| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAccepted-AOC | ₹2.2 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹2.4 Cr+₹17.6 L (8.03%)Rejected-AOC ONLOOKER BUILDING 3RD FLOOR 25 SHRI P M ROAD FORT MUMBAI 400 001 | MUMBAI | MAHARASHTRA | 400001 | ₹2.4 Cr+₹17.6 L (8.03%) | L2 | Rejected-AOC Reject due to other than lowest |
| 3 | L3₹2.4 Cr+₹18.3 L (8.35%)Rejected-AOC BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | ₹2.4 Cr+₹18.3 L (8.35%) | L3 | Rejected-AOC Reject due to other than lowest |
| 4 | L4₹2.4 Cr+₹19.0 L (8.64%)Rejected-AOC NOT AVAILABLE | ₹2.4 Cr+₹19.0 L (8.64%) | L4 | Rejected-AOC Reject due to other than lowest |
| 5 | L5₹2.5 Cr+₹28.0 L (12.8%)Rejected-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400708 | THANE | MAHARASHTRA | 400708 | ₹2.5 Cr+₹28.0 L (12.8%) | L5 | Rejected-AOC Reject due to other than lowest |
Tender Value
₹2.9 Cr
EMD Value
₹3.7 L
Closing Date
2 Mar 2020, 6:00 pmClosed
CWE NW MUMBAI
DR HOMI BHABHA NAVY NAGAR ROAD COLABA MUMBAI
SPECIAL REPAIR TO BUILDING P 11 AT NAVY NAGAR UNDER GE NW NAVY NAGAR COLABA MUMBAI
2020_MES_319659_1
8180/CWE(NW)/MUMBAI
Open Tender
Civil Works
Item Wise
330 days
GE NW NAVY NAGAR
Class B and Category a (i)
9 documents required · 9 mandatory
₹2,000
Yes
GE NW NAVY NAGAR
₹3.7 L
Yes
27 Apr 2020
29 Jan 2020
3 Mar 2020
29 Jan 2020
2 Mar 2020
20 Feb 2020
29 Jan 2020 - 20 Feb 2020
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises including removing the debris from MD land
Supply & fix Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0. 11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match over 15 mm thick screed bed or bedding layers in CM (1:4) complete all as specified and directed
Material & labour coloured Glazed ceramic tiles in vertical surfaces 350 x 250 x7 mm/ 450 x 350 x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick cement plaster in CM (1:4) as a back layer for receiving the tiles etc complete all as specified and directed
Material & labour Virified Ceramic tiles 9/10 mm thick light shade (square/ rectangular) polished, of size 600 x 600 , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:4) etc. set and jointed in neat cement slurry and grouted with epoxy grout to match complete all as specified and directed. Note :- Cost of 15 mm thick screed bed is included in the rate
Material & labour for grinding ,rubbing and polishing on existing Grenite sufaces in floors and steps to match new surfaces complete all as per direction by Engineer- in-Charge
Supply & fix wall tiles of 800 mm x 100mm and 12 mm thick set & jointed in neat cement slurry & pointed in white cement mixed with colour pigment to match the colour of tiles over and including 15 mm thick cement plaster in CM (1:4) complete all as specified & directed by Engineer- in-Charge. (Make: Duracrete/ Ultra Tiles or equivqalent) Note :- Pattern and design of the tile shall be as per approval of Garrison Engineer (NW)
Supply & fix Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop at of primer; erected in position as indicated, complete: push pull or manual type thickness of lath is 1.25mm including taking down old shutters complete all as specified and directed
Taking down and refixing of steel rolling shutters with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop at of primer; erected in position as indicated, complete: push pull or manual type size not exceeding 10 sqm each complete all as specified and directed
Material & labour granite tile 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white/coloured cement with admixture of pigment to match the shade of granite store including cutting and polishing etc including 15 mm thick screed bedding layer in CM (1:4) complete all as specified and directed
Material & labour granite tile 20mm thick in verticle surfaces as in steps/riser etc machine cut, bedded and jointed with grey cement slurry and pointed with white/coloured cement with admixture of pigment to match the shade of granite store including cutting and polishing etc including 10 mm thick rendering in CM (1:3) complete all as specified and directed
Rounding to edges of stone slabs (kota/granite etc) one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed
Extra for forming grooves over granite or kota stone slab as in staircase complete all as specified and as directed
Material & labour for preparing old plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed
Demolition of cement concrete un-reinforced not exceeding 15 cm thick of any description and at any position complete all as specified and directed
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work including cutting of reinforcement cut as required to facilitate demolition including removing of debris out side MD land. Note :- Reinforcement cut as reqd to facilitate to demotion
Supply & fix chinaware under counter wash basin of size 550 mm x 425 mm x 195 mm including CP waste coupling and PVC waste pipe complete all as specified and directed
Supply & fix brass chromium plated pillar cock long sunk with auto closing system fixed at counter top complete all as directed and as specified.
Material & labour Vitreous China Urinal,half stall type with grating, white (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brassscrews, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
Push Cocks for Urinal complete all as specified and directed
Material & labour Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed
Material & labour in repairs vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including connection to trap/drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc complete including making good to floor
Material & labour plastic water closet seat, black, closed pattern with recessed bottom, and cover and mild steel chromium plated or aluminised hinging device
Supply & fix CP Jet with 600 mm long connection pipe fixed to water closet pedestal pattern complete all as spfd & directed fixed in repairs.
Material & labour 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets in repairs
Supply & fix brass chromium plated Bib Cock with flange complete all as specified and directed
Supply & fix brass chromium plated angular stop cock (concealed) with flange complete all as specified and directed
Supply & fix PVC connectors of 15 mm size with PTMT nuts of length 600 mm length complete all as specified and directed
Supply & fix 100mm bore CI floor trap with gratings incl jointing to waste pipe in run lead.
Taking down chawkhats or frame (w/o taking off shutters from the frames) but not exceeding 1.50 each.
Supply & fix MS holdfast, wall ties and semilar articles confirming to Fe-410-0 or Fe-310-0 complete all as specified and directed
Material & labour PCC (1:2:4) type CI (20mm graded agg) for fixing of hold fast complete all as specified and directed
Supply & fix solid FRP door frame of size 90 x 40 mm made out 5mm plain colour PVC sheet reinforced with MS square tube made as per specification and drawing. (Make : Sintex/Rajshree/Accucell)
Factory made solid panel FRP moulded door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. (Make : Sintex/Rajshree/Accucell)
Supply & fix 100mm size stainless steel butt hinges complete all as specified and directed
Supply & fix 150 mm long brass matel barrel tower bolts of extruded section complete all as specified and directed
Supply & fix 125mm size brass matel handles, fabricated type anodised complete all as specified and directed
Supply & fix Brass metal sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed of length 300 mm complete all as specified and directed
Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
Supply & fix anodized aluminium DECO grills 7.5mm thick, as existing grills, DG - 102 including aluminium anodized F section complete all as specified and directed
Supply & fix 5.5 mm thick frosted glass ordinary quality in square not exceedingeeding 0.50 sqm each fixed to aluminium window frame complete all as specified and directed
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed
Material & labour for brickwork with subclass ‘B’ bricks, straight or curved on planot exceedingeeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed
Material & labour for brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4)
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
Material & labour Sand faced cement plaster 20 mm thick in two coats using factory manufactured pre mix/ready mix of 'Roofit Mix'of M/s Premier Floor to Roof Materials pvt.ltd/ 'Easy plast' of M/s Walplast Products pvt.ltd/ 'Readiplast' of M/s Ultratech Cement Ltd/'Soundplast PMC-1' of M/s Sound buildcare pvt.Ltd/ or other approved equivalent make, having minimum composition of C:S :: 1:4 using fully treated dry, well graded natural sand conforming to IS 383 suitable for external plastering, having low rebound properties, low water demand for curing properties, mechnIcal mixing with water in a metalic tray only to make good consistency as per the specification of the Manufacturer and applied over exterior masonry and concrete surfaces with base coat of 12 mm thick and finishing coat of 8 mm thick final rendering,including using richer mix for making corners if necessary, at all floors and level, including making grooves of existing size wherever required, including cleaning the surfaces, curing etc. complete all as per specifications & as directed by the Engineer-in-Charge
Material & labour two coat of rain coat pidilite or equevelent exterior grade over a one coat of primer including prepartion of newly plasterd surfaces of walls etc all specified on external surfaces (Make : Asian Paint (Apex)/Nerolac (1sr quality)/Dulux (weather shield)
Material & labour plastering 15 mm thick on other than fair faces of brickwok or concrete surfaces of wall in cm 1:6 and finishing the surface even and smooth without using extra cement and finally providing sagol finish complete all as specified and directed
All as per item no 48 above but 10 mm thick in ceiling
Complete removal if existing treatment from old plastered surfaces of wall and applying two coats of oil bound distemper over a coat of chalk whitening with wall putty complete (Make : Asian paints/Nerolac paints/Shalimar Paints)
Supply & fix Pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. (For sunshades )
Supply & fix Framed brackets / puline of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc conforming to Fe 290 Gde E-165.
Drilling and fixing teflon nozzles in RCC members including drilling holes, drilling holes 12 mm dia, 50 to 100 mm deep holes in structrual members at the intervals of 300 to 500 mm in staggered manner or as directed by the consultants in RC structural element. Cleaning of holes : Clean the holes by air blower prior to fixing of nozzles. Fixing of nozzles : Insert 12 mm dia teflon nozzles in claned holes. External end of nozzles to be machine to receive oulet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for minimum 12 hours. Cutting of nozzles : Cut the nozzles by chie=esel after completion of grouting without damaging structural elements.
Material & labour for injecting of site cement slurry grout, in the ration 1:2 (1-cement, 2-water) including super plasticizer (supercom-100) 250 ml/50 kgs. Mixing shall be donw by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 0.50 kg/sq cm etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled. (for repair to slab)
Injecting low viscosity (3-5 cps) high molecular weight by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, including mixing of material as : Mixing of material componets quantities as per manufacturer's instruction by weigh batching. Grouting : Fill the grouting gun with concrete penetrating corrosion inhibitor EPCO-KP-100. Maintain desired pressure in the gun by air compressor, maintain the pressure at exit (2 to 3 kg/sqcm) by monitoring pressure guage at exit. Grout the material through prefixed nozzles in the structrual elemts @ 100 ml per nozzle. repeat the process for all the nozzles. (Beams and columns)
Building up the profile of structrual members by using latex addidtives (MONOBOND) modified air cured mortar system( Polymer modified mortar)( 1:5:15 = 1 monobond- 5 cemnt- 15 sand) in damaged area in 30mm thicknes including leveling, profiling etc, complete all as specified and directed.
Material & labour for chipping, removing carefully concrete work by low impact hammer, breaker without damaging the structure and cleaning and disposal of debris out side the premises etc complete as directed by Engineer- in-Charge. Hard concrete should not be removed by force.
Material & labour for cleaning existing reinforcement with wire/rotary wire brush, making the surface free from loose material dirt etc, complete applying two coats of alkaline rust converting primer (i.e. rust remover) FEOVERT conforming to ASTM-B-117, on the rebars (measurement shall be on the basis of exposed concrete) (Make : Feovert of Krishna Conchem, Roff rust cleaner of Pidilite, Dr Fixit Rust remover, ShaliRustOff of STP Ltd)
Material & labour for providing and applying two coats of anti-rust protective coating in the form of Acrylic Polymer mixed with Cement in 1:1.5 proportion (1 partpolymer and 1.5 parts Cement) on rebars after cleaning of rust scales as per manufacturers instruction (measurement on the basis of exposed concrete area). (Make : IPNET of Krishna Conchem, New Coat from Dr Fixit
Material & labour for providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster or micro concreting conforming ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bonding between old concrete and new concrete
Material & labour for providing and applying jacketting around columns/beams with micro concrete (Molith-MC) M-40 including all lifts, shuttering , drilling holes and fixing shear anchor as per specification complete all as specified and directed. Note :- (a) Reinforcement shall be measured and paid seprately. (b) Rates including jacketing, formwork and micro concrete)
Providing and erecting steel props (upto 14' height wooden at centre and supporting a continious 2" x 3" wooden runner, resting on wedge and block minimum capacity 1 ton ) to support the structure provisionally during repair and jacketing etc. amd maintaining them in position till required as directed by the cunsultant.
Providing and fixing MS/TS dowel pins/staple/shear pins including drilling holes in concrete and providing labour including polyster resin based grouting materials for grouting the pins sourced from manufacturer's such as Fosroc or Krishna Conchem/shear connector HILTI
Material & labour for replacement of steel reinforcement with TMT bars of appropriate size where 20 % of cross section is reduced including dismantling of rusted steel including application of rust convertor FEOVERT and applying protective coating IPNET - R B complete all as specified and as directed
Preparaing of new steel surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer
Material & labour for stainless steel letters of height 60 cm and cross sectional size 75mm x 35mm with closed ends, made out of 1.50mm thick stainless steel plate, including necessary cutting, welding, rounding etc complete and fixing at a height of maximum 10.00m all as specified and directed. Note :- Font and wording with letters will be as decided by GE.
Material & labour for stainless steel special alloy grade 316 TI pipes, Hollow section , any dia & thickness as in railling, ladder incl bending to required shape, cutting, notching organ welding, riding and drilling counter sunk holes and bending to required shape by mechanical means in factory as per site requirement without forming wrinkles and butting and polishing all as directed by Engineer-in-Charge.
Material & labour for preparing steel surfaces old over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer
Demolition of plain cement concrete in any description and any position not otherwise provided for i.e. PCC padding including roof treatment with any type of membrane (APP /glass fibre /hassian base felt) etc complete and taking down the debris from roof of height not exceedingeeding. 18m and removing debris outside MD land all as directed.
Cutting chases, pinning in and making good to facings of brick/concrete/stone walling where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting not exeedingc 10 cm girth complete all as specified and directed
Material & labour for Providing, cement concrete type B1 1:2:4 (20mm graded stone aggregate) in PCC padding / levelling coarse on roof slab, kerbs or mud stops, rounded or chamfered on edges, laid over RCC roof finished even and smooth without using extra cement complete all as specified and directed.
Material & labour for providing 10 mm thick rendering on cement concrete surfaces in cement mortar (1:4) mixed with water proofing compound whilst the concrete is green , finished even & smooth without using extra cement compete all as specified and directed. (Note: WPC will be measured & paid separately)
Providing roof treatment as under : - (a) Applying bitumenous primer @ 0.30 litres per sqm over cleaned and dry roof surface including parapet. (b) Material & labour for applying a coat of blown bitumen 85/25 grade @ 1.20 kg per sqm over priming coat of roof (c) Providing and laying 4mm thick APP modified polyester reinforced water proofing memberane with minimum weight of 3.5 kg/sqm , as spefieid. The APP membrane shall be laid using torch-on application with minimum 10 cm side overla and 15 cm end overlapl. The APP memberane shall be fixed with termination bar and fasteners and end shall be properly sealed with sealant. (Make : Pidilite Industries/STP/IWL) (d) Providing polypropylene/polyester, non-woven geotextile fabric of 150 gsm
Material & labour cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry over and including 20 mm thick cement screed in CM (1:4) over APP membrane at roof, and cut and polished
Taking down & fixing New PVC pipes of 110 mm dia & to any height including clamping to wall with screws completed all as specified and directed. (a) Rate Quoted shall be of Scaffolding upto 6th floor. (b) Quoted Rate inclusive of all new fittings of PVC pipe where reqd.
Dismantling wrough iron or mild steel work of any description not otherwise provided for embedded in PCC /Brick work all as specified and directed.
Material & labour Framed work such as in ladder with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe Fe 290 Gde E-165 all as specified and directed.
Excavating in trenches, not exceedingeeding 1.5m wide and not exceedingeeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceedingeeding 10 Sqm on plan and not exceedingeeding 1.5m in depth and getting out
Material & labour PCC 1:4:8 type D2 ( 40 mm graded aggregates) Cement concrete in foundations, filling and mass-concrete etc complete all as specified and directed.
Material & labour reinforced cement concrete M-20 (using 20 mm graded stone aggregate) foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
Material & labour reinforced cement conrete M-20 (using 20 mm graded stone aggregate) as in columns pillars, posts and struts etccomplete all as specified and directed
Material & labour reinforced cement conrete M-20 (using 20 mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5 m span complete all as specified and directed
Material & labour reinforced cement conrete M-20 (using 20 mm graded stone aggregate) slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat surfaces complete all as specified and directed
Use and waste of formwork to the sides of pillars, posts, struts, piers, columns complete all as specified and directed
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
Use and waste of formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceedingeeding 200mm thick (Horizontal or sloping) complete all as specified and directed
Material & labour Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to TMT bars complete all as specified and directed
Material & labour 5 mm dia and over upto 10 mm dia in stirrups spacers and binders confirming to TMT bars complete all as specified and directed
Supply only water proofing compound ISI marked.
Material & labour broken stone & boulders hardcore of gauge not exceedingeeding. 63 mm, deposited, spread and levelled in layers not exceedingeeding. 15 cm thick, watered and rammed to a true surface complete all as specified and directed
Material & labour 75 mm thick plain cement concrete (1:3:6) type C-1 (using 20 mm graded aggregates) as in sub base flooring finished even and smooth without using extra cement all as specified and directed.
Supply & fix Alluminium strips 100 x 6 mm thick in 600 mm x 600m as in frame work for fixing of 12 mm thick tough end glasses in front side of shops fixed with screws to RCC structure in open spaces complete all as per maufactureers instruction
Material & labour in repairs for anodised aluminium snap grid frame work for false ceiling with and including 8 mm thick gypsum board (size of grid 605mmx605mm) including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil all as specified and directed.
Removing excavated material outside MD land exceeding 1.50 km but not exceedingeeding 15 km and depositing where directed.
Taking down carefully copper/ aluminium point wiring ie. light, fan, socket or power/points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of ceiling, walls, floors, etc.
Material and Labour for Point wiring complete with proper colour coding using, 1100 volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor conforming to IS-694, part-II, ISI marked and including concelled wiring drawn in PVC conduit not less than 25 mm size, ISI mark with all accessories on wall/ceiling/floor/roof etc, including sutable size of PVC board or uni modular PVC board with including plate and frame cover with ISI marked for fixing of modular or non modular fittings including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for the following :- Note :- Circuit conductor from MCB DB to Switch boards should not be less than 2.5Sqmm. Rate deemed to be inclusive of making good the disturbed surface and finished the surface as per the existing colour. Make of PVC conduit :- Poly plast/Pressfit/ Presto plast/Precision and Make of cable-Havells /Finolex/Plaza/Polycab
One light/Exhaust/Ceiling fan point controlled by one switch
One 3 pin switch socket combination 5 Amps on the same board with other switches.
One 3 pin switch socket combination 5 Amps, independent.
All as per item No 98 above but with 4 Sqmm cable with 4 Sqmm FRLS cable as earth wire for one three pin 15 Amps socket out let for AC controlled by one switch complete all as specified and directed. Make of PVC conduit :- Poly plast/Pressfit/ Presto plast/Precision and Make of cable-Havells /Finolex/Plaza/Polycab
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and Supply & fix modular PVC flush box for 1/2 module including blank plate if required all as directed.
All as per Item No 100 above but Supply & fix in replacement with PVC modular flush type box 3 module complete all as specified and directed
Supply & fix in replacement with PVC modular flush type box 4module complete all as specified and directed
Supply & fix in replacement with PVC modular flush type box 8 module complete all as specified and directed
Supply & fix in replacement of ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm complete all as specified and directed
Supply & fix in replacement of modular switch piano, 1 module, single pole one way 6Amp complete all as specified and directed. Make- Legrand (Britzy)/Anchor(Roma)/ Crabtree(Athena)
Supply & fix in replacement of modular socket 2/3 pin combine, 2 module, 6A complete all as specified and directed. Make- Legrand (Britzy)/Anchor(Roma)/ Crabtree(Athena)
Supply & fix in replacement of modular stepped type fan regulator, 2 module, single pole one way complete all as specified and directed. Make- Legrand (Britzy)/Anchor(Roma)/ Crabtree(Athena)
Supply & fix in replacement of modular white cover plate with frame, 8 module complete all as specified and directed. Make- Legrand (Britzy)/Anchor(Roma)/ Crabtree(Athena)
Supply & fix in replacement of modular white cover plate with frame, 4 module complete all as specified and directed. Make- Legrand (Britzy)/Anchor(Roma)/ Crabtree(Athena)
Supply & fix in replacement of modular white cover plate with frame, 3 module complete all as specified and directed. Make- Legrand (Britzy)/Anchor(Roma)/ Crabtree(Athena)
Supply & fix in replacement of modular white cover plate with frame, 1/2 module complete all as specified and directed. Make- Legrand (Britzy)/Anchor(Roma)/ Crabtree(Athena)
Supply & fix MCB DB SPN conforming to IP 43 - IK 09 with acrylic door, 8 way complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces. Make :Legrand/ Siemens/ L & T
Supply & fix in replacement of MCB SPN, 40 to 50 Amp, 10 KA, 230 Volt. Make : Legrand/ Siemens/ L & T
Supply & fix in replacement of MCB SPN, 10 to 32 Amp, 10 KA, 230 Volt. Make : Legrand/ Siemens/ L & T
Supply & fix in replacement of MCB, single pole, upto 20 Amp, 10 KA, 230 Volt. Make : Legrand/ LT / Siemens
Material & labour for replacement of submain wiring in PVC conduit using 2 runs of 10 Sqmm PVC insulated stranded copper conductor, single core, FRLS incl single run of 10 Sqmm stranded conductor as earth wire all as specified and as directed by Engineer- in-Charge. Make of cable: Finolex/L&T/Havells / Plaza
Supply & fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 25 Amps MCB, 10 KA, 240 Volts. Make : Legrand/Crabtree/Siemens.
Taking down unserviceable FTL and supply and fix Slim LED intigrated batten of 20Watt 4ft coolday light with powder coated CRCA decorative patti prewired complete with two Nos of PVC box of size 75x75x20mm for mounting light fittings including new ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x20mm complete. Make of Light Fitting : C&S Cat Part No LTTB4F20WLED/W or BN 021C LED 20S PSU CW GR S2 of Philips or BCLSB20 WH of Bajaj
Taking down unserviceable light fitting fitting any type and Supply & fix Recess mounting LED 2x2 feet luminare, white, 36 watt with built in PIR occupancy sensor including all necessary fixing arrangement including ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x20mm complete all as specified and as directed. Make :Bajaj/Philips/Wipro.
Supply, fabricated and fixing of street light bracket made from 25/32mm bore GI tubing light grade, bent to required shape and fixed to pole/wall by means of MS flat iron clamp with nuts, bolts & washers as required for fitting to the buildings after taking out old unserviceable light all as directed.
Taking out Old unserviceable light fitting and Supply & fix LED 45 Watts building street light in Aluminium PDC housing, toughened glass cover in IP66 protection including connecting with three core copper wire from connector or ceiling rose. Make- Bajaj Cat No-BRTFG45WLEDV2 or C&S Cat No- LTESSI45W LED or Crompton Cat No-LSTS-45-CDL-M.
Supply & fix in replacement of submain wiring with two single core PVC insulated and unsheathed cable with Copper conductor drawn in concealed PVC conduit and using cable size 2 x 1.5 Sqmm incl 1x 1.5 Sqmm earth wire 1100 volt grade stranded copper conductor complete all as specified and as directed. Make of wire :-Havells/Finolex/Plaza. Make of casing caping- Poly plast/ pressfit/ Presto Plast Precision
Supply & fix Analog Time switch 3P Module, 24 hours program, backup of 100 hrs, 16 A currrent capacity with one changeover and Contactor 25A 2 NO inclosed in Metal box encloser with prewired electric connection complete after taking out old, unserviceable one. (Cost of metel encloser, contactor included in the quoted rate) Cat No- TA926453 of Indoasian or equivalent in L&T/Legrand.
Material & labour in replacement of DLP U- PVC adaptable trunking system of four compartment with cover, angles, bends, coupler and all accessories and fitting of size 195x50mm and fixing on wall including taking out old trunking of any type all as specified and directed
Taking out old ceiling fan/Exhaust fan out from ceiling hook safely including disconnecting all electric connections from fan and depositing to MES store, all as directed.
Supply and fixing ceiling fan 1200mm sweep, 230V, 50Hz, BEE rated and energy saving, hanging on ceiling and connect with copper conductor multi stranded 3 core wire of size 14/0.0076. Model : Bajaj/Havells/Orient
Supply and fixing Exhaust fan, 4 blade, heavy duty, double ball bearing, 230V, 50Hz, 300mm sweep having power input 70W speed 1440RPM and connection as required at site with flexible copper cable including supply and fixing of louvers all as per specified and directed. Make :- Havells/CG/Almonard / Bajaj.
All as per Item No 128 above but for meter cabin panel including disconnecting cable connections and electronic meters from old meter cabin panel and fixing & connecting in new insalled panel with provisions of thimble/lugs and making provisions of vision glasses for meter readings including connecting MCB to meter with 2 core 10 sqmm copper conductor cable with proper thimbe and lux and PCC work if required for fixing meter cabin at old meter cabin place, cost shall be deemed, incl in the quoted rate all as specified and as directed by Engineer- in-Charge. as directed . Comprising of the following :-
(a) MCCB 100 A, 4 Pole, 25 KA, thermal magnetic release, Ics=100% Icu - 01 Nos, Cat No- 420055 of Legrand or ABB/L&T/Schneider. (b) MCB DP 63 Amp,10 KA - 25 Nos, Cat No- 408639 of Legrand or ABB/L&T/Schneider. (c) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc - 1 set of make :- L&T/ Legrand/Schnieder/ABB. (d) Phase indicator lamp R,Y & B - (01 Set oet three). (e ) Taking out old Prepaid meter from old panel and fixing, installing existing meter into new meter panel - 25 Nos (f) Material & labour for connecting of submain cable 2 core 10 Sqmm copper conductor from VTPN DB outgoing MCB to meter and from meter to outgoing DP MCB. (g) Making good the disturbed surface of meter cabin room if any damages occures during taking out old panel and installing new meter panel.
Supply & fix in replacement of DPX3 250, MCCB 250 Amps, 4 Pole, 35/36 kA, thermal magnetic release, Ics=100% Icu - 01 Nos for outgoing at SS No-7 of Make- Legrand, Cat No-420249 or equivalent in Siemens/ABB/Schneider.
Material & labour for earthing complete with Galvanised steel earth plate eletrode 60cmx60cmx6mm thick buried directly in ground vertically to (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised Iron Strip of size 32x6mm size, by means of Bolts, Nuts, Check Nuts and washer made of GI or Steel Earth connecting with test point, provision of Charcal and salt in alternate layers, watering pipe 20mm dia medium grade MS funnel with jali, PCC M-15 Type B-1 in pit with XPM not elss than 4Kg per Sqm and Earthpit with cover returning, filling, removing excavated material all as specified in electrical plate No 3 of SSR Part-I making good excavated surfaces such as hard standing refixing machine pressed precast concrete interlocking paver blocks removed during excavation on earthpit to mach existing surfaces after taking out old/unserviceable one complete and testing on completion all as specified and directed by Engineer- in-Charge
Material & labour for Galvanised iron strip 32 x 6mm burried in ground or fixed on walls/floor with suitable saddles and screws beyond 7.5mtr of earth lead connecting with test point after taking out old/unserviceable one complete all as specified and directed by Engineer-in-Charge.
Test point terminal block made of gunmetal /phosphorus bronze of size 75x75x25mm drilled and screwed including 3 Nos, 8mm dia 25mm long hex head screw fixed complete all as specified and as directed.
Supply & fix multicoloured RGB LED under water light IP-68 water proof, 9/12 W with driver including necessary stand for fixing of RGB light all as directed. Make- Signature light/Bajaj/Philips
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding1.5 mtr in depth for laying of cables etc. in any type of soil and getting out all as specified and directed by Engineer-in-Charge. Note : Rate includes removing of paver blocks carefully and stack properly for refixing after laying of cables .
Returning filling in including spreading, levelling, watering and well ramming in layers not exceedingeeding 25 cm in soils complete all as specified and directed
Removing excavated material from the site of work to outside MD land complete all as specified.
Supply, filling, spreading levelling and well ramming the river sand around cable in trenches for cable cushioning all as specified and directed. Note : Punned thickness shall be measured and paid.
Supply & fix machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 100 mm thickness M-50 Grade not less than 0.45 mtr wide for repairing road cut/footpath carried out under Srl No -1.
Supply, laying un-reinforced precast concrete cable cover class LV type 1 flat size 250mm x 150 mmx 40 mm complete all as specified and directed
Cutting existing road surfaces or hard standing 0.45 mtr depth (22 thick comprising bituminuous topping) for laying of pipes/cables and making good disturbed surfaces to match with existing surfaces.
Supply, Fixing, testing and commissioning of XLPE insulated armoured, heavy duty electric cable with aluminium conductor of 300 Sqmm 3.5 Core laid in trenches, fixed on wall, passing through pipes complete including connecting with MCCB/ busbar with the help of proper size thimble, glands, properly as directed by Engineer-in-Charge and taking out existing damaged unserviceable cable of any size complete all as specified and directed by Engineer- in-Charge.
All as per Item No 142 above but of aluminium conductor of size 95 Sqmm 3.5 Core.
Material & labour for 75mm High density poly-ethylene pipes (HDPE) of pressure 4 kgf/cm2 pipe, for road crossing of cable or for cable protection laid in trenches or above ground surface after taking out old oneall as specified and directed. Make- Prince/Dutron/National / Mahavir
Material & labour for GI pipe ,light grade 75/80mm dia for road crossing of cable for cable protection or above ground surface including taking out old one all as specified and directed.
Material & labour for sub main wiring with PVC insulated unsheathed single core multistranded copper conductor two run of 4 sqmm, 1100 volts grade cable, FRLS, drawn through PVC conduit including accessories including one run of PVC insulated unsheathed multistranded copper conductor cable 4 sqmm (green colour) earth wire and connected to earth dolly including crossing in the wall complete all as specified and directed
Supply & fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 25 Amps MCB, 10 KA, 240 Volts.
Supply & fix self contained drinking water suitable for operation on 230V, single phase, 50 cycles, normal cooling capacity 40 ltr per hour, storage capacity 80 Ltr, compressor 230 V, 50 Hz complete with fully stainless steel body complete all as specified and as directed. Model- SDLX8120 (2 Faucets) of Make- Blue Star or equivalent in Voltas/Usha.
Supply & fix water purifier (on line) with sediment filter, carbon block & UV lamp with 200/Lph, fixing water purifier on wall and connecting it with water cooler including all connecting accessories complete all as specified and as directed. Model No- C200, HSN CODE : 84212110 of Make- ALFA or equivalent in Kent/Aquaguard/Eureka forbes)
Chiseling the existing bricks/conc walls and Supply & fix GI tubes, medium grade with all fittings and make good the disturbed surface area as per existing colours complete all as specified.
Supply & fix Stop valves, cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified.
Provn of PCC base for installation of water cooler including provision of waste water drain out complete.
Supply and fixing rotational mouldede polyethylene three layer water storage tanks of 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position including inlet and outlet connection, all as directed.
Idustrial products India
AGRAWAL ASSOCIATES
SHREE JAGDISH FURNITURE CO.
MUKESH CONSTRUCTION CO
Garima Construction Co
M/s. MAYUR ENTERPRISES
RAJ AND CO
Vara Enterprises
Star Construction Co.
Shetty Construction Co
SATYANARAYAN CONSTRUCTION
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .