GE (N) BIKANER
GE (N) BIKANER Rajasthan-334001
REPAIR TO PATHWAY HARDSTANDING, FENCING AND REPAIR /REPLACEMENT EXISTING SEWAGE LINE, SEPTIC TANK, SOAKAGE WELL AND REPAIR TO TOILETS AT MFFR UNDER GE N BIKANER
2023_MES_613474_1
GE (N) BKN-TOKEN/48/2023-24
Open Tender
Miscellaneous Works
Item Rate
335 days
GE (N) BIKANER
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE North Bikaner
₹99,960
Yes
17 Jan 2024
12 Aug 2023
18 Sept 2023
12 Aug 2023
11 Sept 2023
28 Aug 2023
Amount
Dismantling posts or struts (RCC or steel) any section , including taking out embedded portion and making good disturbed ground complete all as specified and as directed by Engr-In-Charge.
Dismantling fencing wire , any type complete all as specified and as directed by Engr-In-Charge.
Excavating in post holes (or similar holes) in loose/soft soil each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm ,watering and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and as directed by Engr-In-Charge.
M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors complete all as specified and as directed by Engr-In-Charge.
M&L for Mild steel work for posts & struts in fencing including cutting top to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete all as specified and as directed by Engr-In-Charge.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and as directed by Engr-In-Charge.
Supply only chain link mild steel galvanized fencing, any type or size complete all as specified and as directed by Engr-In-Charge.
S&F Mild steel bars 10mm dia & over, cut to length, bent to shape requred, including cranking, bending spirally for hooping for columns, hooking ends and binding with and inc mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engr-In-Charge.
M&L for Preparing new or previously untreated steel & iron surfaces of any description over 10cm in width or girth and applying two coats of enamel paint over & including a coat of aluminium red oxide primer complete.
S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm to 80mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc as directed complete.
S& F Framed work as in Decorative doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
Demolition of brickwork built in cement or cement lime mortar complete all as specified and as directed by Engr-In-Charge.
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) complete.
Taking down cement plaster/terrazo finish on brick or stone walll etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed
M&L for Brick work with fly ash bricks old size straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and as directed by Engr-In-Charge.
M&L for 15mm thick Rendering in cement mortar 1: 4 on fair faces of brick work or concrete surfaces, finished fair and even complete.
M&L for Preparing new plastered or unplastered surfaces of walls and applying two coats of cement base paint white or tinted complete all as specified and as directed by Engr-In-Charge.
Complete removal of existing treatment on wall and preparing the surface applying two coats of cement base paint all as specified and directed.
Preparing old decorated surface plastered or unplastered by brooming down etc. and applying one coat of cement base paint on wall including cornices pilasters etc.
M&L for 75 mm thick pcc (1:4:8) type D -2 using 40 mm graded stone agg as in sub base laid in altennate bays finished even and rough complete all as specified and as directed by Engr-In-Charge.
Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade using grey cement and colour pigment complete.
Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade using grey cement and colour pigment complete.
M & L Chequered cement concrete tiles 20cm x 20cm x 25mm thick/ 30cm x 30cm x 25mm set, jointed and pointed in neat cement slurry in floors with 15mm thick screed bed in CM 1:6 complete all as specified and as directed by Engr-In-Charge.
S & F 38 mm Plastic dividing strips, 1.5mm thick complete all as specified and as directed by Engr-In-Charge.
M&L for bricks, sub class B, laid flat, Bedded and Add if, dry and jointed in jointed mortar pointed in and pointed are 1:3 cement in cement used in floors, old size brick complete all as specified and as directed by Engr-In-Charge.
M&L for 25mm thick sand cushoning under inter locking tiles including spreading and levelling complete.
M&L for broken stone Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engr-In-Charge.
M&L for 75mm thick Cement concrete 1:2:4 type B-2 using 40mm graded stone aggregate in ]\ floors and paving, laid in panels and finished even & smoth without using extra cement complete.
M&L for 40 mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate in ]\ floors and paving, laid in panels and finished even & smoth without using extra cement complete.
M&L for Cement concrete 1:2:4 type B-2 using 40mm graded stone aggregate in surface channels and drains complete.
S & Laying Reinforced concrete pipes, class NP3 pipe boreof pipe 300mm, laid and jointed complete with collars complete all as specified and as directed by Engr-In-Charge.
S & F Roof tiles, Mangalore pattern, interlocking in Roofing at side joints complete all as specified and as directed by Engr-In-Charge.
Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets and metal frame work and reinforced with G.I. wire mesh (including Fillets metal frame work and G.I. wire mesh GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screw at 450mm centre to centre /intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and 45mm suspended from sofit at approx 900mm centre to centre with GI cleat and steel expension fasterners with and including ceiling section (not exc 1.2 m length ) of 0.55mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre.
M& L Terrazzo tiles 20cm x 20 cm x 20mm thick, with grey cement no pigment with size of chips upto 6 mm; set jointed and pointed in neat cement slurry in floors, laid over 15 screed 1:6 cement mortar and cut and polishe as specified
M & L Non - skid Ceramic tiles 10 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors for garden / porch area etc. set and jointed in neat cement slurry under 15 mm screed 1:6 mortor and pointed in white or coloured cement to matc
M&L for Cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in coping or roof kerbs, rounded or chamfered on edges including necessary form work complete.
M&L for pre cast RCC jali 35mm thick in PCC (1:2:4) type B0 using 12.5mm graded stone aggregate set and jointed in CM 1:6. complete all as specified and as directed by Engr-In-Charge.
Providing precast cement concrete 1:2:4 B1 in window or door cills, lintels, bressumers, steps, quoin blocks (for use with ma sonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including cham fers, weatherings, throating etc. and setting in mortar complete with joints to match complete all as specified and as directed by Engr-In-Charge.
M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
Cleaning/removing blockage of sewer line (SGSW/RCC/CI) of dia 100/150/200/300mm etc of any description or in any position by roding, by pressure pump of any type or by using any mechanical equipments, manually or by puncher of sewage`line and repair the same if required including taking off and refixing manhole covers including removing all sludge in or outside MOD land complete all as specified and directed by Engr-in-Charge.
De-watering from septic tanks/soakage wells by suitable pumps and also removing of all wastes, semi solid or liquid of any description to the location as specified and directed by Engr-in Charge. (note: dewatering tank will be taken outside the defence land for disposal)
Cleaning/removing blockage of EWC, IWC, Gully Trap, including P or S Traps of any description, by rodding, by pressure pumps of any description or by other mechanical equipments in any position or locations at Military stn MFFR and nodes under AGE MFFR area till complete satisfaction within 48 hr of complaint of Engr-in-Charge.
Cleaning/removing blockage of floor trap, nahni trap, wash basins, sinks etc including waste pipe or waist coupling etc. by manually or mechanically at locations at Military stn MFFR and nodes under AGE MFFR area till complete satisfaction within 48 hr of complaint of Engr-in-Charge.
De-sludging by removing of semi solid sludge from existing septic tanks of any depth, any capacity in foul condition, including taking and placing in position the manhole cover of any description, removal of sludge & solid content to any place outside defence land and deposting where directed by Engineer-in-Charge.
De-sludging the existing / cleaning of man holes of depth not exceeding 2 mtrs of any size by removing silt/grit/sludge and faul water either by mannual or by mechanical means and flushing water through man holes to ensure free flow of sewage, placing back the man holes covers in position including removal all the sludge/silt/any foreign material from the sewer lines out the defence land complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m deep in foundations or for walls of manholes etc not exc 10 sqm on plan and not exceeding 1.5 m in depth and getting out complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5wide and exceeding 1.5 m not exc 3 m deep in foundations or for walls of manholes etc not exc 10 sqm on plan and not exceeding 1.5 m in depth and getting out complete all as specified and directed by Engineer-in-Charge.
Excavating over area n exc 1.5 mtr deep and getting out in soft loose soil complete all as specified and as directed by Engr-In-Charge.
Excavating over area exc 1.5 mtr deep to 3.0 and getting out in soft loose soil complete all as specified and as directed by Engr-In-Charge.
Returning, filling in, soft/loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing surplus soil obtained from item Nos 8 & 9 here-in-before to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed by Engineer-in-Charge
Demolition of cement concrete hunching without bedding layer to drain pipes including drain pipes dia 150 mm etc complete against the side of the pipe &removing all retrieved material all as directed by Engr-in-Charge.
Cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in packing under and hunching against the sides of pipes, without bedding layer, after they are laid and tested in 150 mm dia of pipe complete all as specified
S&F for Salt glazed stone were drain pipes, grade ‘A’ 150 mm bore (internal dia) laid in trenches over existing concrete bedding and jointed as specified
S& F Sail-glazed stoneware drain pipes laid in trenches and jointed bend and traps any radius 150 mm complete all as specified and as directed by Engr-In-Charge.
S& F Sail-glazed stoneware Gully Traps type P laid in trenches and jointed bend and traps any radius 180mm x100 mm complete all as specified and as directed by Engr-In-Charge.
S& F Intercepting traps of salt-glazed stoneware, with square ends to inspection arms for building flush into manholes and setting in cement mortar 1:1 complete, including concrete foundation of width and thickness as for pipes of same dia and haunching after setting. Cleaning arm to include a glazed ware stopper, galvanised iron bayonet joint (or other approved pattern) and galvanised iron lever (or trigger), galvanised iron chain, hook and ring complete all as specified and as directed by Engr-In-Charge.
S& F Cutting salt-glazed 150 mm stoneware drain pipe in position, including jointing socket end of new pipe to same with packed spun yarn and cement mortar 1:1 complete all as specified and as directed by Engr-In-Charge.
M&L for Brickwork with sewer bricks straight or curved on plan exc 6 m mean radius for man-holes/ septictank/ soakwell etc. in sewer works in curved work on plan with meaCM 1:4 complete all as specified and as directed by Engr-In-Charge.
Ditto all as per serial item No. 59 here-in-before but using old bricks and directed by Engineer-in-Charge.
M & L For Brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in cement mortor 1: 4 complete all as specified and as directed by Engr-In-Charge.
Supply only liquid water proofing compound ISI marked.
M&L for P.C.C (1:2:4) type B-2 using 40 mm graded stone aggregate as in surface channels and drains etc inside the manholes complete all as specified and directed by Engineer-in-Charge.
M&L for Cement concrete type E-2 1:5:10 using 40 mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and as directed by Engr-In-Charge.
Demoliton of stone slab as in roofs , suspended floors any thickness jointed in any mortar complete all as specified and as directed by Engineer-in-Charge.
S &F Jodhpur stone of roof slab self faced ,7.5cm to 10 cm thick ,25 cm to 35cm wide ,hoisted and set ,jointed and grouted in cement and sand mortar (1:6) complete all as specified
50mm thick P.C.C 1:3:6 C2 using 40 mm graded stone agg. As in floors over stone patti roof slab finished the surface even and fair complete all as specified and as directed by Engineer-in-Charge.
Cutting into existing manholes or connecting new, drains making good existing benching or forming channel and reforming benching with cement and sand mortar 1:4 or PCC 1:2:4 type B-1 smooth finished and reforming benching as in 150 mm dia of pipe complete all as specified and as directed by Engineer-in-Charge
S&F in replacement Vitreous china squatting pan of orissa pattern, white of size 580x440mm with integral foot rest and P or S trap in cluding provision of lime concrete bedding min 150mm thick (1:2:5) inc taking out old WC complete.
S&F in repair Wash down water closet (Pedestal pattern), complete with PVC (SWR) 'P' trap 110mm dia including jointing with cement mortar to existing CI pipe line complete all as specified and as directed by Engineer- in - Charge.
Supply & fixing repairs plastic water closet seat cover,white/ colour pattern with flat bottom and cover and mild steel chromium plated or aluminum hinging device.
Pre cast reinforced cement concrete 1: 2 :4 using 20 mm graded stone aggregates Medium Duty MD-10 Rectangular / Circular min cement content is 360kg/cum as with poper compaction vibrotor with lifiting hooks in manhole covers including removing old damaged cover from manhole complete all as specified and as directed by Engineer-in-Charge
M&L for Mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete.
Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in copings etc. including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete.
S&F in repairs PVC (SWR) bends any radius, 110 mm bore complete.
S&F in repairs PVC (SWR) bends any radius, 75 mm bore complete.
S&F in repairs PVC (SWR) junction single, (single T) equal or unequal any radius, 110 mm bore complete.
S&F in repairs PVC (SWR) junction single, (single T) equal or unequal any radius, 75 mm bore complete.
Supply & fixing in repairs PVC (SWR) pipes 110 mm dia single socket in any length with rubber ring joints fixed to walls including MS clamps etc incl taking down unservicable pipe complete.
Supply & fixing in repairs PVC (SWR) pipes 75 mm dia single socket in any length with rubber ring joints fixed to walls including MS clamps etc incl taking down unservicable pipe complete.
S&F in repairs PVC (SWR) reducers 75-110 mm dia complete all as specified and as directed by Engr-In-Charge.
S&F in Brass chromium plated trap ‘P’ or ‘S’ pattern for 40 mm wash basins and sinks with inlet and outlet, screwed for pipe or connections, and with one cleaning cap and fixed complete all as specified and as directed by Engr-In-Charge.
S&F in Brass chromium plated bottle traps 40 mm for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and as directed by Engr-In-Charge.
S&F in repairs Stack clamps out of 50mm x 3mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, for 100mm bore pipes complete all as specified and as directed by Engr-In-Charge.
M/s JUGAL KISHORE MISHRA AND SONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .