| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.3 LAccepted-AOC DEEDAR MARKET ROOM NO UB 12 POLICE BAZAR SHILLONG 793001 | EAST KHASI HILLS | MEGHALAYA | 793001 | ₹36.3 L | L1 | Accepted-AOC AOC PLACED ON L1 BIDDER WITH CONTRACT AGREEMENT NO GE/SHL/12 OF 2024-2025 |
| 2 | L2₹37.3 L+₹95,214.92 (2.62%)Rejected-Finance ADDITIONAL SECRETARIAT COMPOUND SHILLONG EAST KHASI HILLS MEGHALAYA 793001 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793001 | ₹37.3 L+₹95,214.92 (2.62%) | L2 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER |
| 3 | L3₹38.9 L+₹2.6 L (7.17%)Rejected-Finance C O GUPTA EMPORIUM AR BAZAR HAPPY VALLEY SHILLONG 793 004 | EAST KHASI HILLS | MEGHALAYA | 793004 | ₹38.9 L+₹2.6 L (7.17%) | L3 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER |
| 4 | L4₹39.2 L+₹2.9 L (7.89%)Rejected-Finance | ₹39.2 L+₹2.9 L (7.89%) | L4 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER |
| 5 | L5₹39.2 L+₹2.9 L (8.02%)Rejected-Finance 777 AMAR NAGAR VILLAGE TOWN CITY RAE BARELI RAEBARELI UTTAR PRADESH 229001 INDIA | RAE BARELI | UTTAR PRADESH | 229001 | ₹39.2 L+₹2.9 L (8.02%) | L5 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER |
Tender Value
₹42.5 L
EMD Value
₹85,000
Closing Date
25 Mar 2024, 6:00 pmClosed
GE SHILLONG
GE SHILLONG SHILLONG DIVISION PIN 793002
PROVN OF 02 X SHEDS WITH HARD STANDING IN GAMES GROUND OF 58 GTC UNDER GE SHILLONG
2024_MES_644170_1
GE/SHL/TOKEN-75 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE SHILLONG
ALL AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE SHILLONG
₹85,000
Yes
1 Jun 2024
26 Feb 2024
26 Mar 2024
26 Feb 2024
25 Mar 2024
11 Mar 2024
Amount
B/R SCHEDULE Surface excavation in soft/disintegrated rock n.exc (not exceeding) 30 cm deep and averaging 20cm deep and getting out complete all as specified and directed.
Excavating in trenches in soft/loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Excavating in trenches in soft/disintegrated rock soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified and directed.
Rolling and consolidating formation surfaces in cutting using power roller 8 to 12 Ton complete all as specified and directed.
Removing excavated soils to a distance n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
Removing excavated soils to a distance exc. 250m but n exc 1.5km and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
M&L for PCC (1:4:8), type D2 using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
M & L for hardcore of broken brick/stone or boulders gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and remmed to a true surface, complete all as specified and directed.
M & L for 100mm thick PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregate as in sub base to floor finished even and rough complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for RCC M25 (Design mix) using 20mm graded crushed stone aggregate as in foundations including rafts, footings, plinth beams, bases for columns etc. complete all as specified and directed.
M&L for RCC M25 (Design mix) using 20mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts etc. complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surface of concrete complete all as specified and directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal, rough finished surface of concrete complete all as specified and directed.
M & L for mild steel TMT bars, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Ditto all as per Sl item No. 16 here-in-above but 6mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed.
M&L 75mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection/foot path finsihed even and smooth without using extra cement complete as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment complete as specified and directed.
M&L for precast cement concrete block masonary with solid blocks, exc 10cm in width or girth, made out of PCC (1:3:6) type C1 using 20mm graded crushed stone aggregate, and set in cement mortar (1:6) complete all as specified and directed.
M&L 15 mm thick rendering in CM 1:4 in two layers, first 10 mm thick base layer & finishing 5 mm thick with approved water proofing compound @ 3% by the weight of cement or as per manufacturer's instructions, finished even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid separately here-in-after.
Supply on integral water proofing compound.
M & L for preparation of new plastered concrete surfaces of wall and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of priming paint complete all as specified and directed.
M&L for MS as in roof trusses (framed), trussed, purlins, crane gantries, rails support columns for trusses and fastenings and heavy bracket framing(Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. quality conforming to Fe-410-W (Gde-E-250), quality-A complete all as specified and directed.
M&L for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes with riveted, bolted or welded attachment, quality conforming to Fe-410-W (Gde-E-250), quality-A complete all as specified and directed.
M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm but n exc 10cm long & dia of neck 5 to 10mm complete all as specified and directed.
S&F 0.50mm thick prepainted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for 1mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275gsm complete all as specified and directed.
M&L for preparation of steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends, any radius with access door complete all as specified and directed.
M&L for point wiring for one light/fan/exhaust fan point controlled by one, one way switch using PVC insulated unsheathed FRLSH multistranded copper conductor cable of size 1.5 sqmm nominal cross sectional area, 1100V grade, drawn in and including 20mm dia non metallic PVC conduit, concealed in wall/ceiling with all necessary accessories, cutting chases for concealed conduit wiring and making good disturbed surface, PVC modular board of suitable size for housing/mounting switches/sockets etc. and including PVC insulated unsheathed FRLSH multistranded copper conductor cable of size 1.5 sqmm nominal cross sectional area as earth wire and connecting to common earth dolly complete all as specified and directed.
Ditto all as per item No.33 here-in-above but for one 5 Amp socket on same board with other switches complete all as specified and directed.
M&L for point wiring for one socket outlet,3 pin 15A on independent board using PVC insulated unsheathed FRLSH multistranded copper conductor cable of size 2.5 sqmm nominal cross sectional area, 1100V grade, drawn in and including 20mm dia non metallic PVC conduit, concealed in wall/ceiling with all necessary accessories, cutting chases for concealed conduit wiring and making good disturbed surface, PVC modular board of suitable size for housing/mounting switches/sockets etc. and including PVC insulated unsheathed FRLSH multistranded copper conductor cable of size 2.5 sqmm nominal cross sectional area as earth wire and connecting to common earth dolly complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way 6 Amp, 230~250 volt , AC supply, ISI Marked complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way 16 Amp, 230~250 volt , AC supply, ISI Marked complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin, 6 and 16 amp flush type 230~250 volt , AC supply, ISI Marked complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin, 6A flush type 230~250 volt , AC supply, ISI Marked complete all as specified and directed.
S&F ceiling rose surface bakelite 65 mm x 50 mm, three terminals suitable for 230 Volts AC, 6 Amps complete all as specified and directed.
S&F MCB Distribution board, single pole and neutral , 8 ways, 240V double door, sheet steel enclosure powder coated with 100 Amps rated busbar with neutral link, fixed on wall duly grouted or on wooden board with all necessary electrical connections complete all as specified and directed.
S&F MCB SP, 6 to 32 Amps, 'C' series, 10KA, 240V and to be housed in DBs including necessary connection complete all as specified and directed.
S&F MCB SPN, 40 Amps, 'C' series, 10KA, 240V and to be housed in DBs including necessary connection complete all as specified and directed.
S & F LED light fitting 1X9W bulkhead luminaires including LED light, driver holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking down old unserviceable light fitting all as pecified and directed.
S&F LED light batten fitting 1x 20W, 220V, AC with driver, holder including LED tube light fixed to wall/ceiling with 02 Nos PVC block of suitable size and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking doown old unserviceable light fitting all as pecified and directed..
Excavation in trenches not exc 1.5m wide and not exc 1.50 in depth for laying of underground cables/pipes etc. and getting out in soft/loose soil complete all as specified and directed.
Supply, laying & testing of LT XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade and cross-sectional area 10 Sqmm 2 Core complete all as specified and as directed.
Supply and laying dry river sand filling for cable protection with a layer of 8cm deep before laying cable and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (Note: Punned thickness shall be measured).
M&L for Fly Ash compact modular bricks locally available of size laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed.
M&L for 40 mm bore galvanised iron tubing, light grade, ISI marked fas in protection of cable including necessary fittings complete all as specified and as directed.
M&L PCC 1:4:8, type D2 using 40mm graded crushed stone aggregates as in filling for road cutting for laying underground cable etc. complete all as specified and as directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified and directed.
Removing excavated soils to a distance n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I.complete all as specified and as directed.
SUNITA DEVI
M/S UTTAM SAHA
Bharara construction
Singh and Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .