Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹70.3 L
EMD Value
₹1.4 L
Closing Date
16 Apr 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
45 days
Expenditure
Capital (Works)
Above/Below/Par
TENDER ELG
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.(In this connection scanned copy of Annexure VIB duly filled up must be attached with offer).
The tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender .Other terms and conditions shall follow of GCC, April 2022. Definition of Similar nature of work has given below (1.1)
Defination of Similar Work :- Definition of Similar nature of work :- As per CEE's letter No. EL/112/0/KM, dated 22.08.2013 : Item Sl. 2.2 under "LT Electrical Works" : Supply , erection, testing and commissioning of electrical wiring in residential quarters/Railway Stations/Service building/High bay Sheds etc. / Supply, erection, testing and commissioning of tubular poles/Octagonal poles and Luminaries including erection of rail poles in streets/yards, washing lines & circulating area with or without timer.
13 conditions · 4 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please submit a certificate in the prescribed format for verification / confirmation of the documents submitted for compliance of eligibility / qualifying criteria. Non submission of the certificate, or submission of certificate either not properly filled in, or in a format other than the prescribed format shall lead to summarily rejection of your offer.(Circular and format related with document verification certificate is attached in document section) & ( Annexure-VA certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc.
The following documents should be attached with the tender: (i)Scanned copy of Pan Card. (ii)Scanned Copy of EFTMANDATE FORM Duly filled up by the bidder(iii)Tender Document (duly digitally signed by the bidder)
Scanned copy of valid GST (Goods & Service Tax)Registration Certificate.
Scanned copy of valid Trade license or Propitorship Certificate.
List of the Works completed in the last three financial years giving description of work. Organization for whom executed, approximate value of contract at the time of award, date of award and date of scheduled completion of work. Date of actual start, actual completion and date of payment and final value of contract should also be given. (Supportive documents/ certificates from the organization with whom worked/are working should be enclosed) (Please attach scanned copy of Annexure-I duly filled up).
List of works in hand indicating Supportive documents/certificates from the organization with whom worked/are working should be enclosed) description of work, contract value, approximate value of balance work yet to be done and date of award. (Supportive documents/certificates form the organization with whom worked/are working should be enclosed).(Please attach scanned copy of Annexure-IV duly filled up)
Partnership deeds, power of Attorney etc. (if any) : The tender shall clearly specify whether the tender is submitted on his own or on behalf of a partnership concern. If the tender is submitted on behalf of partnership concern he should submit the certified copy of the partnership deed alongwith the tender authorisation to sign the documents on behalf of the partnership firm. If these documents are not enclosed alongwith the tender document, the tender will be treated as hearing lease submitted by the individual signing the tender documents. The Railway will not consider any power of Attorney granted by the tender or any changes in the composition of the firm made subsequent to the execution of the contract. It may however recognize such power of Attorney and change after obtaining proper legal advice, the cost of which will be chargeable to the contract.(Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder
Railway Officers Associated with tenderer:RAILWAY OFFICERS ASSOCIATED WITH TENDERER 1. ExRailway Officer as tenderer: Should tenderer be a retired Gazetted Officer working before his retirement on any of the Railways owned and administered by the President of India, or should the tenderer being partnership firm have as one of its partners a retired Gazetted Officer as aforesaid, or should the tenderer being an incorporated company have any such retired Officer as one of its Directors, or should the tenderer have in his employment any retired Gazetted Officer as aforesaid, full information of such person shall be submitted along with his tender in the format given in annexure-V to this chapter of this tender document. (Authority: ACS No.3 to GCC July,2014vide Boards letter No.2014/CEI/CT/O/9/RET dt.22.01.2015)(please attach scanned copy of Annexure-v duly filled up by the firm).
Option for receiving payment through Letter of Credit . (Please attach scanned copy of ANNEXURE 1 LC & ANNEXURE 2 LC duly filled up by the firm if opted for)
Submission of Documents in support of Eligibility Criteria : All documents in support of fulfillment of eligibility criteria with respect to completion of 'Similar Nature of work for technical Eligibility criteria 'and 'Total Contract value for Financial Eligibility Criteria' should be uploaded online in the website with scanned copy at the time of tender bidding with the details. No post - tender communication , in any form will be made or entertained , after opening of tenders in this regard .Railways may however call for the originals of the credentials for verification or any clarifications/Confirmations on the contents of the documents submitted .Eligibility of tenderers shall be decided solely on the basis of the documents submitted alongwith the tender offers and any subsequent document whatsoever submitted in this connection would not be given any cognizance on any account.
The Contractor/(firm) must go through the entire tender document along with all attachment for any kind of guidance regarding execution of the job & payment there after. In case any thing is left out or not clear then they should consult the General Condition of Contract & standard Specification as attached (uploaded ).The bidders are also advised to preserve a copy of entire tender document/ (Set) for their convenience.
1) Electrical (general) work in connection with "Provision of facilities in TTE rest room at Howrah at par with that of running rooms of guards / loco pilots". 2) Electrical (general) work in connection with "Proposal for provision of facilities at par with that running rooms of drivers / guards in three numbers of TTE Rest Rooms at HWH station (Both new and old complex) for staff running S.E.Rly trains".
EL-HWH-25-21-3429
EL-HWH-25-21-3429
Open
Works - General
180 Days
Howrah, West Bengal
₹0
₹1.4 L
16 Apr 2025
24 Mar 2025
187 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 22,19,580 | ||
| — | 32.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of Variable refrigerant flow (VRF) top Discharge Air cooled Type Outdoor units equipped with Full Inverter driven(100%)micro processor base panel highly efficient air conditioning system, comprising compressor DC inverter driven Scroll/Twin Rotary type with fully factory charged R-410A refrigerent gas & oil, running at 415V±10% - 3 Ph - 50 Hz heating mode with minimum COP 3.14 ( Heating Mode ) ultra low standby power consumption, EER values 3.01 ( Cooling Mode ) at AHRI Conditions (BMS compatible, Web monitoring option). All the units shall be provided with micro processor based control for sequential starting of condensing units, smart tools , advance refrigerant control , Liquid back flow protection, Intelligent Maintenance Tool, precise oil control technology, reverse phase operation, running at 415V±10% - 3 Ph - 50 Hz,condenser made with copper tubes DC fan motor, ODU should have electrical control box with an IP55-rated Design, various electrical protection like-phase sequence, high /low voltage protection , supersense, compressor overload protection,fan & compressor temparature protection & pressure protection . The Outdoor unit also having blue fins with 4 face heat exchanger & capable to run in 52 Deg C. Complete with individual remote controller and centralized controller with easy software programe upgradation for urgent maintanance. ODU having Heating and cooling operation with wide ambient heating -20°C to 26°C, Cooling -15°C to 52°C - 32 HP = 32 sets ( Here, 1 HP = 1 Set ) ( Make : O General / Fujitsu-General / Mitsubishi Electric / Panasonic / Samsung / Carrier / Toshiba / LG / Hitachi / Trane / Voltas ) | — | — | — | 8,13,376 | |
| — | 6.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of VRF 4 way swing louver Cassette type (Heating & Cooling System) Indoor unit , 230V / 1ph / 50 Hz, comprising of micro processor based panel with Inbuilt drain pump & cordless remote for sequential starting of blower fan / runner,DX copper coils, thermostat, pulse modulating electronic expansion valve, fins, capacities:- 4.0 TR (minimum cooling capacity 14KW, air flow not less than 1050 CFM, sound pressure level will be maximum 47 db. ( Make : O General / Fujitsu-General / Mitsubishi Electric / Panasonic / Samsung / Carrier / Toshiba / LG / Hitachi / Trane / Voltas ) | — | — | — | 3,93,024 | |
| — | 10.00 | — | — | ||
| Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with 34.93mm OD with 19mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units, all piping inside the room shall be properly supported with MS hanger. ( Make : Rajco / Mandev / Royku ) | — | — | — | 16,760 | |
| — | 22.00 | — | — | ||
| Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with 28.6mm OD with 19mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units, all piping inside the room shall be properly supported with MS hanger. ( Make : Rajco / Mandev / Royku ) | — | — | — | 18,370 | |
| — | 18.00 | — | — | ||
| Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with 22.2mm OD with 19mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units, all piping inside the room shall be properly supported with MS hanger. ( Make : Rajco / Mandev / Royku ) | — | — | — | 9,918 | |
| — | 30.00 | — | — | ||
| Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with 19.05mm OD with 13mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units, all piping inside the room shall be properly supported with MS hanger. ( Make : Rajco / Mandev / Royku ) | — | — | — | 19,530 | |
| — | 10.00 | — | — | ||
| Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with 15.8mm OD with 13mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units, all piping inside the room shall be properly supported with MS hanger. ( Make : Rajco / Mandev / Royku ) | — | — | — | 5,570 | |
| — | 10.00 | — | — | ||
| Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with 12.7mm OD with 13mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units, all piping inside the room shall be properly supported with MS hanger. ( Make : Rajco / Mandev / Royku ) | — | — | — | 3,470 | |
| — | 6.00 | — | — | ||
| Supply, Testing and Commissioning of Indoor Copper seperation Tube | — | — | — | 21,474 | |
| — | 40.00 | — | — | ||
| Supply, Testing, Commisioning, Trial run of the entire VRF system including nitrogen Flusing, charging of R 410A Refrigerant Gas for Topping UP including Pressure testing and Vacuumising etc., as per direction and satisfaction of the Railway Incharge. | — | — | — | 33,400 | |
| — | 25.00 | — | — | ||
| Supply of Rigid PVC Drain Piping of 32 mm dia complete with , fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation including Installation Testing and commissioning. | — | — | — | 2,975 | |
| — | 100.00 | — | — | ||
| Supply & fixing of control cum distribution wiring by Copper conductor cable of size 2C X 1.5 Sq. mm along with conduit for looping between indoor & outdoor VRF system and to main Central remote controller system. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | — | — | 12,700 | |
| — | 4.00 | — | — | ||
| Supply of Split Air Condiotioner unit Inverter type of cap 2 TR minimum BEE 5 star rated or above, rotary compressor type, both coils made of copper, having Eco-friendly type refrigerant, copper pipe of 3 Mtr suitable for operation on 1 Ph, 230V, 50Hz supply system with variable speed and warranty 1 year on the product, 5 years on component (including pcb) and 10 years on the compressor, including Standard installation kit and other accessories. ( Make : O General / Fujitsu-General / Mitsubishi Electric / Panasonic / Samsung / Carrier / Toshiba / LG / Hitachi / Trane / Voltas ) | — | — | — | 1,72,872 | |
| — | 4.00 | — | — | ||
| Installation, testing and commissioning of 2 TR Split AC machine including outdoor unit with MS angle stand including necessary power cable and all other accessories. | — | — | — | 9,368 | |
| — | 40.00 | — | — | ||
| Supply of Refrigerant Copper Pipe line of required size and length with nitrile rubber insulation and all other accessories including fixing, testing and commissioning of above pipe line for above split AC units | — | — | — | 27,680 | |
| — | 50.00 | — | — | ||
| Supply of Drainage system for each above Split & Window AC machine for discharge of condensate water with all accessories by 1.5 inch dia PVC pipe and drain line of each machine connected by 0.5 inch cotton braided PVC flexible pipe with all other accessories along with fitment and commissioning. | — | — | — | 5,250 | |
| — | 174.00 | — | — | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | — | — | 58,638 | |
| — | 25.00 | — | — | ||
| Wiring of 6A / 3 pin Plug board consisting with one plug socket and one 6A switch by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | — | — | 4,750 | |
| — | 10.00 | — | — | ||
| Wiring of 6/16A 3 pin Plug board consisting with one 16A plug socket and one 16A switch by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq. mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | — | — | 4,440 | |
| — | 45.00 | — | — | ||
| Wiring of Mobile Charging Plug Board point by 2 nos. single core, HRFR / FRLS grade PVC insulated copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with HRFR / FRLS grade copper ECC of size 1.5 sq.mm, 1100V grade and each PVC multi plug board consisting of 4 nos. 6A/3 pin plug socket, 4 nos. 6A switch and 1 no. 10A MCB ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | — | — | 17,955 | |
| — | 4.00 | — | — | ||
| Wiring of AC Machine ( Window / Split ) / Water Cooler point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) and each switch board comprising with one power unit which includes one double pole MCB, one single phase starter and one 6/16A 3 pin socket and plug with indicating light and all other associated work ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | — | — | 4,776 | |
| — | 400.00 | — | — | ||
| Wiring of Submain by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | — | — | 30,400 | |
| — | 150.00 | — | — | ||
| Wiring of Mainline by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 10 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | — | — | 38,250 | |
| — | 200.00 | — | — | ||
| Wiring of Mainline by 4 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 10 sq.mm, 1100V grade for 03 phases and 01 neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | — | — | 1,54,200 | |
| — | 258.00 | — | — | ||
| Extra cost for conceal wiring in respect to PVC conduit / casing for light, fan, plug, power plug, multi-plug point etc. including make good of wall surface as its original condition | — | — | — | 17,544 | |
| — | 750.00 | — | — | ||
| Extra cost for conceal wiring for main / submain with respect to PVC conduit / casing including make good of wall surface as its original condition | — | — | — | 15,750 | |
| — | 424.00 | — | — | ||
| Extra cost involvement for modular switch, bell push, plug socket, fan regulator, USB point, TV socket etc. with other accessories ( Make of Modular switch, socket, box, cover plate etc. - Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) ) | — | — | — | 42,824 | |
| — | 12.00 | — | — | ||
| Supply of SPN DB ( Metal Enclosure ), 6 way, 1Ph, 240V, 50Hz, complete with 4 nos. SP MCB of current rating from 6A to 32A, 10kA, 240V, 50Hz as per requirement of load and 1 no. DP RCBO of current rating 40A, 300mA, 10kA, 230V, 50Hz ( Make of MCB, RCBO and Metal Distribution Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / BCH / C&S / Havells ) | — | — | — | 62,880 | |
| — | 12.00 | — | — | ||
| Fixing, connection and commissioning of above SPN MCB DB with suitable arrangement including all incoming and outgoing cable connection with suitable cable termination arrangement. | — | — | — | 1,416 | |
| — | 4.00 | — | — | ||
| Supply of TPN MCB DB ( Metal Enclosure with Metal Door - IP 43 ), 3Ph, 4 way per phase, 415V, 50Hz, complete with 4 nos. SP MCB of current rating from 6A to 32A, 10kA, 240V, 50Hz per phase as per requirement of load and 1 no. FP RCBO, of current rating 63A, 300mA, 10kA, 415V, 50Hz. ( Make of MCB, RCBO and Metal Distribution Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / BCH / C&S / Havells ) | — | — | — | 46,236 | |
| — | 4.00 | — | — | ||
| Fixing, connection and commissioning of above TPN MCB DB with suitable arrangement including all incoming and outgoing cable connection with suitable cable termination arrangement. | — | — | — | 572 | |
| — | 91.00 | — | — | ||
| Fixing, connection, testing and commissioning of indoor LED luminaire fittings with suitable arrangement. ( LED indoor light fitting will be supplied by Railway ) | — | — | — | 6,279 | |
| — | 6.00 | — | — | ||
| Supply of LED 3W step/foot light integrated with high efficient LEDs with die-cast aluminium housing & clear glass (Colour temperature 3000K/4000K/6000K) complete with all accessories, operating voltage and frequency 230V AC, 50Hz | — | — | — | 2,862 | |
| — | 45.00 | — | — | ||
| Supply of Surface mounted tiltable/ flexible neck 7W LED spot luminaire as reading light with inbuilt driver and all other accessories | — | — | — | 99,675 | |
| — | 3.00 | — | — | ||
| Supply of Wall mounted 7W LED luminaire with flexible neck for adjusting beam for mirror top light with inbuilt driver similar to Philips Indoor Wall light Model No.- 919215850797 or equivalent including all other accessories | — | — | — | 6,465 | |
| — | 54.00 | — | — | ||
| Fixing, connection, testing and commissioning of indoor LED luminaire fittings with suitable arrangement. | — | — | — | 3,726 | |
| — | 3.00 | — | — | ||
| Installation, connection and commissioning of storage water heater with GI clamps made of GI flat of suitable size and GI nut-bolts ( Storage water heater will be supplied by Railway ) | — | — | — | 396 | |
| — | 25.00 | — | — | ||
| Fixing, connection and commissioning of BLDC Ceiling fan with suitable arrangement ( BLDC Ceiling Fan will be supplied by Railway ) | — | — | — | 1,225 | |
| — | 4.00 | — | — | ||
| Fixing, connection and commissioning of AC Exhaust Fan with suitable size and shape GI clamps / GI nut & bolts including necessary masonry work ( AC Exhaust Fan will be supplied by Railway ) | — | — | — | 568 | |
| — | 300.00 | — | — | ||
| Drawing of cable on wall / structure with suitable size and shape GI clamps and commissioning of cable ( Cable will be supplied by Railway ) | — | — | — | 11,400 | |
| — | 2.00 | — | — | ||
| Supply of Maintenance Free Copper Bonded Solid Earthing Rods with 25 kg Earth Enhance Compound with below specifications : a) Certified by CPRI and NABL Accredaited Lab b) ROHS certified c) Low Carbon High Tensile Rod d) Length of Electrode 3000 mm (3 Meter) e) Rod dia 17.2 mm f) Molecular Copper Plaring thickness 254 microns as per UL 467 g) Connection terminal size 32 mm x 6 mm with 10 mm hole along with nut bolt and washer including installation, testing and commissioning as per RDSO spec. no. RDSO/SPN/197 ver. 1.0 or latest and conforming to RDSO Drg. No. SDO/RDSO/E&B/001 or latest. ( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. / OBO Bettermann ) | — | — | — | 19,260 | |
| — | 2.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Documentsverificationcertificate3pgs.pdf
ATTACHMENT
Advancecorrectionslips.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
HTLTstandardspecification.pdf
ATTACHMENT
Tenderformandannexures.pdf
ATTACHMENT
TenderBooklet.pdf
ATTACHMENT
AnnexureVIB.pdf
ATTACHMENT
3429Clause.pdf
ATTACHMENT
RDSOSpecificationDrawingforMaintenanceFreeEarth.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .