Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.7 CrAccepted-AOC | ₹3.7 Cr | L-1 | Accepted-AOC The work has been awarded with due approval from TPC-I |
| 2 | L-2₹3.8 Cr+₹5.2 L (1.40%)Rejected-Finance | ₹3.8 Cr+₹5.2 L (1.40%) | L-2 | Rejected-Finance L-2 Bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non-Responsive |
Tender Value
Refer Docs
EMD Value
₹10 L
Closing Date
13 Jan 2020, 12:00 pmClosed
Chief General Manager PPD
Office of the CGM PPD 6th floor Bijulee Bhawan Paltanbazar Guwahati 781001
Supply Erection and Commissioning of 46.92 KM 11KV overhead line of which 45.67 KM with bare conductor and 1.25 KM with covered conductor within Nagaon kanch and Tezpur EC under UDAY 2017_18 Scheme
2019_APDCL_15298_1
UDAY/11 KV FDR/CAR/NKT/35
Open Tender
Electrical Works
Turn-key
300 days
Nagaon Kanch Tezpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹7,000
APDCL
₹10 L
Bijulee Bhawan Guwahati
4 Jun 2020
10 Dec 2019
13 Jan 2020
10 Dec 2019
13 Jan 2020
17 Dec 2019
16 Dec 2019
Supply, Erection and Commissioning of 46.92 KM 11KV overhead line (45.67 KM with bare conductor & 1.25KM with covered conductor) on 9.75 Mtr. PSC pole from newly constructed 33/11 KV sub-stations constructed under NERPSIP scheme within the jurisdiction of Nagaon,Kanch & Tezpur Electrical Circle under CAR, APDCL, funded from UDAY 2017-18 Scheme on full Turn Key mode of contract.
Description of Work / Item(s)
1. Construction of 45.67 KM 11KV overhead line with bare conductor on 9.75 mtr PSC pole within the jurisdiction of Nagaon,Kanch & Tezpur Electrical Circle under UDAY 2017-18 Scheme. (BOQ3)
2. Construction of 1.25 KM 11KV overhead line with covered conductor on 9.75 mtr PSC pole within the jurisdiction of Tezpur Electrical Circle. ( for 5 nos of feeders) under UDAY 2017-18 Scheme. (BOQ4)
3. Installation of 11 kV LA in Feeder emanating from Sub-Stations constructed under NERPSIP within the jurisdiction of Nagaon,Kanch & Tezpur Electrical Circles under UDAY 2017-18 Scheme. (BOQ5)
4. Installation of 11 kV Panel Meter within the jurisdiction of Nagaon,Kanch & Tezpur Electrical Circle under targeted activities under UDAY 2017-18 Scheme. (BOQ6)
Description of Work / Item(s)
Supply and of erection of PSC Pole, 9.75 mtr long with grouting
Supply, fitting & fixing of GI Channel cross arm (100x50x6x2200) mm as per direction.
Supply, Fitting & Fixing of GI 11kV T-Cross Arm with angle size 50x50x6
Supply, fitting & fixing of Pole clamp of GI flat
Supply & erection of ACSR Raccoon Conductor
Supply, fitting & fixing of Tension clamp for Raccoon
Supply, fitting fixing of PG Clamp for Raccoon
Supply, fitting fixing of 11 kV Polymeric Pin Insulator
Supply, fitting & fixing of 11 kV Polymeric Disc Insulator 70 KN
Supply, fitting & fixing of H/W fittings for Disc, B&S, 70 kN, tension type
Supply, fitting & fixing of HT stay set
Supply, fitting & fixing of Stay wire 7/10 SWG
Supply, fitting & fixing of 11 kV Guy Insulator
Supply, fitting & fixing of HT Danger Plate
Supply, fitting & fixing of GI nuts & bolts with washer (assorted)
Supply & fitting of CI earth pipe 1.8 mtr.
Supply & fitting of GI Barbed wire, type A
Supply & fitting of GI wire 6 SWG (for earthing)
Description of Work / Item(s)
Supply and of erection of PSC Pole 9.75 mtr with grouting
Supply, fitting & fixing of G.I. 11 kV 'T' Cross Arm with angle size 50x50x6mm
Supply, fitting & fixing of GI Channel Cross arm (100x50x6x2200 mm)
Supply, Fitting & Fixing of GI Angle size 50x50x6 mm(for cross bracing)
Supply, fitting & fixing of 11 kV polymeric Tension Insulator, 90 KN with clamps, nut and bolts
Supply, fitting & fixing of 11 kV Tension Insulator hardware suitable for 70 sq. mm Covered Conductor with clamps, nuts & bolts
Supply, fitting & fixing of 11 kV polymeric Pin Insulator
Supply, fitting fixing of HT Danger Plate
Supply, fitting fixing of 12 kV Lightning Arrestor, 9KA
Supply & erection of AAA Covered Conductor, 70 sq. mm
Supply, fitting & fixing of GI nuts & bolts with washer (assorted)
Supply, fitting & fixing of CI earth pipe 1.8 mtr.
Supply, fitting & fixing of 11 KV Wedge Connector for bare to CC connection
Supply, fitting & fixing of GI wire 6 SWG (for earthing)
Supply, fitting & fixing of PVC Insulated Cable Ties (Top) for 11 kV Polymeric Insulator)
Supply, fitting & fixing of HT Stay Set
Supply, fitting & fixing of HT Guy Insulator
Supply, fitting & fixing of GI stay wire 7/10 SWG
Supply, fitting & fixing of GI Pole clamp
Supply, fitting & fixing of 11 KV Termination kit suitable for 70 Sqmm CC
Description of Work / Item(s)
Supply and of erection of 12 kV, 9KA Lightening Arrestor, Line type
Supply and erection of AAA Raccoon conductor
Supply, Fitting & Fixing of GI Wire, 6SWG
Supply and erection of CI Earth Pipe 1.8 mtr length, inner dia 100mm, outer dia 110 mm
Supply, fitting & fixing of GI nuts & bolts with GI washer (assorted)
Description of Work / Item(s)
Supply and erection of HT Trivector Meter(Category-A), 3-ph 4W,-/110/√3,-/1A or -/5A, ICS DLMS Compliance, Class 0.5s for feeder metering
Supply, Fitting & Fixing of Flexible Cu wire, 2.5 sq. mm
M/S U.K. ENTERPRISE
M/S U.K. ENTERPRISE
M/S U.K. ENTERPRISE
M/S U.K. ENTERPRISE
M/S U.K. ENTERPRISE
M/S U.K. ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .