Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹39.8 L+₹14,837 (0.37%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹41.4 L+₹1.8 L (4.50%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹41.7 L+₹2.1 L (5.22%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹42.9 L+₹3.3 L (8.42%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
10 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Kislay Kishore, IDSE
GE (AFA) Hyderabad PIN-500043
ADDN/ALTN TO RAIN WATER DRAINAGE SYSTEM BETWEEN HANGER NO 1 TO 6 AND CERTAIN MINOR/ REVENUE WORKS AT TECHNICAL AREA, AFA HYDERABAD
2022_MES_500433_1
8214/E8
Open Tender
Civil Works
Item Rate
GE (AFA) Hyderabad
As per tender documents
4 documents required · 4 mandatory
₹500
Yes
GE (AFA) Hyderabad
₹80,000
Yes
22 Mar 2022
8 Jan 2022
12 Mar 2022
8 Jan 2022
10 Mar 2022
22 Feb 2022
8 Jan 2022 - 27 Jan 2022
60 days
Amount
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar complete and removing debris off the premises all as specified and directed
Demoltion of plain cememnt concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing debris off the premises all as specifed and directed by Engr-in-Charge
Taking down shutters including frame of any description exc 1 sqm but n.exc 2 sqm each all as specified and directed by Engr-in-Charg
Taking up or down PVC/steel tubing and connections upto 25mm bore including cleaning for refixing etc complete all as directed.
M & L for coloured Non-skid ceramic tiles (square/rectangular) 7 to 8mm thick in floors, area of each tile exc.0.11 sqm but n.exc 0.18 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with matching pigment laid over and including 20 mm thick screed bed in CM (1:6) complete all as specified and directed by Engr-in-Charge.
M & L for Glazed ceramic coloured tiles in vertical surfaces such as dado, skirting etc exc 0.08sqm and n exc 0.16sqm, 7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match laid over and including 15mm thick backing coat/ rendering on vertical surfaces of wall in cement mortar 1:4 complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, fixed in the frame at site as per specification & drawing all as specified and as directed.
S& F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing all as specified and as directed.
S&F 100mm stainless steel butt hinges, medium weight complete all as specified and directed.
S&F 100mm Aluminum anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 100mm extruded aluminium anodised alloy handles fabricated type complete all as specified and directed.
S&F 250 mm aluminum alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete all as specified and directed.
S&F vitreous china wash down water closet (pedestal pattern) white (excluding fixing bolts, flushing cistern ) with plastic water closet seat (white) including fixing of flush pipe to pedestal pan with all joints complete all as specified and directed.
S & F in repair 10 ltrs capacity PVC valveless syphonic action type flushing cistern low level with inlet ball valve, float and handle including brackets and connecting up complete all as directed
S&F 15mm pillar taps fancy type in repairs, cast copper alloy, chromium plated screwed down high pressure, with long screwed shanks and fly nuts, screwed for iron pipes complete all as specified and directed.
S&F 15mm fancy type, chromium plated bib taps, in repairs screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S & F in repairs Two way Bib tap 15 mm size, brass chromium plated rust proof complete Make Parryware Model No - G4067A1 or Equivalent all as specified and directed.
S & F in repairs Angular stop valve, Brass chromium plated 15 mm dia Make :- Parryware Model No G3307A1 or equivalent all as specified and directed.
S& F 15 MM dia Angular stop valve concealed type, Brass chromium plated Make :- Parryware Model No G5053A1 or equivalent all as specified and directed.
S & F PVC connections 15mm size with PTMT nuts of length 450mm all as specified and directed..
S&FTowel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90 gms) complete all as specified and directed.
S&F SS Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F brass chromium plated shower rose 125mm with or without swivel joints including fixing to steel pipe or union complete all as specified and directed.
S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and as directed
S&F of 15 mm bore steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors etc complete all as specified and as directed.
S&F of 20 mm bore steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors etc complete all as specified and as directed.
S & F PVC (SWR) pipes type 'B' of 110mm dia single socketed in any length fixed to walls / floor complete all as specified and as directed
S & F PVC (SWR) pipes type 'B' of 75 mm dia single socketed in any length fixed to walls / floor complete all as specified and as directed
S & F PVC (SWR) bend of 75 mm dia all as specified and directed by Engr-in-Charge. .
S&F 110mm bore PVC SWR bend of 110 mm dia all as specified and directed by Engr-in-Charge. .
S&F 110mm bore PVC SWR bend with acces door complete all as specified directed by Engr-in-Charge. .
S&F 110mm bore PVC SWR branch piece single 'Y' equal or unequal all as specified and directed by Engr-in-Charge. .
S&F 75mm bore PVC SWR branch piece single 'Y' equal or unequal all as specified and directed by Engr-in-Charge. .
S&F 110mm bore PVC SWR junction single (single T) equal or unequal all as specified and directed by Engr-in-Charge. .
S&F 110 mm bore PVC SWR junction single tee with acces door complete all as specified and directed
S&F in repair Chromium plated health faucets (hand held shower type) with shut off valve (thumb or push button type) to allow controlled and continuous flow of water with adequate length and wall mounted pedestal for hanging the faucet etc complete. Make Parryware model No 19941A1 or equivalent all as specified and directed by Engr-in-Charge. .
S&F in repair Toilet paper holder of vitreous china fixed to walls with chromium plated (CP) brass screws complete all as specified and as directed.
Taking down of cement plaster of any description or thickness/chipping of cement concrete in any situation from brick or concrete surface including raking out of joints, hacking for key scrubbing down with water to receive new plaster and removing the rubbish off the premises complete all as specified and directed
M & L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even & smooth without using extra cement complete all as specified and directed by Engr-in-Charge. .
M&L for applying one coat of Oil emulsion distemper on walls including preparation of old surfaces complete all as specified and as directed.
M&L for applying one coat of Oil emulsion distemper on ceiling including preparation of old surfaces complete all as specified and as directed.
S & F in repair 110 mm PVC (SWR) gully trap setting and jointing with solvent cement all as specified and directed by Engr-in-Charge. .
M&L for Plain Cement concrete (1:2:4) type B-0, (using 12.5 mm graded stone aggregate) as in padding/ levelling course complete all as specified and directed.
M&LCutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. in brick walls and making good, disturbed surfaces, cutting not exc 10 cm girth all as specified and directed by Engr-in-Charge. .
Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required of superficial area of wall nexc 150 Sqcm all as specified and directed by Engr-in-Charge. .
Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required of superficial area of wall exc 150 Sqcm and n.exc 400 sqcm all as specified and directed by Engr-in-Charge. .
S&F 32mm dia PVC flexible waste pipe for WHB/sink all as specified and directed by Engr-in-Charge. .
Removing building materials etc. (other than materials considered under schedule of credit) upto a distance of 5.00 km, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed.
Taking down Precast RCC jallies complete all as specified and as directed
S & F powder coated aluminium window and ventilator shutters side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
S&F powder coated aluminium frame for doors, windows, ventilators, partitions etc with one or more rebates including joining cleat for fixing etc. complete all as all as specified and directed.
S&F 4mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified.
S&F in repair wash basins, Vitreous china flat back of size 550mmx400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed.
S& F Tubular towel rail 20mm dia chromium plated 600 mm long ,fancy type complete all as specified and directed.
S&F 32mm dia brass chromium plated bottle traps for wash basin with inlet and outlet screwed for pipe or connections including necessary packing, union and cap complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out Hard/dense soil complete all as specified and as directed.
M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removing excavated materials (soil) to a distance exc. 1.50 km but n exc. 5 km and depositing where directed at a level n. exc 1.5m above the starting point all as directed by Engr-in-Charge.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L Cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in sub base flooring complete all as specified and directed by Engineer in charge
S&F Pre polished Machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness M-40 Grade laid over and including sand cushion of 50mm (average) thickness duly watered and consolidated complete laid to pattern dry using machine compaction all as specified and directed by Engineer in charge.
M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in Hard/Dense Soil complete all as specified and directed.
M& L for Plain Cement concrete (1:4:8)Type D2 ( using 40 mm graded stone Aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M& L for Pre-cast cement concrete block masonry (1:3:6) type C1 (using 20 mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, for walls/ as in lining the edges of interlocking tiles complete all as specified and as directed.
M&L for Plain Cement Concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in coping cills, bands, plinth courses, kerbs, bed plates, lintels upto 1.5m clear span, edges of interlocking tiles etc including weathering, slightly rounded or chamfered angles, throating and necessary form work complete all as specified and as directed.
M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even & smooth without using extra cement complete all as specified and directed
M&L for applying two coats of cement base paint over a coat of primer including preparation of newly plastered wall surfaces complete all as specified and as directed.
M& L for 100 mm thick Plain Cement concrete (1:4:8) Type D2 (using 40 mm graded stone Aggregate) as in sub base flooring complete all as specified and as directed.
M&L 100 mm thick plain Cement concrete (1:2:4) type B-1, ( using 20mm graded stone aggregate) as in floors, finishing concrete surfaces even and smooth without using extra cement complete all as specified and as directed.
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade 'A' complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in hard/ dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as pecified and as directed.
S& F Basketball Pole Height adjustable, 03 M (10ft) with FRP board of size 1800 x 1050mm including ring and net complete all as specified and as dircted.
M&L for Cement concrete in PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
S&Fof Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 all as specified and as directed by Engr-in-Charge
M&L for Rolled MS Fe 410 Gd E250 in Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc.connecting with bolts/welding to baseplates etc complete all as specified and as directed.
M&L for MS bolts and nuts made with hexagonal or square headed one end and screwed the other and to be fitted with washer and one nut n exc 30 cm long complete all as specified and as directed
S&F Pre painted galuvalume aluminium zinc coating GI based corrugated sheet 0.5mm thick of any colur having tensle strength of 550Mpa as in roof covering/cladding to wall with self tapping screws complete all as specified and as directed.
S&F Pre painted galuvalume aluminium zinc coating GI based plain sheet 0.5mm thick of any colur having tensle strength of 550Mpa as in roof covering/cladding to wall with self tapping screws complete all as specified and as directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of redoxide zinc crome primer on Surfaces of any description,over 10 cm in width or girth, not otherwise described complete all as specified and as directed.
M&L point wiring (surface type) using 1.5 sqmm nominal cross sectional area copper conductor multistranded ,PVC insulated unsheathed 1100 volts grade, FRLS cables in and including PVC casing and caping and fittings/ PVC conduits, including 1.2mm thick pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor , FRLS, green PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed for:-
(a) One light point controlled by one switch
(b) One Exhaust fan point controlled by one switch
(c) One three pin socket 5 Amps plug point on same board
S&F of ceiling rose, three terminal, PVC/polycarbonate, isolated body, ISI marked complete all as specified and as directed.
S&F Switch piano flush type polycorbonate type , single pole 1 way, 5A, 240Volts complete all as specified.
S&F Socket outlet 2 in 1 , 3 pin 5 Amp complete all as specified.
S&F LED light fitting 1x20 W 220V AC decorative box type with driver holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. all as specified and directed by Engineer-in-Charge.
S&F LED light fitting mirror type with high out put diffuser 2 feet 10 W fitting 1x10 W 220V AC decorative type with driver holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. all as specified and directed by Engineer-in-Charge.
M&L for Sub Main wiring with ERLS two runs of 4sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable size with all necessary fittings, on surface in walls/roof/floor duly earthed with one run of FRLS single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge. Note:-(i) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate. (ii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. (iii) Three runs of cable and one run of PVC conduit / casing caping will be measured as one uint.
S&F of MCB DB 4 way SPN double door, 230volts 50 Hz AC supply including fixed to the existing wall (concealed/surface) and making good the disturbed surfaces of wall with the exsting wall finish complete all as specified and as directed.
S&F MCB SPN 6 to 32A, 10KA rupturing capacity complete all as specified and as directed.
S&F MCB SP 6 to 32 A 10 KA rupturing capacity complete all as specified and as directed.
S & F exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230 V, 50 Hz, RPM 1200 copper winding of sweep 250mm including making necessary opening on stone/brick masonary wall of suitable size complete and finishing it properly and making good with matching colours with the surrounding including provision of cable 3 core of size 0.5 Sqmm from ceiling rose to fan complete all as specified and directed.
S & F DB with sheet metal enclosure240 volts, 6 way single phase double door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete all as directed
Supply & Fixing exhust fan plastic body AC single phase 230 V of size 150mm sweep with louvers incl provision of cable 3 core of size 0.5 Sqmm from ceiling rose to fan complete all as specified and directed.
Supply , Laying and testing cable XlPE insulated , screened ,PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium condcutor of size 16 Sqmm 4 core laid in trenches or fixed on walls/ floors/ceiling etc all as specified and directed by Engr-in-Charge
Excavation in trenches in hard / dense soil not exc 1.5 m wide , exc 1.5 m and not exc 3.0 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables complete all as specified and as directed.
M&L River dry sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including punning to a thickness up to 18 cm and consolidation, complete all as directed. Note :- Punned thickness only will be considered for payment.
Supply & lay common burnt, clay building bricks, sub class 'B' designation over the sand cushioning in cable trench for protection of cables (LT) complete all as specified and as directed
Removing surplus excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed
S & F steel tubular swaged poles complete with CI base plate and finial taper plugs, bolts, nuts and screw as specifed of type 410 SP-44 (10 meter long) including applying two coats of Aluminium paint over a coat of red oxide primer all as specified and directed .
S & F cable junction box 200 x 160 x 98 mm in size, made out of thermoplastic, having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32-02 N0 & M- 25 -01 N0 ) fixed on poles with aluminium clamps of size 25 x 3, nuts, bolts, washers etc with busbar including 25 Amp MCB -02 Nos .complete all as specified and as directed Make Cat No . K-8250 of HENSEL or equivalent in SPELSBERG/Sintex
S&F LED flood light fittings 1x 150/160 watt LED pressure die cast aluminium housing heat resistant toughned glass with frame , IP-66 protection , uniform distribution with approved design of bracket duly approveed by Eingineer- in -charge , complete all as specified and as directed . Make:-Crompton Cat Part No:- LFLN-150-CDL/Havells Cat Part No:- JITAIRISFLS150LED757PASYMLTG/Luker Cat part No LFL160 or equvalent
S & F Low Density Poly Ethylene (LDPE) flexible pipe of size 40 mm dia and of pressure rating 6 Kg/cm² laid inside the P.C.C. coping of poles for easy bending and passing of cables including clamping in a proper way all as specified and directed.
M&L for cutting of road / hard standing upto 0.3m in depth and 0.45m wide for laying of cable protection pipe including refilling, watering, well ramming and finishing with PCC 1:2:4 type B1, (using 20mm graded stone aggregates) and matching with surroundings, removing the broken P.C.C / road materials and clearing the site complete all as directed by Engineer-in-Charge.
S&F PVC insulated, sheathed,flat twin core cable with stranded copper conductor of size 2.5 sqmm drawn through inside the steel pole duly connected with the light fitting and cable junction box complete all as specified and as directed.
Supply, installation, testing and commissioning of LT Feeder Pillar box cubical type (CPRI Approved) out door type, mounted on pedestal, suitable for accommodating the following accessories totally enclosed self supporting structure/cubicle, fully compartmentalized type, weather proof, protection IP-54, suitable for outdoor use, with bottom cable entry with suitable cable glands, made out of 3.15 mm thick CRCA steel sheets (IS 5039) with mounting on pedestal type foundation ,arrangement for bus bars, Voltmeter, Ammeter, indicator lamps and MCCB s, with sloping canopy at top, one Nos. of double hinged door at front, with suitable locking arrangement; Provision of louvers at sides, structure treated under 8-Tank metal treatment process and duly painted with powder coated paint of approved shade . The box shall be suitable for 415 Volts,50 HZ, 3 Phase, 4 Wire system complete with suitablesize of PVC copper conductor,thimbles,glands etc all as specified and directed by Engineer in Charge . (a) 04 Nos. aluminium bus bar,150 Amps, with porcelain base and brass screws for mounting.(1.5 times the incoming switchgear current rating) (b) Incoming : MCCB, 4 pole, 125 Amps, 415 Volts, 16 KA, with adjustable setting, – 01(One) No. (c) Outgoing : MCCB, 4 Pole, 40 Amps, 415 Volts, 10 KA, with adjustable setting, – 04( Four) Nos. (d) LED Type Indicating Lamp (R-Y-B) with Fuse - 01 Nos (e) Cable glands for all incoming and outgoing cables
M&L Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth of not less than 2.25m below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of size 32 x 6 mm as earth lead by means of brazing etc all as shown in electrical plate No 3 connected to earthing test point as specified or indicated including testing on completion. Note:- (1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. 3) All the joints should be brazed only brass nuts/ bolts/ washers can be used in the test point complete all as specified and as directed ..
M & L for Point wiring with 1.5 Sqmm copper conductor unsheathed, multistranded, PVC insulated, single core cable FRLS with earth continuity conductor of 1.5 sqmm PVC insulated copper conductor and including rigid PVC conduit of suitable size but not less than 20mm dia. and all accessories fixed to be concealed in wall & surface of the roof etc. all as specified and as directed. Note:(Flush box,cover plate shall be measured seperately)
(a) One light point controlled by one switch
(b) One ceiling / Exhaust fan / Wall Fan point controlled by one switch
(d) One three/five pin socket 5 Amps plug point on independent board
All as per Ser item No-111 above but with 2.5 sqmm copper cable in and including PVC conduit complete all as specified and as directed for 15A socket.
S&F of Modular Switch type 1 way, 6A, 230 Volts AC complete all as specified.
S&F of Modular Switch type 1 way,16A, 230 Volts AC complete all as specified.
S&F of Modular Socket outlet 6A inlet multi socket for all pin 230 volt AC complete all as specified.
S&F of Modular Socket outlet 6/16A inlet multi socket for all pin 230 volt AC complete all as specified.
S&F 3 module PVC flush box for fixing of modular switches /sockets etc complete all as specified and directed
S&F 4 module PVC flush box for fixing of modular switches /sockets etc complete all as specified and directed
S&F 3 module white cover plate with frame complete all as specified and directed
S&F 4 module white cover plate with frame complete all as specified and directed
S&F surface mounting / wall mounted LED tube light fitting 1x20/18watts high efficiency, anti glare, maintenance free operation including LED driver and mounting arrangements, all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable white colour with suitable size complete all as specified and directed by Engineer-in-Charge.
S & F MCB protected modular socket (Modular AC Box) 25Amp, heavy duty 230 V AC complete all as specified and directed by Engineer-in-charge.
S&F MCCB 4 pole 63Amps, 16KA breaking capacity, 415Volts 3-phase supply complete all as specified and directed.
S&F of MCCB DB 4 way triple pole vertical type 415 volts 50 Hz AC supply including suitable provision for 4 pole MCCB incomer, fixed to the existing wall (concealed) and making good the disturbed surface wall with the exsting wall finish complete all as specified and as directed. Note : MCCB shall be measured seperately
Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured confirming to relevant IS specifcations with aluminum conductor of size 25 sqmm 4 core laid in trenches fixed on walls/ floors/ceiling etc all as specified and directed by Engr-in-Charge
M&L for Sub Main wiring with FRLS two runs of 6 sqmm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable size with all necessary fittings, surface in walls/roof/floor duly earthed with one run of FRLS single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge. Note:-(i) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate. (ii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. (iii) Three runs of cable and one run of PVC conduit / casing caping will be measured as one uint.
All as per item 129 above but Wiring for circuit /submain wiring alongwith earth wire with fthe following sizes through and incl steel conduit :-
(a) 2x 2.5sqmm FRLS wire 1x 1.5 Sqmm with earth FRLS wire
(a) 2x 2.4sqmm FRLS wire 1x 2.5 Sqmm with earth FRLS wire
Boring of holes under road, pavement hard standing by using trenchless technology using ultrasound technique and necessary machine to insert pipe of 50 to 100mm light grade GI pipes as per site requirement with all fittings such as bends, elbows, Tees, etc, for protection of cable complete including all plant & machinaries, alongwih Butt fusion welding machine with all accessories, T&P etc required all as specified and as directed. Note :- Protection pipe will be measured and paid separately
S&F ceiling fans complete with electronic type regulator and accessories 230 volt 1200mm sweep BEE 5 star Make : Crompton/Havells/Usha
S&F LED street light fitting 36 watt LED pressure die cast aluminium housing heat ressistant toughened glass with frame, IP-66 protection, uniform distribution suitable for 40mm outer dia GI pipe and connecting up etc complete with 3 core 1.5sqmm PVC insulated sheathed copper wire ISI marked, stranded, complete all as specified and as directed Make : Luker LST36 or equivallent Note : GI brackets will be measured /paid seperetly
S & F GI pipe light grade bracket 40 mm dia, 1.2 mtr long bent to shape as required and fixed with suitable size of MS clamps, (40 mm x 5 mm MS Flat) nut, bolt, washers etc to poles/walls complete all as directed.
M&L for light grade galvanized pipe ISI marked with all fitting ISI marked, laid in trenches, under road or fixing on wall/pole/ crossing nallah etc of bore 80 mm complete all as specified and as directed .
Supply and install hi wall split units Inverter type with copper coil/condenser indoor/outdoor units complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of 1.5 TR capacity complete all as specifed and as directed. (For Runway controller hut 28L)
Supply and install hi wall split units Inverter type with copper coil/condenser indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of 2.0 TR capacity complete all as specifed and as directed. (For ATCO restroom (Qty-01), ACCR room (Qty-02), FCC (Qty-1))
S&F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specifed and as directed.
S &F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specifed and as directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A complete all as specified and directed.
S & F refrigent pipes for suction and discharge lines for connection of indoor to outdoor units of 1.5 ton split AC of stranded size as per OEM recommendation with proper insulation including fixing arrangement with powder coated MS clamps and jointing of pipe etc., complete all as specified and as directed.
All as per item No. 143 above but 2.0 Ton Split AC all as directed.
S&F modular type motor starter, 25 Amps for split type air conditioners 1.5/2.0 Ton including cover plate and PVC surface box of suitable type complete all as specified and directed.
M&L for rigid PVC conduit (medium grade) size 25 mm dia including fittings such as elbow, bend & tee etc. for water drain out line for AC, laid on walls/floors with clamping/fixing materials complete all as specified and directed.
All as per item No.146 above but 40mm dia all as directed.
M&L PVC Pipe 20 mm dia heavy duty for in walls / roofs Condensing water line including making provision for fixing complete all as specified and as directed.
M&L for Point wiring complete with 1.5 sqmm single core FRLS grade 1100 V PVC insulated unsheathed wire with multi stranded copper conductor drawn through and including stove enamelled steel conduit concealed in wall and including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS ISI marked as earth continuity conductor etc, complete all as specified for:-
(a) One exhuast fan /light pointcontrolled by one switch
S & F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250 V complete all as directed
S& F exhaust fan flame proof, AC single phase, 230/240 V of size 380 (15'') mm sweep with louvers 1440 RPM including making necessary opening on stone /brick masonry wall and making good with matching colour with the surroundings all as directed.
M&L for Point wiring complete with 2.5 sqmm single core FRLS grade 1100 V PVC insulated unsheathed wire with multi stranded copper conductor drawn through and including stove enamelled steel conduit and conduit accessories ISI marked fixed on wall / ceiling/ roof etc and including provision of 2.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS ISI marked as earth continuity conductor etc, complete all as specified for 6 pin 15 Amp sockets outlet controlled by 15 Amp switch
S&F Flame proof switch socket &plug combined in LM6 cable termination box in LM6 16A 250 V 2 P+ earth complete all as specified and directed.
S&F LED light fitting 1x16W flame proof CMRI certified recommended for gas/vapor group of Iia & IIIB zone 1 & 2 and IP 65 protection with die cast aluminium hosing with heat resistant toughened glass with LED tube light fixture driver holder connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all as specified and directed..
M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to 25x4 mm GI iron strip earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 32mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed after taking down old earthing. Note: (i) Cost of copper strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning filling , removing , PCC chamber pit, RCC cover, test point etc.
S&F LED Street light fitting 1 x 45-48 Watt LED pressure die cast aluminum housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution suitable for 40 mm outer dia GI pipe and connecting up etc complete with 3 core 1.5 Sq mm PVC insulated sheathed copper wire ISI marked, stranded, complete all as specified and as directed. Make:-Crompton Cat Part No:- LSTP-45-CDL/Havells Cat Part No:- ENDURACITYLINERNEXGENSL45WLED757SASYBOPC/Luker Cat Part No LSTE-50 or equvalent.
Supply, installation, testing and commissioning of LT Feeder Pillar box cubical type (CPRI Approved) out door type, mounted on pedestal, suitable for accommodating the following accessories totally enclosed self supporting structure/cubicle, fully compartmentalized type, weather proof, protection IP-54, suitable for outdoor use, with bottom cable entry with suitable cable glands, made out of 3.15 mm thick CRCA steel sheets (IS 5039) with mounting on pedestal type foundation ,arrangement for bus bars, Voltmeter, Ammeter, indicator lamps and MCCB s, with sloping canopy at top, one Nos. of double hinged door at front, with suitable locking arrangement; Provision of louvers at sides, structure treated under 8-Tank metal treatment process and duly painted with powder coated paint of approved shade . The box shall be suitable for 415 Volts,50 HZ, 3 Phase, 4 Wire system complete with suitablesize of PVC copper conductor,thimbles,glands etc all as specified and directed by Engineer in Charge (a) 04 Nos. aluminium bus bar,150 Amps, with porcelain base and brass screws for mounting.(1.5 times the incoming switchgear current rating) (b) Incoming : MCCB, 4 pole, 63 Amps, 415 Volts, 16 KA, with adjustable setting, – 01(One) No. (c) Outgoing : MCCB, 4 Pole, 40 Amps, 415 Volts, 10 KA, with adjustable setting, – 02( Two) Nos. (d) LED Type Indicating Lamp (R-Y-B) with Fuse - 01 Nos (e) Cable glands for all incoming and outgoing cables
M/s D.Krishna Varma
sri ram construction
S J REDDY
M/S NAVEEN BUILDERS
Rajesh Engineering Consultants
GUTHIKONDA BROTHERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .