Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC NO 29 1 YADAV STREET KARALAPAKKAM THIRUVALLUR DIST CHENNAI 602 024 | CHENNAI | THIRUVALLUR | TAMIL NADU | 602024 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹8.8 L+₹32,347.36 (3.81%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹9.3 L+₹77,550.30 (9.13%)Rejected-Finance NO 15 PULAVAR GOVINDAN STREET GANDHI NAGAR AVADI CHENNAI 600 054 | AVADI | CHENNAI | TAMIL NADU | 600054 | L3 | Rejected-Finance Not Lowest |
Tender Value
₹10.0 L
EMD Value
₹19,962
Closing Date
10 Jun 2023, 6:00 pmClosed
AGE I RD AVADI
AGE I RD AVADI CHENNAI
REPAIRS TO FLOOR/ WALL TILES AND WATER TANKS AND OTHER CONNECTED WORK AT RESIDENTIAL AREA AT CVRDE AVADI
2023_MES_594135_1
8570/E8
Open Tender
Civil Works - Others
Item Rate
180 days
AVADI
As per tender documents
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹19,962
Yes
13 Jul 2023
9 May 2023
12 Jun 2023
9 May 2023
10 Jun 2023
23 May 2023
Amount
Taking down steel water tubing and connection including cleaning for refixing for 15mm bore pipe and removing from site or work complete all as specified and directed by the Engineer-in-Charge.
Taking down steel water tubing and connection including cleaning for refixing for 20mm bore pipe and removing from site or work complete all as specified and directed by the Engineer-in-Charge.
S&F GI tubes 15 mm bore medium grade with fittings and fixed complete to wall, ceiling or laid in floor complete all as specified and directed by the Engineer-in-Charge.
S&F GI tubes 20mm bore medium grade with fittings and fixed complete to wall, ceiling or laid in floor complete all as specified and directed by the Engineer-in-Charge.
Re-fixing old serviceable GI tubing 15mm bore and connection complete all as specified and directed by the Engineer-in-Charge.
Re-fixing old serviceable GI tubing 20mm bore and connection complete all as specified and directed by the Engineer-in-Charge.
Demolition of cement concrete (un reinforced ) in ground floors and pavings not exceeding 15 cm thickness(below or above ground level),complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises.
M&L for PCC 1:2:4 Type B0 (using 12.5 mm graded stone aggregate), as in floor of 25 mm thick complete all as specified and directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1: 6 complete all as specified and as directed.
M&L for Glazed ceramic coloured tiles in vertical surface 350x450x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick plaster in CM 1:3 complete all as specified and dricted.
M&L for Vitrified Ceramic tiles (Light Shade) 10 mm thick (square/ rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1: 6 complete all as specified and directed.
M&L for Vitrified Ceramic tiles (Light Shade) 10 mm thick (square/ rectangular) area of each tile not exceeding 0.36 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick backing coat in CM 1: 3 complete all as specified and directed.
M&L for 150mm thick Cement concrete type C-2, 1:3:6 (40mm graded aggregate) for PVC tank platform over the roof flat surface including necessary form work complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks 500 ltrs (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of existing tank all as specified in SSR Part I all as specified and directed by the Engineer-in-Charge.
S&F Rotational moulded polyethylene water storage tanks 1000 ltrs (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of existing tank all as specified in SSR Part I all as specified and directed by the Engineer-in-Charge.
S/F 20 mm dia ball brass valves high pressure ,with polythene float and fly nut complete,screwedfor iron pipe or brass ferrule fixed in repair complete all as specified and directed by the Engineer-in-Charge.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed for 20mm bore pipe all as specified and as directed.
K Kumar Construction
D Subramani and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .