Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹3.2 LAdmitted-Finance 4801 BHARAT RAM ROAD 24 DARYAGANJ DELHI CENTRAL DELHI DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | Admitted-Finance | |
| 2 | ₹4.8 LAdmitted-Finance PLOT NO 98 J AND K JIGANI INDUSTRIAL AREA II PHASE BENGALURU SOUTH BANGALORE KARNATAKA 560105 INDIA | BENGALURU URBAN | KARNATAKA | 560105 | Admitted-Finance | |
| 3 | ₹1.0 CrAdmitted-Finance 94 1ST FLOOR OLD ISHWAR NAGAR SHAMBHU DAYAL BAGH MARG NEAR OKHLA INDUSTRIAL AREA PHASE III NEW DELHI 110002 | NEW DELHI | NEW DELHI | DELHI | 110002 | Admitted-Finance | |
| 4 | ₹1.4 CrAdmitted-Finance C 125 NARAINA INDUSTRIAL AREA PHASE 1 NEW DELHI 110028 INDIA | NEW DELHI | NEW DELHI | DELHI | 110028 | Admitted-Finance | |
| 5 | ₹1.6 CrAdmitted-Finance 28 NAGARJUNA HILLS PUNJAGUTTA HYDERABAD TELANGANA 500082 | HYDERABAD | TELANGANA | 500082 | Admitted-Finance |
| Sl No | Description | Qty | Unit | T C Communication Pvt. Ltd | SUYOG ELECTRICALS LTD. | ELKAY TELELINKS LIMITED | Paramount Communications Limited | KEI INDUSTRIES LIMITED | LAPP INDIA PVT. LTD. | Delton Cables Limited | THERMO CABLES LTD | Cords Cable Industries Ltd. |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Supply of Instrumentation Cables for PP Unit Design, Engineering, Procurement, Manufacturing, Inspection, Testing and dispatch of the Instrumentation Cables along with accessories, commissioning spares, special tools & tackles, third party Inspection, etc. as specified in Technical Documention for EPCM 3 (P-25) PROJECT for IOCL, PNCP (PANIPAT NAPHTA CRACKER PLANT) / IOCL PR (PANIPAT REFINERY) . Detailed scope of supply as specified in MR Document No. 6746-INS-022-EC-0126 | ||||||||||||
| 1.01 | A : FIRE RETARDANT (FRLS) CABLES - 12P X 1.5 SQ.MM,IS | 14,900 | Meter | - | 74,49,255 ₹87,90,120.9 Lowest | 76,38,485.1 ₹90,13,412.42 | 80,81,611 ₹95,36,300.98 | 84,33,400 ₹99,51,412 | - | - | - | - |
| 1.02 | A : FIRE RETARDANT (FRLS) CABLES - 12P X 1.5 SQ.MM,NIS | 7,700 | Meter | - | 38,49,461 ₹45,42,363.98 Lowest | 39,47,405.1 ₹46,57,938.02 | 41,76,403 ₹49,28,155.54 | 43,58,200 ₹51,42,676 | - | - | - | - |
| 1.03 | A : FIRE RETARDANT (FRLS) CABLES - 12P X 2.5 SQ.MM,IS | 1,800 | Meter | - | 13,09,950 ₹15,45,741 Lowest | 14,03,964.1 ₹16,56,677.64 | - | 14,41,800 ₹17,01,324 | - | - | - | - |
| 1.04 | A : FIRE RETARDANT (FRLS) CABLES - 1P X 1.5 SQ.MM,IS | 5,100 | Meter | - | 3,29,358 ₹3,88,642.44 Lowest | 3,86,478.1 ₹4,56,044.16 | - | 4,13,100 ₹4,87,458 | - | - | 4,29,695.4 ₹5,07,040.57 | - |
| 1.05 | A : FIRE RETARDANT (FRLS) CABLES - 1P X 1.5 SQ.MM,NIS | 3,000 | Meter | - | 2,04,720 ₹2,41,569.6 Lowest | 2,27,340.1 ₹2,68,261.32 | - | 2,43,000 ₹2,86,740 | - | - | 2,52,762 ₹2,98,259.16 | - |
| 1.06 | A : FIRE RETARDANT (FRLS) CABLES - 1P X 2.5 SQ.MM,IS | 700 | Meter | - | 84,021 ₹99,144.78 | 64,260.1 ₹75,826.92 Lowest | - | 77,700 ₹91,686 | - | - | 79,894.5 ₹94,275.51 | - |
| 1.07 | A : FIRE RETARDANT (FRLS) CABLES - 2P X 1.5 SQ.MM,IS | 500 | Meter | - | 1,02,225 ₹1,20,625.5 | 65,735 ₹77,567.3 Lowest | - | 89,000 ₹1,05,020 | - | - | - | - |
| 1.08 | A : FIRE RETARDANT (FRLS) CABLES - 2P X 1.5 SQ.MM,NIS | 4,000 | Meter | - | 5,18,800 ₹6,12,184 Lowest | 5,25,760.1 ₹6,20,396.92 | - | 6,72,000 ₹7,92,960 | - | - | - | - |
| 1.09 | A : FIRE RETARDANT (FRLS) CABLES - 6P X 1.5 SQ.MM,IS | 4,200 | Meter | - | 11,72,514 ₹13,83,566.52 Lowest | 12,07,920.1 ₹14,25,345.72 | - | 13,39,800 ₹15,80,964 | - | - | - | - |
Tender Value
Refer Docs
Closing Date
30 Apr 2025, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Abhijeet Mithari
tkUIPL Pune
Supply of Instrumentation Cables Lot-2 for PP Unit
2025_REFHQ_184575_1
6746-PPM-022-CA-0165
Limited
Instrumentation-Goods
Supply
90 days
IOCL Panipat Refinery
Please refer tender documents
6 documents required · 6 mandatory
Exempted
19 Aug 2025
9 Apr 2025
2 May 2025
9 Apr 2025
30 Apr 2025
23 Apr 2025
Supply of Instrumentation Cables for PP Unit Design, Engineering, Procurement, Manufacturing, Inspection, Testing and dispatch of the Instrumentation Cables along with accessories, commissioning spares, special tools & tackles, third party Inspection, etc. as specified in Technical Documention for EPCM 3 (P-25) PROJECT for IOCL, PNCP (PANIPAT NAPHTA CRACKER PLANT) / IOCL PR (PANIPAT REFINERY) . Detailed scope of supply as specified in MR Document No. 6746-INS-022-EC-0126
A : FIRE RETARDANT (FRLS) CABLES - 12P X 1.5 SQ.MM,IS
A : FIRE RETARDANT (FRLS) CABLES - 12P X 1.5 SQ.MM,NIS
A : FIRE RETARDANT (FRLS) CABLES - 12P X 2.5 SQ.MM,IS
A : FIRE RETARDANT (FRLS) CABLES - 1P X 1.5 SQ.MM,IS
A : FIRE RETARDANT (FRLS) CABLES - 1P X 1.5 SQ.MM,NIS
A : FIRE RETARDANT (FRLS) CABLES - 1P X 2.5 SQ.MM,IS
A : FIRE RETARDANT (FRLS) CABLES - 2P X 1.5 SQ.MM,IS
A : FIRE RETARDANT (FRLS) CABLES - 2P X 1.5 SQ.MM,NIS
A : FIRE RETARDANT (FRLS) CABLES - 6P X 1.5 SQ.MM,IS
A : FIRE RETARDANT (FRLS) CABLES - 6P X 1.5 SQ.MM,NIS
B : FIRE RESISTANT (FR) CABLES - 12P X 1.5 SQ.MM,IS
B : FIRE RESISTANT (FR) CABLES - 12P X 1.5 SQ.MM,NIS
B : FIRE RESISTANT (FR) CABLES - 12P X 2.5 SQ.MM,IS
B : FIRE RESISTANT (FR) CABLES - 12P X 2.5 SQ.MM,NIS
B : FIRE RESISTANT (FR) CABLES - 1P X 1.5 SQ.MM,IS
B : FIRE RESISTANT (FR) CABLES - 1P X 1.5 SQ.MM,NIS
B : FIRE RESISTANT (FR) CABLES - 1P X 2.5 SQ.MM,IS
B : FIRE RESISTANT (FR) CABLES - 1P X 2.5 SQ.MM,NIS
B : FIRE RESISTANT (FR) CABLES - 2P X 1.5 SQ.MM,IS
B : FIRE RESISTANT (FR) CABLES - 2P X 1.5 SQ.MM,NIS
B : FIRE RESISTANT (FR) CABLES - 1T X 1.5 SQ.MM, NIS
B : FIRE RESISTANT (FR) CABLES - 8T X 1.5 SQ.MM, NIS
B : FIRE RESISTANT (FR) CABLES - 6P X 2.5 SQ.MM,NIS
B : FIRE RESISTANT (FR) CABLES - 6P X 1.5 SQ.MM,NIS
B : FIRE RESISTANT (FR) CABLES - 6P X 1.5 SQ.MM,IS
Supply of Instrumentation Cables for PP Unit Design, Engineering, Procurement, Manufacturing, Inspection, Testing and dispatch of the Instrumentation Cables along with accessories, commissioning spares, special tools & tackles, third party Inspection, etc. as specified in Technical Documention for EPCM 3 (P-25) PROJECT for IOCL, PNCP (PANIPAT NAPHTA CRACKER PLANT) / IOCL PR (PANIPAT REFINERY) . Detailed scope of supply as specified in MR Document No. 6746-INS-413-EC-0110
A. SIGNAL CABLE - FRLS - 6Px1.5mm2, FRLS, Blue, overall & Individual Shield,Armoured
B. SIGNAL CABLE - FIRE RESITANT (FR) - 2Px1.5mm2, FR, Black, overall & Individual Shield,Armoured
B. SIGNAL CABLE - FIRE RESITANT (FR) - 2Px2.5mm2, FR, Black, overall & Individual Shield,Armoured
B. SIGNAL CABLE - FIRE RESITANT (FR) - 6Px1.5mm2, FR, Blue, overall & Individual Shield,Armoured
B. SIGNAL CABLE - FIRE RESITANT (FR) - 6Px2.5mm2, FR, Black, overall & Individual Shield,Armoured
B. SIGNAL CABLE - FIRE RESITANT (FR) - 12Px1.5mm2, FR, Blue, overall & Individual Shield,Armoured
B. SIGNAL CABLE - FIRE RESITANT (FR) - 12Px2.5mm2, FR, Black, overall & Individual Shield,Armoured
B. SIGNAL CABLE - FIRE RESITANT (FR) - 1Tx2.5mm2, FR, Black, overall Shield,Armoured
C. T/C EXTENSION CABLE (FRLS) - 2Px20AWG, K type, FRLS, Green, overall & Individual Shield,Armoured
D. T/C EXTENSION CABLE FIRE RESITANT (FR) - 2Px20AWG, K type, FR, Green, overall & Individual Shield,Armoured
E. FOUNDATION FIELD BUS CABLE (FRLS) - 1Px18AWG, Fieldbus, FRLS, Orange, overall Shield,Armoured
E. FOUNDATION FIELD BUS CABLE (FRLS) - 2Px16AWG, Fieldbus, FRLS, Orange, overall & Individual Shield, Armoured
F. RS 485 CABLE - 2Px1.5mm2, RS-485 Modbus , Black
F. RS 485 CABLE - 1Px1.5mm2, RS-485 Modbus , Black
ELKAY TELELINKS LIMITED
Delton Cables Limited
Cords Cable Industries Ltd.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .