Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.7 L+₹1.5 L (6.32%)Rejected-Finance | L2 | Rejected-Finance Reject being not L1 | |
| 3 | L3₹24.8 L+₹1.5 L (6.62%)Rejected-Finance NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | L3 | Rejected-Finance Reject being not L1 | |
| 4 | L4₹25.4 L+₹2.2 L (9.62%)Rejected-Finance | L4 | Rejected-Finance Reject being not L1 | |
| 5 | L5₹26.5 L+₹3.3 L (14.4%)Rejected-Finance 1273 CUTINO ROAD KARWAR 581301 | KARWAR | UTTARA KANNADA | KARNATAKA | 581301 | L5 | Rejected-Finance Reject being not L1 |
Tender Value
Refer Docs
EMD Value
₹68,000
Closing Date
18 Nov 2021, 6:00 pmClosed
GE(SB) Karwar
GE (Seabird) Karwar Naval Base Karwar
REPAIR, MAINTENANCE OF INTERNAL ELECTRIFICATION, FITTINGS, FIXTURES INCL EARTHING AT SAILORS MD ACCN OF KADAMBA VANAM INCL MAP QTRS AT NAVAL BASE KARWAR UNDER GE(SB) KARWAR
2021_MES_484709_1
8855/E8
Open Tender
Civil Works
Item Rate
330 days
GE (Seabird) Karwar Naval Base Karwar
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE(Seabird) Karwar
₹68,000
Yes
5 Feb 2022
28 Oct 2021
25 Nov 2021
28 Oct 2021
18 Nov 2021
11 Nov 2021
Amount
Rectifying the defects in domestic fluroscent tube/CFL light fittings any type and at any height, ceiling rose, electric bell by tightening loose connections and rectifying defects, testing complete all as specified and directed.
Opening switch mounting plate at normal height upto 1.5 m, rectifying the defects in fittings and fixtures such as switches, bell push, fan regulator, sockets etc by tightening loose connections, refixing switch plate and testing complete all as directed. Note for Item No 1.00 & 2.00 :- The unit rate quoted shall be deemed to include the elements of labour only for rectifying and making the fitting and fixtures functional. If replacement of parts/items is required to make the fittings functional, the cost for labour and material for the same will be measured and paid for as "S & F in repairs" under relevant items of this schedule hereinafter and in such cases the above items will not be measured and paid for.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M & L for surface point wiring 1100 Volts grade 1.5 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC casing & caping medium grade with all accessories in wall/ceiling /floor/roof etc, sunk pressed steel or cast iron terminal boxes with 3 mm thick plastic laminated sheet top cover including 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as continuous earth wire connected to common earth dolly all as specified and directed for the following:-
(a) One light/fan point controlled by one switch
(b) One 3 pin socket outlet 5 Amp on same board with other switches.
(c) One 3 pin socket outlet 5 Amp on independent board.
(d) One bell point controlled by one push button on the same board with other switches or independent with cables of 1.5 Sqmm size.
Description all as per item No. 4.00 above but with cables 2.5 Sqmm for one 3 pin socket outlet 15 Amps on independent board
Description all as per item No. 4.00 above but with cables 4.0 Sqmm for one 3 pin socket outlet 15 Amps on independent board
M & L for point wiring with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable drawn in existing conduit and making good disturbed surfaces to match with the existing surface complete all as specified and directed by Engr-in-Charge.
(a) One light/fan point controlled by one switch
(b) One 3 pin socket outlet 5 Amp on same board with other switches.
(c) One 3 pin socket outlet 5 Amp on independent board.
(d) One bell point controlled by one push button on the same board with other switches or independent with cables of 1.5 Sqmm size.
Description all as per item No. 7.00 above but with cables 2.5 Sqmm for one 3 pin socket outlet 15 Amps on independent board.
Description all as per item No. 7.00 above but with cables 4.0 Sqmm for one 3 pin socket outlet 15 Amps on independent board.
Taking down submain wiring cable of any size/type alongwith earth wire with or without concealed/surface conduit/casing caping complete all as specified and directed.
M & L for sub main wiring with proper colour coding, FRLS PVC insulated copper conductor, unsheated, multi-stranded cable of two runs, 6 Sqmm for phase and neutral and one run of 6 Sqmm for earth wire, drawn through and including PVC casing and caping with all fittings like tee, bends, junction box/terminal box fixed on wall/ground/ceiling etc and connected complete all as specified and directed by Engr-in-Charge. NOTE - Phase should be of Red/Yellow/Blue, neutral should be of black and earthing wire should be of green colour. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length.
Description all as per item No 11.00 above but 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth wire.
M & L for sub main wiring with proper colour coding, FRLS PVC insulated copper conductor, unsheated, multi-stranded, copper conductor, cable of two runs, 6 Sqmm for phase and neutral and one run of 6 Sqmm for earth wire, drawn through existing conduit and junction box fixed in wall/ceiling etc and connected complete all as specified and directed by Engr-in-Charge. NOTE- Phase should be of Red/Yellow/Blue, neutral should be of black and earthing wire should be of green colour. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length.
Description all as per item No 13.00 above but 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth wire.
S & F in repairs MCB DB SPN, 12 way, 240 Volt, single door powder coated sheet steel enclosure for surface mounting fitted with 200 Amps bus bar and din channel complete all as specified and directed. MAKE : Havells/Indo Asian/Legrand or equivalent as approved by GE.
S & F in repairs MCB DB SPN, 8 way, 240 Volt, double door powder coated sheet steel enclosure for surface mounting fitted with 200 Amps bus bar and din channel complete all as specified and directed. MAKE : Havells/Indo Asian/Legrand or equivalent as approved by GE.
S & F in repairs MCB DB TPN, 4 way, 415 Volt, single door powder coated sheet steel enclosure for surface mounting fitted with 200 Amps bus bar and din channel complete all as specified and directed. MAKE : Havells/Indo Asian/Legrand or equivalent as approved by GE.
S & F in repairs MCB TPN, 6 to 32 Amps, ''C'' series 415 Volts, 3 phase, 10 KA breaking capacity of complete all as specified and directed. MAKE : Havells/Indo Asian/Legrand or equivalent as approved by GE.
S & F in repairs MCB TPN, 50 to 63 Amps, ''C'' series 415 Volts, 3 phase, 10 KA breaking capacity of complete all as specified and directed. MAKE : Havells/Indo Asian/Legrand or equivalent as approved by GE.
S & F in repairs MCB SPN, 6 to 32 Amps, ''C'' series 230 Volts, single phase, 10 KA breaking capacity complete all as specified and directed. MAKE : Havells/Indo Asian/Legrand or equivalent as approved by GE.
S & F in repairs MCB SP, 6 to 32 Amps, ''C'' series 230 Volts, single phase, 10 KA breaking capacity complete all as specified and directed. MAKE : Havells/Indo Asian/Legrand or equivalent as approved by GE.
S & F in repairs single pole and neutral enclosure with a two pin and earth plug and socket industrial type with one MCB 20 Amp double pole 240 Volts complete all as specified and directed.
S & F in repairs switch piano 5 Amps one way flush type complete all as specified and directed. MAKE : Havells/Anchor/Cona or equivalent as approved by GE.
S & F in repairs switch piano 5 Amps two way flush type, complete all as specified and directed. MAKE : Havells/Anchor/Cona or equivalent as approved by GE.
S & F in repairs socket outlet 2 in 1, 5 pin, 5 Amps flush type, complete all as specified and directed. MAKE : Havells/Anchor/Cona or equivalent as approved by GE.
S & F in repairs switch socket combination 5 Amps, 5 pin, flush type multi purpose complete all as specified and directed. MAKE : Havells/Anchor/Cona or equivalent as approved by GE.
S & F in repairs switch piano 15 Amps one way flush type complete all as specified and directed. MAKE : Havells/Anchor/Cona or equivalent as approved by GE.
S & F in repairs socket outlet 2 in 1, 3 pin, 5 and 15 Amps flush type complete all as specified and directed. MAKE : Havells/Anchor/Cona or equivalent as approved by GE.
S & F in repairs switch socket combination 2 in 1, 3 pin, 5 and 15 Amp, flush type universal complete all as specified and directed. MAKE : Havells/Anchor/Cona or equivalent as approved by GE.
S & F in repairs switch with indicator 25 Amps one way flush type complete all as specified and directed. MAKE : Havells/Anchor/Cona or equivalent as approved by GE.
S & F in repairs ceiling fan regulator electronic five step type 230 Volts single phase complete all as specified and directed. MAKE : Havells/Anchor/Cona or equivalent as approved by GE.
S & F in repairs bell push 5 Amps 230 volts AC, single pole complete all as specified and directed. MAKE : Havells/Anchor/Cona or equivalent as approved by GE.
S & F in repairs bell electric (ding dong bell) 230 volts AC, single phase complete all as specified and directed. MAKE : Havells/Anchor/Cona or equivalent as approved by GE.
S & F in repairs lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. MAKE : Havells/Anchor/Cona or equivalent as approved by GE.
S & F in repairs ceiling rose surface bakelite 65 x 50 mm three terminal on and including PVC junction box of suitable size complete all as specified and directed. MAKE : Havells/Anchor/Cona or equivalent as approved by GE.
S & F in repairs 5 W LED box type light fittings 1 Feet including making necessary connections complete all as specified and directed. MAKE : Havells/Bajaj/Philips/ Wipro/ C&S/ Shakti or equivalent as approved by GE.
S & F in repairs decorative wall light fixture made up of polycarbonate, suitable for 1 x 10 W LED lamp (B-22 base) with back plate complete all as specified and directed by Engr-in-Charge. MAKE : Havells, Cat Part No - LHFOFWE1TZ1W012 or equivalent in Bajaj/CG/Wipro/C&S as approved by GE.
S & F in repairs LED batten suitable for T8 LED retrofit tube 4' with LED tube rod 18 W, 230 Volts, complete with all connected accessories including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. MAKE : Havells/Bajaj/Philips/ Wipro/ C&S/ Shakti or equivalent as approved by GE.
S & F in repairs T8 LED tube rod 18/20 W, 4 feet length, 6000K complete with all accessories as specified and as directed. MAKE : Havells/Bajaj/Philips/Wipro/Shakti/C&S or equivalent as approved by GE.
S & F in repairs 10 watt LED box type light fittings 2 feet including making necessary connections complete all as specified and directed. MAKE : Havells/Philips/C&S/Bajaj/Shakti or equivalent as approved by GE.
S & F in repairs heavy duty vacuum pressure impregnated copper Ballast (VPIT) for fluroscent tube 28 watt complete all as specified and directed. MAKE : Bajaj/Havells/CG/Wipro/Shakti or equivalent as approved by GE.
S & F in repairs heavy duty vacuum pressure impregnated copper Ballast (VPIT) for fluroscent tube 14 watt complete all as specified and directed. MAKE : Bajaj/Havells/CG/Wipro/Shakti or equivalent as approved by GE.
S & F in repairs flourescent tube rod 4 feet 28 Watt complete all as specified and directed. MAKE : Bajaj/CG/Havells/Wipro/Shakti or equivalent as approved by GE.
S & F in repairs flourescent tube rod 2 feet 14 Watt complete all as specified and directed. MAKE : Bajaj/CG/Havells/Wipro/Shakti or equivalent as approved by GE.
Taking down ceiling fan/exhaust fan of any sweep, dismantling, replacing defective part, overhauling, cleaning, greasing, rewinding etc and hanging up/fixing back in the original position, connecting up and testing complete all as directed. NOTE : (a) The unit rate quoted shall deemed to be included of minor items viz nuts, bolts split pin and rubber wheel etc. (b) Capacitor & bearing shall be measured and paid for separately under respective items here-in-after. (c) Rewinding of fan shall be measured and paid for separately under respective items here-in-after.
S & F in repairs capacitor of 2.5 mfd for ceiling fan/exhaust fan complete all as specified and directed.
S & F in repairs bearing No 6201/6202/6203 suitable for ceiling fan/exhaust fan complete all as specified and directed. MAKE : SKF/NBC/TATA/FAG or equivalent as approved by GE.
M & L for removing burnt out copper winding wire from ceiling fan of any make and size of 1200 mm to 1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material, varnishing and drying complete all as specified and directed.
Description all as per item No 48.00 above but exhaust fan of 300 mm sweep.
Description all as per item No 48.00 above but exhaust fan of 450 mm sweep.
S & F in repairs heavy duty vacuum pressure impregnated copper Ballast (VPIT) for CFL lamp 9/10/11/13/18 watt 240 volt, low loss electro magnetic ballast all as specified and directed. MAKE : Bajaj/Havells/CG/ Wipro or equivalent as approved by GE.
S & F in repairs CFL lamp holder suitable for CFL light fitting 9/10/11/13/18 W all as specified and directed.
S & F in repairs CFL lamp 9/10/11/13/18 watt 230 Volt cross pin type complete all as specified and directed.
S & F in repair CFL lamp 2 pin type 9/11/15 W 230 Volts ISI marked all as specified and as directed.
Fixing only energy meter 230/415 volt, 10-25 Amp including making incoming and outgoing electric connection and testing including taking down old defective energy meter and depositing the same to MES store yard complete all as specified and directed. NOTE : Energy meter will be issued under Sch ‘B’ free for hanging/fixing only.
S & F in repairs ventilator fan AC single phase 230 V of size 200 mm (PVC body) with louvers shutter (white/Ivory) and connected with flexible cord of size 23/0/0076 stranded copper conductor PVC insulated of length not less than 0.7 m complete all as specified and directed. MAKE- Orient/Bajaj/Usha/CG/Havells or equivalent as approved by GE.
S & F in repairs exhaust fan AC single phase 230 V of size 300 mm, 1400 RPM (steel body) with louvers shutter grey colour and connected with flexible cord of size 23/0/0076 stranded copper conductor PVC insulated of length not less than 0.7 m complete all as specified and directed. MAKE - Orient/Bajaj/Usha/CG/Havells or equivalent as approved by GE. NOTE - Old unserviceable fan shall be deposited in MES store by the contractor and necessary RV shall be prepared and accounted for.
S & F in repairs exhaust fan AC single phase 230 V of size 450 mm, 1400 RPM (steel body) with louvers shutter grey colour and connected with flexible cord of size 23/0/0076 stranded copper conductor PVC insulated of length not less than 0.7 m complete all as specified and directed. MAKE - Orient/Bajaj/Usha/CG/Havells or equivalent as approved by GE. NOTE - Old unserviceable fan shall be deposited in MES store by the contractor and necessary RV shall be prepared and accounted for.
S & F in repairs ceiling fan AC single phase 230 V of size 1200 mm sweep with blade white/brown and connected with flexible cord of size 23/0/0076 stranded copper conductor PVC insulated of length not less than 0.7 m complete all as specified and directed. MAKE - Orient/Bajaj/Usha/CG/Havells or equivalent as approved by GE. NOTE - Old unserviceable fan shall be deposited in MES store by the contractor and necessary RV shall be prepared and accounted for.
S & F in repairs wall mounted fan AC single phase 230 V of size 400 mm sweep with blade white and connected with flexible copper cord of suitable size of length not less than 0.7 m complete all as specified and directed. MAKE - Orient/Bajaj/Usha/CG/Havells or equivalent as approved by GE. NOTE - Old unserviceable fan shall be deposited in MES store by the contractor and necessary RV shall be prepared and accounted for.
S & F in repairs heating element 1.5 KW of storage type water heaters (geyser) embedded type nickel plated duly mineral filled, ISI Marked complete all as specified and directed. MAKE : CG/ Bajaj/ Recold/ Havells or equivalent as approved by GE.
S & F in repairs heating element 2.0 KW of storage type water heaters (geyser) embedded type nickel plated duly mineral filled, ISI Marked complete all as specified and directed. MAKE : CG/ Bajaj/ Recold/ Havells or equivalent as approved by GE.
S & F in repairs thermostat adjustable between 30 degree C to 85 degree C for geyser complete all as specified and directed.
S & F in repairs PVC connection 15 mm dia 600 mm long (heavy duty) with 2 Nos PTMT nut and washer for cold water complete all as specified and directed.
S & F in repairs brass chrominum plated connection 15 mm dia 600 mm long (heavy duty) with 2 Nos brass chrominum plated nuts and washer for hot water complete all as specified and directed.
S & F in repairs PVC insulated and sheathed copper multistranded cable three core 2.5 sqmm, heavy duty and connected from plug top to geyser as per site requirement complete all as specified and directed by Engr-in-Charge.
M & L for earthing complete with galvanized cast iron earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level ) with top edge of earth plate not less than 1.5 m below normal ground level connected to galvanized earth lead 4 mm dia by means of bolts, nuts washers and check nuts of steel/GI duly protected with 15 mm bore light grade pipe upto main board, 20 mm bore watering pipe light grade with CI/MS funnel and wire mesh including excavation, earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 m, charcoal dust and common salt in adequate qty all as shown in electrical plate No 3 of SSR Part-I 2009 having pit and cover in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40 x 40 x 6 mm grouted in PCC pit for PCC cover, funnel with wire mesh complete and all as specified. Note :- The unit rate quoted shall be deemed to include for necessary excavation and earth work, PCC 1:3:6 type CI chamber, funnel with GI medium grade watering pipe 15 mm bore, RCC cover slabs 50 mm thick with 8 mm dia CTD bars @ 140 mm C/C both ways etc.
S & F in repairs LED Bulk Head 10 W with pressure plastic housing with clear prismatic diffuser, high efficient LEDs IP65 complete all as specified and directed. MAKE - Bajaj/ CG/Havells/Wipro/Halonix/C&S or equivalent as approved by GE.
Taking down carefully old defective/ unserviceable tube light/ down light/ mirror light/ gate light/ bulk head/ garden light/ building street of any size or type and fixing only LED light fittings of any type or size including making necessary connections complete all as specified and directed. NOTE: LED light fittings will be issued under Sch 'B' free for fixing only.
Taking down old defective/ unserviceable MCB SPN/ TPN of any size or type and fixing only MCB of any type or size including making necessary connections complete all as specified and directed. NOTE: MCBs will be issued under Sch 'B' free for fixing only.
M/S DK Enterprises
ANKIT SHIP REPAIRERS AND SUPPLIERS
BROTECH
M/S VERNEKAR AGENCIES
N P ENGINEERINGS
M/S KAMALKANTH NAIK
NAGESH BEERAPPA NAIK WORKS CONTRACTOR
OM SAI ELECTRICALS AND HARDWARES
Bidder Name
M/S KAMALKANTH NAIK
ANKIT SHIP REPAIRERS AND SUPPLIERS
M/S VERNEKAR AGENCIES
M/S DK Enterprises
SIRI SALES AND SERVICES
OM SAI ELECTRICALS AND HARDWARES
BROTECH
N P ENGINEERINGS
NAGESH BEERAPPA NAIK WORKS CONTRACTOR
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .