Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC | L1 | Accepted-AOC Award of contract to L1 bidder | |
| 2 | L2₹9.1 L+₹55,495 (6.49%)Rejected-AOC | L2 | Rejected-AOC L2 bidder |
Tender Value
₹9.2 L
EMD Value
₹18,480
Closing Date
13 Sept 2024, 3:00 pmClosed
Chief Engineer, CEG, GSO
GSO Annex building, Kalpakkam - 603102
Maintenance of Fire Extinguishers
2024_GSO_822015_1
GSO/CTC/MSD/75/2024
Open Tender
Miscellaneous Works
Item Rate
365 days
Kalpakkam
As stipulated in NIT/tender
8 documents required · 8 mandatory
₹0
₹18,480
22 Jan 2025
21 Aug 2024
14 Sept 2024
21 Aug 2024
13 Sept 2024
30 Aug 2024
22 Aug 2024 - 29 Aug 2024
Amount
Recharging of empty Fire extinguishers with relevant Fire extinguishing medium and Hydrostatic Testing of Fire Extinguishers as per IS:2190, etc., all complete as per detailed specification and as directed by the Engineer-in-charge.
CO2 fire extinguisher of 2 kg capacity
CO2 fire extinguisher of 4.5 kg capacity
CO2 fire extinguisher of 6.5 kg capacity
CO2 fire extinguisher of 9 kg capacity
DCP Type (Mono Ammonuium Phosphate powder) fire extinguisher of 1 kg capacity stored pressure model.
DCP Type (Mono Ammonuium Phosphate powder) fire extinguisher of 2 kg capacity stored pressure model.
DCP Type (Mono Ammonuium Phosphate powder) fire extinguisher of 6 kg capacity stored pressure model.
DCP Type (Mono Ammonuium Phosphate powder) fire extinguisher of 9 kg capacity stored pressure model.
Water Type fire extinguisher of 9 L capacity stored pressure model.
Recharging of empty CO2 Gas Cartridges of capacity 60/90/120/200 g as per IS 4947 as directed by Engineer-In-Charge.
Transportation of Empty/Filled Extinguishers and Cartridges from storage bay at Kalpakkam/Anupuram Township to Manali, Chennai and Vice versa using vehicle like TATA ACE. Note: 1.Rate shall be quoted for trip from Kalpakkam/Anupuram Township to Manali or Manali to Kalpakkam/Anupuram Township as required (excluding loading & unloading). 2. Rate shall be quoted for one day for a net working time of 8 (Eight) hours per day. 3. Tenderer shall note that one trip involves one or more activites of description mentioned above for a net duration of Eight hours.
Transportation of Safety materials related materials (Fire Extinguishers, Personal Protective Equipements from Kalpakkam to Anupuram or Vice Versa using vehicle like TATA ACE. Note: 1.Rate shall be quoted for trip usage of 50 km between and inside the townships as required. 2. Rate shall be quoted for a net working time of 4 (Eight) hours per day. 3. Tenderer shall note that one trip involves one or more activites of description mentioned above for a net duration of four hours.
Cutting across the fire extinguisher shell (4 to 6 mm thickness) of various capacities by using oxy-acetylene gas cutting at storage bay at Kalpakkam Township. Note: Rate is inclusive of cutting gas and Labour charge.
Stenciling on wall by Synthetic Enamel Paint Size & Colours: Circle of 18 cm Diameter in Yelllow colour and Letter Writing (Number/Font of 5 cm size) in Black colour.Location of Stenciling as directed by Engineer-In-Charge.
Supply and Pasting of Operating Instruction and information label
Operating Instruction and information label suitable to Water 9 L/ Foam 9 L/DCP 2 kg, 6 kg, 9 kg/ CO2 - 2 kg, 4.5 kg
Operating Instruction and information label suitable to CO2 - 6.5 kg, 9 kg, 22.5 kg/ Foam 45 L
Supplying & Tying of printed Fire Extinguisher Maintenance history card made of HDPE sheet of 14X10 cm size; tying tag shall be made up of HDPE material as directed by Engineer-In-Charge.
Supply and fixing of Foam Fire Extinguisher Spares
Multipurpose AFFF liquid cans of capacity 550 ml with 6% foam concentrate as per IS 4989
Multipurpose AFFF liquid cans of capacity 3 litre with 6% foam concentrate as per IS 4989
Supply and fixing of CO2 Fire Extinguisher Spares
Nylon washer suitable to CO2 type fire extinguisher hose
CO2 4.5 kg Fire Extinguisher discharge hose with horn as per IS 2878 (Working pressure- 180 kg/cm2, Test pressure -360 kg/cm2)
Safety pin suitable to CO2 Type Fire extinguisher operating wheel
Operating Wheel suitable to CO2 Fire Extinguisher Valve
Supply and fixing of Dry Chemical Powder Fire Extinguisher Spares
Mono Ammonium Phosphate powder for suitable to extinguish ABC class fires as per IS 4308
Sodium Bi-Carbonate powder for suitable to extinguish BC class fires as per IS 4308
Squeez grip brass valve with Pressure gauge suitable to ABC 2 / 6 / 9 kg stored pressure Fire Extinguisher
Hose holding bottom belt suitable to ABC 6 / 9 kg stored pressure Fire Extinguisher
Discharge hose with Nozlle suitable to fix on ABC 6 kg stored pressure Fire Extinguisher
Providing Hydraulic Pressure Testing Pump, core part made out of Stainless Steel 316 Grade, Capable of Testing upto 100 PSI, etc., as per detailed specifications and as directed by the Engineer-in-charge.
V.S.CONTRACTOR
Bidder Name
Dolphin fire Fighters
V.S.CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .