Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H1₹3.1 LAdmitted-Finance 135 139 BILAKHIA HOUSE MUKTANANAD MARG CHALA VALSAD GUJARAT 396191 | VALSAD | GUJARAT | 396191 | ₹3.1 L | H1 | Admitted-Finance |
| 2 | Rejected-Technical | - | - | Rejected-Technical Reject |
| 3 | Rejected-Technical | - | - | Rejected-Technical Reject |
| Sl No | Description | Qty | Unit | Meril Healthcare Private Limited H1 |
|---|---|---|---|---|
| 1.00REVISION UNCEMENTED THR SET | ||||
| 1.01 | a. FEMORAL STEM The Femoral Stem Should be Wagner type pourous coated collarless Long stem up to 300mm length, Stem material should be forged Ti6Al4V (TITANIUM)
b. ACETABULAR CUP Acetabular shell should be pourous coated with more then three independent locking meachanism with special designed for protrusio,cup material should be Forged Ti6AI4V(TITANIUM),Cup sizes Should be 44 to 64 mm (2 mm increment) sizes
c. POLYETHYLENE LINER The liner should be XLPE ( HIGHLY CROSS LINK POLYETHYLENE ),option of neutral/10 degree hooded liner,Liner sizes should be from 44-64mm / compatible to accommodate 28mm,32mm,36mm head.
d. FEMORAL METAL HEAD Femoral metal head material should be CoCr Alloy,Head sizes should be 28,32 & 36 mm with all neck length options
e. BONE SCREW Bone Screw material should be made of Ti6Al4V (TITANIUM),self tapping design and all sizes of 20,25,30,35,40 mm length,
] | 1 | Each | 1,09,500 ₹1,14,976 Lowest |
| 2.00EXTRA ITEMS FOR REVISION THR (Titanium) | ||||
| 2.01 | Acetabular mesh various size | 1 | Each | 5,000 ₹5,250 Lowest |
| 2.02 | Reinforcement ring various size | 1 | Each | 7,000 ₹7,350 Lowest |
| 2.03 | Protrusio cage various size | 1 | Each | 13,000 ₹13,650 Lowest |
| 2.04 | Circlage cables various size | 1 | Each | 7,500 ₹7,876 Lowest |
| 2.05 | Acetabular augments various size | 1 | Each | 22,000 ₹23,100 Lowest |
| 3.00Note -all above 1to 6 should be same make and L1 will be sum of all 1 to 6 components PRIMARY & COMPLEX TKR( PS) | ||||
| 3.01 | a. FEMORAL COMPONENT Femoral component should made of CoCr and have PS mechanism and availaible in all sizes
b. TIBIAL COMPONENT tibial component should be made of CoCr and availaible in all sizes and should be compatible with extension rod
c. LINER polyethylene liner component should be made of UHMWPE, polyethylene insert should have various thickness sizes.
d. PATELLA it should be made of UHMWPE and have different sizes
e. BONE CEMENT must have two units of 40 gm. Bone cement | 1 | Each | 47,782 ₹50,172 Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
19 May 2026, 4:00 pmClosed
Superintendent, SRG Hospital, Jhalawar
Superintendent, SRG Hospital, Jhalawar
Rate Contract for Revision THR and TKR Orthopeadic Department at SRG Hospital Jhalawar
2026_JMCSR_557437_2
NIT No. Acctt/2026/431_SRG Hospital_Jhalawar
Open Tender
Miscellaneous Goods
Item Rate
730 days
Jhalawar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Superintendent, SRP Hospital, Jhalawar/MD RISL
₹1 L
Yes
5 Aug 2026
8 May 2026
20 May 2026
8 May 2026
19 May 2026
8 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1REVISION UNCEMENTED THR SET | |||||
| 1.01 | a. FEMORAL STEM The Femoral Stem Should be Wagner type pourous coated collarless Long stem up to 300mm length, Stem material should be forged Ti6Al4V (TITANIUM)
b. ACETABULAR CUP Acetabular shell should be pourous coated with more then three independent locking meachanism with special designed for protrusio,cup material should be Forged Ti6AI4V(TITANIUM),Cup sizes Should be 44 to 64 mm (2 mm increment) sizes
c. POLYETHYLENE LINER The liner should be XLPE ( HIGHLY CROSS LINK POLYETHYLENE ),option of neutral/10 degree hooded liner,Liner sizes should be from 44-64mm / compatible to accommodate 28mm,32mm,36mm head.
d. FEMORAL METAL HEAD Femoral metal head material should be CoCr Alloy,Head sizes should be 28,32 & 36 mm with all neck length options
e. BONE SCREW Bone Screw material should be made of Ti6Al4V (TITANIUM),self tapping design and all sizes of 20,25,30,35,40 mm length,
] | - | Each | - | - |
| 2EXTRA ITEMS FOR REVISION THR (Titanium) | |||||
| 2.01 | Acetabular mesh various size | - | Each | - | - |
| 2.02 | Reinforcement ring various size | - | Each | - | - |
| 2.03 | Protrusio cage various size | - | Each | - | - |
| 2.04 | Circlage cables various size | - | Each | - | - |
| 2.05 | Acetabular augments various size | - | Each | - | - |
| 3.01 | a. FEMORAL COMPONENT Femoral component should made of CoCr and have PS mechanism and availaible in all sizes
b. TIBIAL COMPONENT tibial component should be made of CoCr and availaible in all sizes and should be compatible with extension rod
c. LINER polyethylene liner component should be made of UHMWPE, polyethylene insert should have various thickness sizes.
d. PATELLA it should be made of UHMWPE and have different sizes
e. BONE CEMENT must have two units of 40 gm. Bone cement | - | Each | - | - |
| 4EXTRA ITEMS | |||||
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
TechnicalBIDRevisionTHRTKR.pdf
Tender Documents • 3.76 MB
BOQ_992440.xls
BOQ • 0.29 MB
CorrigendDateextedTechnical.pdf
PDF • 1.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .