complete complete all as specified and directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).
All as per item No. 7.00 above but for one 5 pin 5 Amp socket outlet on independent board controlled by one number one way switch on independent board.
All as per item No. 7.00 above but for one 5 Pin 5 Amp socket outlet on the same board controlled by one number one way switch on same board.
M&L for point wiring for one light / bell/fan point controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FRLS in and including concealed PVC conduit 20 mm dia medium duty ISI marked, steel terminal sunken boxes and 3 mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for one light point controlled by one switch including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FRLS connected to common earth dolly complete including cutting, chasing the surface and then making good the same in CM (1:3) complete all as specified and directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ).
All as per item No. 10.00 above but for one 5 pin 5 Amp socket outlet on independent board controlled by one number one way switch on independent board.
All as per item No. 10.00 above but for one 5 Pin 5 Amp socket outlet on the same board controlled by one number one way switch on same board.
All as per item No. 10.00 above but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi strand on independent board including provn of 2.50 Sqmm unsheathed, multi stranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed.
S&F switch piano flush type, single pole, one way, 5/6 Amp, 230/240 Volts grade complete all as specified and directed.
S&F switch piano flush type, single pole, one way, 15/16 Amp, 230/240 Volts grade complete all as specified and directed.
S&F bell push flush type, 5/6 Amp 240 Volts complete all as specified and directed.
S&F flush type socket outlet multipurpose 3 Pin 5/6 Amp (with 2/3 pin outlet also) 230 volts AC complete all as specified and directed.
S&F flush type socket outlet multipurpose 3 Pin 15/16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed.
S&F ceiling rose surface bakelite, 3 terminals with back plate etc complete all as specified and directed.
S&F in repair sheet metal enclosure distribution board TPN, 4 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs with min 200 Amp rating copper bus bar, complete all as specified & directed.
S&F in repair sheet metal enclosure distribution board SPN, 8 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs with min 200 Amp rating copper bus bar, complete all as specified & directed.
S&F in repair sheet metal enclosure distribution board SPN, 4 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs with min 200 Amp rating copper bus bar, complete all as specified & directed.
S&F MCB TPN, 63 Amps 240 Volts , type 'B' curve, 10 KA, fixing in DB complete all as specified and directed.
S&F MCB SPN, 32 Amps 240 Volts , type 'B' curve, 10 KA, fixing in DB complete all as specified and directed.
S&F MCB SP, 6 to 32 Amps 240 Volts , type 'B' curve, 10 KA, fixing in DB complete all as specified and directed.
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through and including concealed conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed. (Note:- Two lengths of 6 Sqmm cable, one length of 6 Sqmm cable and one length of PVC conduit will be measured as one length).
All as per item No. 27 above but for Two runs of 4 Sq mm size main cable and one run of 4 Sq mm size earth continuity conductor
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 4 sqmm, 1100 votls grade drawing through and including PVC casing and caping with acessories and including PVC insulated 4 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed. (Note:- Two lengths of 4 Sqmm cable, one length of 4 Sqmm cable and one length of PVC casing and caping will be measured as one length).
S&F Lamp holder of PVC / Polycarbonate type surface for CFL / bulb etc complete all as specified and directed.
S&F Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed.
S&F in repair sheet metal enclosures with socket plug top and MCBs single pole and neutral enclosure with a 2 pin and earth plug and socket complete with one single pole MCB of 20 Amp rating 240 volts, type 'B' curve complete all as specified and directed.
S&F in replacement LED street light luminaries of cap 20 watt, SPD, 10KV internal with lense 240 volt, ,pressure dia cast aluminium housing frame, heat resistant toughtened clear glass with frame complete with accessories , IP 65 protection, pre wired up to a terminal block and mounting attachment,including pvc connector for connection complete all as specified and directed.
S&F in replacement LED light fittings 36/42 watt recess Mounting, 2"x2" Sheet aluminium housing with high quality LGP and PMMA diffuser. Separate HPF driver 240 volt along with fixing arrangements complete all as specified and directed.
Attending of complaints pertaining to faulty/Non-functional/ working state of all accessories pertain to internal Electrification / through telephone or in person round the clock on detailment by MES Service centre for Offrs/JCOs/ORs Md/OTM Accn of Hisar Mil Stn by deploying electrician and locating and rectifying the fault from Elect Meter/DB onwards in respect of Sub Main /Point wiring including fixtures for power and light, socket, fan, bell point including security light fitted in bldgs etc complete and carrying out repairs to the extent of disconnection and dismantling of faulty wires, battens, conduits, boxes, Main switches, MCB, DBs, and other E/M faults pertaining to particulars equipment including providing wire upto 2.00 mtr and insulatiion tape required for the rectification of defect and refixing of existing dismantling serviceable articles complete all as specified and directed
Note :- (i) Scope of work shall include replacement of bulbs /tubes/ switches/socket/regulator/bell /MCB/ sheet metal enclouser/holder etc shall be measured and paid separately as " Supply only ". Old fitting fixtures held by users which will be handed over the repairer if so required. (ii) Complaint pertaining to location and rectification of fault in more than one wiring point/sub main wiring/DB etc shall be considered as one complaint. Similarly complaint pertaining to replacement of minimum three fixtures in one BK/qtr/office/bldg involving movement of electricians will also be measured and paid as one complaint. Replacement of more than three fixtures but multiple of four fixtures or part thereof in one Bk/qtr/office/bldg etc will be measured as additional complaint. (iii) The complaint slip/job card shall be prepared round the clock by the MES Staff/ Supervisor and shall be handed over to contractor’s tradesmen. Complaint slip shall be got singed by user with name, number and rank and return the same to MES staff by same day. Complaints of emergent nature e.g no light, short circuiting and earth fault etc. shall be attended, round the clock. Other complaints can be attended during normal working hours.In case complaint has not been attended with in stipulated time frame as per its priority class, suitable recovery on this account shall be made on the rates as specified here-in-after.
(iv) Bldgs requiring major nature of work e.g rewiring of complete bldg or major portion shall be intimated to JE E/M and separate team shall be deployed for the work. (v) Bldgs requiring rewiring of small qty of point wiring if ordered will be measured and paid separately. (vi) Cost of work requiring replacement of other stores will be measured as supply only and paid separately. (vii) Contractor shall provide the complain slip and containing 100 pages in triplicate properly binded and complaint book as per sample on requirement basis complete all as specified and directed.
Supply only socket out let 15A, 5 pin, multipurpose type complete all as specified and directed
Supply only MCB TPN, 63 Amps 415 Volts , type 'B' curve, 10 KA, fixing in DB complete all as specified and directed.
Supply only MCB SPN, 32 Amps 240 Volts , type 'B' curve, 10 KA, fixing in DB complete all as specified and directed.
Supply only MCB SP, 6 to 32 Amps 240 Volts , type 'B' curve, 10 KA, fixing in DB complete all as specified and directed.
Supply only sheet laminated 3 mm thick including cutting required size drilling holes for incorporating switch, socket, regulators etc. complete all as specified and directed..
Supply only LED tube rod only 18/20W, 4ft suitable for existing tube light fitting all as specified and directed. Make-Havells , Bajaj CG Syska or equivalent.
Supply only of capacitor 2.5 to 3.15 mfd as per existing capacity of 240V A.C complete all as specified and directed.
Supply only switch piano flush type, single pole, one way, 5/6 Amp, 230 Volts grade complete all as specified and directed.
Supply only bell push flush type 5 amps complete all as specified and directed.
Supply only piano type switch 15 Amps, single pole one way flush typecomplete all as specified and directed.
Supply only socket outlet 3 Pin 5 Amps Multi purpose Piano type, flush type complete all as specified and directed. .
Supply only ceiling rose surface bakelite, 3 terminals with back plate etc complete all as specified and directed.
Supply only lamp holder insulated body with back plate suitable for batten fittings complete all as specified and directed.
Supply only fan regulator electronic ,450w,250v step type suitable for 1200/1400mm sweep ceiling fans complete all as specified and directed.
S&F in replacement of LED tube light fitting 18W metallic frame /batten, Retro, Box type surface and wall mounted, including LED tube light rod , high efficiency including making connection, complete all as specified and directed.
S&F in replacement of LED light fitting complete 1x9W , (2Ft long) poly carbonate batten including LED Tube, including making connection, complete all as specified and directed
Supply only PVC casing and caping, 20mm width complete all as specified and directed.
Supply only 1100 volts grade heavy duty cable PVC insulated aluminium stranded/Solid conductor, served with inner sheathing of PVC sheathed wire, one twin core cable flat or circular of 10 sqmm complete all as specified and directed.
Supply only 1100 volts grade heavy duty cable PVC insulated aluminium stranded/Solid conductor, served with inner sheathing of PVC sheathed wire, one twin core cable flat or circular of 6 sqmm complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/ equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore upto 7.50 metre long GI pipe light grade for earth wire protection fixed with poles/wall with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.
fauji electric works
M/s Rao Constructions, 1173 Urban Estate-II, Hisar
YASHU CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .